Free Flow Below Skew Sluice Gate

Similar documents
Inclined Rectangular Weir-Flow Modeling

FLOW MODELLING OF INCLINED TRAPEZOIDAL WEIR WITH A NEW APPROACH

Head Discharge Relationship of Thin Plated Rectangular Lab Fabricated Sharp Crested Weirs

Experimental Investigation on the Influence of Density of Fluid. On Efficiency of V- Notch

R09. d water surface. Prove that the depth of pressure is equal to p +.

EFFECT OF BAFFLE BLOCKS ON THE PERFORMANCE OF RADIAL HYDRAULIC JUMP

Discharge Coefficient for Sharp-Crested Side Weir in Supercritical Flow

Formation Of Hydraulic Jumps On Corrugated Beds

FORMATION OF HYDRAULIC JUMPS ON CORRUGATED BEDS

DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING Urban Drainage: Hydraulics. Solutions to problem sheet 2: Flows in open channels

Design of Stilling Basins using Artificial Roughness

This is an author-deposited version published in : Eprints ID : 9010

International Journal of Advance Research, IJOAR.org ISSN

Efficiency of an Expansive Transition in an Open Channel Subcritical Flow

New method for discharge hydrograph measurement of the free overflow with full-width, thin-plate weir

Hydromechanics: Course Summary

UNIT I FLUID PROPERTIES AND STATICS

NPTEL Quiz Hydraulics

EFFECT OF VERTICAL CURVATURE OF FLOW AT WEIR CREST ON DISCHARGE COEFFICIENT

Determination of Crest Coefficient for Flow over Trapezoidal Labyrinth Weir

1.060 Engineering Mechanics II Spring Problem Set 4

Discharge Measurements in Open Channels using Compound Sharp-Crested Weirs

Local Scouring due to Flow Jet at Downstream of Rectangular Sharp-Crested Weirs

Study of Flow Characteristics of Contracted Sharp Crested Rectangular Weir Rahul Pandey 1, Dr.S.K.Mittal 2 and Prof. M.K.

CE 6403 APPLIED HYDRAULIC ENGINEERING UNIT - II GRADUALLY VARIED FLOW

Lateral Inflow into High-Velocity Channels

Flow over oblique Side Weir

Transactions on Engineering Sciences vol 9, 1996 WIT Press, ISSN

Flow Characteristics of Sharp Crested Rectangular Weir: A Review

Hydraulic Characteristics of a Rectangular Weir Combined with Equal and Unequal Size Three Rectangular Bottom Openings

Visualization of flow pattern over or around immersed objects in open channel flow.

ENGINEERING FLUID MECHANICS. CHAPTER 1 Properties of Fluids

10.52 Mechanics of Fluids Spring 2006 Problem Set 3

Dr. Muhammad Ali Shamim ; Internal 652

Comparative Analysis of a Parabolic Weir

Local energy losses at positive and negative steps in subcritical open channel flows

If a stream of uniform velocity flows into a blunt body, the stream lines take a pattern similar to this: Streamlines around a blunt body

Experiment (4): Flow measurement

53:071 Principles of Hydraulics Laboratory Experiment #3 ANALYSIS OF OPEN-CHANNEL FLOW TRANSITIONS USING THE SPECIFIC ENERGY DIAGRAM

Laboratory Investigation of Submerged Vane Shapes Effect on River Banks Protection

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad AERONAUTICAL ENGINEERING QUESTION BANK : AERONAUTICAL ENGINEERING.

MAHATMA GANDHI MISSION S JAWAHARLAL NEHRU ENGINEERING COLLEGE, AURANGABAD. (M.S.)

Behavior of the Discharge Coefficient for the Overflow Characteristics of Oblique Circular Weirs

Lecture 13 Flow Measurement in Pipes. I. Introduction

VARIATION OF MANNING S ROUGHNESS COEFFICIENT WITH SEEPAGE IN SAND-BED CHANNEL *Satish Patel 1 and Bimlesh Kumar 2

Hydraulics Part: Open Channel Flow

MAHATMA GANDHI MISSION S JAWAHARLAL NEHRU ENGINEERING COLLEGE, FLUID MECHANICS LABORATORY MANUAL

Head loss coefficient through sharp-edged orifices

Laboratory experiences on open channel flow (in collaboration with Dr. Ing. Luca Milanesi)

Closed duct flows are full of fluid, have no free surface within, and are driven by a pressure gradient along the duct axis.

