Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ

Similar documents
Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis

Highly Sensitive and Rugged GC/MS/MS Tool

An Optimal Method for the Analysis of Pesticides in a Variety of Matrices

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Screening for Hundreds of Pesticide Residues Using a GC/Q-TOF with an Exact Mass Pesticide Database in Food

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Rugged GC/MS/MS Pesticide Residue Analysis Fulfilling the USDA Pesticide Data Program (PDP) Requirements

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

The Era of Mass Surveillance

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

GC/Q-TOF MS Surveillance of Pesticides in Food

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

GC/MS/MS Dioxin and Dioxin-like PCBs in Feed and Food. Jessica Westland, LSAG Applications Chemist

ENVIRONMENTAL analysis

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

Workflow Using Hyphenated Mass Spectrometry Techniques

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Application Note No Introduction. DMI Instrumentation. DMI Method. DMI for Lettuce and Pea Extracts. Lettuce results

Self Cleaning Ion Source and other Innovations in Mass Spectrometry. Kirk Lokits (GCMS Applications Chemist) Blacksburg, VA February 2 nd, 2017

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Application Note. Abstract. Authors. Introduction. Food Safety

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Date ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY

Multi-residue analysis of pesticides by GC-HRMS

U.S. EPA Method 8270 for multicomponent analyte determination

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Agilent All Ions MS/MS

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

Application Note. Authors. Abstract. Xin Sun Shandong Agriculture University, Taian, , China

2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

USP<467> residual solvents

Challenging Pesticide Analysis Using an Agilent J&W DB-35ms Ultra Inert GC Column

Agilent G3212 GC-APCI Source

Evaluating CLP and EPA Methods for Pesticides in Water Using Agilent J&W DB-CLP1/DB-CLP2 GC Columns

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Theory and Practical Consequences.

The new Water Screening PCDL

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa

Agilent MassHunter Quantitative Data Analysis

Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Organochlorine Pesticides by GCxGC-ECD

Agilent 5977A Series GC/MSD System

Application Note. Author. Abstract. Introduction. Food Safety and Environmental

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Fast and Accurate Analysis of PBDEs in a Single Run, Including

MassHunter TOF/QTOF Users Meeting

Agilent s New 7000B Quadrupole GC/MS/MS:

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Agilent Intuvo 9000 Gas Chromatograph System

Electron Ionization Source Parameters in GC-MS

High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Expectations for GC-MS Lab

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF

Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques

Fast, Accurate Environmental Testing

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Useful GC/MS Sensitivity for Improved Environmental Analyses. GC/MS Agilent Restricted

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Fast and Accurate EPA 8270 Quantitation Using Deconvolution

Analysis of BTEX in Natural Water with SPME

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Simultaneous determination of 74 kinds of pesticides in Chinese herbal medicine listed in Chinese pharmacopoeia (2015) by GPC-GC-MS/MS

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Agilent Technologies LCMS Portfolio

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Transcription:

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ Courtney Milner, Ph.D. Agilent Technologies Santa Clara, CA ASMS 2018 VIP Session 1

Agenda Pesticide analysis trends Targeted vs. untargeted analysis What makes the Intuvo 9000 GC unique Intuvo/7000D GC/TQ with P&EP MRM database and methods Sample results 2

Forces driving increased pesticide residue analysis Population growth To meet expected demand in 2050, agricultural production needs to increase by 50% vs 2013 Globalization Globalization of food supply chain means exporters must accommodate many differing local regulations Brand Protection Negative Press can have lasting effect on Brand success 3

Why it s important to do suspect/unknowns screening EU-banned pesticides found in food in Sweden Traces of banned pesticides have been found in oranges from Spain, olive oil and grapes from Greece, apples from Belgium and cucumbers from Holland. Radio Sweden: https://sverigesradio.se/sida/artikel.asp x?programid=2054&artikel=6395318 Developing World Still Struggling With Obsolete Pesticides Adam Allington in Bloomberg BNA ; https://www.bna.com/ developing-world-struggling-n73014471020/ Fipronil in eggs European Crop Protection Association http://www.ecpa.eu/stewardship/counterfeit-illegal-pesticides 4

Targeted v s untargeted Analysis? Non-targeted Targeted Data Acquisition: Targeted Analyte-specific No Analysis analyte-specific conditions conditions Question asked Is it in the sample? Known Full Scan Retention time Data SIM Analysis or MS/MS Database searching Data Analysis Library searching Non-targeted Target Molecular list Analysis of formula compounds calculation Question asked What is in the sample? Spectral interpretation

The nature of target compounds guides technology choice Target Screening quantifying a set list of pesticides in sample to meet regulation Typically domain of GC/SQ or GC/TQ but can be GC/Q-TOF Suspect Screening Screen sample for a range of pesticides Quant if standards available Can be GC/SQ or GC/Q- TOF Non-targeted Screening investigate nature of sample through exploratory profiling Typically domain of GC/Q- TOF but can be GC/SQ 6

