Identification of Penicillinase-Resistant Penicillins in Human Urine by RPLC Method

Similar documents
DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

Appendix II- Bioanalytical Method Development and Validation

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Received: ; Accepted:

Impact factor: 3.958/ICV: 4.10 ISSN:

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

Volume 6, Issue 2, January February 2011; Article-015

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

Chapter-4 EXPERIMENTAL WORK BY RP-HPLC

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article. Estimation of zaleplon by a new RP-HPLC method

Validation of Stability-Indicating RP-HPLC Method for the Assay of Ibrutinib in Pharmaceutical Dosage form

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

DEVELOPMENT AND VALIDATION OF NEW RP-HPLC METHOD FOR THE DETERMINATION OF AFLOQUALONE IN HUMAN PLASMA AND FORMULATION

Department of Quality Assurance, Luqman College of Pharmacy, GULBARGA (K.S.) INDIA ABSTRACT

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Research Article Available online at

SIMPLE AND SENSITIVE VALIDATED REVERSE PHASE HPLC-UV METHOD FOR THE DETERMINATION OF LYMECYCLINE IN PHARMACEUTICAL DOSAGE FORMS

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

HPLC Method Development and Validation for the estimation of Esomeprazole in Bulk and Pharmaceutical Dosage Form

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

Simultaneous estimation of ramipril and valsartan by RP-HPLC method in combined. dosage form

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

Journal of Drug Delivery and Therapeutics

Determination of Fexofenadine Hydrochloride in Pharmaceutical Dosage Form By Reverse Phase High Performance Liquid Chromatography Method

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

Dissolution study and method validation of alprazolam by high performance liquid chromatography method in pharmaceutical dosage form

METHOD DEVELOPMENT AND VALIDATION OF RALTEGRAVIR POTASSIUM AND RILPIVIRINE HCL BY HPLC AND HPTLC METHODS

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method

Chapter 4: Verification of compendial methods

DEVELOPMENT AND VALIDATION OF HPLC METHOD FOR THE ESTIMATION OF NICERGOLINE IN MARKETED FORMULATIONS

International Journal of Pharma and Bio Sciences V1(1)2010 UV- SPECTROPHOTOMETRIC DETERMINATION OF TENATOPRAZOLE FROM ITS BULK AND TABLETS

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

Journal of Chemical and Pharmaceutical Research, 2017, 9(1): Research Article

Validated First Order Derivative Spectroscopic Method for the determination of Stavudine in Bulk and Pharmaceutical Dosage Forms

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

Department of Chemistry, JNTUACE, Kalikiri

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

International Journal of Current Trends in Pharmaceutical Research. International Journal of Current Trends in Pharmaceutical Research

J Pharm Sci Bioscientific Res (4): ISSN NO

A Reverse Phase Liquid Chromatography Analysis of Citicoline Sodium in Pharmaceutical Dosage Form using Internal Standard Method

Revision Bulletin 27 Jan Feb 2017 Non-Botanical Dietary Supplements Compliance

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

International Journal of Pharma and Bio Sciences V1(1)2010. HPLC method for analysis of Lercanidipine Hydrochloride in Tablets

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

DEVELOPMENT AND VALIDATION OF A RP-HPLC METHOD FOR DETERMINATION OF LOPINAVIR IN BULK AND PHARMACEUTICAL DOSAGE FORM

B. Anupama et al. IRJP 2 (1)

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Revision Bulletin 29 Dec Jan 2018 Non-Botanical Dietary Supplements Compliance

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Research Article. Figure 1. Chemical structure of doxofylline. Indonesian J. Pharm. Vol. 24 No. 1 : ISSN-p :

Validation Aspect In Multicomponent Fraction From Gokshur (Tribulus terrestris Linn.) By RP- HPLC Method

RP-HPLC Method for Simultaneous Estimation of Atenolol, Hydrochlorothiazide and Losarton in Tablet Dosage form

Fast methods for the determination of ibuprofen in drug products

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

Pelagia Research Library

Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

ANALYTICAL METHOD PROCEDURES

Available online Research Article

Development and Validation of Stability Indicating Assay Method of Etodolac by using UV-Visible Spectrophotometer

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Introduction to Pharmaceutical Chemical Analysis

Journal of Advanced Scientific Research DEVELOPMENT AND VALIDATION OF STABILITY-INDICATING RP-HPLC METHOD FOR ESTIMATION OF DABIGATRAN ETEXILATE

Simultaneous estimation of meclizine and nicotinic acid by using RP-HPLC

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

*Author for Correspondence

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 9(1), 35-42

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

Development and Validation of a HPLC Method for Chlorphenamine Maleate Related Substances in Multicomponents Syrups and Tablets

Method development and validation of Tinidazole and Ciprofloxacin HCl in bulk and tablet dosage form by Rp-HPLC

International Journal of Research and Reviews in Pharmacy and Applied science.

