Technical Note Series

Similar documents
Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Installation guide 862 MIT / MIR

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Sitting height... 6 Back tilt and back height... 6 Armrest... 7 Brakes... 7 Charging VELA Tango 300E... 7

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Decade Capacitance System

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Presco AG. Standard Air Capacitor 10 nf / 2 kv. Type CL-0N10-K201. User's manual

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800

Instruction Manual SEFRAM Thermal Camera

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

Dielectric Analysis of Solid Insulations

473-SHX Dew Point Mirror

473 Dew Point Hygrometer

LITE-ON TECHNOLOGY CORPORATION

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

PHOENIX CONTACT - 04/2016. Features

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

symphony Multisensor Probes

user's manual nx frequency converters resolver option board opt-bc

WeatherHub2 Quick Start Guide

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L

16 Input AC Block I/O Module

What You Need to Get Started INSTALLATION GUIDE

T1 and E1 Feature Cards

Resistivity vs. Temperature of a Superconductor WARNING

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

Field Pro Operation and Installation Manual

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Chemistry MultiMeasure Sensor PS-2170

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

User Manual VX4750 Function Generator Module

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

32 Input AC Block I/O Module

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

1. Electrostatic Lab [1]

22X Builder s Level Model No Instruction Manual

Assembly and Operation Manual. April 2016

Human Arm. 1 Purpose. 2 Theory. 2.1 Equation of Motion for a Rotating Rigid Body

Surface Mount UV LED. NUVA33 Series PART NUMBERING SYSTEM. WAVELENGTH CODES Code Nominal Wavelength

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

Installation Manual. Installation manual for PerfectEnergy Solar Modules. Content

O P E R A T I N G M A N U A L

N) manual. Biomaster Operating manual

Electric amplifiers. RE 30044/02.12 Replaces: Type VT-VRPA X/V0/RTS-2STV. Component series 2X 1/8

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

EOSMS Guidelines Date: 01/16/2014 Page 1 of 5

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Dielectric Analysis of Insulation Liquids

Laboratory 3 Measuring Capacitor Discharge with the MicroBLIP

Acceleration/Velocity/Displacement VIBRATION METER

EE 1/3.5х14 U EE 1/3.5х14 U

INSTALLATION INSTRUCTIONS ATV PLOW ACCESSORY Plow Mounting Kit:Warn PN Application:2002 and newer+ Suzuki Eiger 400

Lab 1f Boiling Heat Transfer Paradox

u s e r m a n u a l w w w. v e l a. E U

473 Dew Point Hygrometer

Training Guide. Coastal Environmental Systems, Inc.

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

INSTALLATION INSTRUCTIONS PLOW MOUNT KIT Part Number: Application: Honda Foreman 500

22X Builder s Transit Level Model No Instruction Manual

The Vortex Razor HD Gen II-E 1 6x24 Riflescope

SOTM LAB: P16 OHM S LAW I. TEACHER NOTES & GUIDELINES TITLE OF LAB: Ohm s Law DEVELOPERS OF LAB:

VELA Tango 100. VELA Tango 100A. VELA Tango 200 GAS

RAY S ESD PREVENTION SECRETS TRAINING CERTIFICATION TEST (DVD-75C) v.1

Rain Collector (# 7852 & 7852M)

Installation Instructions: ICON Anti-Condensate Controller

ph Probe ReallyEasyData com

CTC 155 / 350 / 660 Dry-block calibrator

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

Reference Only Spec. No. JEFL243B 0003F-01 P 1/ 6

symphony Reference Electrodes

CHARACTER TYPE LCD MODULE PVC160101PTN03 PRODUCT SPECIFICATIONS

LUDLUM MODEL NEUTRON DETECTOR. December 2017

Installation and Operation Manual. AllSync Plus Wired Clocks

5484BN/R7DC-AHJB/XR/MS(ELA)

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Shampoo Woo, by Cindy Anderson and Matthew Dornier. Chemistry. Materials

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

5mm Silicon PIN Photodiode, T-1 3/4 PD333-3B/H0/L2

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

3mm Photodiode PD204-6B

INSTALLATION INSTRUCTIONS ProVantage Plow Pulley Part Number: 84526

Rapid Averaging Probe (RAP)

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 400

INE-DDB-303A Portable Conductivity Meter Instruction Manual

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA MODELS: 450S AND 450ES

Qualification Test Report. Modular Plugs, Unshielded and Shielded

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

Transcription:

