SP-700 Free Chlorine Analysis TMB Method

Similar documents
SILICA, Low Range SiLR

The Determination of an Equilibrium Constant

Determining the Concentration of a Solution: Beer s Law

Order of a Reaction. Using Labquest and Colorimeter. Teachers Guide

The Determination of an Equilibrium Constant

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Experiment C-10 Titration of a Strong Acid and a Strong Base

Determining the Concentration of a Solution: Beer s Law

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

SP-910 Portable Water Analyzer Procedures Manual

Chemical Equilibrium: Finding a Constant, Kc

REVIEW OF LAB TECHNIQUES

Paraquat ELISA Kit. Catalog Number KA assays Version: 17. Intended for research use only.

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

REVIEW OF LAB TECHNIQUES

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy

Instruction Manual. Waterproof Portable Colorimeter C401 / 301 / 201 / 101 / 102 / 103 / 104 / 105. Part of Thermo Fisher Scientific

PREPARATION FOR CHEMISTRY LAB: FLUORIDE IN WATER

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

PRELIMINARY ACTIVITY FOR

Chlorine, Free and Total, Low Range

Related concepts Electrolyte, electrical conductance, specific conductance, ion mobility, ion conductivity, conductometry, volumetry.

Titration of a strong acid with a strong base with Cobra4

Chlorine, Free and Total, High Range

Quaternary Ammonium Compounds

Spectrophotometry Materials

RayBio Human IDUA ELISA Kit

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Chlorine, Free and Total, High Range

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

2 (aq) [FeSCN [Fe 3JSCN] Figure 1

Instruction Manual C401/301/201/102/101. Portable Colorimeter. 99 Washington Street Melrose, MA Phone Toll Free

Method for Nitrite determination on Low-Range Samples

RayBio Human Thyroid Peroxidase ELISA Kit

MEASUREMENT: PART II

Method to 0.50 mg/l NH 3 N Powder Pillows

Experimental Procedure. Lab 406

Experiment 11 Beer s Law

Experiment 11 Beer s Law

Lab Activity H4 It s Snow Big Deal

The Determination of an Equilibrium Constant

NITROGEN, TOTAL, HR, Test N Tube

CHLORINE, TOTAL (0 to 4.00 mg/l)

Spectrophotometric Determination of pka of Phenol Red

Method to 0.50 mg/l NH 3 N Powder Pillows

DR/4000 PROCEDURE NITRATE. 2. The display will show:

Chemical Equilibrium: Finding a Constant, Kc

RayBio Rat TNF-alpha ELISA Kit (For Lysates)

Lab 13.3 Determining K c via Colorimetry

Lab 5: Calculating an equilibrium constant

The Determination of an Equilibrium Constant

Chematest 25. Operator s Manual A Swan Analytical Instruments AG CH-8340 Hinwil/Switzerland ANALYTICAL INSTRUMENTS

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

DR/4000 PROCEDURE. IRON, Total

Determination of an Equilibrium Constant

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

STUDENT LABORATORY Plant Respiration and Photosynthesis

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

Experiment 7. Determining the Rate Law and Activation Energy for the Reaction of Crystal Violet with Hydroxide Ion

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

Computational Study of Chemical Kinetics (GIDES)

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

Determining the Concentration of a Solution: Beer s Law

Kinetics of Crystal Violet Bleaching

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

TITRATION CURVES INTRODUCTION. Read and/or review Sections 4.10 and 16.7 in your textbook.

Golimumab Free Anti-Drug Antibody ELISA

EnAlgae SOP sheet: Silicate - SFA. 1. Purpose This procedure is to analyse seawater and freshwater for silicate, SiO2.

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Measuring ph with Smart Cuvettes

Zearalenone ELISA Kit

CHM 152 updated May 2011 Lab 8: Titration curve of a Weak Acid

DETERMINATION OF AN EQUILIBRIUM CONSTANT

Nitrogen, Total Inorganic

MyQubit Amplex Red Galactose Assay

aa + bb cc + dd Equation 1

TPH (Total Petroleum Hydrocarbons)

Investigating Food Dyes in Sports Beverages. Sample

Chemical Equilibrium: Finding a Constant, Kc

Introduction. Concepts Kinetics Order of reaction Reaction rate Colorimetry. Background

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

C.S.Rye: Mascot Murder Mystery

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

Peracetic Acid (PAA) and Hydrogen Peroxide (H 2 O 2 )

The Effect of Alcohol on Biological Membranes

Spectrometer User s Guide

Zetasizer Nano-ZS User Instructions

TEC. Titration curves and buffering capacity with Cobra4

Experiment 14 It s Snow Big Deal

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

CHEMISTRY 206 Experiment 4: A KINETIC STUDY

Transcription:

Data Sheet SP-700 Free Chlorine Analysis TMB Method The Pyxis SP-700 free chlorine method is based on the USEPA-accepted tetramethylbenzidine (TMB) chemistry for free chlorine analysis. The solidified reagent deposited inside a capped 2-ml disposable pipette contains TMB, a ph buffer, and a polymeric binder. When a water sample is withdrawn to the pipette, the TMB reagent dissolves and reacts with free chlorine in the sample to form a yellow solution. The SP-700 measures the absorbance value of the resulted yellow solution to determine the free chlorine concentration in the sample. Effective 11/1/2017 all SP-700 units will come preprogrammed with the TMB Free Chlorine method. For units purchased prior to this date, Pyxis offers an online firmware upgrade free of charge to enable your SP- 700 to run this test. The procedure for upgrading your SP-700 unit is included in page 6 of this document. Applications Cooling Tower Water samples Domestic Water Samples Features Capped disposal pipette can be handled more easily than a powder pillow Gelled solid reagent avoiding inhaling chemical dust Acidic reaction ph eliminating calcium carbonate/phosphate precipitation common in the DPD method Ordering Information SP-700 P/N: 50301 TMB Free Chlorine Reagent (x 100 tests) P/N: 31053

