Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Similar documents
technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

16 Input AC Block I/O Module

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

32 Input AC Block I/O Module

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Installation Instructions: ICON Anti-Condensate Controller

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

Secured Series Front End Reader Installation Instructions Proximity Reader (ProxPro, ProxPro w/keypad, MiniPro, Thinline II)

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Thermal-Magnetic Circuit Breaker 2210-S2..

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

Thermal-Magnetic Circuit Breaker 2210-S2..

Minute Impulse Clock Controller I01DN

Impedance relay and protection assemblies

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Installation guide 862 MIT / MIR

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum

ISSP User Guide CY3207ISSP. Revision C

3 Channel Constant Current DMX LED Driver

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

E2T0 DVP

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV

Thermal-Magnetic Circuit Breaker 2210-S2..

FL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

CHV Series Vector Control Inverter Options. Operating Instructions for Tension Control Card

Operating Instructions for Digital Manometer. Model: MAN-SD

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

BERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90

American Zettler AZ742 RELAY Datasheet

HiPace 300 with TC 110, DN 100 CF-F

5730A High Performance Multifunction Calibrator. Extended specifications

Pressure Display Controller

LED light engines LED compact. Module DLE G4 ADV Modules DLE

DC/DC regulator Input V Output up to 16 A

OP-02 / OP-03 / OP-04

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

24 volts (0.25 amps current-limited)

LED modules LED linear / area

Qualification Test Report

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700

HARTING D-Sub Selection Guide

MULTI-OUTPUT PROGRAMMABLE CONTROLLERS MODELS UMX-4 & UMX-8

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

HiPace 300 with TC 400, DN 100 CF-F

Analogue Meters CQ2x07 series

Product manual. Mylos KNX Shutter actuator 2CSY1104C/S

CS Series. Capacitance Type. Type. Proximity Sensor. Features

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

PCAN-MicroMod Evaluation Kit. Test and Development Environment for the PCAN-MicroMod. User Manual

Coating K = TFE wear resist, dry lubricant Kerkote X = Special coating, (Example: Kerkote with grease)

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

High Voltage Capacitors Designed to Avoid Catastrophic Failure Modes

Non-Contact Safety Systems CMS

Tuneable White DMX LED Driver

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

User Manual VX4750 Function Generator Module

MODBUS Protocol for CS141 network card families

Single point load cells

Experiment # 5 5. Coupled Water Tanks

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

General Purpose Relays Types K, R, N, and C

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

PTS Volt DC surface mount resettable PTC devices. Technical Data Applications. Agency information.

Thermal-Magnetic Circuit Breaker 2210-T2...

NTC Disc Thermistors ND 03/06/09 NE 03/06/09 NV 06/09 APPLICATIONS TECHNOLOGY PERFORMANCE CHARACTERISTICS OPTIONS STANDARDIZATION

LED light engines LED linear / area. Module QLE G3+ ADV Modules QLE ADVANCED

POINTS OF CAUTION BEFORE USE...

LED light engines LED linear / area

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

Number of poles 1-pole 2-pole Minimum Enclosure Contact G2R-1A-E G2R-1-E

Installation Operation Commissioning Maintenance

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

UL 1077 DIN Rail Supplementary Protectors

Transcription:

Remote Display Unit Installers Handbook Copyright 2001 AirSense Technology Ltd AirSense, ClassiFire, FastLearn PipeCAD, SenseNET, Stratos-HSSD and Stratos-Quadra are trademarks. HSSD is a Registered Trademark. Page 1

DESCRIPTION...3 CONSTRUCTION...3 INSTALLATION...3 REMOTE DISPLAY UNIT (RDU) - MAIN BOARD...4 REMOTE DISPLAY UNIT - RELAY BOARD...4 Using an RDU to show common detector status...4 CABLING...5 Connections...5 POWER SUPPLIES...5 APPENDIX A - ADDRESS TABLE...6 APPENDIX B - SPECIFICATION...7 RDU board...7 Relay card...7 Isolation and Product Safety Strategy - IEC 950...7 Electrical Interfaces...7 APPENDIX C - TROUBLESHOOTING...8 Page 2

Description The Stratos SenseNet Remote Display Unit (RDU) is designed for installation in an industry standard 19 rack enclosure. The unit will mimic the display of a Stratos detector connected to it on the SenseNET bus which is an RS485 data highway. A bank of switches selects the detector whose display is to be repeated. The unit is powered from a 24V DC nominal power supply. Power is distributed internally from an isolated converter. Construction The unit consists of a metal front panel plate covered with a self-adhesive graphics overlay and a main PCB that has LEDs mounted through holes in the front panel. The main PCB has terminals for the power supply input and connection to the RS485 data highway. An additional PCB provides volt-free relay contacts. These relays mimic the action of the signal relays within a detector, or the input states of a contact monitor. This additional relay board is mounted on the main board using stand-offs. Installation The RDU should be mounted in a 19 rack enclosure. RS485 wiring should be made using screened twisted pair cable. The cable screens should be connected locally and not to power supply 0V or to mains earth. The RS485 connections form part of an Airsense Technology Ltd SenseNET Bus. All other devices on this bus must have an isolated RS485 port. The unit contains static sensitive devices. Precautions must be taken during installation. Page 3

