Construction of the Belle II TOP counter

Similar documents
Performance of the MCP-PMT for the Belle II TOP counter

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

The Barrel DIRC Detector for the PANDA Experiment at FAIR

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

The Fast Interaction Trigger Upgrade for ALICE

Particle Identification at a super B Factory. FRASCATI WORKSHOP DISCUSSION ON PID

Cherenkov Detectors in Particle Physics. Brad Wogsland University of Tennessee

arxiv: v1 [physics.ins-det] 3 Dec 2018 Fast Interaction Trigger for the upgrade of the ALICE experiment at CERN: design and performance

Time of Flight measurements with MCP-PMT

GRAINE Project: a balloon-borne emulsion gamma-ray telescope

Muon reconstruction performance in ATLAS at Run-2

OPTICAL PROPERTIES OF THE DIRC FUSED SILICA CHERENKOV RADIATOR

The EDM Polarimeter Development at COSY-Jülich

RICH detectors for LHCb

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

ALIGNMENT OF THE MSGC BARREL SUPPORT STRUCTURE

PoS(EPS-HEP2015)522. The status of MICE Step IV

The Silicon-Tungsten Tracker of the DAMPE Mission

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

clfv searches using DC muon beam at PSI

Validation of Geant4 Physics Models Using Collision Data from the LHC

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

Aerogel RICH counter for the Belle II forward PID

PoS(ICRC2015)635. The NICHE Array: Status and Plans. Douglas R Bergman

The TORCH project. a proposed detector for precision time-of-flight over large areas. Roger Forty (CERN)

BaBar DIRC in SoLID. P. Nadel-Turonski, Z. Zhao, C. Hyde... SoLID bi-weekly meeting, January 15, 2013

Development of Secondary Electron Time Detector for Ion Beams

Status of the LHCb RICH and hadron particle identification

Study of highly transparent silica aerogel as a RICH radiator

Investigation of nuclear Equation of State (EoS) is an attractive subject not only for nuclear

Cherenkov light imaging in particle and nuclear physics experiments

Results from BABAR/PEP-II - One Year of Operations

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

THE LHCb experiment [1] is a forward spectrometer

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

A RICH Photon Detector Module with G-APDs

PoS(ICHEP2016)552. The Mu3e Experiment at PSI. Alessandro Bravar University of Geneva

Emittance Measurement in the Muon Ionization Cooling Experiment

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

A gas-filled calorimeter for high intensity beam environments

The HERA-B ring imaging Cherenkov system } design and performance

hadronic decays at BESIII Abstract hadronic decays using a double tag technique. Among measurement for twelve Λ c

Brief Report from the Tevatron. 1 Introduction. Manfred Paulini Lawrence Berkeley National Laboratory Berkeley, California 94720

Development of New MicroStrip Gas Chambers for X-ray Applications

PoS(BORMIO2016)013. PANDA Forward Spectrometer Calorimeter. P.A. Semenov IHEP NRC KI S.I. Bukreeva IHEP NRC KI ITEP NRC KI

A copy can be downloaded for personal non-commercial research or study, without prior permission or charge

PoS(ICRC2015)641. Cloud Monitoring using Nitrogen Laser for LHAASO Experiment. Z.D. Sun 1,Y. Zhang 2,F.R. Zhu 1 for the LHAASO Collaboration

Results from combined CMS-TOTEM data

XMASS 1.5, the next step of the XMASS experiment

GRAINE project: Cosmic Gamma-ray Observation by Balloon-Borne Telescope with Nuclear Emulsion

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons

PoS(EPS-HEP2017)533. First Physics Results of AWAKE, a Plasma Wakefield Acceleration Experiment at CERN. Patric Muggli, Allen Caldwell

arxiv: v1 [physics.ins-det] 28 Mar 2018

Development of aerogel Cherenkov counters at Novosibirsk

GP-B Telescope Determine Metering Tube Length P0364 Rev -

The NUCLEON Space Experiment Preliminary Results. Skobeltsyn Institute of Nuclear Physics, Moscow State University, Moscow, , Russia

R&D and related Simulation Studies for the sphenix Time Projection Chamber

Particle Identification with Disc DIRC at PANDA

Status and Perspectives for KM3NeT/ORCA

A progress report on the development of the CsI-RICH detector for the ALICE experiment at LHC

a) National Laboratory for High Energy Physics (KEK), b) Saga University, c) National Kaohsiung Normal University, d) National Taiwan University,