New analytical formulation of the De Marchi model for zero height side. weir

DEPARTMENT OF CHEMICAL ENGINEERING University of Engineering & Technology, Lahore. Fluid Mechanics Lab

= 8/15 C1 {2fi Hfr'l (1)

Lecture 10: River Channels

15. GRIT CHAMBER 15.1 Horizontal Velocity in Flow Though Grit Chamber

UNIT IV. Flow through Orifice and Mouthpieces and Flow through Notchs and Weirs

A Study of The Turbulent Flows in Sloping and Adversely Sloping Rectangular Culvert

Approximate physical properties of selected fluids All properties are given at pressure kn/m 2 and temperature 15 C.

Closed duct flows are full of fluid, have no free surface within, and are driven by a pressure gradient along the duct axis.

CVE 372 HYDROMECHANICS EXERCISE PROBLEMS

Chapter 3 Bernoulli Equation

Study of the rate of sediment trapping and water loss in the vortex tube structure at different placement angles

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

DETERMINATION OF DISCHARGE COEFFICIENT FOR FLOW OVER ONE CYCLE COMPOUND TRAPEZOIDAL PLAN FORM LABYRINTH WEIR

Hydraulics. B.E. (Civil), Year/Part: II/II. Tutorial solutions: Pipe flow. Tutorial 1

Measurements using Bernoulli s equation

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

Experimental Investigations of Nappe Profile and Pool Depth for Broad Crested Weirs

CE MECHANICS OF FLUIDS

Development of Discharge Prediction Model for Trapezoidal Canals using Simple Portable Flume

INFLUENCE OF OFF-TAKE ANGLES ON FLOW DISTRIBUTION PATTERN AT CONCAVE CHANNEL BIFURCATION


LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

A note on critical flow section in collector channels

Module 15 : Grit Chamber. Lecture 19 : Grit Chamber

Flow Characteristics and Modelling of Head-discharge Relationships for Weirs

P10.5 Water flows down a rectangular channel that is 4 ft wide and 3 ft deep. The flow rate is 15,000 gal/min. Estimate the Froude number of the flow.

Presented by: Civil Engineering Academy

FLUID MECHANICS. Chapter 3 Elementary Fluid Dynamics - The Bernoulli Equation

Study of Hydraulic Jump Length Coefficient with the Leap Generation by Canal Gate Model

28.2 Classification of Jumps

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Minimum Specific Energy and Critical Flow Conditions in Open Channels

Q1 Give answers to all of the following questions (5 marks each):

EXAMPLES (SEDIMENT TRANSPORT) AUTUMN 2018

Characteristics of flow over the free overfall of triangular channel

AUSTRALIAN JOURNAL OF BASIC AND APPLIED SCIENCES

COMPARISON OF LABORATORY AND FIELD MEASUREMENTS OF BRIDGE PIER SCOUR

Factors affecting confluence scour

Pressure in stationary and moving fluid Lab- Lab On- On Chip: Lecture 2

Keywords: flow characteristics, compound straight channel, bed morphology, floodplain

Sediment Extraction and Flow Structure of Vortex Settling Basin

Fluid Mechanics Testbank By David Admiraal

CFD STUDY OF MASS TRANSFER IN SPACER FILLED MEMBRANE MODULE

SEDIMENTATION INTRODUCTION

Open Channel Hydraulics III - Sharpcrested

Fluid Dynamics Exercises and questions for the course

EFFECT OF CHANNEL BENDS ON TRANSVERSE MIXING

CIE4491 Lecture. Hydraulic design

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

Transcription:

