Cadmium and lead content

Similar documents
Carbonate content. SCAN-N 32:98 Revised White, green and black liquors and burnt lime sludge

Total sulphur content

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

Test Method: CPSC-CH-E

Sodium Chloride - Analytical Standard

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

Sodium Chloride - Analytical Standard

GB Translated English of Chinese Standard: GB

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

DRAFT EAST AFRICAN STANDARD

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Total, active and effective alkali

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

METHANOL REFERENCE SPECIFICATIONS

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

Chemical Reactions: The Copper Cycle

National standard of People s Republic of China

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

SOIL ORGANIC CONTENT USING UV-VIS METHOD

Sodium Chloride - Analytical Standard

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Corn Syrup Analysis E-51-1 PHOSPHORUS

IMPCA METHANOL REFERENCE SPECIFICATIONS

Method for estimation of iodine in urine

STANDARD PROCEDURE: NWSP R2 (15) Polyacrylate Superabsorbent Powders Determination of the Particle Size Distribution by Sieve Fractionation

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

ISO INTERNATIONAL STANDARD. Water quality Determination of trace elements using atomic absorption spectrometry with graphite furnace

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

UNITED NATIONS. ENVIRONMENT PROGRAMME MEDITERRANEAN ACTION PLAN 25 May 2015 Original: English. UNEP(DEPI)/ MED WG.417/Inf.14

Determination of Orthophosphate Ion

ISO 8070 IDF 119 INTERNATIONAL STANDARD

P E R O X Y G E N S A sector group of Cefic

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

SOUTH AFRICAN NATIONAL STANDARD. Standard test methods for lead in water

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Alpha-, beta- and gamma-cellulose in pulp. 1. Scope

INTERNATIONAL OLIVE COUNCIL

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

National standard of People s Republic of China

maect PRODUCTION SOP M/1 JUNE 2007 version page: 1 Preparation of 2 liters of 10x concentrated PBS stock solution (phosphate buffered saline)

IMPCA METHANOL REFERENCE SPECIFICATIONS

Laboratory Measurements and Procedures

Oxygen Demand, Chemical

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

Determination of Orthophosphate Ion

Spectrophotometric Determination of Ferrocyanide in Effluents

PAR Method Method to 2.0 mg/l Pb TNTplus 850

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

DISCLAIMER: This method:

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Basic Digestion Principles

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Analytical Procedures for Monitoring Farmbased Anaerobic Digestion (AD) Systems: PROTOCOL III

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

INTERNATIONAL STANDARD

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

Annex 2 Formaldehyde

CRD-C Standard Test Methods for Determining the Water Content of Freshly Mixed Concrete

7-A. Inquiry INVESTIGATION. 322 MHR Unit 3 Quantities in Chemical Reactions. Skill Check. Safety Precautions

Oxygen Demand, Chemical

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography 1

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Calcimeter. Meet the difference. Manual. T E I

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

ICP-OES Application Note Number 35

/TC TC WI. Date: /TC. Secretariat: Einführendes Element Haupt-Element Ergänzendes Element

CORESTA Recommended Method No. 86

Cyanide, colorimetric, pyridine-pyrazolone

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

SOUTH AFRICAN NATIONAL STANDARD

Experiment 7A ANALYSIS OF BRASS

Identification of an Unknown Compound through Mass Correlations

Analysis of domestic sludge using the Agilent 4200 MP-AES

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Transcription:

Accepted 1997 Pulps, papers and boards Cadmium and lead content Atomic absption spectrometry - graphite furnace technique 1 Scope This SCAN-test Method specifies a method f the determination of traces of cadmium and lead in all types of pulps, papers and boards, including products containing recycled fibre, that can be wet-digested in nitric acid as specified in this Method. Two alternative wet digestion techniques are specified: digestion in an autoclave and digestion in a microwave oven. The limit of determination depends upon the amount of sample and upon the type of atomic absption spectrometer used. The lower limit of determination is nmally from 0,002 to 0,01 f cadmium and from 0,02 to 0,1 f lead, depending on the sample size and the instrument used. Note Lead present in coating and filler pigments that do not dissolve in nitric acid under the conditions specified in this Method will not be determined in a low-pressure vessel unless hydrofluic acid is used. 2 References ISO 638 Pulp Determination of dry matter content Note SCAN-test has withdrawn a number of test methods and refers instead to the cresponding ISO and/ EN Standards. 3 Definitions F the purpose of this Method, the following definitions apply: 3.1 Cadmium content The ratio of the mass of the element cadmium in the sample to the mass of the dry sample. 3.2 Lead content The ratio of the mass of the element lead in the sample to the mass of the dry sample. 4 Principle The sample is treated with nitric acid in a closed vessel at elevated temperature and pressure. The resulting solution is diluted, and the cadmium and lead contents are determined by atomic absption spectrometry using the graphite furnace technique.

