When fluid incompressible...flow velocity, volumetric, and mass flow are proportional.

Similar documents
CHAPTER (13) FLOW MEASUREMENTS

Strain, Force, and Pressure

Industrial Instrumentation Prof. A. Barua Department of Electrical Engineering Indian Institute of Technology Kharagpur. Lecture - 14 Flowmeter ΙΙΙ

Applied Fluid Mechanics

Applied Fluid Mechanics

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

HYDRAULIC STRUCTURES, EQUIPMENT AND WATER DATA ACQUISITION SYSTEMS Vol. II Flow Measuring Techniques - Andreas Müller

Discharge measurements

Control Engineering BDA30703

Given Find Water Properties

Transducers. ME 3251 Thermal Fluid Systems

ECNG3032 Control and Instrumentation I

By-Pass. This voltage is proportional to the liquid level (threewire potentiometer circuit). The resistance reading can

1. Mark the correct statement(s)

Given Find Water Properties

MCE380: Measurements and Instrumentation Lab

Instrumentation & Data Acquisition Systems

Flow Measurement: Physical principle employed in various types of flow meters. PART 4 PREPARED BY: ESO OLUWATOBILOBA

Unit 57: Mechatronic System

FLOW MEASUREMENT INC 331 Industrial process measurement 2018

An Essential Requirement in CV Based Industrial Appliances.

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters

Flow Measurement in Pipes and Ducts COURSE CONTENT

COURSE OF Prepared By: MUHAMMAD MOEEN SULTAN Department of Mechanical Engineering UET Lahore, KSK Campus

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11

Flowmeter Discharge Coefficient Estimation

Lab 3 Revisited. Zener diodes IAP 2008 Lecture 4 1

Introduction EE 224: INTRODUCTION TO DIGITAL CIRCUITS & COMPUTER DESIGN. Lecture 6: Sequential Logic 3 Registers & Counters 5/9/2010

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class #

Laboratory exercise 1: Open channel flow measurement

INSTRUMENTAL ENGINEERING

Objective Type Questions Instrumentation System & Devices (IDS)

Experiment- To determine the coefficient of impact for vanes. Experiment To determine the coefficient of discharge of an orifice meter.

Roll No. :... Invigilator s Signature :.. CS/B.Tech (EIE)/SEM-5/EI-501/ INDUSTRIAL INSTRUMENTATION II

University of Engineering and Technology, Taxila. Department of Civil Engineering

FLOW MEASUREMENT IN PIPES EXPERIMENT

VALLIAMMAI ENGINEERING COLLEGE

Fundamentals of Flow Metering

Flow Measurement in Pipes and Ducts COURSE CONTENT

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

Flow : the motion of a fluid (1) Blood flowmeters : - ultrasonic (doppler, transit time) -electromagnetic (2) Gas flowmeters : - pneumotachometer

Temperature Sensors & Measurement

Detection range and accuracy specs.

GATE 2001 Instrumentation Engineering

NATIONAL CERTIFICATE (VOCATIONAL) NQF LEVEL

Lecture23. Flowmeter Design.

Digital Signal 2 N Most Significant Bit (MSB) Least. Bit (LSB)

DUBLIN INSTITUTE OF TECHNOLOGY Kevin Street, Dublin 8.

Measurements & Instrumentation. Module 3: Temperature Sensors

Theory and Design for Mechanical Measurements

Transducers. EEE355 Industrial Electronics

Signal types. Signal characteristics: RMS, power, db Probability Density Function (PDF). Analogue-to-Digital Conversion (ADC).

EXPERIMENT ET: ENERGY TRANSFORMATION & SPECIFIC HEAT

Digital Circuits and Systems

Lecture 3 The energy equation

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras

Volume and Mass Flow Rate Measurement Author: John M. Cimbala, Penn State University Latest revision: 07 December 2007

Siddharth Institute of Engineering & Technology

Experiment No.4: Flow through Venturi meter. Background and Theory

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale

LECTURE 28. Analyzing digital computation at a very low level! The Latch Pipelined Datapath Control Signals Concept of State

Approximate physical properties of selected fluids All properties are given at pressure kn/m 2 and temperature 15 C.