Timing calibration of the LHAASO-KM2A electromagnetic particle detectors

Accelerator Based Particle Physics Experiments

Thick-wall, Liquid-Filled Quartz Capillaries for Scintillation and Wavelength Shifting Applications

PoS(Vertex 2016)004. ATLAS IBL operational experience

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Detector Design Studies For High Precision Particle Physics Experiment

PoS(ICHEP2016)474. SoLid: Search for Oscillations with a Lithium-6 Detector at the SCK CEN BR2 reactor

ALIGNMENT RESULT FOR MAGNET UNITS OF THE SPRING-8 STORAGE RING

The ATLAS Silicon Microstrip Tracker

DEPFET sensors development for the Pixel Detector of BELLE II

Physics potential of ATLAS upgrades at HL-LHC

PoS(PhotoDet 2012)008

PoS(HCP2009)042. Status of the ALICE Experiment. Werner Riegler. For the ALICE Collaboration. CERN

THE CERN NA62 experiment [1] aims to measure the

The experiment at JINR: status and physics program

The Aerogel Forward RICH detector for PANDA

Problem Solving. radians. 180 radians Stars & Elementary Astrophysics: Introduction Press F1 for Help 41. f s. picture. equation.

Neutrino oscillation physics potential of Hyper-Kamiokande

Future Belle II experiment at the KEK laboratory

Track measurement in the high multiplicity environment at the CBM Experiment

Light ion recoil detector

Frascati Physics Series Vol. XVI (2000), pp PHYSICS AND DETECTORS FOR DANE { Frascati, Nov , 1999 BNL E787 results on K +! + Takahiro S

LHC status and upgrade plan (physics & detector) 17 3/30 Yosuke Takubo (KEK)

Detector R&D in KAPAC

LHCb Calorimetry Impact

PoS(ICHEP2016)293. The LArIAT experiment and the charged pion total interaction cross section results on liquid argon. Animesh Chatterjee

Muon track reconstruction and veto performance with D-Egg sensor for IceCube-Gen2

Lecture 16 Light transmission and optical detectors

Hadronic vs e + e - colliders

ARTICLE IN PRESS. Lifetime of MCP PMT. N. Kishimoto, M. Nagamine, K. Inami, Y. Enari, T. Ohshima

Results from R&D of Cherenkov detectors at Novosibirsk

Super KEKB and Belle II: Status of the KEK Super B Factory

Fine Alignment of the ATF Damping Ring

A Start-Timing Detector for the Collider Experiment PHENIX at RHIC-BNL

PoS(PD07)031. General performance of the IceCube detector and the calibration results

Picosecond Time-of-Flight Measurement for Colliders Using Cherenkov Light

PANDA Muon System Prototype

Transcription:

, For the Belle II TOP group KMI, Nagoya University E-mail: matsuoka@hepl.phys.nagoya-u.ac.jp The Belle II experiment operating at SuperKEKB of the luminosity frontier accelerator will perform high precision flavor physics measurements. An efficient particle identification is essential for Belle II to extend its reach toward new physics, and it is realized by the TOP counter. The TOP counter is a novel ring imaging Cherenkov detector, which measures the time of propagation (TOP) of the internally reflected Cherenkov photons. The TOP counter mainly consists of a quartz optics, micro-channel-plate photomultiplier tubes and front-end electronics. After the long R&D of more than a decade, we succeeded in producing those components, assembling the 16 TOP counter modules and finally installing them in 2016. That is one of the biggest milestones of the Belle II construction. This article reviews the TOP counter in terms of the production of each component and the construction. The 3rd International Symposium on Quest for the Origin of Particles and the Universe 5-7 January 2017 Nagoya University, Japan Speaker. c Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0). http://pos.sissa.it/

