IES LM MEASUREMENT AND TEST REPORT. For

Similar documents
IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

Morris Products 53 Carey Road, Queensbury, NY 12804

TEST REPORT For Company:

IES LM MEASUREMENT AND TEST REPORT For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

IES LM TEST REPORT For EIKO GLOBAL, LLC

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

Test report of IES LM Approved Method: Electrical and Photometric

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

ENERGY STAR PROGRAM REQUIREMENTS FOR LUMINAIRES (LIGHT FIXTURES) (VERSION 2.0) MEASUREMENT AND TEST REPORT For

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

Cat# LED Linear High Bay 100W

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W LED FlatPanel Slipfitter Mount. EPA Rating 2.

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Photometric Test Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

GM LIGHTING 9830 W 190th St, Torrance, CA 90503

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: N/A) 911 Denison St Markham, ON L3R 3K4 Canada

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

Transcription:

IES LM-79-08 MEASUREMENT AND TEST REPORT For WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED Floor 8,B2 Building,YangGuangn Industrial Park, Bao An District,ShenZhen,China Test Model: WSD-SB06W27-50K-D-T5-A-P Report Type: Test Engineer: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, THD, Power Factor Daniel Duan Report Number: RSZ160311513-10 Test Date: 2016-03-18 to 2016-03-21 Report Date: 2016-03-22 Reviewed By: Prepared By: Test Facility: Jeanne Han/Safety Manager Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0. STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

1. Product Description General Information: One sample was received on 2016-03-11 and used for testing. Sample No.: RSZ160311513-S01 Model: WSD- SB06W27-50K-D-T5-A-P Model Tested: WSD-SB06W27-50K-D-T5-A-P Manufacturer: Brand Name: Product Designation: Dimmable: Burning Time Before Test: WISDOM OPTOELECTRONICS TECHNOLOGY CO., LIMITED WISDOM Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Architectural Flood and Spot Luminaires Non-Dimmable 0 hour(for New Products) Rated Values: Rated Voltage/Frequency: AC120-277V 60Hz Rated Power: 60W Nominal Light Output: 7200 lm Nominal CCT: 5000K Nominal CRI: 80 2. Standards Used IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits Related Power Quality Requirements for Lighting 3. Description of Test Equipment Device Manufacture Model No Serial No Test Range Integrating Sphere Spectral photometer Calibration Calibration date due date SENSING SPR-600 S09008 25~50 2016-03-10 2017-03-09 SENSING SPR3000 90902027 350nm~800nm 2016-03-10 2017-03-09 Power Meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/600 V 2016-03-04 2017-03-03 AC Power Supply ALL Power APW-105N 970663 220V±10% 50HZ 2016-03-04 2017-03-03 Standard Light Source EVERFINE D204 01331191 24V/100W 2015-08-27 2016-08-26 Thermal Meter SENSING N/A N/A 25 50 2016-03-10 2017-03-09 DC Power Supply ITECH AC Power Supply EVERFINE DC Power Supply IT6154 VPS1030 PWM 0061 0417 6471 0010 19 0~32V 2016-03-04 2017-03-03 1012017 0-150V, 0-300V 2016-03-04 2017-03-03 EVERFINE WY12010 1009009 30V/5A 2016-03-04 2017-03-03 Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2016-03-04 2017-03-03 Goniophotometer EVERFINE GO-R5000 YG108492N10120001 1600mm,3000W/10A 2016-03-10 2017-03-09 Wireless Remote Sensor N/A 433MHz N/A 0 ~50 ;-20 ~60 2015-03-24 2016-03-23 Report No. RSZ160311513-10 Page 2 of 13 The NVLAP Lab Code is 200707-0.

Device Manufacture Model No Serial No Test Range Calibration Calibration date due date Standard Light Source EVERFINE D908 1012003 N/A 2015-09-08 2016-09-07 Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI). 4. Test Method Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25 C±1 C during measurement. And relative humidity is less than 65%. Integrating Sphere System The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. The system and standard light source has been calibrated regularly and traceable to the National Primary Standards. 4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1 (K=2), at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Goniophotometer System The goniophotometer system is calibrated by standard light source before measurement. The standard light source has been calibrated regularly and traceable to the National Primary Standards. Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the luminous intensity is U=2.82% (K=2), at the 95% confidence level. Additional Test The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25 C±1 C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Report No. RSZ160311513-10 Page 3 of 13 The NVLAP Lab Code is 200707-0.