International Journal of Engineering Research and Development e-issn: 2278-67X, p-issn: 2278-8X, www.ijerd.com Volume, Issue 3 (March 24), PP.44-52 Talib Mansoor Civil Engineering Department, Aligarh Muslim University, Aligarh, INDIA Abstract:- The discharge through irrigation canals is commonly controlled by means of sluice gates. Generally they are used as normal sluice gate. But for the purpose of diverting the discharge they are also used as side sluice gates. In order to increase the efficiency of sluice gate it can be placed obliquely to the flow, increasing the effective sluice gate length and hence increasing the discharge for the same upstream water depth, gate opening and channel width. This paper contains the results of experimental study carried out to explore the flow characteristics of skew sluice gates under free flow conditions. A generalized equation in terms of non dimensional discharge and non-dimensional depth has been proposed. An increase in discharging capacity of the skew sluice gate with decrease in skew angle has been ascertained and reduction in afflux using skew sluice gate is highlighted. Keywords:- skew sluice gate, discharge coefficient, afflux reduction, discharging capacity, dimensionless discharge, dimensionless depth. I. INTRODUCTION Sluice gates are widely used for the purpose of measurement, diversion and control of the discharge through the irrigation canals. These are classified into different categories based on different criteria. Based on the downstream water level, they are classified as sluice gate discharging free and submerged sluice gate. Whereas on the basis of alignment with channel axis these are classified as normal sluice gate, if the gate is normal to the axis of the channel, side sluice gate, if the gate is parallel to axis of the channel and skew sluice gate when the gate is inclined to the axis of the channel. Further, a gate inclined with vertical is classified as inclined or planer gate. (Fig. ). x x Y x x PLAN Y PLAN PLAN (a) Normal Sluice Gate Section at X-X (b) Side Sluice Gate Section at Y-Y (c) Skew Sluice Gate Section at X-X (d) Inclined Sluice Gate Section at X-X Fig. Types of Sluice Gates Henry(95) studied the diffusion of submerged jet downstream of a normal sluice gate and developed a useful diagram for discharge coefficient in free and submerged flow conditions. Rajaratnam and Subramanya (967) confirmed the findings of Henry (95). Based on the experimental curves of Henry(95), Swamee(992) proposed equations for both free and submerged flows as well as criterion for submergence. Clemens et al (23) studied submerged radial gates. Spulveda (29) studied various calibration methods for discharge coefficient of submerged sluice gates and suggested a value of contraction coefficient as.6 that gives good results. Ferro (2) carried out experimental study on simultaneous flow over and under a sluice gate. Belaud et al (29) studied the contraction coefficient under free and submerged sluice gates. Monte (997) developed numerical method of solution for inviscid flow under planar sluice gates and suggested that the discrepancy between experimental and theoretical values of contraction coefficient is due to the energy loss associated with the vortex formation at the upstream region of the gate. 44

The side sluice gates and skew sluice gates are often used to divert the discharge in the side channel in irrigation, urban sewage system and during flood operation. Little published work namely Panda (98), Swamee et al (993), and Ghodsian (23) is available on side sluice gates. On skew sluice gates, Swamee et al (2) conducted experimental study under free and submerged flow conditions covering a wide range of hydraulic parameters. The details of the work are also available in Mansoor (999). They proposed equation for elementary discharge coefficient that can be used to compute the discharge through sluice gate having any plan shape. In this paper an attempt has been made to develop a simple generalized equation for discharge coefficient and to investigate the increase in discharging capacity and reduction in afflux with the use of skew sluice gate in free flow conditions. II. DIMENSIONAL ANALYSIS The functional relationship for the discharge, Q through a skew sluice gate can be written as: () where, ρ = Density of water, μ = Kinematic Viscosity of water, g = gravity acceleration, y = water depth at the upstream, B = channel width, σ = surface tension of water, θ = skew angle, and L = length of skew sluice gate. From Eq. () dimensionless ratios that describe the discharge function can be formed as follows: * + (2) The dependent ratio in Eq. (2) is a coefficient of discharge. The first three independent ratios describe the geometry of the flow boundaries, and the last two symbols represent the Reynolds and Weber numbers. Since their effect on discharge is not appreciable, they can be dropped and the coefficient of discharge can be defined as: * + (3) The first ratio L/B is simply a measure of alignment of sluice gate i.e. oblique angle. The second ratio y/l can be described as alignment parameter. Slight increase in sluice gate length, L reduces the upstream depth, y. The last ratio y/a is a measure of the depth contraction characteristic of the sluice gate. Eq. (3) can be written in its general form as: (4) III. EXPERIMENTAL SET -UP Experiments were conducted in a rectangular brick masonry channel plastered with cement. The channel was 9. m long,.5m wide and.6m having nearly horizontal bed. The sharp crested sluice gates were made of 5mm thick mild steel plate and a chamfer of 45 was provide at the downstream face to obtain a crest thickness of mm. These sluice gates were installed at angles θ = 5, 3, 45, 6 and 75 with respect to channel axis. Water was supplied to the channel from an over head tank maintained at constant head using overflow arrangement. Smooth, undisturbed, steady-uniform flow was obtained by making the water to flow through brick screen. Wooden float was tied to brick screen to dampen the surface waves. The experimental set up is shown in Fig. 2. The depth at the upstream of sluice gate was measured using a point gauge (.mm accuracy) located on the channel axis at a distance of about.5m on upstream of the skew sluice gate. Discharge flowing through sluice gate was measured with the help of a calibrated rectangular weir provided at the end of the drain. Water after running through the experimental setup was collected in an underground sump from which it was recirculated by lifting it up to the overhead tank. The range of parameters covered is given in Table - I. S. No. Skew angle θ (rad) Table I Range of parameters Gate opening Discharge a Q (m) (m 3 /s) Depth y (m) No. of runs π/4..6.5.62.77.572 77 2 π/3..5.4.53.6.562 2 3 5π/2..5.4.45.86.574 87 45

