IES LM MEASUREMENT AND TEST REPORT. For

Similar documents
IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

Morris Products 53 Carey Road, Queensbury, NY 12804

TEST REPORT For Company:

IES LM MEASUREMENT AND TEST REPORT For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

IES LM TEST REPORT For EIKO GLOBAL, LLC

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

Test report of IES LM Approved Method: Electrical and Photometric

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

ENERGY STAR PROGRAM REQUIREMENTS FOR LUMINAIRES (LIGHT FIXTURES) (VERSION 2.0) MEASUREMENT AND TEST REPORT For

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

Cat# LED Linear High Bay 100W

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Photometric Test Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

GM LIGHTING 9830 W 190th St, Torrance, CA 90503

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

Transcription:

IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB10W27-50K-D-T5-A-P Report Type: Test Engineer: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, THD, Power Factor Daniel Duan Report Number: RSZ160311515-10 Test Date: 2016-03-18 to 2016-03-21 Report Date: 2016-04-02 Reviewed By: Prepared By: Test Facility: Jeanne Han/Safety Manager Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0. STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

1. Product Description General Information: Manufacturer: Brand Name: Product Designation: Dimmable: Burning Time Before Test: WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED WISDOM Outdoor Pole/Arm-mounted Area and Roadway Luminaires Architectural Flood and Spot Luminaires Non-Dimmable 0 hour(for New Products) Rated Values: Rated Voltage/Frequency: 120-277V AC 60Hz Rated Power: 100W Nominal Light Output: 12000 lm Nominal CCT: 5000K Nominal CRI: 80 2. Standards Used IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits Related Power Quality Requirements for Lighting 3. Description of Test Equipment Device Manufacture Model No Serial No Test Range Integrating Sphere Spectral photometer Calibration Calibration date due date SENSING SPR-600 S09008 25~50 2016-03-10 2017-03-09 SENSING SPR3000 90902027 350nm~800nm 2016-03-10 2017-03-09 Power Meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/600 V 2016-03-04 2017-03-03 AC Power Supply Standard Light Source ALL Power One sample was received on 2016-03-11 and used for testing. Sample No.: RSZ160311515-S01 Model: WSD- SB10W27-50K-D-T5-A-P Model Tested: WSD-SB10W27-50K-D-T5-A-P APW- 105N 970663 220V±10% 50HZ 2016-03-04 2017-03-03 EVERFINE D204 01331191 24V/100W 2015-08-27 2016-08-26 Thermal Meter SENSING N/A N/A 25 50 2016-03-10 2017-03-09 DC Power Supply AC Power Supply DC Power Supply ITECH EVERFINE IT6154 VPS1030 PWM 0061 0417 6471 0010 19 0~32V 2016-03-04 2017-03-03 1012017 0-150V, 0-300V 2016-03-04 2017-03-03 EVERFINE WY12010 1009009 30V/5A 2016-03-04 2017-03-03 Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2016-03-04 2017-03-03 Goniophotometer EVERFINE GO-R5000 YG108492N10120001 1600mm,3000W/10A 2016-03-10 2017-03-09 Report No. RSZ160311515-10 Page 2 of 13 The NVLAP Lab Code is 200707-0.

Device Manufacture Model No Serial No Test Range Wireless Remote Sensor Calibration Calibration date due date N/A 433MHz N/A 0 ~50 ;-20 ~60 2015-03-24 2016-03-23 Standard Light EVERFINE D908 1012003 N/A 2015-09-08 2016-09-07 Source Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI). 4. Test Method Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25 C±1 C during measurement. And relative humidity is less than 65%. Integrating Sphere System The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. The system and standard light source has been calibrated regularly and traceable to the National Primary Standards. 4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1 (K=2), at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Goniophotometer System The goniophotometer system is calibrated by standard light source before measurement. The standard light source has been calibrated regularly and traceable to the National Primary Standards. Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the luminous intensity is U=1.6% (K=2), at the 95% confidence level. Additional Test The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25 C±1 C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Report No. RSZ160311515-10 Page 3 of 13 The NVLAP Lab Code is 200707-0.

