Technical Documentation Swirl Diffusers Series DLA

Similar documents
Swirl Diffusers Type DLA 7 and DLA 8

Industrial Air Diffuser Type DLD for Heating and Cooling

Technical Documentation Constant flow rate controllers type VRW and VRX. Self operated

AIR TECH SYSTEMS. Technical Brochure. LTG Air Diffusers. Linear air diffusers LDB. Installation in ceilings, walls and sills

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Industrial Air Diffuser Type DLD for Heating and Cooling

Air distribution systems. Adjustable radial outlet RA-V...

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Krantz. RL-C2 radial slot outlet. Air distribution systems

Air distribution systems. Linear whirl outlet WL...

Air distribution systems. Radial outlet RA-N2...

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Displacement Flow Diffusers

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.

Tangential Fans Series TW Impeller diameter 150 mm and 200 mm

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

Nozzle diffuser. Dimensions

Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air.

Nozzle diffuser. Dimensions

NOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16

Swirl diffusers, Variable swirl diffusers

Grille. Min. - max. dimensions

Dimensions. Order code. Materials and finish. lindab ceiling diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8

Variable swirl diffusers

ALC. ALBATROSS Supply air terminal for large airflows

Slot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot

Air distribution systems. Adjustable induction outlet IN-V...

Plain diffuser. Dimensions

Plain diffuser. Dimensions

Supply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side.

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16

GTH. Rectangular double deflection grille QUICK FACTS

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m

Multi-cone diffuser. Dimensions

series FLOOR

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

SWIRL DIFFUSERS SWIRL DIFFUSERS OD-8

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.

Ventilating grilles, Ventilating valves

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS

Circular duct grille

Siv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work

Linear ceiling diffuser

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air

Step Impulse Diffuser Model SIA

VK2 volume flow controller Overview

2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en)

CIRCO. Sound-attenuating transfer unit QUICK FACTS

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

FRB. Exposed passive chilled beam for suspended installation

Linear diffuser. Description

series 50-PR Square perforated face diffusers

STAIRCASE SWIRL DIFFUSERS

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.

DBQ Painted four four-way square square diffuseurs M A D E L

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

Valve Supply and exhaust air

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

SV-2, SV-1, AVS, AVSL, SI Grilles

3/S3 STAIRCASE SWIRL DIFFUSERS IR, SDV, DSK. v 2.6 (en)

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x OUTLET x M6 x 20

ALUMINIUM CENTRIFUGAL FANS x M6 x x M6 x 16

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

AXO adjustable vanes swirl diffusers

VD1 CLC. Small Valves DIN-range with a higher k v -value

BNA Series. PLENUM FAN with Backward Wheels

variable flow dampers

Cabinets G " integrated in upright Handle strip in side panel Easy solution for shortened doors

ISO 5136 INTERNATIONAL STANDARD. Acoustics Determination of sound power radiated into a duct by fans and other air-moving devices In-duct method

Ventilating grilles, Ventilating valves

Use. Worth noting. Key figures. Installation. lindab fasadium

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

ALUMINIUM CENTRIFUGAL FANS. 4 x M6 x 16

ALUMINIUM CENTRIFUGAL FANS M20 4 x M5 x 10 INLET. 4 x M5 x 12

AX6 adjustable blades swirl diffusers

The OCTANORM system components set a new standard in shop design.

Air Handling Unit. Konvent

Più alto 3d flat»cc«datasheet

Method of Measuring Machinery Sound Within an Equipment Space

DCG adjustable core circular diffusers

Cam Roller Guides. The Drive and Control Company. Service Automation. Electric Drives and Controls. Linear Motion and Assembly Technologies

PET PETI PET/PETI. Supply air diffuser for ceilings

Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett.

Wöhler DP 700 Leakage Tester

zehnder stratos CS CS CS CSW CSW Product Overview Model Code (example)

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

Addendum to ARI Standard , Air Terminals September 2002

Transcription:

Technical Documentation Swirl Diffusers Series DLA Example: Type DLA 9 with rectangular box D - 70435 Stuttgart, Grenzstraße 7 +49 (711) 82 01-0, Fax +49 (711) 82 01-7 Internet: www.ltg-ag.de E-Mail: info@ltg-ag.de LTG Incorporated 5 Corporate Drive, Suite E Spartanburg S.C., 293 USA +1 (864) 599-63, Fax +1 (864) 599-6344 Internet: www.ltg-inc.net E-Mail: info@ltg-inc.net LTG S.r.l. con socio unico Via G. Leopardi I-066 Melzo +39(02)9550535,Fax+39(02)9550828 Internet: www.ltg-srl.com E-Mail:ltg@ltgsrl.191.it DLA-eng-TP (08/) 419-172