Multiple Pesticide Solutions Depending on Need Intuvo-7000D GC/TQ 5977B GC/MSD Knowns New P&EP Applications Kit With Intuvo MRM Database 7250 GC/Q-TOF Enhanced PCDL for Pesticides & Environmental Pollutants Unknown Unknowns 7

Target Analysis System Intuvo-7000D GC/TQ with P&EP MRM database and methods 8

Agilent Food and Environmental MRM Databases 1161 Total Compounds Up to 10 transitions/compound Over 7,500 Matrix optimized transitions Classes of Compounds in the Database Compound Classification Total Number Pesticides 675 Breakdown Products 42 Deuterated Compounds 6 Polybrominated Diphenyl Ether (PBDE) 4 Polybrominated Biphenyl (PBB) 1 Polychlorinated Biphenyl (PCB) 209 Polycyclic Aromatic Hydrocarbon (PAH) 26 Phthalates 17 Additional Semi-volatile Pollutants 94 *Note that some compounds overlap classes. *Note that not every compound class is listed Only higher priority classes are listed

Targeted Screening System Intuvo-7000D GC/TQ with P&EP MRM database and methods Backflush methods reduce system downtime 10

Targeted Screening System Intuvo-7000D GC/TQ with P&EP MRM database and methods Confident compound detection using dmrm methods Backflush methods reduce system downtime 11

Targeted Screening System Intuvo-7000D GC/TQ with P&EP MRM database and methods Intuvo-specific 1100+ compound MRM database Confident compound detection using dmrm methods Backflush methods reduce system downtime 12

Targeted Screening System Intuvo-7000D GC/TQ with P&EP MRM database and methods 13

Targeted Screening System Intuvo-7000D GC/TQ with P&EP MRM database and methods Direct heating 14

Targeted Screening System Intuvo-7000D GC/TQ with P&EP MRM database and methods No-trim column Direct heating 15

Targeted Screening System Intuvo-7000D GC/TQ with P&EP MRM database and methods Ferrule-free click-and-run connections No-trim column Direct heating 16

Targeted Screening System Intuvo-7000D GC/TQ with P&EP MRM database and methods Disposable Guard chip Ferrule-free click-and-run connections No-trim column Direct heating 17

Targeted Screening System Intuvo-7000D GC/TQ with P&EP MRM database and methods Modular Intuvo flow chips Ferrule-free click-and-run connections Disposable Guard chip Low power consumption No-trim column Direct heating Small footprint 18

Intuvo Backflush made easier

Benefits of Backflush GC Methods Mid-Column Backflush 20

A Choice of Methods - 20 minute method - Target screening of less than 300 compounds - 40 minute method - For the most comprehensive coverage - Both with mid-column backflush

Intuvo-7000D GC/TQ Acquisition Methods Agilent 9000 Intuvo GC Parameter Value Inert flow path configuration Mid-column backflush Syringe 10 µl (p/n G4513-80220); PTFE-tip plunger Sandwich injection Reversed 3-Layer Switch (L3,L1,L2) L1 (standard or sample) 0.5 µl L2 (ISTD) 0.5 µl L3 (matrix) 0.5 µl Carrier gas He Inlet MMI Injection mode Pulsed Splitless Purge flow to split vent 30 ml/min at 1 minutes Septum purge flow 3 ml/min Gas saver 20 ml/min after 2 minutes Intuvo Guard Chip Track Oven Columns Agilent Intuvo HP5-MS UI (19091S-431UI-INT) Column constant flow 1.2 ml/min (column 1) & 1.4 ml/min (column 2) Oven temperature program 60 C (hold 1 min) then 40 C/min to 170 C, then 10 C/min to 310 C (hold 3 min) Midcolumn Backflush Timing 5 min duration during post-run Oven temperature 310 C Aux EPC pressure ~30 psi Inlet pressure ~2 psi Agilent 7000C Triple Quadrupole GC/MS/MS Parameter Value Tune file atunes.eiex.tune Transfer line 280 C Source temperature 280 C Quad temperatures 150 C Collison Cell Gas Flows 1.5 ml/min N2 & 2.25 ml/min He Scan Type dmrm Electron Energy 70 ev EM gain 10 MS1 & MS2 resolution Wide Quant/Qual transitions P&EP Intuvo MRM Database Right & Left RT Deltas 0.2 min Dwell times Optimized by dmrm Min Dwell Time (ms) 10 Cycles Per Second 3.07 22

