Permanent magnet pre-polarization in low field MRI measurements using SQUID

Similar documents
Magnetic Field Improved ULF-NMR Measurement in an Unshielded Laboratory Using a Low-Tc SQUID

doi: /j.physc

Batch production of YBCO disks for levitation applications.

Spatial encoding in Magnetic Resonance Imaging. Jean-Marie BONNY

Spatial encoding in Magnetic Resonance Imaging. Jean-Marie BONNY

Introduction to MRI. Spin & Magnetic Moments. Relaxation (T1, T2) Spin Echoes. 2DFT Imaging. K-space & Spatial Resolution.

Solid-Cryogen Cooling Technique for Superconducting Magnets of NMR and MRI

NMR/MRI examination (8N080 / 3F240)

Study on recovery performance of high T c superconducting tapes for resistive type superconducting fault current limiter applications

PROTEIN NMR SPECTROSCOPY

Principles of Nuclear Magnetic Resonance Microscopy

Development of a magnetic resonance microscope

Physica C 468 (2008) Contents lists available at ScienceDirect. Physica C. journal homepage:

Magnetic Resonance Imaging. Pål Erik Goa Associate Professor in Medical Imaging Dept. of Physics

Magnetization Gradients, k-space and Molecular Diffusion. Magnetic field gradients, magnetization gratings and k-space

Vibration characteristics of a multi-block high-temperature superconducting maglev system

Nuclear Magnetic Resonance Imaging

A fast method for the measurement of long spin lattice relaxation times by single scan inversion recovery experiment

NMR Instrumentation BCMB/CHEM Biomolecular NMR

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Performance test of a G-M cooler in magnetic field

Author(s) Atsushi; Urayama, Shinichi; Fukuyam. Citation Physics Procedia (2015), 65:

Impedance Evaluation of a Probe-Coil s Lift-off and Tilt Effect in Eddy-Current Nondestructive Inspection by 3D Finite Element Modeling

Sketch of the MRI Device

T 1, T 2, NOE (reminder)

Citation IEEE Transactions on Magnetics (201.

Introduction to Biomedical Imaging

Available online at ScienceDirect. Physics Procedia 67 (2015 )

External high-quality-factor resonator tunes up nuclear magnetic resonance

2 dimensional temperature measurement on YBCO thin film during S/N transition period by use of RuO 2 chip resistor

RADIOLOGIV TECHNOLOGY 4912 COMPREHENSEIVE REVIEW/MRI WORSHEET #1- PATIENT CARE AND SAFETY/PHYSICAL PRINCIPLES

Microtesla MRI with dynamic nuclear polarization

Study on Trapped Field Characteristics of HTS Bulk Annuli With Iron Rings for Ferromagnetic Shimming of a Compact NMR Magnet

Nuclear spin maser with a novel masing mechanism and its application to the search for an atomic EDM in 129 Xe

NMR, the vector model and the relaxation

Suppression of Static Magnetic Field in Diffusion Measurements of Heterogeneous Materials

Chemistry 431. Lecture 23

Chapter 7. Nuclear Magnetic Resonance Spectroscopy

Shimming of a Magnet for Calibration of NMR Probes UW PHYSICS REU 2013

Biophysical Chemistry: NMR Spectroscopy

Final Report. Superconducting Qubits for Quantum Computation Contract MDA C-A821/0000

Research Article Trial Application of Pulse-Field Magnetization to Magnetically Levitated Conveyor System

Part II: Magnetic Resonance Imaging (MRI)

The NMR Inverse Imaging Problem

Basic MRI physics and Functional MRI

Magnetoacoustic tomography with current injection

Nuclear Magnetic Resonance Imaging

The Influence on Levitation Force of the Bulk HTSC Above a Permanent Magnet Guideway Operating Dive-Lift Movement with Different Angles

Low Field MRI of Laser Polarized Noble Gases. Yuan Zheng, 4 th year seminar, Feb, 2013