PHYS225 Lecture 9. Electronic Circuits

Information for Physics 1201 Midterm I Wednesday, February 20

UNIVERSITY OF BOLTON SCHOOL OF ENGINEERING BENG (HONS) ELECTRICAL & ELECTRONICS ENGINEERING EXAMINATION SEMESTER /2018

Digital Electronic Meters

FLUID MECHANICS. Chapter 3 Elementary Fluid Dynamics - The Bernoulli Equation

New Website: Mr. Peterson s Address:

Experiment (4): Flow measurement

ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina

Measurement and Industrial Instrumentation

Solar Flat Plate Thermal Collector

ELCT201: DIGITAL LOGIC DESIGN

Lesson 10. Thermomechanical Measurements for Energy Systems (MENR) Measurements for Mechanical Systems and Production (MMER)

9.1 Introduction. 9.2 Fluid Flow. CHAPTER 9 Flow

ME332 FLUID MECHANICS LABORATORY (PART I)

To: Mitch Cottrell, Instructor From: Brian Garber, Crawford Binns, Jeff Hollis (Group 3, Sec. J) Subject: Project Deliverable #3 Date: 4 May 2010

Process Control & Design

FLOWMETRY FLOWMETRY. FLUID-FLOW MEASUREMENT AND VISUALISATION

Experiment A4 Sensor Calibration Procedure

NAME SID EE42/100 Spring 2013 Final Exam 1

Sequential Circuits Sequential circuits combinational circuits state gate delay

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

Theoretical Competition

Calibration of Orifice Flow Meter and Venturi Flow Meter

Flow Measurement in Pipes and Ducts

Hydraulic Fundamentals Hydraulics Definition Advent of Oil Hydraulics Pascal s Law Pressure

Physics Curriculum Map

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

If a stream of uniform velocity flows into a blunt body, the stream lines take a pattern similar to this: Streamlines around a blunt body

National Exams May 2016

Digital Electronics II Mike Brookes Please pick up: Notes from the front desk

Memory Elements I. CS31 Pascal Van Hentenryck. CS031 Lecture 6 Page 1

IDEA Campus Energy 2016

COURSE CODE : 3072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

Compressible Gas Flow

Lecture Fluid system elements

Physics 6b Winter 2015 Final Campagnari Section Test Form D

Physics 6b Winter 2015 Final Campagnari Section Test Form A

Transcription:

11-1 Flow 11-1 Measures of Fluid Flow Flow velocity. Speed of material flowing past a plane. Volumetric flow. Volume of material passing a plane per unit time. Mass flow. Mass of material passing a plane per unit time. When fluid incompressible......flow velocity, volumetric, and mass flow are proportional. Types of Flowing Fluids to be Measured Liquid in closed conduit. (E.g., water in a pipe.) Liquid in an open conduit. (E.g., water in a canal.) Gas in an closed conduit. Slurry (solids suspended in liquids) in a closed conduit. Different transducers may be required for each situation. 11-1 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-1

11-2 11-2 Some Major Types of Sensors Rotation. Fluid forces an object placed in flow to rotate. Speed of rotation is measured. Obstruction. Fluid flow is partially obstructed. Pressure is measured on both sides of obstruction, flow rate deduced. Heat dissipation. A heating element is placed in the flow. Flow rate deduced by amount of heat removed. Head. Measure fluid level flowing into a drop. 11-2 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-2

11-3 11-3 Rotation Sensors Force of flow causes some object to rotate. Two types will be discussed, turbine and paddle wheel. Turbine Type Used to measure volumetric flow in a closed conduit. Typical Construction. Turbine placed in flow in a plastic section of pipe. Turbine blades made of metal. Magnetic reluctance transducers placed outside pipe near blades. Flow causes turbine to spin. Rate of spin measured by magnetic reluctance sensor. 11-3 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-3

11-4 11-4 Model Function This includes the turbine, the magnetic reluctance sensor, a conditioning circuit, and a frequency counter. H t1 (x) =kx, where k is a constant called the k factor, having units of one over volume. Paddle Wheel Used to measure volumetric flow in an open conduit. Consists of a wheel partially immersed in the flow. Flow causes wheel to turn. Same model function as turbine flow meter. 11-4 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-4