5. Test Result [Integrating Sphere System] Total operating time for integrating sphere test: 1.0 hours Test orientation: Downward Electrical Measurement Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor 120.13 60 0.5162 61.8 0.997 Photometric Measurement Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/w) CCT (K) Duv 7678.412 23.786 124.246 4896 0.00255 Chromaticity Coordinate x y u v u' v' 0.3487 0.3596 0.2108 0.3260 0.2108 0.4891 Color Rendering Index Ra 82.6 R1 R2 R3 R4 81 87 92 83 R5 R6 R7 R8 81 82 88 68 R9 R10 R11 R12 9 69 81 57 R13 R14 R15 83 95 75 Report No. RSZ160311513-10 Page 4 of 13 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution 1.2 1.0 0.8 0.6 0.4 0.2 0.0 380 440 500 560 620 680 740 800 nm mw nm mw nm mw nm mw nm mw 380 8.693E-03 465 3.051E-01 550 4.371E-01 635 3.033E-01 720 3.136E-02 385 6.995E-03 470 2.256E-01 555 4.434E-01 640 2.772E-01 725 2.584E-02 390 5.020E-03 475 1.775E-01 560 4.509E-01 645 2.495E-01 730 2.308E-02 395 3.961E-03 480 1.708E-01 565 4.525E-01 650 2.259E-01 735 1.973E-02 400 3.236E-03 485 1.818E-01 570 4.609E-01 655 2.005E-01 740 1.705E-02 405 3.540E-03 490 2.074E-01 575 4.623E-01 660 1.769E-01 745 1.477E-02 410 6.087E-03 495 2.419E-01 580 4.677E-01 665 1.559E-01 750 1.287E-02 415 1.231E-02 500 2.825E-01 585 4.674E-01 670 1.357E-01 755 1.121E-02 420 2.481E-02 505 3.164E-01 590 4.656E-01 675 1.183E-01 760 1.001E-02 425 5.029E-02 510 3.447E-01 595 4.619E-01 680 1.028E-01 765 8.527E-03 430 1.012E-01 515 3.664E-01 600 4.508E-01 685 8.944E-02 770 7.495E-03 435 1.985E-01 520 3.838E-01 605 4.390E-01 690 7.784E-02 775 6.798E-03 440 3.774E-01 525 3.992E-01 610 4.257E-01 695 6.602E-02 780 5.965E-03 445 6.423E-01 530 4.082E-01 615 4.026E-01 700 5.728E-02 450 7.530E-01 535 4.163E-01 620 3.825E-01 705 4.896E-02 455 5.612E-01 540 4.219E-01 625 3.590E-01 710 4.181E-02 460 3.960E-01 545 4.279E-01 630 3.298E-01 715 3.575E-02 Report No. RSZ160311513-10 Page 5 of 13 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 7-Step & 4-Step Chromaticity Quadrangles 0.45 0.40 0.35 0.30 0.30 0.35 0.40 0.45 0.50 0.55 sample 7-STEP 2200K 7-STEP 2500K 7-STEP 2700K 7-STEP 3000K 7-STEP 3500K 7-STEP 4000K 7-STEP 4500K 7-STEP 5000K 7-STEP 5700K 7-STEP 6500K Report No. RSZ160311513-10 Page 6 of 13 The NVLAP Lab Code is 200707-0.