Development of a cryogenic induction motor for use with a superconducting magnetic bearing

Current distribution in wide YBCO tapes

Relaxation times in nuclear magnetic resonance

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

16.1 Introduction to NMR Spectroscopy. Spectroscopy. Spectroscopy. Spectroscopy. Spectroscopy. Spectroscopy 4/11/2013

Influence of the ramp angle on levitation characteristics of HTS maglev

Title. Author(s)Terauchi, N.; Noguchi, S.; Igarashi, H. CitationPhysica C: Superconductivity, 471(21-22): Issue Date Doc URL.

Asian Journal of Chemistry; Vol. 25, No. 4 (2013),

Development of axial flux HTS induction motors

An Improved Spin Echo Train De-noising Algorithm in NMRL

With that first concept in mind, it is seen that a spinning nucleus creates a magnetic field, like a bar magnet

Atomic magnetometers: new twists to the old story. Michael Romalis Princeton University

General NMR basics. Solid State NMR workshop 2011: An introduction to Solid State NMR spectroscopy. # nuclei

Band-Selective Homonuclear 2D Correlation Experiments

Mitigation of Demagnetization of Bulk Superconductors by Time-Varying External Magnetic Fields

Effect of Discontinuities and Penetrations on the Shielding Efficacy of High Temperature Superconducting Magnetic Shields

Spatial and Temporal Variations of a Screening Current Induced Magnetic Field in a Double-Pancake HTS Insert of an LTS/HTS NMR Magnet

V27: RF Spectroscopy

Chem 325 NMR Intro. The Electromagnetic Spectrum. Physical properties, chemical properties, formulas Shedding real light on molecular structure:

Introduction to MRI Acquisition

Field homogeneity improvement of maglev NdFeB magnetic rails from joints

NMR Spectroscopy Laboratory Experiment Introduction. 2. Theory

An Analytical approach towards passive ferromagnetic shimming design for a high-resolution NMR magnet

Outlines: (June 11, 1996) Instructor:

LECTURE 23 INDUCED EMF. Instructor: Kazumi Tolich

Effect of Pre-magnetization on Quasistatic Force Characteristics in a Space Superconducting Interface Structure Adopting High T c Superconductors

October 23. Physics 272. Fall Prof. Philip von Doetinchem

Magnetic Resonance Imaging (MRI)

Analytical and Experimental Studies on the Hybrid Fault Current Limiter Employing Asymmetric Non-Inductive Coil and Fast Switch

Introduction to Nuclear Magnetic Resonance Spectroscopy

CRITICAL CURRENT AND JUNCTION BETWEEN PANCAKE STUDIES FOR HTS COIL DESIGN

Principles of Magnetic Resonance Imaging

CONTENTS. 2 CLASSICAL DESCRIPTION 2.1 The resonance phenomenon 2.2 The vector picture for pulse EPR experiments 2.3 Relaxation and the Bloch equations

NMR course at the FMP: NMR of organic compounds and small biomolecules - II -

Journal of the Korean Magnetic Resonance Society 2003, 7, Kwangju, , KOREA Received September 29, 2003

Technical University of Denmark

Cryogenic and Electrical Test Results of a 30 M HTS Power Cable

Natural abundance solid-state 95 Mo MAS NMR of MoS 2 reveals precise 95 Mo anisotropic parameters from its central and satellite transitions

Chapter 15:Magnetic Resonance Imaging

A flux pumping method applied to the magnetization of YBCO superconducting coils: frequency, amplitude and waveform characteristics

Electromagnetic Induction Practice Problems Homework PSI AP Physics B

MRI Physics II: Gradients, Imaging. Douglas C. Noll, Ph.D. Dept. of Biomedical Engineering University of Michigan, Ann Arbor

Chapter 13: Nuclear Magnetic Resonance (NMR) Spectroscopy direct observation of the H s and C s of a molecules