Swirl diffusers series DLA Content Page Application, installation/positioning, functionality, flow types, advantages 3 Product overview 4 Type DLA 7 5 Type DLA 8 6 Type DLA 9 7 Dimensions air distribution boxes 8 Selection diagrams type DLA 7 11 Selection diagrams type DLA 8 16 Selection diagrams type DLA 9 18 Installation 19 Nomenclature Notes Dimensions stated in this brochure are in mm. Dimensions stated in this brochure are subject to General Tolerances according to DIN ISO 2768-vL. Straightness and twist tolerances for extruded aluminum profiles according to DIN EN 1-2. You will find the actual tender documentations at the end of this document. They are available in word format at your local dealership or at www.ltg-ag.de. E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 2 of

Swirl diffusers series DLA Application Direct ventilation of occupied zones in commercial and industrial facilities which require high air exchange rates because of thermal loads, e.g. restaurants, shopping centers, laboratories. Installation/Positioning Integration in the ceiling or free suspension. Recommended installation height: 2.5... 5 meters. Functionality The highly inductive, fanned rotational flow makes it possible to handle high cooling loads and still maintain comfortable air conditions in the occupied zones. As the aerodynamic swirl disc is easily adjustable the patterns can be set to suit varying room conditions, even after installation. Thanks to the highly inductive effect as a result of the large number of individual air jets, the diffuser is suitable for both high flow rates and variable flow rate systems with low flow rates. Flow types The swirl disc can be set for two flow types: - tangential flow (basic version) -verticalflow. Advantages Highly inductive air diffuser with swirl characteristics. High comfort due to low air speeds and temperature differences in the occupied zone. Economical installation, thanks to - central fixing (up to size 6) - factory-set swirl disc, pattern may be modified at any time to meet new room conditions. Easy flow rate regulation thanks to integrated throttle valves as standard. Wide range of different design features. All metal construction - smooth surface - easy cleaning With rectangular, pyramid or cylindrical plenum box available. Connection box may be used in combination with a variety of LTG swirl diffusers. With tangential flow, the air jets will attach strongly to the ceiling resulting in a fully mixed turbulent flow structure in the room, with rapid temperature and velocity decay of the jet. With vertical flow, the air is projected conically downwards. The vertical flow is used preferably in the heating mode and in high rooms. Example for the installation of a swirl diffuser type DLA 7 E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 3 of

Swirl diffusers series DLA Product overview DLA 7 DLA 8 DLA 9 Primarily for use in convenience areas (e.g. offices, meeting rooms) Primarily for use in convenience areas with high flow rates (e. g. conference rooms, halls) Primarily for use in areas requiring high air exchange rates due to thermal load (e. g. shopping centers, restaurants, labs) Flow rate [m³/h] 0 to 900 500 to 00 0 to 00 Flow type Tangential All models All models All models Vertical All model All model Only models 600, 6 Model [mm] Square 0 500 600 6 800 --- --00 6 --00 500 600 6 --- Round 0 500 600 6 800 --- --00 6 --00 500 600 6 --- Diffuser plate Design Swirl disc Design Air supply box Form Material Flow restrictor Duct connection Lateral From above Basic version: visible side powder coated to RAL reference Special version (e. g. anodized, chrome-plated, stainless steel) on request Basic version: coated in black or white Special version (e. g. anodized, chrome-plated, stainless steel) on request Rectangular box, pyramid box, cylindrical box Galvanized sheet steel At round connection with adjustable flow restrictor, adjustment from below through the diffuser plate. Round spigot. For small box heights a side entry rectangular connection is available. Round spigot E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 4 of

Swirl diffusers type DLA 7 Views of unit Flow types Tangential setting 1and2 Swirl disc Diffuser plate Vertical setting Swirl disc Diffuser plate Type DLA 7 with rectangular box The swirl disc can be set for two flow types : the tangential flow 1 and 2, or vertical flow. With the tangential flow 1 (standard setting) the air jets will attach strongly to the ceiling resulting in a fully mixed turbulent flow structure in the room, with rapid temperature and velocity decay of the jet. Tangential setting 2 is preferably used for lower flow rates and large cooling differentials. The outlet cross-section is reduced, thus diffusing the air with increased momentum, ensuring that the jet remains powerfully attached to the ceiling. As a result, induction effect is increased. Type DLA 7 with pyramid box Flow development with tangential setting With the vertical setting, the air is projected conically downwards. The vertical flow is used preferably in the heating mode. Flow development with vertical setting E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 5 of

Swirl diffusers type DLA 8 Views of unit Flow types Swirl disc Diffuser plate Tangential flow Swirl disc Type DLA 8 with rectangular box Diffuser plate Vertical flow The swirl disc can be set for two flow types: the tangential flow or vertical flow. With the tangential flow (standard setting), the air jets will attach strongly to the ceiling resulting in a fully mixed turbulent flow structure in the room, with rapid temperature and velocity decay of the jet. Type DLA 8 with pyramid box Flow development with tangential setting With the vertical flow, the air is projected conically downwards. The vertical flow is used preferably in the heating mode. Flow development with vertical setting E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 6 of