Technical Note Series INCLINOTRAC (T7650) & DUAL-INCLINOTRAC (T7655) S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 2

IMPORTANT OPERATION INFORMATION Type BF Equipment Internally powered equipment Continuous operation WARNING Explosion Hazard; Do not use in the presence of a flammable anesthetic mixture with air, or with Oxygen or Nitrous Oxide. Not to be immersed in water. CAUTION Connection of customer supplied circuits to Thought Technology sensor products has the potential to damage the sensor. Such damage is not covered by warranty. ATTENTION MAINTENANCE AND CALIBRATION For research only. Not for use in diagnostic procedures. To prevent voiding warranty by breaking connector pins, carefully align white guiding dot on sensor plug with slot on sensor input. Wipe with a clean cloth Factory testing and calibration ensure equipment accuracy and frequency response. No preventative inspections required; STORAGE Temperature -23C +60C Humidity (non-condensing) 10% 90% Atmospheric pressure 700 1060 KPa Temperature -23C +60C TRANSPORTATION Humidity (non-condensing) 10% 90% Atmospheric pressure 700 1060 KPa S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 3

PRODUCT OVERVIEW InclinoTrac is a single inclinometer that measures the inclination angle relative to the ground. Dual-InclinoTrac is a dual inclinometer that measures relative angle (between back and head, for instance). InclinoTrac and Dual-InclinoTrac use solid-state micro-machined sensors and microprocessor technology to provide rapid settling and high resolution (0.1 ) and accuracy (1.0 ). They are the ideal choice for Range of Motion (ROM) assessment. They can be used in various ways: simply put on the examinee, or attached with straps on either the examinee or the workout machine. OPERATING PRINCIPLES This section gives recommendations for ensuring accuracy and consistency of measurement. Being familiar with the tools The single inclinometer is called InclinoTrac. The dual inclinometer is called Dual-InclinoTrac (see picture below), and consists of two InclinoTracs connected together. Zero Secondary Primary Output Dual-InclinoTrac The plug at one end is used to connect the inclinometer to the DAQ. The Zero button at other end is used to mark the neutral zero. Two devices are connected together by a cable. The connector is on the side of the device (see picture above). The inclinometer connected to the DAQ is then called the primary. The other one is called the secondary. S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 4

The dual inclinometer outputs the angle between the primary and secondary devices. The primary and secondary must be oriented so that the InclinoTrac labels face the same way. Either zero button can be used to mark the neutral position. Correctly oriented Incorrectly oriented Calibrating the Inclinometer (zeroing) Make sure your inclinometer is properly calibrated. The inclinometer must be recalibrated if you press the zero button and the screen does not display the value "0" (zero). Straps or No Straps? Straps were designed to be used for dynamic ROM assessment, ROM therapy and for the static ROM assessment of the extremities. Manually holding the inclinometers is strongly recommended in the case of static spine assessment. However, straps may be used to assist you in holding the inclinometers (on the head, for instance) to avoid having them slip, or when you assist the examinee in a passive motion. If you manually handle the inclinometers, make sure you apply a constant pressure throughout the range of motion. If you use a strap to attach the inclinometer, make sure that the strap is secured and cannot move against the body part during the motion. Also check that the inclinometer is firmly fixed to the strap. To do this, press it against the strap and twist it sideways two or three times, so that the hooks and loops are thoroughly enmeshed. Twist the inclinometer sideways two or three times while holding it firmly against the strap This will ensure the inclinometer keeps the same orientation against the body part in motion and does not slip from its original position. Proper orientation The guide suggests positions of the inclinometers for each range of motion. You may find that different positions are more convenient for you or the examinee. S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 5

However, you have to pay attention to the orientation of the inclinometers. The first motion of the two (for instance, flexion in flexion/extension ) must give a positive angle and the second motion ( extension ) a negative angle. The system will rectify the angles in the report according to this rule. Correct orientation of the inclinometers Always keep the side with the inclinometer plug within 45 of the vertical plane and parallel to the plane of motion. Incorrect orientations of the inclinometers S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 6