XXXXXXXXXXXXXXX. First Pre-Board Examination, Physics

Principles of MRI. Vinyl Record. Last time: Today: Homework Due tonight! EE225E / BIO265. Transforms a temporal signal to a spatial signal

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam

Effects of the field dependent J/sub c/ on the vertical levitation force between a superconductor and a magnet

Nuclear magnetic resonance spectroscopy

NMR BMB 173 Lecture 16, February

Schematic for resistivity measurement

Index. p, lip, 78 8 function, 107 v, 7-8 w, 7-8 i,7-8 sine, 43 Bo,94-96

Two-Dimensional Nuclear Magnetic. Resonance at Zero-Field

Transcription:

Available online at www.sciencedirect.com Physics Procedia 36 (2012 ) 274 279 Superconductivity Centennial Conference Permanent magnet pre-polarization in low field MRI measurements using SQUID Chao Liu a,b,c, Yi Zhang a,c, a*, Longqing Qiu b,c, Hui Dong b,c, Hans-Joachim Krause a,c, Xiaoming Xie b,c, Andreas Offenhäusser a,c, Mianheng Jiang b,c a Peter Grünberg Institute(PGI-8), Forschungszentrum Jülich(FZJ), Jülich, Germany b Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences(CAS), Shanghai, China c Joint Research Laboratory on Superconductivity & Bioelectronics, Collaboration between CAS-Shanghai & FZJ Abstract In order to improve signal-to-noise ratio of low-field Magnetic Resonance Imaging (MRI) measurements, a Permanent Magnet (PM) with a field of about 1 T was used as pre-polarizing field and a tuned high-t c (HTS) rf Superconducting Quantum Interference Device (SQUID) acted as signal detector. Measurements were performed in a Magnetically Shielded Room (MSR) with the door open, while the PM was located outside. A manual mechanical transport system was used to repeatedly move sample from the PM to the measuring position beneath the SQUID. The two-dimensional LF-MRI of a sample tube of 0.5 ml tap water demonstrates the feasibility of this concept. 2012 2011 Published by Elsevier B.V. Ltd. Selection and/or peer-review under responsibility of of Horst the Guest Rogalla Editors. and Peter Open access Kes. under CC BY-NC-ND license. Keywords: Permanent magnet, Pre-polarization, SQUID, LF-MRI 1. Introduction Recently, low-field (LF) Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI) using Superconducting Quantum Interference Device (SQUID) as a signal detector have been demonstrated [1-3]. Compared to conventional high field MRI, LF-MRI exhibits some advantages: moderate requirements on the field homogeneity, the possibility to perform imaging in the presence of metal objects [4], and enhanced T 1 -contrast imaging which can discriminate different types of tissues [5]. In such measurements, there are two magnetic fields, pre-polarization field (B p ) and measurement field * Corresponding author. E-mail address: y.zhang@fz-juelich.de. 1875-3892 2012 Published by Elsevier B.V. Selection and/or peer-review under responsibility of the Guest Editors. Open access under CC BY-NC-ND license. doi:10.1016/j.phpro.2012.06.159