1. Introduction After the successful B-factory experiments [1], which confirmed Kobayashi-Maskawa theory with about 1 ab 1 data, the Belle II experiment [2] is going to search for new physics via precision measurements with 50 ab 1 data to be collected at the next generation B-factory, SuperKEKB [3]. In Belle II K ± /π ± particle identification in the barrel region is done by 16 modules of the TOP (Time-Of-Propagation) counter [4 7] illustrated in Fig. 1. The expected misidentification probability of pions, for example, is 3% when one selects 1-2 GeV/c kaons at 86% efficiency, while it was about 10% in Belle [8]. The TOP counter is a state-of-the-art Cherenkov ring imaging detector, which mainly consists of a 2.7 m long quartz optics, photon sensors at the end of the optics and front-end electronics attached to the photon sensors as shown in Fig. 1. It identifies kaons and pions by means of precise timing measurement of internally reflected Cherenkov photons in the quartz optics as well as the time of flight of the particle. The time of propagation of those photons depends on the Cherenkov angle or the mass of the particle of a given momentum by the inner tracker. One of the key techniques for the TOP counter is to propagate the ring image without distortion by the quartz optics. In addition the photon sensors and the electronics are required to have an excellent time resolution better than 50 ps, which is essential to distinguish the time difference between Cherenkov photons from a kaon and a pion. Detecting the photons with a high efficiency is also essential because the typical number of detected photons per track is only about 20. Hence we developed a square-shaped micro-channel-plate photomultiplier tube (MCP-PMT) [9 14] which can be arrayed to have a large photocoverage. It was quite challenging to incorporate those features. After the TOP counter concept was proposed at Nagoya in 2000, it took a long time to prove the principle of the TOP counter using a full-scale prototype at a beam test [15, 16] in 2013 and to get the construction of all the 16 and a spare TOP counter modules done in 2016. This article reviews the TOP counter in terms of the production of the key components and the construction. e 20 mm e + e + 1190 mm e Interaction point Figure 1: Schematic view of the Belle II detector indicating the barrel region covered by 16 modules of the TOP counter (left) and one of the TOP counter modules (right). 1

Table 1: Specifications of the quartz bar. The flatness, perpendicularity, parallelism and roughness in this table indicate the specification for the largest surfaces. internal reflectance (%) Length 1250±0.50 mm 99.96 Width Flatness 450±0.15 mm < 6.3 µm Thickness Perpendicularity 20±0.10 mm < 20 arcsec 99.94 99.92 Parallelism < 4 arcsec 99.9 98.5 99 99.5 100 Roughness < 5 Å (RMS) bulk transmittance (%/m) 2. Key components of the TOP counter 2.1 Quartz bar 100 99.98 Figure 2: Measured internal reflectance and bulk transmittance of the quartz bars. The quartz optics consists of two 1250 450 20 mm bars, which form a 2500 mm long bar, a prism at the end of the bar and a mirror at the other end. The material of all of the optics is Corning 7980 synthetic fused silica, which has no inclusions and is free of striae. To keep the Cherenkov image after typically a few hundreds of reflections in the quartz bar, the surfaces of the quartz bar are highly polished. The requirements for the surfaces is stringent as listed in Table 1. The preproduction and production of 34 quartz bars including two spares started in 2012 and 2014, respectively. Zygo Corporation produced thirty quartz bars and Okamoto Optics Works, Inc. produced four including two spares. For quality assurance the internal reflectance and the bulk transmittance of the produced bars were measured by using a laser. As shown in Fig. 2 all the quartz bars met the requirements which were > 99.9% internal reflectance and > 98.5%/m bulk transmittance. 2.2 MCP-PMT The MCP-PMT (Fig. 3) was developed in collaboration with Hamamatsu Photonics K.K. It contains two micro-channel-plates, of which channel diameter and thickness are 10 µm and 400 µm, respectively. It has an enough gain to detect single photons even in 1.5 T of the Belle II solenoid. Because the electrons are multiplied inside the very narrow channels of the thin plate, the MCP-PMT has a transit time spread less than 40 ps for single photons. The outer size of the MCP-PMT is 27.6 27.6 mm 2, and the size of the photocathode is 23 23 mm 2. Thus 73% of the prism edge face can be covered by the photocathode of two rows of 16 MCP-PMTs. A multi-alkali (NaKSbCs) photocathode is adopted to fulfill the required quantum efficiency which is at least 24% and 28% on average of all MCP-PMTs at the peak wavelength around 360 nm. The 512 MCP-PMTs to be installed in 16 TOP counter modules and more than 60 spares were produced in five years from 2011. The measured peak quantum efficiency for the 512 MCP-PMTs 2