Drain X.5 m Main Channel X Wooden Float Skew Sluice Gate Inlet Pipe Grid Walls 9. m.6 m Plan Skew Sluice Gate.6 m deep Section at X-X Fig.2 Experimental Set-up IV. ANALYSIS OF DATA AND DISCUSSION Experimental data collected in the laboratory for various skew sluice gates have been analysed to study the effects of various flow and geometrical parameters on discharge coefficient. Variation of Q with upstream depth y is depicted in Figs. 3-5. From these graphs it is clear that there is a separate curves for each gate opening a with higher opening at the top. Using Eq. (4) C d was computed for each data set and graphs drawn in Fig. 6-8 again show different curves for each gate opening. The best fit equations for discharge coefficient obtained from these graphs could not be converted into single generalized equation due much scatter in coefficient and exponents. In order to obtain a simple generalized equation for discharge coefficient eq. (4) was written in terms of dimensionless discharge and dimensionless depth in the following manner: Dividing both sides of (4) by and rearranging the terms It can be written as where ( ) (5) and The data were converted in the form of dimensionless discharge and dimensionless depth and graphs were drawn between Q n and Y n as shown in Figs. 9 -. It is clear from these figures that the data points represent a best fit trend with large RMS value of.99. Following equation were obtained for skew angle π/4, π/3 and 5π/2 respectively. (7) (8) (9) Above three equations can be written in a generalized form as: () where and θ is in radians. The values of exponent m in eqs. (7) - (9) are very close to.6. Thus assuming a value of.6 for m will not add significant error. Therefore, generalized equation for discharge through skew sluice gate can be expressed as: ( ) () Comparing (6) and () generalized equation for discharge coefficient of skew sluice gate in free flow condition can be written as: ( ) (2) A. Accuracy of generalized equation For the data set of each skew angle, dimensionless discharge values were computed using (). These computed values were plotted against the observed values as shown in Fig. 2. It is evident from this figure that most of the data points lie within a tolerance limit of ±5%. 46 (6)