Chao Liu et al. / Physics Procedia 36 ( 2012 ) 274 279 275 (B M ). Magnetization (M) of a sample is proportional to B p while B M determines the Larmor frequency f L. Here, the signal amplitude, or say, signal-to-noise ratio (SNR) of MRI measurements scales only with B p when a SQUID is used. Usually, a polarizing field B p of 10 50 mt is generated by copper wire wound coils such as solenoid or coil pair [3, 6, 7]. When using such coils to produce a B p larger than 50 mt, several problems arise such as the heating effect produced by the large current through the coil, the long switch-off time of B p, and flux trapping in the SQUID. Furthermore, an induced eddy current in the μ-metal caused by the suddenly changing B p may bring down the measurement if the measurement is performed in a Magnetically Shielded Room (MSR). There is another possibility to obtain a large B p, namely, utilizing a Permanent Magnet (PM). Appelt et al. used a cylindrical Halbach PM with typical field strength of 1-2 T inside the bore to observe the highresolution molecular structure with NMR in the Earth s field [8]. Liao et al. utilized a PM with 0.74 T to pre-polarize 9 ml tap water and achieved a SNR of about 140 in a single NMR measurement [9]. In these two works, a Faraday coil was employed as detector. In this paper, we use a PM pair which generates a field of about 1 T as B p and a tuned high-t c (HTS) rf SQUID as a signal detector [10] to perform not only LF-NMR but also LF-MRI measurements. Using a manual mechanical transport system to transfer the sample from the magnet site to the SQUID, 2-D LF- MRI measurements of 0.5 ml tap water samples are reported. 2. Setup and Sequence Our setup is schematically shown in Fig. 1 (a). It consists of four parts: coil system, SQUID system, a PM pair and a mechanical transport system: i) Coil system A Helmholtz coil pair was used to generate a measurement field B M. An excitation field B ac in the y direction was produced by a coil pair which is not shown in Fig.1 (a). The gradient field G zz was generated by a Maxwell coil pair whereas the other two gradient fields, G zx & G zy, were produced by a planar gradient coil pair. ii) SQUID system One tuned HTS rf SQUID which consisted of an rf SQUID magnetometer [10] and a LC resonant circuit was positioned at the bottom of the cryostat. The f L of our MRI experiments was selected to be about 9 khz, which yielded a good compromise between the sensitivity of the sensor, the stability and homogeneity of the measurement field, and the minimization of environmental disturbance. And the sensitivity of the tuned rf SQUID is about 6-7 ft/ Hz. iii) PM pair The PM was made of NdFeB, with diameter of 120 mm and height of 50 mm. The PM pair with gap space of 30 mm was enclosed by a yoke consisting of four soft iron pieces. It generates a B p field of about 1 T in the center of the gap. Because strong PM may impair the homogeneity of the magnetic field in the vicinity of the magnet, the PM should be placed as far as possible from the measuring position under SQUID. Here, the coil system and SQUID were placed in the MSR while the PM pair was located outside. The distance between

276 Chao Liu et al. / Physics Procedia 36 ( 2012 ) 274 279 PM pair and the measuring position was about 1.8 m. In order to move the sample between the PM pair and the SQUID detector, a mechanical transport system is needed. iv) Mechanical transport system The mechanical transport system consists of a weight, three pulleys, and a slide rail made of Aluminium. Due to the gravity of the weight, the sample is pulled along the slide rail to the measuring position. At the end of the slide rail, there is a micro-switch which produces a TTL pulse when the sample reaches the measuring position. A transport time determined by the weight and the length of the slide rail, usually is 1 ~ 2 s. During the transporting process, the free induction decay (FID) signal is decreasing exponentially by: Y = A 0 * exp (- t / T 2 ) 1 Here, A 0 is the initial amplitude, and T 2 is the spin-spin relaxation time which is about 3.4 s for pure water in the room temperature [11]. Theoretically, A 0 of PM with 1 T is twenty times larger than that of polarizing coil with 50 mt, and it is assumed that the measurements with polarizing coil can be started immediately after B P is switched off. According to the formula (1), when polarizing the sample of pure water in the 1 T PM and starting the measurement after 1 ~ 2 s transport time, the initial amplitude of the FID signal can be enhanced by about one order of magnitude compared to using polarizing coils of 50 mt and starting the measurement without delay. Therefore, with the use of a PM for sample polarization, it is possible to improve the SNR of LF-MRI measurements. However, it is uncomfortable that the sample has to be transported between PM and the measuring position, compared to polarizing coils Fig.1. (a) Schematics of tuned HTS rf SQUID-based LF-MRI, (b) sequences used in the measurements. All experiments were performed in the MSR with its door open. Fig. 1(b) shows the sequences. First, the sample is pre-polarized for about 5 s by the PM pair. After polarization, the sample is transported to the measuring position. Once the sample reaches the measuring position, the micro-switch produces a TTL signal to start the sequence. Subsequently a 90 0 pulse is applied to tilt the magnetization M perpendicular to B M. After a B ac pulse, undesired transient ringing is induced in the LC circuit. This ringing may cover the FID signals because the duration of the ringing is comparable to that of the signals. To effectively damp the ringing, we used a Q switch circuit developed by Dong et al. [12]. The Q value of LC circuit is kept low until the B ac pulses ends. Subsequently, the Q value increases gradually to its maximum and the data acquisition starts. The measurement field B M in the following measurements was about 213 μt (f L 9.068 khz). The FID and spin echo signals were recorded by a HP 3562A dynamic signal analyzer.