40 Entries 512 Mean 29.31 RMS 2.179 30 20 Figure 3: MCP-PMT for the TOP counter. 10 0 20 22 24 26 28 30 32 34 36 38 quantum efficiency (%) Figure 4: Measured quantum efficiency at a peak wavelength around 360 nm for the installed 512 MCP-PMTs. is plotted in Fig. 4. The achieved average quantum efficiency is 29.3%, which is greater than the requirement. Another big achievement in terms of the MCP-PMT R&D is extension of the lifetime. The lifetime of the MCP-PMT is limited by deterioration of the photocathode or the degradation of the quantum efficiency due to outgassing from the micro-channel-plates induced by the multiplied electrons. The quantum efficiency degrades as a function of the integrated amount of the output charge per photocathode area, which is dominated by the severe beam background in Belle II. It is estimated by a Monte Carlo simulation to be several C/cm 2 after collecting 50 ab 1 data at the MCP-PMT gain of 5 10 5. On the other hand the lifetime when the quantum efficiency drops down to 80% of the beginning was 0.1 C/cm 2 or less for the early prototypes of the MCP-PMT [13]. It was improved to 1.1 C/cm 2 on average of 12 samples of the first production version, 10.5 C/cm 2 on average of 8 samples of the second version, and at least 13.6 C/cm 2 for 8 samples of the third version [17]. 2.3 Front-end electronics A eight-channel, multi-giga sample per second, transient waveform recorder ASIC (Application- Specific Integrated Circuit) [18] was developed for the TOP counter readout by the University of Hawaii. Four ASICs are mounted on a carrier board with an FPGA (Field Programmable Gate Array) which controls the ASICs and processes the data. Four carrier boards are stacked with another board which is a master control, and they compose a board stack of dense and compact package to fit in the limited space behind the MCP-PMT array. 3. Construction of the TOP counter 3.1 Assembly of the TOP counter Assembly of the 16 production TOP counter modules started in March 2015 and finished in April 2016 almost as planned. The assembly of each module starts with alignment and gluing of 3

Quartz Aluminum plate Micrometer head Aluminum plate Table Rail Figure 5: Alignment stages with the quartz optics (left) and a cross-sectional view of the stage (right). the quartz optics in a clean room. A prism, two bars and another short bar with the mirror are put on special alignment stages as shown in Fig. 5. Each stage can be slid on the pair of the rails, and the tilt of the stage can be tuned with the micrometer heads. The procedures of the alignment and gluing are the followings: (1) Insert shims between the quartz joints to adjust the gap for glue. (2) Adjust surface positions of the quartz parts using a laser displacement sensor. (3) Adjust surface angles of the quartz parts using an autocollimator. (4) Iterate 2 and 3 several times until the required alignment is achieved. (5) Tape the quartz joints to make a dam and apply epoxy (EPOTEK 301-2) into the dam. The achieved horizontal and vertical deflection angle of the quartz joints was within ±40 and ±20 arcsec, respectively. After the glue fully cures, the quartz optics is moved into a quartz bar box (QBB). As it is important to keep the quartz optics flat, the QBB needs high rigidity. On the other hand it is also important to have low mass for the experiment. Therefore the QBB is composed of aluminum honeycomb panels on the inner and outer faces for low mass and side rails made of monolithic aluminum from end to end of the QBB for high rigidity as shown in Fig. 6 (left). To increase the rigidity, the honeycomb panels are round shaped. The quartz optics is supported by PEEK buttons. The button height is tuned precisely with ring shims or bond thickness according to the optics alignment. The standard deviation of the height difference of the PEEK buttons on each honeycomb panel was kept within 0.02 mm. For handling, the QBB is attached on a truss support called strong back as shown in Fig. 6 (right). With the strong back, the module sag can be kept Outer honeycomb panel Quartz bar QBB PEEK button Inner honeycomb panel Side rail Strong back Figure 6: Cross-sectional view of the QBB (left) and the assembled TOP counter module with the strong back (right). 4