Page 2 5 Reagents All reagents shall be of highest possible purity. The usual analytical grade is often not sufficiently pure. 5.0 Water, only freshly distilled deionized water, of the highest possible purity. 5.1 Concentrated nitric acid, c(hno 3 ) = 15 mol/l. Use a quality specially made f use in the determination of trace elements. 5.2 Dilute nitric acid, c(hno 3 ) = 0,15 mol/l. Dilute 10 ml of the concentrated nitric acid (5.1) to 1 litre with water (5.0). 5.3 Cadmium stock solution, c(cd) = 1,000 g/l, made by dissolving (2,744 ± 0,005) g of cadmium nitrate tetrahydrate, Cd(NO 3 ) 2. 4H 2 O per litre of nitric acid, c(hno 3 ) = 0,5 mol/l. The solution is commercially available. 5.4 Cadmium standard solution, c(cd) = 1,00 mg/l. Using a precision pipette, dilute 1,00 ml of the cadmium stock solution (5.3) to 1000 ml with diluted nitric acid (5.2) in a volumetric flask. Mix by shaking the flask. The solution has a shelf-life of several months if it is sted in a polyethylene bottle. 5.5 Lead stock solution, c(pb) = 1,000 g/l, made by dissolving (1,000 ± 0,002) g of lead in a mixture of 10 ml of concentrated nitric acid (5.1) and 10 ml of water (5.0), and diluting to 1000 ml with water. The solution is commercially available. 5.6 Lead standard solution, c(pb) = 1,00 mg/l. Using a precision pipette, dilute 1,00 ml of the lead stock solution (5.5) to 1000 ml with diluted nitric acid (5.2) in a volumetric flask. Mix by shaking the flask. The solution has a shelf-life of several months if sted in a polyethylene bottle. 5.7 Matrix modifier solutions. Several matrix modifier solutions are recommended in the literature. The three solutions given here are in common use. Matrix modifier solutions are commercially available. 5.7.1 Palladium nitrate stock solution. Dissolve 2,0 g of Pd(NO 3 ) 2 in 10 ml of concentrated nitric acid (5.1) and dilute with water (5.0) to 500 ml in a volumetric flask. 5.7.2 Ammonium dihydrogen phosphate stock solution. Dissolve 2,0 g of (NH 4 )H 2 PO 4 in water (5.0) and dilute to 100 ml. 5.7.3 Magnesium nitrate stock solution. Dissolve 0,5 g of magnesium nitrate, Mg(NO 3 ) 2, in water (5.0) and dilute to 100 ml. Note The solutions 5.7.1, 5.7.2 and 5.7.3 can be combined. 5.7.4 Matrix modifier wking solutions. Prepare matrix modifier wking solutions accding to the instructions given by the instrument supplier. 6 Apparatus 6.0 Ordinary labaty equipment. All equipment used shall be washed in nitric acid, approx. 1 mol/l, f at least 24 h and afterwards rinsed with water (5.0). 6.1 Apparatus f wet digestion, either: 6.1.1 Autoclave, with an inner vessel of PTFE (polytetrafluoethylene), volume 250 ml, provided with a lid of PTFE, and a heating block that can maintain the autoclave at a temperature of (160 ± 5) C. The block must be provided with safety arrangements that prevent it from being overheated. Note 1 The use of an oven instead of the heating block is not recommended because of the hazard involved in removing the hot autoclaves from the oven at the end of the heating period. 6.1.2 Microwave oven f labaty purposes, with programming facilities and equipped with a rotating vessel holder. The digestion vessels, made of PTFE, shall have a volume of at least 100 ml, and either low-pressure highpressure vessels may be used. Follow the safety regulations given by the oven supplier. Since the sample size influences the change of pressure and temperature during the wet digestion, the oven should preferably be equipped with temperature and pressure facilities recding. The oven shall be able to keep the temperature constant at (175 ± 5) C. Note 2 If the amount of sample in all vessels placed in the oven at the same time is similar and of the same material character, it is sufficient to check the change in temperature and pressure in only one vessel. 6.2 Atomic absption spectrometer, equipped with the graphite furnace technique and with pyrolytic coated tubes with a L'vov platfm, and with lamps f the determination of cadmium and lead. The instrument shall have background crection (15.1).