Swirl diffusers type DLA 9 View of unit Flow types Tangential setting Swirl disc Diffuser plate Vertical setting Swirl disc Diffuser plate Type DLA 9 with rectangular box The swirl disc can be set for two flow types: the tangential flow or vertical flow (vertical flow only for models 600/6). With the tangential flow (standard setting), the air jets will attach strongly to the ceiling resulting in a fully mixed turbulent flow structure in the room, with rapid temperature and velocity decay of the jet. Flow development with tangential setting With the vertical setting, the air is projected conically downwards. The vertical flow is used preferably in the heating mode. Flow development with vertical setting (only models 600/6) E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 7 of

Swirl diffusers series DLA Dimensions air distribution box DLA with rectangular box and lateral connection for round supply ducts 9 Ø 8 j j B K 9 Ø 8 Model 0 500 600 6 800 Type 7, 9 7, 9 7, 8, 9 7, 8, 9 7 j A* 398 498 598** 623** 798 j B* 396 496 596 596 796 j K 366 466 566 566 766 H Ø d H 290 315 370 + 370 + 5 Ød 199 223 279 + 279 + 314 12 L 70 L 60 80 80 80 80 j A * Tolerance +1/-0,5 mm ** 595 respectively 6 for installation in grid ceiling [QE] + when Ø d = 249 and H = 3 DLA with rectangular box and connection from above for round supply ducts 9 Ø 8 j B Ø d L 9 Ø 8 Model 0 500 600 6 800 Type 7, 9 7, 9 7, 8, 9 7, 8, 9 7 j A* 398 498 598** 623** 798 j B* 396 496 596 596 796 j K 366 466 566 566 766 H H 242 242 242 242 242 12 Ød 199 223 279 279 314 j j K A L 60 80 80 80 80 * Tolerance +1/-0,5 mm ** 595 respectively 6 for installation in grid ceiling [QE] DLA with rectangular box and lateral connection for round supply ducts and adapter for round diffuser plate 9 Ø 8 j j B K 9 Ø 8 Model 0 500 600 6 800 Type 7, 9 7, 9 7, 8, 9 7, 8, 9 7 j A* 397 498 597 597 798 j B* 396 496 596 596 796 j K 366 466 566 566 766 Ø d H 352 377 432 + 432 + 467 H 12 L 70 ØC 376 476 576 576 776 ØD 398 498 598 623 798 83 Ød 199 223 279 + 279 + 314 Ø C j A Ø D L 60 80 80 80 80 * Tolerance +1/-0,5 mm + when Ø d = 249 and H = 2 E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 8 of

Swirl diffusers series DLA Dimensions air distribution box DLA with pyramid box and lateral connection for round supply ducts Model 0 500 600 6 800 Type 7, 9 7, 9 7, 8, 9 7, 8, 9 7 j A* 398 498 598** 623** 798 H bei Baugr. 600/6 53 F E ja Ød 12 C H C 2 283 3 3 472 Ød 199 223 279 G 279 G 279 G E 236 336 436 436 636 F 81 81 81 81 81 H 273 344 297*** 297*** 556 * Tolerance +1/-0,5 mm ** 595 respectively 6 for installation in grid ceiling [QE] G at DLA 8: Ø d = 314 *** box executed as pyramid stump DLA with pyramid box and lateral connection for round supply ducts and adapter for round diffuser plate Model 0 500 600 6 800 Type 7, 9 7, 9 7, 8, 9 7, 8, 9 7 H bei Baugr. 600/6 Ød 83 C H V A* 398 498 598 623 798 C 8 366 386 386 555 Ød 199 223 279 G 279 G 279 G ØD 399 499 599 624 799 E 236 336 436 436 636 F 81 81 81 81 81 124 F ja E ØD 12 H 345 416 368** 368** 628 * Tolerance +1/-0,5 mm G at DLA 8: Ø d = 314 Features ** box executed as pyramid stump - Minimum loss of energy on the surface. - Stacking boxes with a minimum transport volume. - Integrated flow restrictor, to be adjusted from below, through the diffuser. Delivery in closed position. - Diffuser plate is delivered separately. - Detached connecting piece enclosed. - Flexible hose connection. For insertion and removal of the box, simply tilt. No need to disconnect. - The pyramid boxes, models 0 to 6, are being fastened in the center. The air diffuser plate of model 800 is being fastened from the outside using 8 screws. E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 9 of

Swirl diffusers series DLA Dimensions air distribution box DLA with cylindrical box and lateral connection for round supply ducts 7,5 Ø9 (3x) ØB L () Model 0 500 600 6 800 Type 7, 9 7, 9 7, 8, 9 7, 8, 9 7 A* 398 498 598 623 798 H Ø d B 377 477 577 577 777 H 0 335 375 375 467 Ød 199 223 279 279 279 C L 60 60 60 12 ØA C 76 87 71 71 163 * Tolerance +1/-0,5 mm DLA with cylindrical box and connection from above for round supply ducts ØB 7,5 Ø d L Model 0 500 600 6 800 Type 7, 9 7, 9 7, 8, 9 7, 8, 9 7 A* 398 498 598 623 798 B 377 477 577 577 777 Ød 199 223 279 279 279 Ø9(3x) 237 L 46 66 66 66 66 * Tolerance +1/-0,5 mm ØA E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page of