Optimized Sample Prep 23

Confident Results Accuracy and Precision Observations 12 replicates @ ~ 25 ppb Variability: Honey & Rice std dev < 1.06 Tea std dev < 6.00 Tea experienced higher %RSDs Recovery errors 30% 2-Phenylphenol at ~25ppb in Rice CMPD Honey Recovery Rice Recovery Tea Recovery %RSD % Error %RSD % Error %RSD % Error EPTC 8.70 7.12 10.16 9.09 12.70 10.42 2-Phenylphenol 5.26 4.78 7.78 6.19 11.16 9.37 Propachlor 6.98 6.15 11.70 9.51 29.58 25.96 Simazine 6.77 4.82 11.78 9.81 27.06 22.48 Atrazine 7.57 6.71 15.50 12.95 25.07 21.50 Chlorpyrifos-methyl 4.40 3.12 12.68 10.59 27.24 23.84 Alachlor 3.23 2.58 16.12 13.03 25.23 18.13 Heptachlor 9.01 8.04 9.92 7.93 28.56 27.74 Metalaxyl 3.54 3.00 16.64 14.04 25.28 17.52 Metolachlor 5.13 4.10 13.55 11.73 17.40 15.05 Aldrin 6.19 4.64 8.70 6.99 17.71 13.25 Heptachlor exo-epoxide 3.34 2.54 11.85 9.37 23.99 19.83 Chlordane-trans 8.43 7.41 16.78 14.12 22.62 17.07 Myclobutanil 11.53 9.12 11.10 9.13 27.21 24.91 Endosulfan II (beta isomer) 15.31 13.96 8.88 6.86 29.24 24.10 DDT-o,p' 17.66 16.84 8.14 5.70 29.81 27.46 Nuarimol 8.61 7.03 6.28 4.75 18.61 17.93 Tetradifon 14.06 9.86 8.53 7.09 21.75 17.54 Permethrin, (1R)-cis- 24.26 23.75 6.36 5.48 21.49 21.49 Permethrin, (1R)-trans- 17.02 15.43 9.45 9.05 29.32 26.17 24

Meeting EU MRL Requirements Quantitation of pesticide residues at the low ppb level - Honey Overlay of MRM transitions for DDT-o,p at 5ppb in Honey Separated extracted ions of MRM transitions for DDT-o,p at 5ppb in Honey 25

Meeting EU MRL Requirements Quantitation of pesticide residues at the low ppb level - Tea Overlay of MRM transitions for alachlor at 5ppb in Honey Separated extracted ions of MRM transitions for alachlor at 5ppb in Honey Overlay of MRM transitions for chlordane at 5ppb in Honey Separated extracted ions of MRM transitions for chlordane at 5ppb in Honey

Repeatability and robustness Honey Blue Initial 50ng/mL calibration check Red - following 60 honey extract injections. Green - following liner and guard chip replacement.

Repeatability and robustness Rice Blue Initial 50ng/mL calibration check Red - following 60 rice extract injections.

Repeatability and robustness Black Tea Blue Initial 50ng/mL calibration check Red - following 60 black tea extract injections. Green - following liner and guard chip replacement.

Repeatability and robustness Butylate in Jasmine Rice 5.19ppb MRM 156.0 -> 57.1 8 Replicates MRM 146.1 -> 90.0 MRM 146.1 -> 57.1

Repeatability and robustness Fenson in Organic Honey 5.08ppb MRM 141.0 -> 77.1 8 Replicates MRM 267.9 -> 77.1 MRM 267.9 -> 141.1

Repeatability and robustness Chlorfenson in Organic Honey 5.08ppb MRM 175.0 -> 111.0 8 Replicates MRM 111.0 -> 75.0 MRM 177.0 -> 113.0

Jetclean Jetclean self-cleaning ion source can reduce maintenance time significantly Minimizes the need to vent and manually clean the system Very low usage of H2 Multiple modes of operation Ability to schedule at any time Concurrent Mid sequence End of sequence 2.30 am on Monday before we come to work for the week

Suspect Screening Agilent 7250 GC/Q-TOF 34

Expanded Pesticides PCDL GC/Q-TOF Personal Compound Database and Library ~1000 compounds Pesticides and Environmental Pollutants Retention time information Extensive metadata High resolution, curated accurate mass spectra Also included with Pesticides PCDL Pesticides Workflow Guide Comprehensive guide to implement a dual qualitative and quantitative screening approach Two GC Methods A pair of optimized GC Methods developed in conjunction with leading experts Sulfotep 35

Responses Quantitative Linear Dynamic Range Fonofos - 10 Levels, 10 Levels Used, 32 Points, 32 Points Used, 0 QCs x10 7 y = 10221.077352 * x - 2814.193685 R^2 = 0.99919803 1.05 Type: Linear, Origin: Ignore, Weight:1/x 1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0-0.05-0.1 matrix: avocado 50.0 ng/ml 20.0 ng/ml 10.0 ng/ml 5.0 ng/ml 1.0 ng/ml 0.5 ng/ml 100.0 ng/ml 200.0 ng/ml 500.0 ng/ml 1,000.0 ng/ml -50 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 Concentration (ng/ml) Compound: Fonofos High Resolution Library 3.5+ Orders of Magnitude Linear Dynamic Range in complex matrix Excellent Linearity Consistent Response Factors 36

Identifying compounds RT diff Mass accuracy S/N EIC Alignment Fragment Ratio 37

Increased Productivity Options Intuvo-7000D GC/TQ 5977B GC/MSD Knowns New P&EP Applications Kit With Intuvo MRM Database 7250 GC/Q-TOF Enhanced PCDL for Pesticides & Environmental Pollutants Unknown Unknowns 38

Thank you! 39