Page 3 7 Sample preparation The sampling procedure is not covered by this Method. Make sure that the test pieces taken are representative of the sample received. In der to avoid contamination, keep the sample wrapped in high-density polyethylene until required. From the sample, tear pieces about 10 10 mm in size to provide the amount required, taking approximately the same amount from each specimen. Use tools of plastics ceramics. Do not use a knife any other metal tool. Split pieces of pulp sheets and board sheets to reduce their thickness. Keep the sample near the balance f moisture equilibration f at least 20 min. Withdraw a sample f the determination of dry matter content in accdance with ISO 638 irrespectively of the kind of sample. 8 Wet digestion Carry out the procedure in duplicate. Run also a blank, see Clause 9. Note 1 Hydrofluic acid can be used f a total digestion of the cadmium and lead content present in the sample. The use of hydrofluic acid in labaty routines is not desirable since the acid is hazardous. If, however, hydrofluic acid is used, it shall be repted. 8.1 Weigh to the nearest 1 mg a sample of about 1 g, the maximum amount permissible within safety limits f the equipment used. Transfer the sample to the PTFE vessel. Add 10 ml of the concentrated nitric acid (5.1). Close the vessel with its lid and place it in the autoclave (6.1.1) in the microwave oven (6.1.2) as relevant. Warning Esters and alcohols can fm explosive compounds with nitric acid. If the sample contains considerable amounts of such compounds, digestion with nitric acid should not be undertaken. Note 2 If a microwave oven is used, the sample size has to be adjusted to the capacity of the digestion vessel. If the volume of the low-pressure digestion vessel is 120 ml, the maximum sample weight is 0,3 g. If me sample is taken, the safety disc will rupture with consequent loss of sample solution. 8.2.1 If an autoclave is used: Close the autoclave as instructed by the manufacturer and place it in the heating block (6.1.1). Heat it at a temperature of (160 ± 5) C f (16 ± 1) h. Allow the heating block and the autoclave to cool and, with caution, open the autoclave in a hood. Proceed to Subclause 8.3. Note 3 Follow the safety regulations f the equipment. 8.2.2 If a microwave oven is used: The exact power and time required may vary with the equipment used and the number of samples taken. Heat the closed digestion vessel (6.1.2), with its content, step by step, f about 45 min and hold the temperature at (175 ± 5) C f at least 5 min. It is essential that the sample is completely digested. Allow the vessel to cool and, with caution, open it in a hood. Note 4 Check the vessel and the sample after the wet digestion to ensure that no leakage has occurred. 8.3 Allow nitrous fumes to escape from the wet digestion vessel and dilute the remaining solution in a graded vessel of, f example, 25 ml. The volume should be kept as small as possible. Allow any suspended matter to settle. 9 Blank Run a blank following the instructions in Clause 8, but using no sample. Note Determination of trace elements is always sensitive to contamination. The proper cleaning of the digestion vessels is therefe essential. To ensure accurate results, rinse the vessels befe use with nitric acid in the same way as the blank is prepared. It is recommended that the absbance of the rinsing solution is measured. If the absbance exceeds 10 of the expected value f the samples, the rinsing should be repeated. 10 Preparation of calibration solutions Prepare the calibration solutions by diluting the standard solutions (5.4) and (5.6) with dilute nitric acid (5.2). The cadmium and lead contents selected f the final calibration solutions depend on the particular instrument to be used. In general, a calibration solution having a cadmium content of 5 μg/l (= 0,005 μg/ml) and a lead content of 20 μg/l (= 0,02 μg/ml) is appropriate. The acid concentration of the calibration solutions should be adjusted to that of the sample solutions by replacing part of the dilute nitric acid (5.2) with concentrated nitric acid (5.1). As an independent check of the calibration, samples of known cadmium and lead contents should be analysed.