Swirl diffusers type DLA 7 Selection diagram for DLA 7 with KLS, model 0, spigot 199 mm, tangential setting - 1 2 t[k] cmax [cm/s] a(c max )[m] 5 4 3 2 1,5 1 0.5 H> 4m H= 3.5m H= 3.. 2.75m exhaust with swirl disc + 8 db air mode 90_ without swirl disc - 12 db 0 150 35 45 50 0 0 0 350 0 500 Stated acoustics at tangential setting 1 V. 0 p [Pa] 0 80 60 50 15 8 6 m 3 /h Legend V = volume flow [m 3 /h] t zu = supply air temperature [ C] t RA = room air temperature [ C] Δt = temperature difference between supply air and room air [K] Δp = pressure loss [Pa] L WA = sound power level [db(a)] a(c max )= spread at which the maximum speed of the jet air has been measured [m] c max = maximum speed of jet air with uniformly distributed heat loads [cm/s] H = installation height [m] Note: The stated L WA -values are valid for the tangential setting 1. With the vertical setting, the level is 2 db lower, with the tangential setting 2 the level is 12 db higher. Model 0 recommended volume flow V [m 3 /h] 2 recomm. height of diffused air H [m] 2.5...5.0 recommended distance between two diffusers (distance to wall a/2) a [m] 3.0...3.5 Selection example see page 13 E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 11 of

Swirl diffusers type DLA 7 Selection diagram for DLA 7 with KLS, model 500, spigot 223 mm, tangential setting - 1 2 t[k] cmax [cm/s] a(c max )[m] 5 4 3 2 1,5 1 0.5 H> 4m H= 3.5m H= 3.. 2.75m 35 45 50 0 p [Pa] 0 80 60 50 15 8 6 exhaust with swirl disc + 3.5 db air mode 90_ with swirl disc - 15 db 150 0 0 0 350 0 500 600 V. stated acoustics at tangential setting 1 m 3 /h Legend V = volume flow [m 3 /h] t zu = supply air temperature [ C] t RA = room air temperature [ C] Δt = temperature difference between supply air and room air [K] Δp = pressure loss [Pa] L WA = sound power level [db(a)] a(c max )= spread at which the maximum speed of the jet air has been measured [m] c max = maximum speed of jet ai with uniformly distributed heat loads [cm/s] H = installation height [m] Note: The stated L WA -values are valid for the tangential setting 1. With the vertical setting, the level is 2 db lower, with the tangential setting 2 the level is 12 db higher. Model 500 recommended volume flow V [m 3 /h] 0 recomm. height of diffused air H [m] 2.5...5.0 recommended distance between two diffusers (distance to wall a/2) a [m] 3.0...3.5 Selection example see page 13 E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 12 of

Swirl diffusers type DLA 7 Selection diagram for DLA 7 with KLS, model 600/6, spigot 280 mm, tangential setting - 1 2 t[k] cmax [cm/s] a(c max )[m] 5 4 3 2 1,5 1 0.5 H> 4m H= 3.5m H= 3.. 2.75m 0 0 0 350 0 500 600 800 exhaust with diffusing element + 0 db air mode 90_ without diffusing element - 13 db Stated acoustics at tangential setting 1 35 45 V. 0 p [Pa] 0 80 60 50 15 8 6 5 4 m 3 /h Legend V = volume flow [m 3 /h] t zu = supply air temperature [ C] t RA = room air temperature [ C] Δt = temperature difference between supply air and room air [K] Δp = pressure loss [Pa] L WA = sound power level [db(a)] a(c max )= spread at which the maximum speed of the jet air has been measured [m] c max = maximum speed of jet air with uniformly distributed heat loads [cm/s] H = installation height [m] Selection example in the diagram DLA model 600/6: V zu = 500 m 3 /h Δp = 15 Pa L WA = 37 db(a) Δt = K a(c max ) 2.3 m c max 15 cm/s H = 2.75 m Note: The stated L WA -values are valid for the tangential setting 1. With the vertical setting, the level is 2 db lower, with the tangential setting 2 the level is 12 db higher. Model 600/6 recommended volume flow V [m 3 /h] 500 recomm. height of diffused air H [m] 2.5...5.0 recomm. distance between two diffusers (distance to wall a/2) a [m] 3.0...3.5 E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 13 of