11-5 11-5 Paddle Wheel/Speed Measurement Example Design a system to convert process variable x [0, 80 ml s ],flowina pipe, into a floating-point number H(x) to be written into variable paddleflow, whereh(x) =x s ml. The value must have a precision of ±0.1 ml s. Use an FP-2502 paddle-wheel flow sensor. Solution Overview Flow sensor generates a voltage pulse train. Digital comparator converts to logic level. Counter counts pulses. At regular intervals count transfered to register, and counter reset. At irregular intervals interface routine reads register and completes conditioning. 11-5 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-5

11-6 11-6 The FP-2502 Flow Sensor Output pulse minimum 2 V. For each ml flow there are 8.5 pulses. [ Measurable range, 50 ml ] ml, 6000. min min Cost, $530. Design Decisions Threshold for digital comparator. Number of bits in counter and register. Amount of time between samplings of counter. Interface routine. Digital Comparator Threshold Set negative input to slightly less than 2 V. 11-6 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-6

11-7 11-7 Counter Contents Let H ctr (x, t) give the counter value t time after being reset, where x is the flow rate. Then, H ctr (x, t) =xkt, where k = 8.5. (This assumes that x is constant ml while the counter is counting.) Let t c denote the amount of time that the counter counts before its contents are transfered to the register. Let H r (x) give the value clocked into the register. Then r = H r (x) =H ctr (x, t c )=x 8.5 ml t c. This value will be read by the interface routine. Solving for x yields x = r ml 1. 8.5 t c To obtain H f : H f (H r (x)) = H(x) ( H f (r) =H r ml ) 1 8.5 t c = s ml r ml 1 8.5 t c 1 = r s 8.5t c 11-7 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-7

11-8 11-8 To complete the solution choose t c and the number of bits in the counter and register. Precision goal is ±0.1 ml s. Smallest change in r is ±1. Therefore constraint H f (r) H f (r 1) 0.1 must hold. Applying H f, 1 1 s(r (r 1)) 0.1. 8.5 t c As a safety margin, solve 1 1 s=0.025. 8.5 t c t c =4.706 s. Then, H r (80 ml s ) = 3200. Therefore a 12-bit counter is needed. Interface routine code: r = readinterface(); paddleflow = r * 0.025; 11-8 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-8

11-9 11-9 Obstruction Flow Meters Used to measure volumetric flow in closed conduits. Typical Construction An obstruction placed in pipe. Obstruction might be: a plate with hole in center (called an orifice plate) or a carefully shaped venturi tube. Obstruction causes a pressure difference. Pressure difference measured with a differential pressure sensor. Flow rate deduced from differential pressure. 11-9 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-9

11-10 11-10 Model Function Consider an obstruction flow meter in which: the pipe is in a horizontal position, the fluid is incompressible and of density δ, the area at point 1 is A 1, the area at point 2 is A 2, and the pressure at point 1 is P 1 and the pressure at point 2 is P 2. The model function for such a transducer is H t1 (x) =x 2 δ(1 (A 1/A 2 ) 2 ) 2C 2 d A2 1 = P 2 P 1, where C d is a constant called the discharge coefficient. In an ideal transducer, C d =1. For a typical venturi tube, C d =.97 and for a typical orifice plate, C d =.6. 11-10 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-10

11-11 11-11 Example Problem Convert the process variable x [ 0 l min, 1000 min] l, volumetric flow of water in a 50 mm diameter pipe, to a floating point number H(x) stored in variable vflow where H(x) =x min l.useanomegabrand PX 820-070DV differential pressure sensor and an ADC with response H ADC(10 V,10). Solution Diagram: 11-11 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-11

11-12 11-12 Solution Overview: Use an orifice plate flow transducer. Call area of orifice A 1. Call response and output of flow transducer y = H t1 (x) =x 2 δ(1 (A 1/A 2 ) 2 ) 2Cd 2. A2 1 Use the differential pressure transducer to convert pressure difference to voltage. Response of Omega brand PX 820-070DV differential pressure sensor is z = H p (y) = y p max 100 mv for a 5 V excitation and for y [0,p max ] where p max = 5 bar. 11-12 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-12

11-13 11-13 Solution Overview: Use an instrumentation amplifier to amplify the voltage for the ADC. Response is w = H c (z) =gz. (Symbol g is being used for gain instead of A.) Use the ADC and an interface circuit to prepare the data for the computer. Response is r = H ADC(10 V,10) (w) = w 10 V 1023. Write an interface routine, H f, to produce the desired output: H f (H ADC(10 V,10) (H c (H p (H t1 (x))))) = H(x) =x min. l 11-13 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-13