Page 4 11 Determination The procedure f the spectrometric determination of the cadmium and lead contents of the sample solutions depends on the design of the atomic absption spectrometer and of the graphite furnace. Follow the manufacturer's instructions when operating the instrument. Note The procedure should be checked by means of standard reference materials of similar type. 14 Precision 14.1 Repeatability. One pulp sample and two paper samples were analysed six to eight times in the same labaty using each of the two methods f wet digestion. The repeatability of the cadmium content determination, measured by the coefficient of variation (CV) within a labaty, was as follows (the figures in parentheses are the number of duplicates): 12 Calculation Calculate the cadmium lead content of the iginal sample, taking into account the amount of sample taken to wet digestion, its dry matter content and the blank value: X = cfv [1] m where X is the concentration of trace metal in the sample, in milligrams per kilogram; c is the concentration of trace metal in the sample solution crected f the blank, in micrograms per litre; f is the dilution fact; V is the volume of the sample solution, in litres; m is the mass of the dry sample, in grams. Note In trace element analysis the results from replicate determinations can be inconsistent due to inherent inhomogenity of the material tested. Calculate and rept the mean trace metal content f each element in milligrams per kilogram, with two significant figures if the content exceeds 0,1 and with one significant figure f a content less than 0,1. 13 Rept The test rept shall include reference to this SCAN-test Method and the following particulars: (a) (b) (c) (d) (e) date and place of testing; identification mark of the sample tested; the wet-digestion procedure used (autoclave microwave oven); the content of each element; any departure from the procedure described in this SCAN-test Method any other circumstances that may have affected the test results. Unbleached kraft 0,06 (6) 7,6 0,07 (6) 2,9 0,04 (7) 8 0,05 (5) 33 Copy paper 0,20 (7) 32 0,15 (8) 18 The repeatability of the lead content determination, measured by the coefficient of variation (CV) within one labaty was as follows (the figures in parentheses are the number of duplicates): Unbleached kraft 0,15 (6) 3,4 0,14 (6) 4,9 0,04 (7) 27 0,07 (5) 19 Copy paper 0,71 (7) 16 0,60 (6) 6,4 14.2 Reproducibility. Seven labaties analysed five samples of pulp and paper using the autoclave method and/ the microwave oven method f wet digestion. The reproducibility of the cadmium content determination, measured by the coefficient of variation (CV) between labaties, was as follows (the figures in parentheses give the number of labaties using each method): Bl. kraft 0,002 (4) 38 0,003 (4) 104 Coated 0,03 (4) 35 0,03 (4) 23 0,04 (5) 20 0,04 (4) 25 Copy paper 0,15 (5) 48 0,15 (4) 20

Page 5 Recycled pulp 0,01 (5) 24 0,01 (5) 29 The reproducibility of the lead content determination was as follows (the figures in parentheses give the number of labaties using each method): 15 Literature 15.1 Svensk Standard SS 02 81 83, Clause 5.2. Metal content of water, sludge and sediment Determined by flameless atomic absption spectrometry Electrothermal atomization in a graphite furnace General principles and guidelines. Bl. 0,05 (4) 141 0,07 (3) 76 Coated 3,0 (4) 9 2,7 (4) 25 0,05 (5) 68 0,15 (3) 63 Copy paper 0,65 (5) 7 0,43 (5) 28 Recycled pulp 2,5 (5) 34 2,0 (5) 10 The contents of cadmium and lead in pulp and paper f some of the analysed samples are close to the detection limit. F these samples, the coefficient of variation becomes high. SCAN-test Methods are issued and recommended by KCL, PFI and STFI-Packfsk f the pulp, paper and board industries in Finland, Nway and Sweden. Distribution: Secretariat, Scandinavian Pulp, Paper and Board Testing Committee, Box 5604, SE-114 86 Stockholm, Sweden.