5. Test Result [Integrating Sphere System] Total operating time for integrating sphere test: 1.5 hours Test orientation: Downward Electrical Measurement Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor 120.12 60 0.8332 99.9 0.998 Photometric Measurement Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/w) CCT (K) Duv 11070.27 34.418 110.814 4944 0.0023 Chromaticity Coordinate x y u v u' v' 0.3472 0.3579 0.2104 0.3253 0.2104 0.4880 Color Rendering Index Ra 82.5 R1 R2 R3 R4 81 87 92 82 R5 R6 R7 R8 81 82 88 68 R9 R10 R11 R12 8 69 81 57 R13 R14 R15 83 95 75 Report No. RSZ160311515-10 Page 4 of 13 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution 1.2 1.0 0.8 0.6 0.4 0.2 0.0 380 440 500 560 620 680 740 800 nm mw nm mw nm mw nm mw nm mw 380 1.300E-02 465 4.343E-01 550 6.094E-01 635 4.174E-01 720 4.380E-02 385 1.073E-02 470 3.264E-01 555 6.174E-01 640 3.822E-01 725 3.716E-02 390 6.552E-03 475 2.582E-01 560 6.295E-01 645 3.450E-01 730 3.240E-02 395 4.803E-03 480 2.443E-01 565 6.327E-01 650 3.115E-01 735 2.823E-02 400 4.736E-03 485 2.588E-01 570 6.460E-01 655 2.772E-01 740 2.341E-02 405 5.553E-03 490 2.923E-01 575 6.476E-01 660 2.441E-01 745 2.043E-02 410 1.061E-02 495 3.392E-01 580 6.529E-01 665 2.147E-01 750 1.798E-02 415 2.193E-02 500 3.930E-01 585 6.514E-01 670 1.899E-01 755 1.597E-02 420 4.364E-02 505 4.397E-01 590 6.491E-01 675 1.646E-01 760 1.386E-02 425 8.522E-02 510 4.775E-01 595 6.420E-01 680 1.425E-01 765 1.226E-02 430 1.622E-01 515 5.089E-01 600 6.262E-01 685 1.232E-01 770 1.084E-02 435 3.020E-01 520 5.328E-01 605 6.100E-01 690 1.078E-01 775 9.331E-03 440 5.388E-01 525 5.549E-01 610 5.888E-01 695 9.250E-02 780 8.368E-03 445 8.789E-01 530 5.680E-01 615 5.581E-01 700 8.053E-02 450 1.029E+00 535 5.786E-01 620 5.287E-01 705 6.869E-02 455 7.967E-01 540 5.895E-01 625 4.927E-01 710 5.872E-02 460 5.669E-01 545 5.979E-01 630 4.541E-01 715 5.059E-02 Report No. RSZ160311515-10 Page 5 of 13 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 7-Step & 4-Step Chromaticity Quadrangles 0.45 0.40 0.35 0.30 0.30 0.35 0.40 0.45 0.50 0.55 sample 7-STEP 2200K 7-STEP 2500K 7-STEP 2700K 7-STEP 3000K 7-STEP 3500K 7-STEP 4000K 7-STEP 4500K 7-STEP 5000K 7-STEP 5700K 7-STEP 6500K Report No. RSZ160311515-10 Page 6 of 13 The NVLAP Lab Code is 200707-0.