11-14 11-14 Constraints and Solution Plan: Choose orifice diameter so that differential pressure is in range [0,p max ]: 0 H t1 (x) p max =5bar for x [ 0 l min, 1000 l ] min Choose amplifier gain, g, so that ADC input is in range [0, 10 V]: 0 H c (H p (H t1 (x))) 10 V for x [ 0 l min, 1000 l ] min Write interface routine to get desired output. 11-14 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-14

11-15 11-15 Orifice Plate Diameter To make full use of the pressure sensor s dynamic range...... choose A 1 so that: 0 H t1 (x) p max =5bar 0 x 2 δ(1 (A 1/A 2 ) 2 ) 2C 2 d A2 1 p max =5bar, where δ =1 g cm 3, A 2 = π(25 mm) 2 and C d =.6. Solve H t1 (x max )=p max for A 1 : A 1 = 1 A 2 2 δ 2 p max ( xmax C d ) 2 1 2 =0.0008018 m 2 Or, orifice diameter is 31.95 mm. 11-15 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-15

11-16 11-16 Amplifier Gain To avoid confusion with A 1 and A 2...... let g denote amplifier gain. Choose amplifier gain so that: 0 H c (H p (H t1 (x))) 10 V Since each function is monotonic and has a positive slope: H c (H p (H t1 (x max ))) = 10 V Substituting p max for H t1 (x max ): H c (H p (p max )) = 10 V Applying functions: g p max p max 100 mv = 10 V, so g = 100. 11-16 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-16

11-17 11-17 Interface Routine Output of ADC: r = H ADC(10 V,10) (H c (H p (H t1 (x)))) ( ) 2 ( = (210 1) 100 mv δ x 1 g 10 V 5bar 2 C d A 2 1 ) 1 A 2 2 Solving for x yields 10 V x = 2 10 1 = 1 g m6 2.718 10 7 s r 2 ( 5bar 2 1 100 mv δ C2 d A 2 1 ) 1 1 A 2 r 2 Need to find H f such that: H f (H ADC(10 V,10) (H c (H p (H t1 (x))))) = H(x) =x min l Substituting, H f (r) =H Interface routine: ( ) m6 2.718 10 7 s 2 r =0.0005212 m3 s r = readinterface(); vflow = 31.27 * sqrt( r ); = min r =31.27 r l m6 2.718 10 7 s 2 r min l 11-17 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-17

11-18 11-18 Other Flow Transducers Hot-Wire Anemometer Used to measure mass flow in a closed or open conduit. Construction: A thermistor, RTD, or other self-heating temp. transducer placed in flow. Fluid carries heat away from temperature transducer. Transducer is maintained at a constant temperature by a feedback circuit. Current is related to flow rate. No model function or circuit will be given. 11-18 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-18

11-19 11-19 Two-Temperature Transducer Flow Meter Used to measure mass flow in a closed or open conduit. Construction: Two temperature transducers placed in fluid. One is exposed to flow. The other is exposed to stationary fluid. Transducers are connected in a bridge configuration. No model function or circuit will be given. 11-19 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-19

11-20 11-20 Weir Flow Meter Used to measure volumetric flow in open conduits. Construction: Water flows in an open conduit (like an aqueduct), over a drop. Shape of cut over which water falls is specially chosen. Flow rate determined by height of water. Model Function For a rectangular cut, H t1 (x) =kx 2/3. For a V-notch cut, H t1 (x) =kx 2/5. 11-20 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-20

11-21 11-21 Slurry Flow Measurement Methods Flow contains a suspension of particles. For example, coal mixed with water, water with air bubbles, etc. Sonar. Measures flow velocity. Sound injected nearly parallel to the direction of flow. Microphones pick up reflected sound. Speed determined by Doppler shift. Cross correlation. Measures flow velocity. Some property is measured at two points in the flow, for example electrical resistance. Let the two points be separated by a distance d. Let p 1 (t) be the property measured at point 1 and time t. Let p 2 (t) be the property measured at point 2 and time t. The interface routine finds a t such that p 1 (t) p 2 (t + t) for some range t [t 1,t 2 ]. The flow velocity is then d/ t. 11-21 EE 4770 Lecture Transparency. Formatted 8:20, 24 February 1999 from lsli11. 11-21