Specification Items Parameter Range 0.02 2.2 ppm Detection Limit 0.02 ppm Accuracy 0.05 Precision 0.05 ppm (3 sigma) Reaction Time 2 minutes Sample Temperature 50 86 o F (10 30 o C) Sample Volume 2 ml *With Pyxis continuous improvement policy, this specification is subject to change without notice. Test Procedure Video Instructions LINK Via YouTube https://www.youtube.com/watch?v=fyhbepzdixa Free Chlorine Measure Procedure : SP-700 1. Click >> button (labeled with >), until the caption of the left button (labeled with <) becomes COLOR, click the COLOR button to launch chlorine measurement page as Fig 1. Fig 1. Chlorine measurement 2. Triple rinse the sample cell of the SP-700 with the sample to be measured.

3. Fill the sample cell with the water to be measured. 4. Click Zero button (labeled with <) Fig 2. Chlorine Zero 5. Draw out sample water from the sample cell into the reagent pipette. Once the sample has been drawn into the reagent pipette, shake the pipette or squeeze the sample back into the sample cell several times allowing the reagent to fully dissolve. You should notice a color if free chlorine is present. 6. Click Timer button (labeled with >), the SP-700 start 2-minute counter down timer

7. The SP-700 will continuously display the free chlorine concentration, click the Stop button (labeled with >) to stop measurement if the real-time readings remain steady or you may wait for the 2-minute timer to end. RECORD FINAL VALUE as ppm FREE CHLORINE Free Chlorine Calibration Procedure : Pre-Step Click >> button (labeled with >), until the caption of left button (labeled with <) becomes COLOR, click the COLOR button to launch chlorine page Reagent Blank (Zero) Calibration 1. Fill the sample cell with DI water 2. Click Zero button (labeled with <) 3. Draw out DI water from the sample cell into the reagent pipette, shake the pipette to fully dissolve the reagent before squeezing the water sample in the pipette back to the sample cell 4. Click Timer button (labeled with >), the SP-700 will start the 2-minute timer. 5. The SP-700 will continuously display the free chlorine concentration, please click the Stop button (labeled with >) to stop measurement if the real-time readings remains steady or wait for the 2-minute timer to time out. 6. Click the Cal button (labeled with >) to launch chlorine calibration page

Figure 4. Blank Calibration 7. Click Blank button (labeled with <) to start blank calibration. 8. Blank calibration succeeds will be displayed if blank calibration completed. 9. Long press Default (labeled with OK) to return to chlorine page. Slope Calibration 1. Fill the sample cell with known free chlorine standard solution. 2. Click Zero button (labeled with <). 3. Draw the standard solution from sample cell into the reagent pipette, shake the bottle to fully dissolve the reagent before squeezing the reacted sample back into the sample cell. 4. Click Timer button (labeled with >), on the SP-700 to start the 2-minute timer. 5. The SP-700 will continuously display the free chlorine concentration, please click the Stop button (labeled with >) to stop the measurement if the real-time reading remains steady or wait for 2-minute timer to complete. 6. Click Cal button (labeled with >) to launch chlorine calibration page. 7. Click Slope button (labeled with >) to launch slope calibration. 8. Click + button (labeled with <) or button (labeled with >) to adjust free chlorine solution concentration to the target value of the standard used in this procedure

Fig 5. Slope Calibration 9. Click Calib button (labeled with OK) to complete slope calibration. 10. Slope calibration succeeds will be displayed if slope calibration completed. 11. Long press Calib (labeled with OK) to return to chlorine page. Note: Free Chlorine Calibration Standard Solution concentration should be within 1.1 to 2.2 ppm for proper calibration.

FIRMWARE UPDATE for SP-700 to ADD TMB Free Chlorine Test This document describes procedures to upgrade SP-700 firmware via upyxis software over Bluetooth interface. Each SP-700 comes from Pyxis with a Bluetooth adapter for use in your PC/Laptop. This device enables wireless communication from your PC/Laptop to the SP-700 for data transfer and is essential in installing firmware upgrades. If you have lost your Bluetooth adapter, contact Pyxis to receive a replacement at order@pyxis-lab.com Terminology Terminology upyxis Software Description PC software to upgrade and configure SP-700 BTLE Bluetooth Low Energy Revision Component Revision upyxis Software 0.9.31 SP-700 Firmware 1.4.0r230 Download Links upyxis Software: http://www.pyxis-lab.com/resource/software_driver/upyxis_0.9.31.zip SP-700 Firmware: http://www.pyxis-lab.com/firmware.html Note: Click the Download link in the Firmware Download page and save SP700_v1.4.0r230.bin file to your computer.

SP-700 Firmware Upgrading Procedure Click the OK button while holding the LEFT button (labeled with <) to turn the SP-700 on. The SP-700 bootloader starts running and the following screen displays Click the MIDDLE button (labeled with >) to start SP-700 Bluetooth interface, and the following screen displays

Plug in Bluetooth USB adapter to your computer, and launch upyxis software, according to Fig 8. upyxis software will automatically scan and find the SP-700 device. 8 Click the Connect button to connect with the SP-700, Fig 9 displays when the upyxis software has connected to the SP-700 successfully.

Click the Load File button to locate the SP700_v1.4.0r230.bin firmware file saved in the local computer, and then click the Update button to start upgrading the SP-700 meter. It takes about 3 minutes to complete the procedure. Fig 10 displays the upgrading process Once the upgrading procedure is completed, the SP-700 meter will reboot automatically. Your SP-700 is now capable of being used to conduct Free Chlorine TMB method using the procedures found earlier in this document.