[Goniophotometer System] Total operating time for luminous intensity distribution: 1.0 hour Test orientation: Downward Electrical Measurement Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor 120.03 60 0.8352 100.1 0.9985 Photometric Measurement Luminous Flux (lm) Efficacy (lm/w) I max (cd) S/MH (C0/180) S/MH (C90/270) 11166.5 111.55 3194 2.60 2.63 Luminous Intensity Distribution C0/180 C45/225 C90/270 C135/315 AVG. Beam Angle (50% Imax): 158.8 156.7 158.6 156.7 157.7 Field Angle (10% Imax): 171.0 172.6 171.3 172.7 171.9 Report No. RSZ160311515-10 Page 7 of 13 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data γ C Bay Area Compliance Laboratories Corp. (Shenzhen) 0 22.5 45 67.5 90 112.5 135 157.5 0.0 1275 1275 1275 1275 1275 1275 1275 1275 5.0 1286 1286 1284 1284 1284 1286 1289 1291 10.0 1323 1320 1314 1311 1311 1314 1321 1332 15.0 1389 1380 1367 1364 1365 1365 1375 1398 20.0 1486 1469 1446 1449 1454 1449 1458 1496 25.0 1620 1596 1566 1575 1583 1576 1584 1635 30.0 1817 1789 1750 1761 1769 1757 1768 1833 35.0 2054 2003 1945 1964 1982 1963 1967 2046 40.0 2247 2199 2148 2167 2174 2166 2171 2246 45.0 2510 2446 2387 2405 2414 2412 2414 2498 50.0 2829 2718 2631 2665 2715 2696 2677 2789 55.0 3105 2951 2828 2886 2993 2947 2897 3032 60.0 3090 3018 2965 2958 2966 2998 3010 3017 65.0 2268 2625 2991 2650 2248 2586 2994 2533 70.0 1348 1827 2149 2017 1870 1992 1989 1794 75.0 1373 1195 1014 1302 1518 1267 980 1088 80.0 593 558 509 555 536 529 481 496 85.0 196 216 213 196 145 182 187 175 90.0 1 15 2 1 17 30 18 1 95.0 1 1 1 1 1 1 1 1 100.0 1 2 2 2 2 2 2 2 105.0 2 2 2 2 2 2 2 2 110.0 2 2 2 2 2 2 2 2 115.0 2 2 2 2 2 2 2 2 120.0 2 1 1 2 1 2 1 2 125.0 2 1 1 2 1 2 2 2 130.0 2 2 1 2 2 2 2 2 135.0 2 2 2 2 2 2 2 2 140.0 2 2 2 2 2 2 2 2 145.0 2 2 2 2 2 2 2 2 150.0 2 2 2 2 2 2 2 2 155.0 2 2 2 2 2 2 2 2 160.0 2 2 2 2 2 2 2 2 165.0 2 2 2 2 2 2 2 2 170.0 2 2 2 2 2 2 2 2 175.0 2 2 2 2 2 2 2 2 180.0 2 2 2 1 1 2 2 2 Report No. RSZ160311515-10 Page 8 of 13 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.) γ C Bay Area Compliance Laboratories Corp. (Shenzhen) 180 202.5 225 247.5 270 292.5 315 337.5 0.0 1275 1275 1275 1275 1275 1275 1275 1275 5.0 1291 1288 1285 1281 1279 1278 1280 1282 10.0 1334 1328 1315 1304 1297 1298 1305 1314 15.0 1406 1395 1369 1350 1343 1345 1355 1372 20.0 1512 1493 1450 1430 1426 1424 1431 1459 25.0 1654 1630 1573 1550 1551 1541 1540 1579 30.0 1857 1830 1760 1730 1727 1707 1701 1756 35.0 2092 2051 1970 1941 1944 1918 1906 1981 40.0 2295 2252 2177 2149 2138 2109 2097 2172 45.0 2560 2492 2406 2390 2374 2340 2333 2412 50.0 2858 2759 2649 2660 2686 2643 2605 2708 55.0 3111 3005 2882 2935 3029 2958 2870 2994 60.0 3052 3071 3049 3099 3185 3144 3068 3115 65.0 2159 2580 3097 2912 2575 2902 3148 2704 70.0 1427 1712 2251 2188 1825 2230 2469 1836 75.0 1317 1197 1076 1369 1636 1438 1137 