B. Efficiency of skew sluice gate In order to examine the efficiency of skew sluice gate, the ratio of discharges through a skew sluice gate and a normal sluice gate Q /Q normal fitted in the same channel and operating under the same hydraulic conditions were computed and plotted against y/a as shown in Fig. 3. A perusal of this figure indicate that the ratio Q /Q normal remains almost constant with y/a and there is gain of 4%, 2% and % respectively for skew angles of π/4, π/3 and 5π/2. C. Reduction in afflux Afflux is defined as the maximum increase in water level at the upstream due to the presence of a hydraulic structure in a channel. Reduction in afflux can be written as Δy = y - y normal where y and y normal are the depths at the upstream of a skew sluice gate and normal sluice gate respectively when both are having the same gate opening and passing the same discharge. Percentage reduction in afflux can be written as: % Δy = For a gate opening of 5cm, values of % Δy were computed for different values of discharge for various skew sluice gates and a diagram was prepared between Q and % Δy as shown in Fig. 4. It is clear from Fig. 4 that afflux reduction is maximum in case of least skew angle. At a discharge of.5 m 3 /s, percentage reduction in afflux is 43%, 26% and 8% respectively for 45, 6 and 75 skew sluice gate. V. CONCLUSIONS A simple generalized equation for discharge coefficient for skew sluice gate in free flow condition has been proposed that can be used to find C d for any value of θ in the specified range of parameters. Using this equation discharge through skew sluice gate can be obtained within an accuracy of ±5%. Larger flow area below skew sluice gate is available for the same upstream depth relative to conventional normal sluice gate and this reduces the afflux on the upstream. Thus the requirement of free board in the channel gets reduced. REFERENCES [] Belaud G., Cassan, L., and Baume, J. P. 29. "Calculation of contraction coefficient under sluice gates and application to discharge measurement,". ASCE J of Hydraul. Eng., 35(2).86-9. [2] Clemens A. J., Strelkoff, T. S., and Replgle, J. A. 23. Calibration of submerged radial gates. ASCE J of Hydraul. Eng. 29(9). 68-687. [3]. Ferro, V. 2. Simultaneous flow over and under a gate. ASCE J of Irrig. and Drain Eng. 26(3). 9-93. [4]. Ghodsian, M. 23. Flow through side sluice gates, ASCE J of Irrig. and Drain Eng. 29(6). 458-463. [5]. Henry, H. R. 95. Discussion of Diffusion of submerged jets, Trans. Proc. ASCE. Vol. 5. 687-697. [6] Mansoor, T. 999. Study of skew weirs and sluice gates. Ph. D. Thesis. Univ. of Roorkee. Roorkee. India (Presently IIT. Roorkee. [7]. Panda, S. 98.Characteristics of side sluice flow. M. E. Thesis. Univ. of Roorkee. Roorkee. India (Presently IIT. Roorkee) [8]. Rajaratnam, N. and Subramanya, K. 967. Flow equation for the sluice gate. ASCE J. of Irrig. and Drain. Eng. 93(4). 67-86. [9] Rajaratnam, N., Free flow immediately below sluice gates. 977. ASCE J. Hydraul Eng. 3(4). 345-35. []. Spulveda, C.,Gomez, M. and Rodellar. (29).J. Benchmark of discharge calibration methods for submerged sluice gates. ASCE J of Irrig. and Drain Eng., 35(5). 676-682. [] Swamee, P. K. 992. Sluice gate discharge equations. ASCE J of Irrig. and Drain Eng., 8(). 56-6. [2] Swamee, P. K., Pathak, S. K. and Ali, M. S. (993). Analysis of rectangular side sluice gate. ASCE J of Irrig. and Drain Eng. 9(6). 26-35. [3] Swamee, P. K., Pathak, S. K. Mansoor, T., and Ojha. C. S. P. 2. Discharge Characteristics of skew sluice gates. ASCE J of Irrig. and Drain Eng. 26(5). 328-334. 47

Q(cumec) Q(cumecs) Notations The following symbols are used in this paper: a = sluice gate opening height (L); A= coefficient; B = channel width (L); Cd = discharge coefficient (nondimensional); g = gravitational acceleration (LT -2 ); L=length of skew slice gate(l); m=exponent; Q = discharge (L 3 T -2 ); Q normal = discharge through normal sluice gate (L 3 T -2 ); Q n = dimensionless discharge (L 3 T -2 ); R = Reynolds Number; W= Weber Number; y = depth of flow (L); Δy = reduction in afflux (L); Y n = dimensionless depth of flow (L); θ = sluice gate angle (nondimensional). µ= dynamic viscosity of water ρ= mass density of water.7.6.5.4.3.2. a=6cm..2.3.4.5.6.7 y(m) Fig. 3 Variation of Q verses y for θ = 45.6.5.4.3.2. a=3cm..2.3.4.5.6 y(m) Fig. 4 Variation of Q verses y for θ = 6 48

Cd Cd Q(cumec).5.4.3.2. a=3cm..2.3.4.5.6.7 Y(m) Fig. 5 Variation of Q verses y for θ = 75.9.8.7.6.5 a=6cm.4 2 3 4 5 6 7 y/a Fig. 6 Variation of C d vs y/a for θ = 45.9.8.7.6.5.4 2 3 4 5 6 y/a a=3cm Fig. 7 Variation of C d vs y/a for θ = 6 49

Qn Qn Cd.7.65.6.55 a=3cm.5.45 2 3 4 5 6 7 y/a Fig. 8 Variation of C d vs y/a for θ = 75 4 3 2 5 5 2 25 3 Yn Fig. 9 Variation of Q n vs y n for θ = 45 4 3 2 5 5 2 25 3 Yn Fig. Variation of Q n vs y n for θ = 6 5

Q/Qnormal Qn 4 3 2 5 5 2 25 3 Yn Fig. Variation of Q n vs y n for θ = 75 4 3.5 3 2.5 Qnc 2.5.5.5.5 2 2.5 3 3.5 4 Qno Fig 2 Comparison of computed and observed dimensionless discharges.5.4.3 45.2. 6 75.9.8 2 4 6 8 2 4 y/a Fig 3 Comparison of Q/Q normal with y/a for 5

% afflux reduction 5 4 3 2 75 6 45.2.3.4.5.6 Q (m 3 /s) Fig 4 Variation of % afflux reduction with discharge 52