Chao Liu et al. / Physics Procedia 36 ( 2012 ) 274 279 277 3. Experimental results 3.1. NMR measurement In order to characterize the sensitivity of our system, NMR measurement with a sample of 0.1 ml tap water was performed. Fig. 2 shows the FID signal in a single measurement (a) and its spectrum (b), in which a SNR of about 60 was demonstrated and the corresponding spectral linewidth was about 0.75 Hz. The signal also can be averaged, for example, the SNR was increased to about 110 after 5-times averaging (not shown here). The results demonstrate that the SNR can be greatly improved using a PM for sample polarization, compared to our former works using a coil electromagnet [7, 13]. Fig. 2. (a) Real-time FID signal of 0.1 ml tap water without averaging, (b) its corresponding spectrum with a SNR of about 60. 3.2. 1-D MRI measurements The basic principle of MRI is that by applying magnetic gradient field, spatial coordinates of magnetic resonance signals can be determined. In the following measurements, two tubes with tap water (each tube has a length of 30 mm and a diameter of 4.5 mm, and the volume is about 0.5 ml) were separated by a distance of about 20 mm (see Fig. 3 (a)). In the absence of the gradient field, the FID signal of a single measurement is presented in Fig.3 (b). The FID signal should be decaying exponentially as indicated by the dashed lines with T 2 of 3.4 s. The observed stronger decay of the signal is caused by the inhomogeneity of the measurement field B M which may lead to a distortion of the MRI images. When applying a gradient field of G zz of 47 μt/m, corresponding to 20 Hz/cm, FID (I) and spin echo (II) signals in a single measurement are shown in Fig. 3. (c). For spin echo measurement, the π pulse was applied at t d = 0.13 s. In order to improve the spectral resolution, FID (I) and spin echo (II) signals were extended to 2 s when performing a Fast Fourier Transform (FFT), and their corresponding spectra are shown in Fig. 3. (d). In the spectra, two peaks are separated by about 40 Hz which fit well to a geometric distance of about 2 cm. Though the amplitude of the echo signal is smaller than that of the FID signal, their SNRs are almost same and about 30. This result is in agreement with the report of Dong et al. [13]. Here, the spectral linewidth of about 6.5 Hz of the echo signal is smaller than that of 9.3 Hz of FID signal. These experiments demonstrate that MRI using a strong permanent magnet for sample polarization, a mechanical sample transportation and a tuned rf SQUID as signal detector is feasible.