SENSOR PLACEMENT This section proposes typical sensor placements with AMA normative data (Andersson Gunnar B. J. & Cocchiarella Linda. (2007). Guides to the Evaluation of Permanent Impairment, 6 th Edition. American Medical Association). SROM Cervical Spine Flexion/Extension Neutral Position Flexion Extension Dual-Inclinometer Examinee Position: Seated on a chair or standing upright Inclinometer Position: Primary back on T1 parallel to the spine; secondary back on the top of the head, perpendicular to the shoulders. Normal ROM: Flexion 50 Validity of the trials: Extension 60 Within 5 or 10% of another Left/Right Lateral Flexion Neutral Position Left Lateral Flexion Right Lateral Flexion Dual-Inclinometer Examinee Position: Seated on a chair or standing upright Inclinometer Position: Primary side on T1 parallel to the spine; secondary on the head Normal ROM: Left Lateral Flexion 45 Validity of the trials: Right Lateral Flexion 45 Within 5 or 10% of another Left/Right Rotation S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 7

Neutral Position Left Rotation Right Rotation Dual-Inclinometer Examinee Position: Knees and hands on the floor, head horizontal, or in supine position Inclinometer Position: Primary side on T1 perpendicular to the spine; secondary on the head Normal ROM: Left Rotation 80 Validity of the trials: Right Rotation 80 Within 5 or 10% of another SROM Thoracic Spine Flexion/Extension Neutral Position Flexion Extension Dual-Inclinometer Examinee Position: Standing upright Inclinometer Position: Primary on T12 and secondary on T1; both parallel to the spine. Normal ROM: Flexion 60 Validity of the trials: Extension 10 Within 5 or 10% of another S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 8

Left/Right Rotation Neutral Position Left Rotation Right Rotation Dual-Inclinometer Examinee Position: Standing position, bending forward Inclinometer Position: Primary on T12 and secondary on T1; both perpendicular to the spine. Normal ROM: Left Rotation 30 Validity of the trials: Right Rotation 30 Within 5 or 10% of another SROM Lumbar Spine Flexion/Extension Neutral Position Flexion Extension Dual-Inclinometer Examinee Position: Standing upright Inclinometer Position: Primary on S1 and S2, secondary on T12; both parallel to the spine. Normal ROM: Flexion 50 Validity of the trials: Extension 20 Within 5 or 10% of another S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 9

Left/Right Lateral Flexion Neutral Position Left Lateral Flexion Right Lateral Flexion Dual-Inclinometer Examinee Position: Standing upright Inclinometer Position: Side of primary on S1 and S2, side of secondary on T12; both parallel to the spine, front facing left. Normal ROM: Left Lateral Flexion 30 Validity of the trials: Right Lateral Flexion 30 Within 5 or 10% of another SROM Shoulder Flexion/Extension Neutral Position Flexion Extension Single-Inclinometer with strap Examinee Position: Seated, uninvolved shoulder flexed 90. Normal ROM: Flexion 180 Validity of the trials: Extension 50 Within 5 or 10% of another S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 10

Abduction/Adduction in 30 Flexion Neutral Position Abduction Adduction Single-Inclinometer with strap Examinee Position: Seated, uninvolved shoulder abducted 90. For adduction: involved shoulder flexed 30. Normal ROM: Abduction 160 Validity of the trials: Adduction 30 Within 5 or 10% of another External/Internal Rotation Neutral Position External Rotation Internal Rotation Single-Inclinometer with strap Examinee Position: Seated, shoulder abducted 90 and elbow flexed 90. Normal ROM: External Rotation 90 Validity of the trials: Internal Rotation 90 Within 5 or 10% of another S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 11

SROM Elbow Flexion/Extension Neutral Position Flexion Examinee Position: Single-Inclinometer with strap Seated, or supine position with elbow stabilized on examining table. Normal ROM: Flexion 135 Validity of the trials: Extension 0 Within 5 or 10% of another SROM Forearm Supination/Pronation Neutral Position Supination Pronation Single-Inclinometer Examinee Position: Seated, elbow flexed 90, uninvolved side abducted 90. Normal ROM: Supination 90 Validity of the trials: Pronation 90 Within 5 or 10% of another S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 12

SROM Wrist Flexion/Extension Neutral Position Extension Examinee Position: Single-Inclinometer Seated, or with pronated forearm stabilized on examining table. Normal ROM: Flexion 50 Validity of the trials: Extension 60 Within 5 or 10% of another Radial/Ulnar Deviation Neutral Position Radial Deviation Ulnar Deviation Single-Inclinometer Examinee Position: Seated, or with forearm stabilized on examining table. Normal ROM: Radial Deviation 20 Validity of the trials: Ulnar Deviation 30 Within 5 or 10% of another S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 13