Swirl diffusers type DLA 7 Selection diagram for DLA 7 with KLS, model 800, spigot 280 mm, tangential setting - 1 2 t[k] cmax [cm/s] a(c max )[m] 5 4 3 2 1,5 1 0.5 H> 4m H= 3.5m H= 3.. 2.75m exhaust with diffusing element + 5 db air mode 90_ without diffusing element - 5 db 35 45 2 0 0 0 3500 500 600 800 00 stated acoustics at tangential setting 1 V. m 3 /h 50 0 p [Pa] 0 80 50 15 8 6 4 Legend V = volume flow [m 3 /h] t zu = supply air temperature [ C] t RA = room air temperature [ C] Δt = temperature difference between supply air and room air [K] Δp = pressure loss [Pa] L WA = sound power level [db(a)] a(c max )= spread at which the maximum speed of the jet air has been measured [m] c max = maximum speed of jet air with uniformly distributed heat loads [cm/s] H = installation height [m] Note: The stated L WA -values are valid for the tangential setting 1. With the vertical setting, the level is 2 db lower, with the tangential setting 2 the level is 12 db higher. Model 800 recommended volume flow V [m 3 /h] 750 recomm. height of diffused air H [m] 2.5...5.0 recommended distance between two diffusers (distance to wall a/2) a [m] 3.0...3.5 Selection example see page 13 E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 14 of

Swirl diffusers type DLA 7 Selection diagram DLA 7 with KLS, rectang. box, model 800, spigot 315 mm, tangential setting - 1 2 t[k] cmax [cm/s] a(c max )[m] 5 4 3 2 1,5 1 0.5 H> 4m H= 3.5m H= 3.. 2.75m exhaust with diffusing element - 1 db air mode 90_ without diffusing element - 13 db 35 0 80 p [Pa] 50 8 2 0 0 350 0 500 600 800 00 V. stated acoustics at tangential setting 1 m 3 /h 45 50 15 6 4 Legend V = volume flow [m 3 /h] t zu = supply air temperature [ C] t RA = room air temperature [ C] Δt = temperature difference between supply air and room air [K] Δp = pressure loss [Pa] L WA = sound power level [db(a)] a(c max )= spread at which the maximum speed of the jet air has been measured [m] c max = maximum speed of jet air with uniformly distributed heat loads [cm/s] H = installation height [m] Note: The stated L WA -values are valid for the tangential setting 1. With the vertical setting, the level is 2 db lower, with the tangential setting 2 the level is 12 db higher. Model 800 recommended volume flow V [m 3 /h] 750 recomm. height of diffused air H [m] 2.5...5.0 recommended distance between two diffusers (distance to wall a/2) a [m] 3.0...3.5 Selection example see page 13 E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 15 of

Swirl diffusers type DLA 8 SelectiondiagramDLA8withKLS,pyramidbox,model600/6,spigot280mm, tangent.setting t[k] a(c max )[m] 5 cmax [cm/s] t[k] t[k] t[k] 4 3 2 1,5 1 0.5 H> 4m h= 1.7m H= 3.5m h= 1.7m H= 3.. 2.75m 35 45 0 80 p [Pa] 50 15 8 6 4 2 h= 1.7m exhaust with diffusing element + 4 db air mode 90_ without diffusing element - 2 db 0 0 0 350 0 500 600 800 00 V. stated acoustics are also valid fort vertical setting m 3 /h Legend V = volume flow [m 3 /h] t zu = supply air temperature [ C] t RA = room air temperature [ C] Δt = temperature difference between supply air and room air [K] Δp = pressure loss [Pa] L WA = sound power level [db(a)] a(c max )= spread at which the maximum speed of the jet air has been measured [m] c max = maximum speed of jet air with uniformly distributed heat loads [cm/s] H = installation height [m] Selection example in the diagram DLA model 600/6: V zu = 700 m 3 /h Δp = 12 Pa L WA = 33 db(a) Δt = -8 K a(c max ) 2.1 m c max 21 cm/s H = 2.75 m Model 600/6 recommended volume flow V [m 3 /h] 750 recomm. height of diffused air H [m] 2.75...5.0 recommended distance between two diffusers (distance to wall a/2) a [m] 2.0...3.0 E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 16 of

Swirl diffusers type DLA 8 SelectiondiagramDLA8withKLS,pyramidbox,model600/6,spigot315mm, tangent.setting t[k] a(c max )[m] 5 cmax [cm/s] t[k] t[k] t[k] 4 3 2 1,5 1 0.5 H> 4m h= 1.7m H= 3.5m h= 1.7m H= 3.. 2.75m 35 45 50 0 80 p [Pa] 50 15 8 6 4 2 h= 1.7m exhaust with diffusing element + 3 db air mode 90_ without diffusing element db 0 0 350 0 500 600 800 00 V. 1 m 3 /h stated acoustics are also valid fort vertical setting Legend V = volume flow [m 3 /h] t zu = supply air temperature [ C] t RA = room air temperature [ C] Δt = temperature difference between supply air and room air [K] Δp = pressure loss [Pa] L WA = sound power level [db(a)] a(c max )= spread at which the maximum speed of the jet air has been measured [m] c max = maximum speed of jet air with uniformly distributed heat loads [cm/s] H = installation height [m] Model 600/6 recommended volume flow V [m 3 /h] 750 recomm. height of diffused air H [m] 2.75...5.0 recommended distance between two diffusers (distance to wall a/2) a [m] 2.5...3.0 Selection example see page 16. E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 17 of

