User Guide & Technical Information

Similar documents
Chemical Radiological & Explosive. Detection Solutions for First Responders

Chemical Radiological & Explosive. Detection Solutions for First Responders

IDENTIFYING UNKNOWN CHEMICALS IN SCIENCE LABS

Fight against IED making

CONCENTRATED VOLUMETRIC & VOLUMETRIC SOLUTIONS

Lab: Cabbages in Chemistry 3pts ec printing in COLOR / 2pts B&W

What Do You Think? Investigate GOALS

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Bomb-Making Materials Awareness Program (BMAP) Law Enforcement User Guide

Characteristics of Chemical Change

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

BGSU s Guide to Chemical Storage

LAB TEST Physical and Chemical Changes

Experiment 8 - Chemical Changes

Examples of Strong Acids: Strong Acid Formula Common Source Hydrochloric Acid HCl Stomach Acid

More Chemical Changes

Chemical Analysis Instruction Book

1. Potassium Permanganate Test (Baeyer Test)

Chemistry: Soap Article

L Mott SALT WATER AQUACULTURE. Model AQ-4/AQ-5 Code / test kit instruction manual

Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters)

Chlorine, Free and Total, High Range

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

MATERIAL SAFETY DATA SHEET

CLASS-VII DAV PUBLIC SCHOOL SEC-14 & 48 GURGAON SUB: SCIENCE TOPIC: ACIDS, BASES AND SALTS

Post-Show. Chemistry. Periodic Table of the Elements. After the Show. Traveling Science Shows

5 ACIDS, BASES AND SALTS

Chemical Segregation and Storage Guide

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

Magnetic Flowmeter Material Selection Guide

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

Formaldehyde Fluorescent Detection Kit

Name: Date: Number: Acids

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

3/26/2011. explosion

Physical and Chemical Properties and Changes Lab

Acid / Base Titrations

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

DR/4000 PROCEDURE NITRATE. 2. The display will show:

CHLORINE, TOTAL (0 to 4.00 mg/l)

PCBs Lower Chlorinated ELISA Kit

Safe Operating Procedure

Glove Selection Chart

Compound. Math Focus. What are compounds? What is a chemical reaction? How are compounds used in everyday life?

Which fertiliser would improve the quality of this soil most effectively?

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

Physical and Chemical Changes. 3. One of the new materials was a precipitate that settled out of solution.

Chlorine, Free and Total, High Range

Topic Students devise an experiment to determine the types of bonds in three compounds.

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

The Determination of ph of some Common Acids & Bases

Safe Method of Use 1 General Exempt Laboratory Requirements

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Unit 1: Safety in the Laboratory

CHEMISTRY 130 General Chemistry I OXIDATION-REDUCTION CHEMISTRY

RIDASCREEN Aflatoxin B 1 30/15

á191ñ IDENTIFICATION TESTS GENERAL

Name Period Date. Lab 9: Analysis of Commercial Bleach

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Cu-Creatinine- Metol system

2D-Silver Stain Reagent II -For Electrophoresis-

Working with Hazardous Chemicals

R021. BioTector TOC Analyzer Reagents_Mixer Reactor Systems

Chemical Reactions Chapter 8 PART TWO

Topic 5 National Chemistry Summary Notes. Acids and Alkalis

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

Persulfate Digestion Method Method to 40 mg/l N (HR) TNTplus 827

Acidity of Beverages Lab

Core practical 15: Analyse organic and inorganic unknowns

Performance of a Handheld Raman Spectrometer for Explosives Identification. James T. Thurman Associate Professor Eastern Kentucky University

An acidic substance always contains (1) in its name. An (2) is a chemical that changes colour to tell you

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows

Lesson 4. Temperature change

CIE Chemistry A-Level Practicals for Papers 3 and 5

Hepatitis B virus IgM ELISA Kit

ph Calibration Buffers

CHEMISTRY 130 General Chemistry I. Five White Powders & Chemical Reactivity

1 PRODUCT AND COMPANY IDENTIFICATION. Manufacturer. HAZARDS IDENTIFICATION Classification of the Substance or Mixture

Name Date ID. Integrated Physics and Chemistry (1) Interim Assessment Third Grading Period

NITROGEN AND ITS COMPOUNDS Q30 (i) Explain how the following would affect the yield of ammonia. An increase in (i). Pressure.