[Goniophotometer System] Total operating time for luminous intensity distribution: 1.0 hours Test orientation: Downward Electrical Measurement Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor 120.14 60 0.5243 62.0 0.9843 Photometric Measurement Luminous Flux (lm) Efficacy (lm/w) I max (cd) S/MH (C0/180) S/MH (C90/270) 7712.6 124.40 2235 2.59 2.66 Luminous Intensity Distribution C0/180 C45/225 C90/270 C135/315 AVG. Beam Angle (50% Imax): 158.4 156.6 158.4 156.7 157.5 Field Angle (10% Imax): 171.4 172.7 170.9 172.8 172.0 Report No. RSZ160311513-10 Page 7 of 13 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data γ C Bay Area Compliance Laboratories Corp. (Shenzhen) 0 22.5 45 67.5 90 112.5 135 157.5 0.0 884 884 884 884 884 884 884 884 5.0 892 884 891 885 886 893 898 899 10.0 910 908 905 905 904 909 916 923 15.0 955 947 940 936 942 946 955 971 20.0 1019 1002 992 995 998 1001 1012 1035 25.0 1105 1087 1070 1080 1095 1096 1103 1136 30.0 1239 1209 1200 1210 1227 1229 1239 1279 35.0 1387 1352 1324 1347 1366 1364 1368 1421 40.0 1520 1477 1466 1479 1502 1512 1518 1566 45.0 1687 1643 1617 1648 1666 1678 1677 1734 50.0 1903 1823 1786 1817 1874 1875 1863 1941 55.0 2088 1991 1942 1984 2044 2034 2009 2096 60.0 2102 2054 2042 2037 2039 2059 2091 2091 65.0 1607 1820 2043 1826 1576 1799 2069 1758 70.0 978 1295 1521 1384 1272 1373 1347 1229 75.0 961 839 740 911 1018 863 689 762 80.0 404 373 344 381 347 349 325 325 85.0 132 148 144 133 98 124 127 119 90.0 1 1 1 1 15 17 13 1 95.0 1 1 1 1 1 1 1 1 100.0 1 1 1 1 1 1 1 1 105.0 1 1 1 1 1 1 1 1 110.0 1 1 1 1 1 1 1 1 115.0 1 1 1 1 1 1 1 1 120.0 1 1 1 1 1 1 1 1 125.0 1 1 1 1 1 1 1 1 130.0 1 1 1 1 1 1 1 1 135.0 1 1 1 1 1 1 1 1 140.0 1 1 1 1 1 1 1 1 145.0 1 1 1 1 1 1 1 1 150.0 1 1 1 1 1 1 1 1 155.0 2 2 1 1 1 1 1 1 160.0 1 1 1 1 1 1 1 1 165.0 1 1 1 1 1 1 1 1 170.0 1 1 1 1 1 1 1 1 175.0 1 1 1 1 1 1 1 1 180.0 1 1 1 1 1 1 1 1 Report No. RSZ160311513-10 Page 8 of 13 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.) γ C Bay Area Compliance Laboratories Corp. (Shenzhen) 180 202.5 225 247.5 270 292.5 315 337.5 0.0 884 884 884 884 884 884 884 884 5.0 898 891 895 889 884 887 889 887 10.0 927 920 914 902 901 902 904 908 15.0 974 965 950 937 928 931 935 943 20.0 1051 1032 1010 989 989 990 990 1004 25.0 1147 1131 1092 1079 1076 1068 1059 1080 30.0 1299 1269 1233 1204 1201 1190 1180 1206 35.0 1460 1433 1379 1364 1364 1339 1317 1351 40.0 1600 1559 1524 1504 1495 1474 1455 1480 45.0 1781 1727 1682 1669 1665 1637 1606 1635 50.0 1985 1919 1859 1871 1877 1835 1784 1818 55.0 2173 2095 2029 2065 2132 2057 1959 2014 60.0 2111 2145 2145 2192 2229 2172 2083 2101 65.0 1462 1772 2192 1997 1743 1989 2159 1884 70.0 1088 1255 1516 1493 1230 1489 1710 1320 75.0 912 822 742 924 1103 1010 807 930 80.0 362 349 340 367 382 401 374 401 85.0 117 