Remote Display Unit (RDU) - main board The address switch on the RDU should be set to the same address as the Stratos- HSSD or Stratos-Quadra whose display is to be repeated. Because the RDU only monitors, multiple RDU's can be set up to display the status of one detector. If no bus master or PC is to be used on the system then set switch 8 on to get the RDU to poll the detector. If multiple RDU's are used only set one RDU to poll. The RDU requires a 24 VDC power supply and is designed to be fitted into a 3u 19- inch rack frame. Eight RDU's will fit across a single 3u high frame. Remote Display Unit - relay board The optional relay board provides separate relay outputs for all the alarm levels of the Stratos-HSSD detector driving a particular RDU. Once the relay board is connected to the RDU (which must be powered off first) operation is completely automatic. Relay contacts are provided for each alarm level plus a normally energised common fault relay. Using an RDU to show common detector status Setting an RDU to address 0 will configure it to display the common alarm and fault status for all detectors. No bargraph indication will be shown when the RDU is set to the common address. If a relay board is fitted to an RDU set to address 0 then the relays will indicate common alarm and fault relays for all detectors. Note: This signal is sent from the command module and is only available when a hardware command module is being used in the system. Page 4

Cabling The SenseNET data cable should be 120Ω screened twisted pair such as Belden 9841 24 AWG. The RDU, unlike the Stratos-HSSD 2 detector, has no repeater built in so the maximum length of cable that can be connected to a RDU 1.2 is kilometres. An optional repeater unit is available if a longer cable run then 1.2 kilometres is unavoidable. Connections 0V Power supply 0 Volts. This must NOT be connected to data SCN. +24V Power supply 24 Volts input. SCN Data cable screen. A Data loop A circuit. B Data loop B circuit. Power supplies The power requirement for the RDU is 40mA max at 24 Volts ± 10%. Failure of the power supply to the RDU will cause the fault relay contact to open (if the optional relay card is fitted). Page 5