Chemical Names and Formulas

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

SpillSolv. Chemical Spill Treatment Kits

6.2 The ph Scale and Indicators

Principal Investigator: Department: Laboratory room #s: Updated/revised: Chemical Name Amount Physical state Location Hazard Class

NB/SH/T Translated English of Chinese Standard: NB/SH/T

HAZARD COMMUNICATION PROGRAM

Chemical Safety. Peter Yeung D.G. Manager. Safety Office The University of Hong Kong

HAZARD COMMUNICATION PROGRAM

Chlorine, Free and Total, Low Range

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

Nitrogen, Total Inorganic

RIDASCREEN. Testosteron. Enzymimmunoassay zur quantitativen Bestimmung von Testosteron

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

Transcription:

User Guide & Technical Information Morphix Technologies TraceX Explosives Detection Kit Part Number: 510100 Publication Number 51-0100B.2-1017 Contents For more information, please contact: Warning... 1 Overview... 2 Detection Capability... 2 Virginia Beach, VA 23454 P +1.757.431.2260 F +1.757.431.2255 www.morphtec.com email: customerservice@morphtec.com Technical Information... 3 Sample Collection... 3 Field Use Guidelines... 4 Interferents... 5

Warning While the TraceX Explosives kit is designed to keep all chemicals within its plastic enclosures, human contact with kit chemicals is possible. Do not disassemble kit, reopen kit after use, or ingest any chemicals contained in the kit. If chemicals contact skin or eyes, wash with water and seek medical attention. The kit utilizes ampoules containing solutions (total volume < 2 ml) which may contain strong mineral acids or bases. Dispose of kit following applicable regulations and your organization s disposal policy. Use of the TraceX is subject to the Terms and Conditions of Use and any Warnings printed on the operating instructions. 1

Overview The TraceX Explosives kit is designed to help identify bombers, bomb-makers and their bomb-making facilities. With a single swab, the TraceX Explosives kit allows users to quickly and easily identify the most common homemade explosive materials (HMEs) and their precursors. The kit operates by using a collector to extract compounds from surfaces. The collector is then assayed for explosive-related materials via delivery of detection chemistries to the collector. A color change in the kit window indicates the presence of an explosive-related material. This guide provides information regarding the TraceX Explosive kit, including: Detection capability Technical information Sample collection Field use guidelines Interferents Additional training tools and videos are available by request and can also be found at www.morphtec.com. Detection Capability The TraceX Explosives kit can detect nine families of explosive materials and their precursors (see Table 1), and has been tested against more than 20 specific explosives or precursor materials. While the kit is highly sensitive to explosive related materials at trace levels, it can also be used for bulk detection. The TraceX Explosives kit detects levels at or below 250 nanograms for all HME classes, with the exception of peroxides; sensitivity to peroxides is 750 nanograms. HME Class Table 1. Detection Capabilities Representative Chemicals Nitroaromatics TNT, DNT, Tetryl, picric acid Nitramines & Nitrate Esters Inorganic Nitrates Chlorates & Bromates RDX, HMX, PETN, EGDN, nitroglycerin urea nitrate, ammonium nitrate, black powder potassium chlorate, potassium bromate Peroxides TATP, HMTD Acids Bases Precursor Class Representative Chemicals nitric acid, sulfuric acid, hydrochloric acid potassium hydroxide, sodium hydroxide 2

Technical Information The TraceX Explosives kit was developed by Morphix Technologies under contract from the US Department of Defense, and meets their demanding requirements. Rigorous testing was conducted under simulated field conditions to verify operational performance. Shelf Life Operating Conditions Field Ruggedness Contamination Avoidance User Safety Two year shelf life is based on storing product at room temperature (i.e. 20 C 25 C) Short term excursions between 2 C 50 C are acceptable for up to 2 weeks Kit is operational at temperatures of 2 C 50 C and humidity levels of 10% 95% RH Kit enclosed in protective case Sample plugs on collector are protected from contamination by cover No heat source required Chemicals are contained within the test kit minimizing the risk of user exposure Sample Collection For best results, evaluate the suspect surface to determine the most effective sample collection technique. If the suspect surface is rough, such as cinder block or rough concrete, dab or pat the collector multiple times on the surface. While the collector is made of rugged materials, repeatedly rubbing the collector on a rough surface may damage the collector plugs. If there is visible powder (i.e. bulk powder), gently dab the collector onto the powder two to three times. The TraceX kit is very sensitive to trace levels and too much powder could clog the collector. If the suspect surface is smooth with little to no visible powder, thoroughly swab the surface for 10 to 20 seconds. Morphix recommends using a figureeight pattern when swabbing. Guidelines are illustrated in Figure 1. Trace not visible or barely visible to the human eye Bulk visible amount of suspect material Rough Surfaces e.g. rough concrete or cinder block swab surface thoroughly for 10-20 seconds dab powder 2-3 times dab surface multiple times Figure 1. Guidelines for sample collection using the TraceX Explosives Kit 3