Relative Response Factor for Lamivudine and Zidovudine Related substances by RP-HPLC with DAD detection

Asian Journal of Research in Chemistry and Pharmaceutical Sciences Journal home page:

Journal of Chemical and Pharmaceutical Research

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

ORIENTAL JOURNAL OF CHEMISTRY An International Open Free Access, Peer Reviewed Research Journal.

Radhakrishnan K. et al. / International Journal of Pharmacy & Therapeutics, 3(1), 2012, e- ISSN Print ISSN

PHARMA SCIENCE MONITOR

SIMULTANEOUS ESTIMATION OF CILOSTAZOL AND ASPIRIN IN SYNTHETIC MIXTURE USING HPTLC METHOD

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

Transcription:

OPEN ACCESS Eurasian Journal of Analytical Chemistry ISSN: 1306-3057 2017 12(1):3-13 DOI 10.12973/ejac.2017.00140a Identification of Penicillinase-Resistant Penicillins in Human Urine by RPLC Method Zehra Üstün Süleyman Demirel University, TURKEY Ebru Çubuk Demiralay Süleyman Demirel University, TURKEY İkbal Demet Nane Süleyman Demirel University, TURKEY Received 16 June 2016 Revised 15 October 2016 Accepted 19 October 2016 ABSTRACT In this study, the combined effect of the organic modifier content and mobile phase ph has been used to predict the chromatographic behavior of methicillin, oxacillin, nafcillin, cloxacilin and dicloxacillin. The optimum separation condition of these drugs in acetonitrilewater binary mixture was determined from the mobile phase ph dependence of their retention factor. A Synergy Fusion-RP C 18 analytical column (150 mm x 4.6 mm I.D., 4 µm) was preferred to carry out the developed method. Chromatographic measurements were done at 30 C with an eluent flow rate of 1 ml min -1. In order to validate the optimized conditions, these drugs were applied successfully in spiked samples of human urine. Valsartan was chosen as an internal standard. The described method was linear over a concentration range of 2-32 µg ml -1 and 3-48 µg ml -1 for the assay of methicillin, nafcillin, dicloxacillin and oxacillin, cloxacillin respectively. Good linear relationships over the investigated concentration ranges were observed with values of correlation coefficient higher than 0.999 for all of the drugs. The intra-day and inter-day precisions of this method were evaluated with RSD (%) values less than 0,561 and 1,622%, respectively. Optimized assay method was validated according to United States Pharmacopeia (USP) guidelines to confirm linearity, accuracy and precision. Keywords: combined effect, penicillinase-resistant penicillins, method validation, internal standard, human urine INTRODUCTION Penicillins are one of the oldest and most important group of antibiotics widely used for the treatment of infections. The penicillinase resistant penicillins (second generation penicillins) are semisyntheic modifications of natural penicillins that are resistant to bacterial enzyme betalactamase. Their basic structure includes a nucleus consisting of a beta-lactam ring and a side chain. Due to the wide application of this drug family in both human and veterinary Authors. Terms and conditions of Creative Commons Attribution 4.0 International (CC BY 4.0) apply. Correspondence: Ebru Çubuk Demiralay, Department of Chemistry, Faculty of Science and Literature, Süleyman Demirel University, 32260 Isparta, Turkey. ebrucubukdemiralay@gmail.com

Z. Üstün et al. Figure 1. Chemical structures of investigated compounds medicine, the analysis of pharmaceutical formulations as well as biological fluids for monitoring its bioavailability, pharmacokinetic profile and efficiency is of utmost importance. The basic structure of penicillin is a thiazolidine ring attached to a β-lactam ring. Five members of this class of antibiotics are determined in the present study: Oxacillin, methicillin, nafcillin, dicloxacillin and cloxacillin (Figure 1) [1-2]. Reversed phase liquid chromatography (RPLC) has been the most important branch of high performance liquid chromatography. In RPLC method, the most important aim of the optimization studies is to find the best chromatographic separation conditions. There are several approaches to predict the retention behavior of an ionisable solute as a function of chromatographic conditions. Because of the ionization properties of these types of solutes, the factors generally selected to optimize the chromatographic separation are the ph of the mobile phase and the percentage of the organic solvent of the eluent [3-9]. The effect of these parameters on the chromatographic behavior is somewhat more complex since the variation of organic modifier and analyze these compounds. Knowledge of the state of ionization of acids is essential in RPLC separations in order to explain changes in retention, peak shape or overloading behaviour of acids. Solute ionization can be estimated from dissociation constant values (pk a). RPLC technique is used to method development and in the understanding of the physicochemical phenomena acidbase species. The knowledge of the pk a values of the species is crucial in predicting the influence of ph on retention and selectivity in LC [4]. Thus, a knowledge of the dissociation 4