Appendix A - Address table Address 1 2 3 4 5 6 7 8 1 1 0 0 0 0 0 0 0 2 0 1 0 0 0 0 0 0 3 1 1 0 0 0 0 0 0 4 0 0 1 0 0 0 0 0 5 1 0 1 0 0 0 0 0 6 0 1 1 0 0 0 0 0 7 1 1 1 0 0 0 0 0 8 0 0 0 1 0 0 0 0 9 1 0 0 1 0 0 0 0 10 0 1 0 1 0 0 0 0 11 1 1 0 1 0 0 0 0 12 0 0 1 1 0 0 0 0 13 1 0 1 1 0 0 0 0 14 0 1 1 1 0 0 0 0 15 1 1 1 1 0 0 0 0 16 0 0 0 0 1 0 0 0 17 1 0 0 0 1 0 0 0 18 0 1 0 0 1 0 0 0 19 1 1 0 0 1 0 0 0 20 0 0 1 0 1 0 0 0 21 1 0 1 0 1 0 0 0 22 0 1 1 0 1 0 0 0 23 1 1 1 0 1 0 0 0 24 0 0 0 1 1 0 0 0 25 1 0 0 1 1 0 0 0 26 0 1 0 1 1 0 0 0 27 1 1 0 1 1 0 0 0 28 0 0 1 1 1 0 0 0 29 1 0 1 1 1 0 0 0 30 0 1 1 1 1 0 0 0 31 1 1 1 1 1 0 0 0 32 0 0 0 0 0 1 0 0 33 1 0 0 0 0 1 0 0 34 0 1 0 0 0 1 0 0 35 1 1 0 0 0 1 0 0 36 0 0 1 0 0 1 0 0 37 1 0 1 0 0 1 0 0 38 0 1 1 0 0 1 0 0 39 1 1 1 0 0 1 0 0 40 0 0 0 1 0 1 0 0 41 1 0 0 1 0 1 0 0 42 0 1 0 1 0 1 0 0 43 1 1 0 1 0 1 0 0 44 0 0 1 1 0 1 0 0 45 1 0 1 1 0 1 0 0 46 0 1 1 1 0 1 0 0 47 1 1 1 1 0 1 0 0 48 0 0 0 0 1 1 0 0 49 1 0 0 0 1 1 0 0 50 0 1 0 0 1 1 0 0 51 1 1 0 0 1 1 0 0 52 0 0 1 0 1 1 0 0 53 1 0 1 0 1 1 0 0 54 0 1 1 0 1 1 0 0 55 1 1 1 0 1 1 0 0 56 0 0 0 1 1 1 0 0 57 1 0 0 1 1 1 0 0 58 0 1 0 1 1 1 0 0 59 1 1 0 1 1 1 0 0 60 0 0 1 1 1 1 0 0 61 1 0 1 1 1 1 0 0 62 0 1 1 1 1 1 0 0 63 1 1 1 1 1 1 0 0 64 0 0 0 0 0 0 1 0 65 1 0 0 0 0 0 1 0 66 0 1 0 0 0 0 1 0 67 1 1 0 0 0 0 1 0 68 0 0 1 0 0 0 1 0 69 1 0 1 0 0 0 1 0 70 0 1 1 0 0 0 1 0 71 1 1 1 0 0 0 1 0 72 0 0 0 1 0 0 1 0 73 1 0 0 1 0 0 1 0 74 0 1 0 1 0 0 1 0 75 1 1 0 1 0 0 1 0 76 0 0 1 1 0 0 1 0 77 1 0 1 1 0 0 1 0 78 0 1 1 1 0 0 1 0 79 1 1 1 1 0 0 1 0 80 0 0 0 0 1 0 1 0 81 1 0 0 0 1 0 1 0 82 0 1 0 0 1 0 1 0 83 1 1 0 0 1 0 1 0 84 0 0 1 0 1 0 1 0 85 1 0 1 0 1 0 1 0 86 0 1 1 0 1 0 1 0 87 1 1 1 0 1 0 1 0 88 0 0 0 1 1 0 1 0 89 1 0 0 1 1 0 1 0 90 0 1 0 1 1 0 1 0 91 1 1 0 1 1 0 1 0 92 0 0 1 1 1 0 1 0 93 1 0 1 1 1 0 1 0 94 0 1 1 1 1 0 1 0 95 1 1 1 1 1 0 1 0 96 0 0 0 0 0 1 1 0 97 1 0 0 0 0 1 1 0 98 0 1 0 0 0 1 1 0 99 1 1 0 0 0 1 1 0 100 0 0 1 0 0 1 1 0 101 1 0 1 0 0 1 1 0 102 0 1 1 0 0 1 1 0 103 1 1 1 0 0 1 1 0 104 0 0 0 1 0 1 1 0 105 1 0 0 1 0 1 1 0 106 0 1 0 1 0 1 1 0 107 1 1 0 1 0 1 1 0 108 0 0 1 1 0 1 1 0 109 1 0 1 1 0 1 1 0 110 0 1 1 1 0 1 1 0 111 1 1 1 1 0 1 1 0 112 0 0 0 0 1 1 1 0 113 1 0 0 0 1 1 1 0 114 0 1 0 0 1 1 1 0 115 1 1 0 0 1 1 1 0 116 0 0 1 0 1 1 1 0 117 1 0 1 0 1 1 1 0 118 0 1 1 0 1 1 1 0 119 1 1 1 0 1 1 1 0 120 0 0 0 1 1 1 1 0 121 1 0 0 1 1 1 1 0 122 0 1 0 1 1 1 1 0 123 1 1 0 1 1 1 1 0 124 0 0 1 1 1 1 1 0 125 1 0 1 1 1 1 1 0 126 0 1 1 1 1 1 1 0 127 1 1 1 1 1 1 1 0 Page 6

Appendix B - Specification RDU board Nominal operating Voltage: 24 Volts ±10% Maximum input Voltage range: 18 to 30 Volts DC Maximum operating current: Operating temperature range: Storage temperature range: Operating humidity range: 40 ma -10 to +60 0 C -25 to +85 0 C 0 to 90 % non-condensing Relay card Maximum switching Voltage: Maximum switching current: Minimum life expectancy: Maximum contact resistance: 200 Volts DC 0.5 A 1 x 10 8 activations 100 milliohms Isolation and Product Safety Strategy - IEC 950 All power will be supplied via a purpose made supply built to EN54 or equivalent. This supply will incorporate isolation sufficient that its outputs are SELV. System interconnections will therefore be SELV whether floating or not. Relays will be fully isolated as capable of connection to any external circuit. Bus interfaces will not be isolated and it will be the responsibility of the installer to provide sufficient isolation in connected equipment. Enclosures will be earthed either through its mounting or by use of shielded supply cabling. Electrical Interfaces Terminals. Type: Screw terminals M3 Maximum wire size: 2.5mm 2 Page 7

Appendix C - Troubleshooting symptom RDU is dead (no lights and fault relay open) RDU shows fault but the detector shows OK probable cause Input Voltage missing or too low The RDU is not receiving data. Check cabling and set the RDU to poll the detector if necessary. Check the address switch. Page 8