278 Chao Liu et al. / Physics Procedia 36 ( 2012 ) 274 279 Fig. 3. (a) schematics of the sample: two tubes with 0.5 ml tap water each; (b) FID signal in a single measurement; (c) FID (I) and spin echo (II) signals in a single measurement with a gradient field G zz of 20 Hz/cm; (d) FFT spectra obtained from the signals of (c), and curve I, II corresponds to FID and spin echo signals, respectively. 3.3. 2-D MRI measurements In 2D MRI, one tube was chosen as the sample (see Fig. 4 (a)). The 2D MRI image was acquired based on the filtered back-projection reconstruction. During the 2D MRI measurements, the direction of the gradient field was rotated from 0 0 to 180 0 with 12 steps. For every step, the FID signal of a single measurement was recorded. The reconstructed 2D image with a gradient field of 20 Hz/cm is shown in Fig. 4 (b). The dotted lines indicate the geometric contours of the sample. It can be observed that the center of the image is bright and the edge is blurred. This is caused by less of water at the edge of the tube than in the center. The deviation of the reconstructed image from the geometrical dimension may be caused by the inhomogeneity of B M. Fig.4. (a) photo of sample, (b) the reconstructed image of one tube with 0.5 ml tap water acquired with a gradient field of 20 Hz/cm.

Chao Liu et al. / Physics Procedia 36 ( 2012 ) 274 279 279 4. Conclusions With a strong sample polarization in a 1 T permanent magnet and a manual mechanical transport system to transfer the sample from the PM to the SQUID sensor, we showed the feasibility of MRI imaging at low fields. The SNR of measurements was improved greatly as compared to polarization using a coil electromagnet. A 2D image of one tube of 0.5 ml tap water was demonstrated, and only single measurements were utilized to reconstruct the image. In the future, the homogeneity of B M should be improved to perform MRI measurements of large samples and an automatic mechanical transportation should be applied to improve the precision of sample positioning. References [1] R. McDermott et al., Liquid-state NMR and scalar couplings in microtesla magnetic fields, Science, vol. 295, pp. 2247 2249, 2002. [2] R. McDermott et al., Microtesla MRI with a superconducting quantum interference device, Proc. Natl. Acad. Sci., vol. 101, no. 21, pp. 7857 7861, 2004. [3] V. S. Zotev et al., Multi-channel SQUID system for MEG and ultra-low-field MRI, IEEE Trans. Appl. Superconduct., vol. 17, no. 2, pp. 839 842, 2007. [4] M. Mößle et al., SQUID-detected microtesla MRI in the presence of metal, J. Magn. Reson., vol. 179, pp. 146 151, 2006. [5] S. K. Lee et al., SQUID-detected MRI at 132 T with T1-weighted contrast established at 10 T 300 mt, Magn. Reson. Med.,vol. 53, pp.9 14, 2005. [6] V. S. Zotev et al., SQUID-based instrumentation for ultralow-field MRI, Supercond. Sci. Technol., vol. 20, pp. S367 S373, 2007. [7] L. Q. Qiu et al, Nuclear magnetic resonance in the earth s magnetic field using a nitrogen-cooled superconducting quantum interference device, Appl. Phys. Lett. 91, 072505 (2007). [8] S. Appelt et al, Chemical analysis by ultrahigh-resolution nuclear magnetic resonance in the Earth s magnetic field, nature physics, vol. 2, pp. 105-109, 2006. [9] S. H. Liao et al, A study of J-coupling spectroscopy using the Earth s field nuclear magnetic resonance inside a laboratory, Rev. Sci. Instrum. 81, 104104 (2010). [10] Y. Zhang, J. Schubert, N. Wolters, M. Banzet, W. Zander, and H. -J. Krause, Substrate resonator for HTS rf SQUID operation, Physica C, vol. 372-376, pp. 282 286, 2002. [11] V. Graf, F. Noack and G. J. Béné, Proton spin T 1 relaxation dispersion in liquid H 20 by slow proton-exchange, J. Chem. Phys. 72(2), pp.861-863, 1980. [12] H. Dong et al, Suppression of ringing in the tuned input circuit of a SQUID detector used in low-field NMR measurements, Supercon. Sci. Technol., vol. 22, 125022, 2009. [13] H. Dong et al, Low Field MRI Detection with tuned HTS SQUID magnetometer, IEEE Transactions on Applied Superconductivity, vol. 21 No. 3, pp.509-513, June 2011.