Eurasian J Anal Chem constants of the compounds in hydroorganic solvent mixtures can help to advance the analytical method [8]. A search of the literature revealed that a number of reversed phase liquid chromatography (RPLC) method have been developed to determine the individual or several drugs in dosage forms [10] or in biological fluids [11-16]. Nevertheless, no report has been published on the optimization using the combined effect of organic modifier concentration and ph of the mobile phase to separate oxacillin, methicillin, nafcillin, dicloxacillin and cloxacillin. In this work, the experimental region was selected such a way that the retention factors (k) of the penicillins would stay within the limits 1 < k < 10. RPLC technique has been applied to the simultaneous determination of these antibiotics in human urine. No method for the simultaneous determination of these drugs has been found in the literature. EXPERIMENTAL Chemicals and reagents All the chemicals used in this study were analytical reagent grade and HPLC grade. Analyte drugs were purchased from Sigma (USA). Acetonitrile (used as organic modifier) and sodium hydroxide (used in ph adjustment) were obtained from Merck (Darmstadt, Germany). Ortho-phosphoric acid used as buffer component of mobile phase was purchased from Riedelde Haen (Riedel-de Haen, Germany). Apparatus The chromatographic equipment used consisted on a Shimadzu HPLC system (Shimadzu Technologies, Kyoto, Japan) equipped with a pump (LC-20AD), a UV Visible detector (SPD-20A), a column oven (CTO-20A) and a degasser system (DGU-20A 3). Synergy Fusion-RP C18 analytical column (150 mm x 4.6 mm I.D., 4 µm) was used as stationary phase (Phenomenex, USA). In order to measure the ph values of the eluents, a Mettler Toledo MA 235 ph/ ion analyser (Schwerzenbach, Switzerland) was chosen. For the standardization of potentiometric system according to the IUPAC rules [17], potassium hydrogen phthalate (0.05 mol kg -1 ) was used. Chromatographic procedure Throughout this study, mobile phase assayed was acetonitrile-water at 40% (v/v), to determine the chromatographic behavior of these compounds. The ph of the mobile phase containing 30 mm o-phosphoric acid was adjusted between 2.5 and 7.0 by the addition of 1M sodium hydroxide. Chromatographic measurements were done at 30 C with an eluent flow rate of 1 ml min -1. The volume of solution injected into the column was 20 μl for each run. The studied compounds had different optimal wavelengths (for methicillin, oxacillin, cloxacillin, dicloxacillin, valsartan (I.S.) 210 nm, nafcillin 228 nm). For each compound, the 5