121 132 137 108 146 155 157 90.0 0 0 0 0 0 0 0 1 95.0 1 1 1 1 1 1 1 0 100.0 1 1 1 1 1 1 1 1 105.0 1 1 1 1 1 1 1 1 110.0 1 1 1 1 1 1 1 1 115.0 1 1 1 1 1 1 1 1 120.0 1 1 1 1 1 1 1 1 125.0 1 1 1 1 1 1 1 1 130.0 1 1 1 1 1 1 1 1 135.0 1 1 1 1 1 1 1 1 140.0 1 1 1 1 1 1 1 1 145.0 1 1 1 1 1 1 1 1 150.0 1 1 1 1 1 1 1 1 155.0 1 1 1 1 1 1 1 1 160.0 1 1 1 1 1 1 1 1 165.0 1 1 1 1 1 1 1 1 170.0 1 1 1 1 1 1 1 1 175.0 1 1 1 1 1 1 1 1 180.0 1 1 1 1 1 1 1 1 Report No. RSZ160311513-10 Page 9 of 13 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure Angle: 157.5. Flux out: 7505.0 lm. Height (m) Diameter (cm) E avg (lx) E max (lx) 0.5 502.73 361.1 3554.0 1.0 1005.47 90.3 888.6 1.5 1508.20 40.1 394.9 2.0 2010.94 22.6 222.1 2.5 2513.67 14.4 142.2 3.0 3016.40 10.0 98.7 3.5 3519.14 7.4 72.5 4.0 4021.87 5.6 55.5 4.5 4524.61 4.5 43.9 5.0 5027.34 3.6 35.5 Report No. RSZ160311513-10 Page 10 of 13 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement Deg Flux (lm) % Deg Flux (lm) % 0-5 21.2 0.28 0-5 21.2 0.28 5-10 64.4 0.83 0-10 85.6 1.11 10-15 110.2 1.43 0-15 195.8 2.54 15-20 160.9 2.08 0-20 356.7 4.62 20-25 220.1 2.86 0-25 576.8 7.48 25-30 293.0 3.80 0-30 869.8 11.28 30-35 383.3 4.97 0-35 1253.1 16.25 35-40 480.7 6.23 0-40 1733.7 22.48 40-45 588.0 7.62 0-45 2321.7 30.10 45-50 715.0 9.27 0-50 3036.7 39.37 50-55 851.6 11.05 0-55 3888.3 50.42 55-60 967.2 12.54 0-60 4855.5 62.96 60-65 978.9 12.69 0-65 5834.4 75.65 65-70 805.4 10.44 0-70 6639.9 86.09 70-75 597.0 7.74 0-75 7236.9 93.83 75-80 311.5 4.04 0-80 7548.4 97.87 80-85 129.0 1.67 0-85 7677.4 99.54 85-90 28.6 0.37 0-90 7706.0 99.91 90-95 0.5 0.01 0-95 7706.5 99.92 95-100 0.4 0.01 0-100 7707.0 99.93 100-105 0.5 0.00 0-105 7707.5 99.93 105-110 0.5 0.01 0-110 7708.0 99.94 110-115 0.5 0.01 0-115 7708.5 99.95 115-120 0.5 0.00 0-120 7709.0 99.95 120-125 0.5 0.01 0-125 7709.5 99.96 125-130 0.5 0.01 0-130 7709.9 99.97 130-135 0.5 0.00 0-135 7710.4 99.97 135-140 0.4 0.01 0-140 7710.9 99.98 140-145 0.4 0.00 0-145 7711.3 99.98 145-150 0.4 0.01 0-150 7711.6 99.99 150-155 0.3 0.00 0-155 7711.9 99.99 155-160 0.2 0.00 0-160 7712.2 99.99 160-165 0.2 0.01 0-165 7712.4 100.00 165-170 0.1 0.00 0-170 7712.5 100.00 170-175 0.1 0.00 0-175 7712.6 100.00 175-180 0.0 0.00 0-180 7712.6 100.00 Report No. RSZ160311513-10 Page 11 of 13 The NVLAP Lab Code is 200707-0.

[Additional Test] Test Item Test Voltage (V) Frequency (Hz) Test Result Power Factor: 277.0 60 0.9492 Total Harmonic Distortion: 277.0 60 13.57% Total Harmonic Distortion: 120.0 60 9.97% 6. Product Photo Report No. RSZ160311513-10 Page 12 of 13 The NVLAP Lab Code is 200707-0.

7. Product Test orientation in the Goniophotometer Bay Area Compliance Laboratories Corp. (Shenzhen) ***********END OF REPORT*********** Report No. RSZ160311513-10 Page 13 of 13 The NVLAP Lab Code is 200707-0.