1321 80.0 554 531 506 553 576 581 542 587 85.0 156 186 182 194 163 202 212 228 90.0 1 1 1 1 1 1 1 1 95.0 1 1 1 1 1 1 1 1 100.0 1 1 1 1 1 1 1 1 105.0 1 1 1 1 1 1 1 1 110.0 1 1 1 1 1 1 1 1 115.0 1 1 1 1 1 1 1 1 120.0 2 1 1 2 1 1 1 1 125.0 2 2 2 2 2 2 2 2 130.0 2 2 2 2 2 2 2 2 135.0 2 2 2 2 2 2 2 2 140.0 2 2 2 2 2 2 2 2 145.0 2 2 2 2 2 2 2 2 150.0 1 1 1 1 1 1 1 2 155.0 1 1 1 1 1 1 1 2 160.0 1 1 1 1 1 1 1 1 165.0 1 1 1 1 1 1 1 1 170.0 1 1 1 1 1 1 1 1 175.0 2 2 2 2 1 1 1 2 180.0 2 2 2 2 2 2 2 2 Report No. RSZ160311515-10 Page 9 of 13 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure Angle: 157.7. Flux out: 10864.0 lm. Height (m) Diameter (cm) E avg (lx) E max (lx) 0.5 507.36 522.6 5135.0 1.0 1014.72 130.7 1284.0 1.5 1522.08 58.1 570.5 2.0 2029.44 32.7 320.9 2.5 2536.80 20.9 205.4 3.0 3044.16 14.5 142.6 3.5 3551.52 10.7 104.8 4.0 4058.88 8.2 80.2 4.5 4566.24 6.5 63.4 5.0 5073.60 5.2 51.4 Report No. RSZ160311515-10 Page 10 of 13 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement Deg Flux (lm) % Deg Flux (lm) % 0-5 30.6 0.27 0-5 30.6 0.27 5-10 93.0 0.84 0-10 123.6 1.11 10-15 159.3 1.42 0-15 282.9 2.53 15-20 233.1 2.09 0-20 515.9 4.62 20-25 318.8 2.86 0-25 834.7 7.48 25-30 423.7 3.79 0-30 1258.5 11.27 30-35 553.8 4.96 0-35 1812.3 16.23 35-40 695.1 6.22 0-40 2507.4 22.45 40-45 851.8 7.63 0-45 3359.2 30.08 45-50 1036.9 9.29 0-50 4396.2 39.37 50-55 1235.7 11.06 0-55 5631.8 50.43 55-60 1401.0 12.55 0-60 7032.8 62.98 60-65 1417.4 12.69 0-65 8450.2 75.67 65-70 1164.7 10.43 0-70 9614.9 86.10 70-75 856.5 7.67 0-75 10471.3 93.77 75-80 455.9 4.09 0-80 10927.2 97.86 80-85 190.7 1.70 0-85 11117.9 99.56 85-90 38.9 0.35 0-90 11156.8 99.91 90-95 0.9 0.01 0-95 11157.7 99.92 95-100 0.6 0.01 0-100 11158.3 99.93 100-105 0.7 0.00 0-105 11159.0 99.93 105-110 0.7 0.01 0-110 11159.8 99.94 110-115 0.7 0.01 0-115 11160.5 99.95 115-120 0.7 0.00 0-120 11161.2 99.95 120-125 0.7 0.01 0-125 11161.9 99.96 125-130 0.7 0.01 0-130 11162.7 99.97 130-135 0.7 0.00 0-135 11163.3 99.97 135-140 0.6 0.01 0-140 11164.0 99.98 140-145 0.6 0.00 0-145 11164.6 99.98 145-150 0.5 0.01 0-150 11165.1 99.99 150-155 0.4 0.00 0-155 11165.5 99.99 155-160 0.4 0.00 0-160 11165.9 99.99 160-165 0.3 0.01 0-165 11166.2 100.00 165-170 0.2 0.00 0-170 11166.4 100.00 170-175 0.1 0.00 0-175 11166.5 100.00 175-180 0.0 0.00 0-180 11166.5 100.00 Report No. RSZ160311515-10 Page 11 of 13 The NVLAP Lab Code is 200707-0.

[Additional Test] Test Item Test Voltage (V) Frequency (Hz) Test Result Power Factor: 277.0 60 0.9859 Total Harmonic Distortion: 277.0 60 16.89% Total Harmonic Distortion: 120.0 60 3.75% 6. Product Photo Report No. RSZ160311515-10 Page 12 of 13 The NVLAP Lab Code is 200707-0.

7. Product Test orientation in the Goniophotometer ***********END OF REPORT*********** Report No. RSZ160311515-10 Page 13 of 13 The NVLAP Lab Code is 200707-0.