Z. Üstün et al. retention time values, t R, were determined from three different injections. Retention factors were calculated from k = (t R-t 0)/t 0. Separation factor (α) was calculated from k values of two adjacent peaks (α = k 2/k 1). Preparation of standard solutions In LC analysis, studied compounds were prepared carefully at a concentration of 100 μg ml -1 by dissolving it in the mobile phase. All the subsequent dilutions for working standards were prepared with the mobile phase. Sodium hydroxide solution used in ph adjustment was prepared by dilution in water. All stock solutions were stored at 4 C. Preparation of urine calibration standards Calibration standards were prepared by spiking urine with the appropriate amount of stock solutions. Different stock solutions were used to prepare calibration standards. Calibration curves were constructed by analyzing a serials of blank human urine, spiked with methicillin, nafcillin, dicloxacillin and oxacillin, cloxacillin at the concentration 2.0, 4.0, 8.0, 16.0, 24.0, 32.0 μg ml -1 and 3.0, 6.0, 12.0, 24.0, 36.0, 48.0 μg ml -1, respectively. The concentration of I.S. was maintained at a constant level of 0.8 μg ml -1. Separate standard calibration graphs were constructed for each component by plotting the ratio of the peak area of the drug to that of I.S. against the drug concentration. Preparation of the urine samples were carried out as described under preparation procedure. Preparation of human urine samples The urine sample was diluted 20-fold in deionized water in order to avoid matrix effect. 2 ml diluted urine was transferred to a 110 x 30 mm plastic tube and 3 ml acetonitrile was added to the tube. Stocks of human drug-free urine from healthy volunteers were spiked with different amounts of methicillin, oxacillin, nafcillin, cloxacillin, dicloxacillin. To 5 ml of the urine sample, 160 μl of internal standard (valsartan, 0.8 μg ml -1 ) and different concentrations of studied compounds were added and the solution vortexed. Samples of 10 ml urine were spiked for final concentrations of 8 and 16 μg ml -1 for methicillin, nafcillin, dicloxacillin and 12 and 24 μg ml -1 for oxacillin, cloxacillin, respectively. The spiked samples were microfiltered through a 0.45 μm filter. A 20 μl volume of each sample was injected into the HPLC system. Recovery studies from human urine samples To keep an additional check on the accuracy of this developed method, recovery experiments were performed by adding the known amount of pure drug to pre-analyzed samples of human urine sample. Known amounts of the pure drug and a constant level of an internal standard were added to human urine sample and the mixtures were analyzed. The percent recovery was calculated by comparing the concentration obtained from spiked samples with the actual added concentration. After five repeated experiments, the average recovery percentage of these compounds was calculated for each compound. 6

Eurasian J Anal Chem Figure 2. The effect of the mobile phase ph on retention factor values (40%, v/v) of acetonitrile: ( ), methicillin; ( ), nafcillin; ( ), oxacillin; ( ), cloxacillin; ( ), dicloxacillin. The theoretical results are indicated as continuous lines and the plotted points are experimental results RESULTS AND DISCUSSION In this study, the retention behaviors of methicillin, oxacillin, cloxacillin, dicloxacillin and nafcillin were investigated using the combined effect of ph and organic modifier concentration of the eluent. The retention of compounds in reversed phase chromatography depends significantly on the degree of ionization of these compounds and thus on the ph of the mobile phase. In this study, retention behavior of these compounds as a function of the ph of th mobile phase at a given mobile phase composition has been investigated. The dependence of the retention factors of the compounds on ph value in the mobile phase (40 %, v/v) is given in Figure 2. It is noteworthy that better retention versus ph is obtained using the hydroorganic ph values. The optimization of chromatographic selectivity can be achived by taking into account the ionization constant and retention factors of the ionized and non-ionized forms of the compounds for organic solvent-water binary mixture systems. Synergi Fusion-RP C18 reversed phase HPLC column (150 mm x 4.6 mm I.D., 4 µm) yielded greatly improved efficiencies for studied compounds. In this study, the efficiency, selectivity and retention terms were calculated and summarized in Table 1 for optimum separation condition. It can be 7

Z. Üstün et al. Table 1. The retention, selectivity and separation factor values for penicillinase-resistant penicillins at 40% at ph 3.5 Compounds k 2 α k 2 /k 2 + 1 α 1 + α (1/4) N R s Oxacillin/methicillin 2.882 2.405 0.742 0.584 24.533 10.640 Cloxacillin/oxacillin 3.950 1.370 0.798 0.270 26.273 5.665 Nafcillin/cloxacillin 4.563 1.155 0.820 0.134 23.731 2.614 Dicloxacillin/nafcillin 6.283 1.377 0.863 0.274 28.062 6.629 Valsartan(I.S.)/dicloxacillin 8.120 1.292 0.890 0.226 28.368 5.714 Table 2. System suitability parameters for investigated compounds Parameters Observed value Methicillin Oxacillin Cloxacillin Nafcillin Dicloxacillin Valsartan (I.S.) Recommended value Retention time 3.527 6.235 7.952 8.938 11.705 14.659 - Tailing factor 1.135 1.097 1.078 1.028 1.059 1.054 2 Retention factor (k) 1.196 2.883 3.951 4.566 6.289 8.128 >1 Resolution factor (Rs) - 10.509 5.608 2.597 6.590 5.689 >2 Theoretical plates (N) 4708 9366 10803 8859 12436 12755 >2000 Selectivity factor (α) - 2.410 1.371 1.155 1.377 1.292 >1 RSD% (for retention time) 0.093 0.046 0.057 0.069 0.079 0.090 1 RSD% (for peak area) 0.429 0.404 0.223 0.253 0.516 0.887 1 achieved when the acetonitrile content in the mobile phase is 40% (v/v) at ph 3.5, in which all solutes are well separated in an analysis time of about 15 min. System suitability test is used to verify that the resolution and reproducibility of the chromatographic system are adequate for the analysis to be done. According to US Pharmacopoeia 24th, method <621> [18], system suitability test is an integral part of a liquid chromatographic method. System suitability test was performed by five replicate injections of studied compounds. The results from system suitability test are presented in Table 2 for each drug. Using the described analytical method, an optimal resolution of the analytes was achieved. A typical chromatogram is shown in Figure 3. These examined drugs were all well separated in a total duration of 15 min, with good peak resolutions, sharpness and symmetry. Calibration graphs were constructed for all compounds. The calibration curves (ratio of peak areas of drug to that of internal standard versus concentration) were linear in human urine in concentration range of 2-32 and 3-48 μg ml -1 for methicillin, nafcillin, dicloxacillin and oxacillin, cloxacillin, respectively. The correlation coefficient was always greater than 0.999. Table 3 lists the calibration curve parameters such as, slope, intercept correlation coefficients, detection limit (LOD) and quantitation limit (LOQ) values. 8