Pogo pin Board stacks Silicone cookies LEDs CCD cameras Prism Board stack PMT modules Figure 7: Schematic view of the readout part of the TOP counter (left) and a picture showing the installed board stacks, where only two of four board stacks can be seen from the opening (right). below 0.5 mm, which is necessary to securely support the quartz optics. Lastly 32 MCP-PMTs and four readout board stacks are mounted on each TOP counter module from the opening of the enclosure as shown in Fig. 7. Four MCP-PMTs are assembled in a PMT module, and eight PMT modules are attached to the prism. In each PMT module the MCP-PMT windows are glued on a wavelength filter which cuts wavelengths below 340 nm. The wavelength filter suppresses deterioration of the time resolution due to chromatic dispersion of the Cherenkov photons. To have a good optical contact between the wavelength filter and the prism as well as to make the PMT module replaceable, a soft cast silicone cookie is inserted. Just by pushing the silicone cookie with the PMT module, a bubble free contact can be made. It can be checked by the CCD cameras which view the photocathodes through the prism. The PMT module is interfaced to the board stack by spring-loaded electrical contacts (Pogo pins). 3.2 Installation of the TOP counter The TOP counter modules were installed into the Belle II structure one-by-one. The first module was installed on 10 February 2016. A dedicated jig shown in Fig. 8 was built for the installation: The strong back was connected to the slider on the guide pipe; The module was slid into the barrel; Then it was rotated and approached to the position onto the sidewall. Some special Module + Strong back XY-stage Slider Guide pipe Counter weight Figure 8: Schematic view of the installation jig (left) and a picture showing the third module being installed (right). 5

Construction of the Belle II TOP counter cares were given to the design of this installation jig to keep the maximum sag below 0.5 mm. The sag was monitored during the installation and it was confirmed to be less than 0.5 mm. The last sixteenth module was installed on 11 May 2016. Side-by-side modules were joined by 2.65 m long aluminum z-beams for structural integrity. Finally we came to the memorial day of 20 May 2016 when the strong backs were removed and the installation was completed successfully as shown in Fig. 9. The commissioning and calibration of the installed modules are ongoing toward the phase 2 operation for the SuperKEKB commissioning with the Belle II detector from January 2018 and the physics data taking from December 2018. 4. Summary The TOP counter is one of the key devices in the Belle II experiment. After the long R&D of more than a decade and the production and construction for two to three years, we finally succeeded in producing the 32 quartz bars and two spares as well as the other optics, producing the 512 MCPPMTs and more than 60 spares, extending the MCP-PMT lifetime, assembling the 16 TOP counter modules and a spare, and installing them into the Belle II detector. That is one of the biggest milestones of the Belle II detector construction. Acknowledgement This work was supported by MEXT Grant-in-Aid for Scientific Research on Innovative Areas Elucidation of New Hadrons with a Variety of Flavors and JSPS Grant-in-Aid for Scientific Research (S) Probing New Physics with Tau-Lepton (No. 26220706). 6 Figure 9: Belle II detector fully equipped with the 16 TOP counter modules.

References [1] Ed. A.J. Bevan, B. Golob, Th. Mannel, S. Prell, and B.D. Yabsley, Eur. Phys. J. C 74 (2014) 3026, SLAC-PUB-15968, KEK Preprint 2014-3. [2] T. Abe, et al., KEK-REPORT-2010-1, 2010. [3] Y. Ohnishi, et al., Prog. Theor. Exp. Phys. (2013) 2013 (3): 03A011. [4] T. Ohshima, ICFA Instrumentation Bulletin 20 (2000) 10. [5] M. Akatsu, et al., Nucl. Instr. and Meth. A 440 (2000) 124. [6] T. Ohshima, Nucl. Instr. and Meth. A 453 (2000) 331. [7] Y. Enari, et al., Nucl. Instr. and Meth. A 494 (2002) 430. [8] E. Nakano, Nucl. Instr. and Meth. A 494 (2002) 402. [9] M. Akatsu, et al., Nucl. Instr. and Meth. A 528 (2004) 763. [10] Y. Enari, et al., Nucl. Instr. and Meth. A 547 (2005) 490. [11] N. Kishimoto, et al., Nucl. Instr. and Meth. A 564 (2006) 204. [12] K. Inami, et al., Nucl. Instr. and Meth. A 592 (2008) 247. [13] T. Jinno, et al., Nucl. Instr. and Meth. A 629 (2011) 111. [14], et al., Nucl. Instr. and Meth. A 766 (2014) 148. [15], For the Belle II PID Group, Nucl. Instr. and Meth. A 732 (2013) 357. [16], For the Belle II PID group, PoS(TIPP2014)093. [17], et al., Nucl. Instr. and Meth. A, in press, http://dx.doi.org/10.1016/j.nima.2017.02.010. [18] M. Andrew, PoS(TIPP2014)171. 7