Swirl diffusers type DLA 9 Selection diagram DLA 9 with KLS Supply air Supply air Sound power level L wa [db(a)] 65 60 55 50 45 35 0 Flow rate [m 3 /h] Pressure loss Dp [Pa] 4 0 0 800 00 1800 0 Flow rate [m 3 /h] A-weighted sound power level type DLA 9 Pressure loss type DLA 9 80 0 0 800 00 1800 Model 0 Model 500 Model 600/6 Exhaust air with swirl disc Exhaust air with swirl disc 65 80 Sound power level L wa [db(a)] 60 55 50 45 35 0 0 0 800 00 1800 Pressure losst p [Pa] 4 0 0 0 800 00 1800 Flow rate [m 3 /h] Flow rate [m 3 /h] A-weighted sound power level type DLA 9 Pressure loss type DLA 9 Model 0 Model 500 Model 600/ 6 E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 18 of

Swirl diffusers series DLA Installation The LTG diffuser DLA can be installed flush to ceiling or covering the joints in intermediate ceilings or freely suspended on the existing suspension holes of the box. The diffuser plate is connected to the air supply box with screws. Installation flush to ceiling for intermediate ceilings, with lateral duct connection Free suspension above a grid ceiling E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page 19 of

Swirl diffusers series DLA Nomenclature DLA600/600/Q/D/9/PG90 / W / P / SR / KLS 280 / - Model DLA 7 0, 500, 600, 6, 800 DLA 8 600, 6 DLA 9 0, 500, 600, 6 Hole pattern Size 0, 500, 600/6 Form of diffuser plate square round square for inserting in grid ceiling Q R QE Swirl disc with D without Type 7 8 9 Surface of the diffuser plate powder coated similar RAL (state RAL No.) PG glossy (degree of gloss 70 % ± %) Basic version RAL 90, glossy (degree of gloss 70 % ± %) powder coated similar RAL (state RAL No.), PM mat (degree of gloss % ± %) Colour of swirl disc RAL 90, pure white, silk mat (basic version) W RAL 9011, graphite black, silk mat S powder coated similar RAL (state RAL number!) P Air distribution box rectangular box (basic version) Q pyramid box P cylindrical box Z without Connection lateral connection for round supply ducts SR connection from above for round supply ducts OR on request... Flow restrictor without with KLS DN 0 DN 2 DN 0 DN 280 DN 315 Accessories without Adapter for round diffuser plate, made of galvanized steel sheet A E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 DLA-eng-TP (08/) Printed in Germany Former editions are invalid Subject to technical modifications page of