Eurasian J Anal Chem Figure 3. Optimized chromatogram of standard mixture. 1, methicillin (16,67 μg ml -1 ); 2, oxacillin (16,67 μg ml -1 ); 3, cloxacillin (16,67 μg ml -1 ); 4, nafcillin (16,67 μg ml -1 ); 5, dicloxacillin (16,67 μg ml -1 ); 6, valsartan (I.S.) (16,67 μgml -1 ). Experimental conditions as in chromatographic procedure Table 3. Statistical evaluation of the calibration data of studied compounds by RPLC Sample Linearity range (μg ml -1 ) Slope Intercept S.E. of slope S.E. of intercept Correl. coeff. Detection limit (μg ml -1 ) Quantitation limit (μg ml -1 ) Methicillin 2-32 0.457-0.066 0.003 0.054 0.999 0.647 1.962 Oxacillin 3-48 0.400-0.060 0.002 0.042 0.999 0.509 1.541 Cloxacillin 3-48 0.494-0.105 0.003 0.080 0.999 0.789 2.391 Nafcillin 2-32 0.787-0.116 0.003 0.059 0.999 0.363 1.100 Dicloxacillin 2-32 0.560-0.065 0.004 0.062 0.999 0.543 1.646 The drug-free human urine, spiked with different concentrations of investigated compounds, were used for precision studies. The precision of the method was estimated by both interday and intraday reproducibilities. The intraday reproducibility was determined by replicate injections. The interday reproducibility of the method was determined by five repeated analysis of samples over three different days. It was found that the relative standard deviations (RSD) calculated from the peak area ratios of each drug versus the I.S. for determinations, both interday and intraday, were all less than 1.70% for the five drugs (Table 4). The accuracy of the method for the analysis of urine samples was determined by recovery experiments. Control urine samples were spiked with two different concentrations of methicillin, nafcillin, dicloxacillin, oxacillin and cloxacillin. The recoveries and relative standard deviations (RSD) were calculated after five replicate analyses are given in Table 5. 9

Z. Üstün et al. Table 4. Intra-Day and Inter-Day precision of studied compounds Compounds Methicillin Oxacillin Cloxacillin Nafcillin Dicloxacillin Theoretical Concentration (μg ml -1 ) Intra-Day measured Concentration Mean (μg ml -1 ) RSD % Inter-Day measured Concentration Mean (μg ml -1 ) RSD % 4 4.072 0.525 4.126 1.622 16 16.048 0.286 16.068 0.452 6 6.078 0.432 6.193 0.690 24 23.911 0.390 24.209 0.935 6 6.054 0.252 6.310 1.531 24 24.131 0.561 24.024 0.761 4 4.057 0.376 4.040 0.666 16 16.077 0.353 16.246 1.170 4 4.018 0.433 4.052 0.806 16 16.061 0.431 16.342 0.976 Table 5. Accuracy and precision of the method for HPLC analysis of investigated compounds in human urine Compounds Methicillin Oxacillin Cloxacillin Nafcillin Dicloxacillin Amount added ( μg ml -1 ) Mean found concentration ( μg ml -1 ) Recovery (% mean confidence interval) Standard deviation RSD (%) 8 7.980 99.746 ± 1.915 0.772 0.774 16 16.063 100.391 ± 1.050 0.423 0.421 12 12.066 100.554 ± 1.799 0.725 0.721 24 24.209 100.870 ± 1.912 0.770 0.763 12 12.061 100.508 ± 1.773 0.714 0.711 24 23.942 99.760 ± 1.258 0.507 0.508 8 7.991 99.887± 0.893 0.360 0.360 16 16.047 100.292 ± 0.527 0.212 0.212 8 7.950 99.373 ± 1.094 0.441 0.443 16 16.132 100.828 ± 0.963 0.388 0.385 Figure 4 shows (1) the chromatogram obtained for blank urine in the optimised experimental conditions and (2) the chromatogram obtained for urine spiked with different concentrations of studied compounds. As a R S 1.5-2.0 is generally accepted as a good resolution between the peak and the closest electing potential interference, these results show that the peaks for five penicillins were resolved from the other components of this biological fluid. 10 CONCLUSION This work represents the first study dealing with the simultaneous chromatographic determination of Penicillinase-resistant penicillins fixed acetonitrile percentage. In this study, the experimental model of combined ph/organic modifier was successfully applied to