SROM Hip Flexion/Extension Neutral Position Flexion Extension Examinee Position: Single-Inclinometer with strap For flexion: in supine position with pelvis and lower extremities stabilized on the table For extension: trunk and pelvis in prone position on the table, uninvolved hip in 90 flexion. Normal ROM: Flexion 100 Validity of the trials: Extension 30 Within 5 or 10% of another Abduction/Adduction in 30 Flexion Neutral Position Abduction Adduction Single-Inclinometer with strap Examinee Position: Side-lying on the table. Normal ROM: Abduction 45 Validity of the trials: Adduction 30 Within 5 or 10% of another S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 14

External/Internal Rotation Neutral Position External Rotation Internal Rotation Single-Inclinometer with strap Examinee Position: Supine Normal ROM: External Rotation 50 Validity of the trials: Internal Rotation 40 Within 5 or 10% of another SROM Knee Flexion/Hyperextension Neutral Position Flexion Examinee Position: Single-Inclinometer with strap Prone, with foot vertical in rest position and knee beyond the end of the table. Normal ROM: Flexion 150 Validity of the trials: Hyperextension 0 Within 5 or 10% of another S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 15

SROM Ankle Flexion/Extension Neutral Position Flexion Extension Examinee Position: Single-Inclinometer Prone, with foot vertical in rest position (beyond the end of the table) Normal ROM: Flexion 40 Validity of the trials: Extension 20 Within 5 or 10% of another TECHNICAL SPECIFICATIONS Dimensions 32mm x 18mm x 71mm Weight 26g Range ± 180 Accuracy (operated in vertically-oriented plane) 1.0 (standalone mode) 2.0 (dual mode, angle difference) Output gain 4.44mV / degree inclination Output voltage span 2.200 ± 0.8V Power supply 7.26V Current consumption, maximum 9.5 ma (standalone mode) 19.0 ma (dual mode) Link cable RJ-11, 2 pairs, reversed (this is not a standard telephone cable) INTERFACING WITH 3 RD PARTY DATA ACQUISITION SYSTEM Recommended Connectivity for Electrical Safety Thought Technology recommends the use of TT Sensor Isolator SE9405AM when interfacing client connected sensor(s) to line powered equipment(s) or devices. The TT Sensor Isolator SE9405AM is an interface device providing medical grade electrical isolation between the client connected sensors and the acquisition system. It provides the equivalent of Two Means of Client Protection under IEC 60601-1, and supplies battery power to the sensors. Using this device ensures Thought Technology sensors are safely interfaced to the analog inputs of line-powered systems such as computers with DAQ cards. S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 16

Note that this device isolates only between sensors and the DAQ interface, not between different sensor channels. The TT Sensor Isolator can interface up to 4 sensors to a DAQ card. TT Sensor Isolator can be connected to the DAQ card in two ways: via two stereo jacks, or via a DB-15 connector; a BNC interface cable (SA9409BNC) or a pigtail cable (SA9409PGT) can be provided with the unit. Sensor 1 Sensor 2 TT Sensor Isolator DAQ Board Sensor 3 Sensor 4 For more detailed information on the Sensor Isolator 4, consult the Thought Technology Science Division website or contact the sales department or an authorized distributor. Direct Connectivity for Electrically Isolated Systems The following notes are provided for qualified users to directly interface Thought Technology sensors with external systems. To interface with a sensor, a single sensor cable may be cut in half. Both sides can then be used to make custom interfacing cables by stripping the outer insulation of each required conductor. The sensor cable contains 4 color coded conductors. The table below shows the color coding and pin connector assignment. Pin Color code Function Note 1 metal (shield) ground Signal and power ground, connection required. 2 yellow auxiliary (sensor ID) No connection required. 3 green signal Sensor output signal 4 red Supply voltage, +7.26V referenced to sensor ground. Note: sensor performance may power be sensitive to supply voltage. S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 17

Notes: 1. The nominal supply voltage for this sensor is 7.26V. The sensor can safely be used with a supply voltage of up to 9V. Recommended Specifications for DAQ Hardware Recommended resolution of 0.15mV (16-bit ADC over 10V span) or better Minimum input range: o If connected via SE9405AM Sensor Isolator, choose 0-5V (unipolar) or ±5V (bipolar) o If directly connected to DAQ, choose ±5V (bipolar). Simplified Transfer Function 225V 495 Conversion of voltage [V] to output angle in degrees deg out S TN0011-0 0 I n c l i n o T r a c / D u a l - I n c l i n o T r a c Page 18