Locations and Representatives Germany Central Office (Frankfurt) Sales area: PLZ 54, 55, 60, 63, 64, 66 9, 97 Sontraer Str. 27 D-60386 Frankfurt am Main Herr Bergmann +49 (69) 94 19-12, Fax - E-mail: Bergmann@LTG-AG.de Central Office (Herborn) Sales area:: PLZ, 31, 34-38, 56, 57, 61, 65 Sperberweg 16 D-35745 Herborn Herr Hartmann +49 (2772) 570-7, Fax -727 E-mail: Hartmann@LTG-AG.de Eastern Office (Berlin) Sales area:: PLZ -, 29, 39 Eisenhutweg 51a D-12487 Berlin Herr Linke +49 () 63 22 87-74, Fax -75 E-mail: Linke@LTG-AG.de Eastern Office (Chemnitz) Sales area:: PLZ 01-09, 98, 99 Johannes-Ebert-Straße D-09128 Chemnitz Herr Schenfeld +49 (371) 77118-01, Fax -02 E-mail: Schenfeld@LTG-AG.de Southern Office Sales area:: PLZ 70-96 Grenzstraße 7 D-70435 Stuttgart Herr Gau +49 (711) 81-9, Fax -2 E-mail: Gau@LTG-AG.de Sales area: PLZ 80 7, 90-96 Grenzstraße 7 D-70435 Stuttgart Herr Flaadt +49 (711) 81-752, Fax -2 E-Mail: Flaadt@LTG-AG.de Western Office Verkaufsgebiet: PLZ 26-28, 32, 33, - 53, 58-59 Baststraße D-46119 Oberhausen/Rheinl. Herr Perenz +49 (8) 431-55, Fax -56 E-mail: Perenz@LTG-AG.de Austria KTG Klimatechnische Gesellschaft mbh Schubertstraße 13 A-2126 Ladendorf +43 (75) 289, Fax (075) 222 E-Mail: office@ktg-wien.com Great Britain MAP Motorised Air Products Ltd. Unit 5A Sopwith Crescent Wickford Business Park Wickford GB-Essex SS11 8YU +44 (1268) 57 44 42, Fax +44 (1268) 57 44 43 E-Mail: info@mapuk.com Netherlands Opticlima Systems b.v. Leeuwerikstraat 1 NL-3853 AG Ermelo +31 (341) 493969, Fax +31 (341) 493931 E-Mail: info@opticlima.nl Poland HTK Went Sp.z.o.o. ul. Chopina 13/3 PL-047 Krakow +48 (12) 632 31 32, Fax +48 (12) 632 81 93 E-Mail: info@htk-went.pl Portugal ArGelo S. A. R. Luis Pastor de Macedo Lote 28 B, P-1750-158 Lisboa +351 (21) 752 01, Fax +351 (21) 752 01 29 E-Mail: info@argelo.pt Switzerland Laminair AG Kirchbergstrasse 5 CH-30 Burgdorf +41 (34) 4 02-, Fax +41 (34) 4 02-11 E-Mail: info@laminair.ch Turkey Step Müh. Yapi Ltd. Barbaros Mah. Kayacan Sokak No. TR-34746 Yenisahra-Atasehir-Istanbul +90 (216) 470 0070, Fax +90 (216) 470 05 E-Mail: info@stepyapi.com.tr The Program for Room Air Technology Key components Air diffusers for ceilings, walls and floors: LTG System clean, linear diffusers Coandatrol R, ceiling air diffusers Coandavent R, displacement air diffusers, swirl diffusers LTG chilled beam cool wave Induction units Klimavent R Fan coil units Raumluft Ceiling fan coil units Ventotel R Facade fan coil units Univent R Decentralized ventilation units Airflow control units labair system: Components for lab ventilation LTG Engineering Services Technical services for investors, architects, engineers and plant builders during design, construction and operation of buildings. Reliable and precise data relating to the ventilation of air conditioning system are given already before realization of the project, determined by measurements, calculations, building simulations and experiments. The Program for Process Air Technology Key components Axial, radial and tangential fans Fahrtwind Simulators LTG Filtration Technology: fans, suction nozzles, dampers, filters, separators, compactors LTG Humidification Technology: air humidifiers, product humidifiers LTG Engineering Services Technical services during development and operation of assembly groups, machines and plants Analysis, simulation, optimization Customized solutions Mobile filtration lab/ filter engineering on site E Grenzstraße 7 D-70435 Stuttgart +49 (711) 81-0 Fax -7 Internet: www.ltg-ag.de E-Mail: raumluft@ltg-ag.de Printed in Germany Former editions are invalid Subject to technical modifications.

Specification and Schedule of Prices Swirl Diffusers Type DLA 7 Edition 16.8. / page 1 of 2 Qty. Description Adjustable swirl diffuser for constant or variable flow rates. High induction ratio, optimum air guiding contour through swirl disc. Rapid reduction of expelled air speed and temperature difference. All-metal version. Models o 0 o 500 o 600 o 6 o 800 Hole pattern o 0 o 500 o 600/6 Diffuser comprising of: Diffuser plate made of galvanized steel sheet, o square [Q] visible side powder coated: o RAL 90 pure white glossy (basic version) [PG90], degree of gloss 70 % ± % Swirl disc o with built-in swirl disc for supply air [D], with an flow-optimized contour for turbulence-free and noiseless air guidance, factury-set, subsequently adjustable even after installation. powder coated o RAL 90 pure white silk mat (basic version) [W] o RAL 9011 graphite black silk mat [S] Air distribution box of galvanized steel sheet with suspension holes o rectangular box (basic version) [Q] Connection socket o lateral round (basic version) [SR] Flow restrictor o Flow restrictor [KLS], adjustable from below (basic version) Unit price in Total price in Manufacturer: Series: Swirl diffusers Type: DLA 7 Grenzstraße 7 D-70435 Stuttgart Tel.: +49 / 711 / 81-0 Fax.: +49 / 711 / 81-7 Internet: www.ltg-ag.de E-Mail: info@ltg-ag.de Former editions are invalid Subject to technical modifications

Specification and Schedule of Prices Swirl Diffusers Type DLA 7 Edition 16.8. / page 2 of 2 Qty. Special versions and accessories Description Diffuser plate o round [R] o square, for inserting in grid ceiling [QE] o special colour RAL o mat [PM.], degree of gloss % ± % Swirl disc o special colour RAL [P...] o without swirl disc [-] Air distribution box o pyramid box [P] o cylindrical box [Z] o without air distribution box [-] Connection socket o from above, round [OR] o on request [...] Flow restrictor o without flow restrictor [-] Adapter o Adapter for round diffuser plate [A] (for pyramid box and rectangular box), made of galvanized steel sheet, size: o 0 o 500 o 600 o 6 o 800 Unit price in Total price in Grenzstraße 7 D-70435 Stuttgart Tel.: +49 / 711 / 81-0 Fax.: +49 / 711 / 81-7 Internet: www.ltg-ag.de E-Mail: info@ltg-ag.de Former editions are invalid Subject to technical modifications