Field Use Guidelines The Trace X Explosives kit was designed to give an unambiguous color change to alert the user of the presence of any materials listed in Table 1 of this guide. The color change will occur in the indication pads located in the kit top. When the kit is operated, all pads will show a slight wetting effect, resulting in the pads changing from white to off-white or light gray; this wetting effect is normal and does not indicate the presence of an explosive. Below is an example of the color change after sampling Nitrates (Figure 2). Although it is not necessary for the user to know the specific color for a positive indication, the typical color for each class at trace levels is included on the kit label and shown in Table 2. The intensity and shade of color can change based on the amount of analyte detected. Figure 2. Close up view of TraceX showing Nitrates indication. Table 2. Typical Color Change by Analyte HME Class Analyte Detected and Expected Color Nitroaromatics (purple) (blue) (orange) TNT DNT Tetryl, picric acid Note: other nitroaromatics or mixtures may cause different colors (e.g. green) Nitramines/Nitrate Esters (pink) RDX, HMX, PETN, EGDN, nitroglycerin Inorganic Nitrates (pink) urea nitrate, ammonium nitrate, black powder Chlorates/Bromates (yellow) potassium chlorate, potassium bromate Peroxides (yellow) TATP, HMTD Acids (purple) nitric acid, sulfuric acid, citric acid, hydrochloric acid Bases (blue) potassium hydroxide, sodium hydroxide The TraceX Explosives kit exhibits a high degree of specificity across all detection channels. There are times, however, when the user may see more than one indication pad change color. This can occur when mixtures are detected or when contamination is present. The following results were observed: - When urea nitrate is present, the Nitrates indication pad will show color and depending on the composition of the urea nitrate sample, the Acid pad may show color. This may allow the user to differentiate between urea nitrate and other nitrates, such as ammonium nitrate, which will only show color on the Nitrates indication pad. - Nitroaromatic materials such as TNT, DNT and Tetryl will produce a color change in the applicable pad, as expected. However, these materials may also produce a color change in the Nitramine/Nitrate Ester pad marked HMX, RDX, EGDN, PETN. If color is observed in both pads, a nitroaromatic material is present, but a nitramine/nitrate ester may not be. - While chlorates or bromates will show a yellow color in the Chlorates/Bromates pad, as expected, they can also cause a browning effect in the pad marked Nitrates or the pad marked HMX, RDX, EGDN, PETN when bulk sampling is performed. This browning effect has been observed only with chlorates and bromates. Additionally, the HMTD, TATP indication pad may produce a color change when sampling bulk levels of a chlorate or bromate. 4

Interferents A series of potential interfering substances were sampled using the TraceX Explosives kit. These included common household products and chemicals sometimes associated with the manufacture of explosives. Materials were evaluated for their potential to generate a false negative or false positive result. A list of the field interferents that were evaluated is provided in Table 3. Table 3. Field Interferents Tested Field Interferent Powdered sugar Table salt Urea Baking soda Baking powder Aluminum powder Potassium permanganate Wheat flour Cumin Turmeric Fertilizer Ferric nitrate N,N-Diethyl-meta-toluamide (DEET) Composition (color) food grade: sugar & corn starch (white) food grade: sodium chloride, non-iodized (white) reagent grade (white) food grade: sodium bicarbonate (white) food grade: corn starch, sodium bicarbonate, sodium aluminum sulfate, monocalcium phosphate (white) reagent grade (gray) reagent grade (purple) food grade: unbleached (tan) food grade (yellow) food grade: (yellow) commercial lawn fertilizer ~18% nitrogen (brown) reagent grade (off-white) reagent grade (colorless) - White substances such as sugar, table salt, baking soda, urea, and baking powder showed no impact on the kit. - When colored substances, such as unbleached wheat flour, aluminum powder, cumin, and turmeric were tested, color was visible in all indication pads due to transfer or solvation of the test material. It is highly unlikely, however, that an explosive or precursor would cause a color change on all indication pads. This means that if the user observes the same color on all indication pads after sampling colored material, it is highly probable that an explosive or precursor was not detected. o o Aluminum powder may show a gray color in all of the pads. However, if an explosive material is also present, the user will generally see a color change in the appropriate pad. For instance, if both aluminum powder and chlorates are present, all indication pads will show gray, while the Chlorate/Bromate pad will show yellow with gray. Similar to aluminum powder, dirt and dust may show a brown-gray color in all of the pads. However, if an explosive material is also present, the user will generally see a color change in the appropriate pad. For instance, if the user swabs a dirty surface that also contains TNT, all indication pads will show brown-gray, while the Nitroaromatic pad will show purple with brown-gray. - A positive result for Nitrates was observed when nitrate-containing field interferents, ferric nitrate and lawn fertilizer, were evaluated. All nitrate salts are expected to give a positive result. - A positive result for Nitrates and Nitroaromatics was observed when bulk levels of DEET were tested. - Potassium permanganate is both highly reactive and highly colored, resulting in variable colors on all indication pads if present. About Morphix Technologies Morphix Technologies is a privately-owned, ISO 9001:2008 certified, American business that develops, manufactures and sells colorimetric chemical detection products that are easy to use, lightweight and inexpensive. These sensors save lives of military, law enforcement, emergency response and industrial personnel worldwide. 5