Specification and Schedule of Prices Swirl Diffusers Type DLA 8 Edition 16.8. / page 1 of 2 Qty. Description Adjustable swirl diffuser for constant or variable flow rates. High induction ratio, optimum air guiding contour through swirl disc. Rapid reduction of expelled air speed and temperature difference. All-metal version. Model o 600 o 6 Diffuser comprising of: Diffuser plate made of galvanized steel sheet, o square [Q] visible side powder coated: o RAL 90 pure white glossy (basic version) [PG90], degree of gloss 70 % ± % Swirl disc: o with built-in swirl disc for supply air [D], with an flow-optimized contour for turbulence-free and noiseless air guidance, factory-set, subsequently adjustable even after installation. powder coated o RAL 90 pure white silk mat (basic version) [W] o RAL 9011 graphite black silk mat [S] Air distribution box of galvanized steel sheet with suspension holes o rectangular box (basic version) [Q] Connection socket o lateral round (basic version) [SR] Flow restrictor o Flow restrictor [KLS], adjustable from below (basic version) Unit price in Total price in Manufacturer: Series: Swirl diffusers Type: DLA 8 Grenzstraße 7 D-70435 Stuttgart Tel.: +49 / 711 / 81-0 Fax.: +49 / 711 / 81-7 Internet: www.ltg-ag.de E-Mail: info@ltg-ag.de Former editions are invalid Subject to technical modifications

Specification and Schedule of Prices Swirl Diffusers Type DLA 8 Edition 16.8. / page 2 of 2 Qty. Special versions and accessories Description Diffuser plate o round [R] o square, for inserting in grid ceiling [QE] o special colour RAL o mat [PM.], degree of gloss % ± % Swirl disc o special colour RAL [P...] o without swirl disc [-] Air distribution box o pyramid box [P] o cylindrical box [Z] o without air distribution box [-] Connection socket o from above, round [OR] o on request [...] Flow restrictor o without flow restrictor [-] Adapter o Adapter for round diffuser plate [A] (for pyramid box and rectangular box), made of galvanized steel sheet, size: o 600 o 6 Unit price in Total price in Grenzstraße 7 D-70435 Stuttgart Tel.: +49 / 711 / 81-0 Fax.: +49 / 711 / 81-7 Internet: www.ltg-ag.de E-Mail: info@ltg-ag.de Former editions are invalid Subject to technical modifications

Specification and Schedule of Prices Swirl Diffuser Type DLA 9 Edition 16.8. / page 1 of 2 Qty. Description Adjustable swirl diffuser for constant or variable flow rates. High induction ratio, optimum air guiding contour through swirl disc. Rapid reduction of expelled air speed and temperature difference. All-metal version. Model o 0 o 500 o 600 o 6 Hole pattern o 0 o 500 o 600/6 Diffuser comprising of: Diffuser plate made of galvanized steel sheet, o square [Q] visible side powder coated: o RAL 90 pure white glossy (basic version) [PG90], degree of gloss 70 % ± % Swirl disc o with built-in swirl disc for supply air [D], with an flow-optimized contour for turbulence-free and noiseless air guidance, factory-set, subsequently adjustable even after installation. powder coated o RAL 90 pure white silk mat (basic version) [W] o RAL 9011 graphite black silk mat [S] Air distribution box of galvanized steel sheet with suspension bores: o rectangular box (basic version) [Q] Connection socket o lateral round (basic version) [SR] Flow restrictor o Flow restrictor [KLS], adjustable from below (basic version) Unit price in Total price in Manufacturer: Series: Swirl diffusers Type: DLA 9 Grenzstraße 7 D-70435 Stuttgart Tel.: +49 / 711 / 81-0 Fax.: +49 / 711 / 81-7 Internet: www.ltg-ag.de E-Mail: info@ltg-ag.de Former editions are invalid Subject to technical modifications

Specification and Schedule of Prices Swirl Diffuser Type DLA 9 Edition 16.8. / page 2 of 2 Qty. Special version and accessories: Description Diffuser plate o round [R] o square for inserting in grid ceiling [QE o special colour RAL o mat [PM.], degree of gloss % ± % Swirl disc o special colour RAL [P...] Air distribution box o pyramid box [P] o cylindrical box [Z] o without air distribution box [-] Connection socket o from above, round [OR] o on request [...] Flow restrictor o without flow restrictor [-] Adapter O Adapter for round diffuser plate [A] (for pyramid box and rectangular box), made of galvanized steel sheet, size: o 0 o 500 o 600 o 6 Unit price in Total price in Grenzstraße 7 D-70435 Stuttgart Tel.: +49 / 711 / 81-0 Fax.: +49 / 711 / 81-7 Internet: www.ltg-ag.de E-Mail: info@ltg-ag.de Former editions are invalid Subject to technical modifications