Eurasian J Anal Chem Figure 4. Typical chromatograms for blank human urine (A), human urine spiked with methicillin, dicloxacillin, nafcillin at 8 μg ml -1, oxacillin, cloxacillin at 12 μg ml -1 and valsartan at 0.8 μg ml -1 (B) describe the retention factors in different ph and fixed organic modifier condition. A sensitive and effective RPLC method was developed for the simultaneous determination of methicillin, nafcillin, dicloxacillin, oxacillin and cloxacillin in human urine by reversed phase highperformance liquid chromatography with ultraviolet detection. The method was validated showing satisfactory data for all the method validation parameters tested. Validation of the method for the quantification of these compounds in urine showed that the method had high sensitivity and accuracy with μg.ml -1 level measurement. The good validation criteria results of the method allowed its use in the quantification of these compounds. ACKNOWLEDGEMENTS This work was supported by Research Project Coordination Unit of Suleyman Demirel University (Project 3303-YL2-12). 11

Z. Üstün et al. REFERENCES 1. Samanidou, V. F., Evaggelopoulou, E. N., Papadoyannis, I. N. (2006). Development of a validated HPLC method for the determination of four penicillin antibiotics in pharmaceuticals and human biological fluids. Journal of Separation Science, 29, 1550-1560. 2. Samanidou, V. F, Giannakis, E. D., Papadaki, A. (2009). Development and validation of an HPLC method for the determination of seven penicillin antibiotics in veterinary drugs and bovine blood plasma. Journal of Separation Science, 32, 1302-1311. 3. Demiralay, E. Ç., Üstün, Z., Daldal, Y. D. (2014). Estimation of thermodynamic acidity constants of some penicillinase-resistant penicillins. Journal of Pharmaceutical and Biomedical Analysis 91, 7-11. 4. Demiralay, E. Ç., Koç, D., Daldal, Y. D., Çakır, C. (2012). Determination of chromatographic and spectrophotometric dissociation constants of some beta lactam antibiotics. Journal of Pharmaceutical and Biomedical Analysis, 71, 139-143. 5. Berges, R., Sanz-Nebot, V., Barbosa, J. (2000). Modelling retention in liquid chromatography as a function of solvent composition and ph of the mobile phase. Journal of Chromatography A, 869, 27-39. 6. Pous-Torres, S., Torres-Lapasio, J. R., Baeza Baeza, J. J., Garcia Alvarez-Coque, M. C. (2007). Combined effect of solvent content, temperature and ph on the chromatographic behaviour of ionisable compound. Journal of Chromatography A, 1163(1-2), 49-62. 7. Roses, M., Subirats, X., Bosch, E. (2009). Retention Models for ionizable compounds in reversed phase liquid chromatography. Effect of variation of mobile phase composition and temperature. Journal of Chromatography A, 1216, 1756-1775. 8. Sanz-Nebot, V., Toro, I., Barbosa, J. (2001). Prediction of retention behaviour and evaluation of pka values of peptides and quinolones in liquid Chromatography. Journal of Chromatography A, 933, 45-56. 9. Secilmis-Canbay, H., Demiralay, E. Ç., Alsancak, G., Özkan, S. A. (2012). The Combined Effect of the Organic Modifier Content and ph of the Mobile Phase on the Chromatographic Behavior of Some Arylpropionic and Arylacetic Acids to Optimize Their Liquid Chromatographic Determinations. Chromatographia, 75, 711-720. 10. Barot T. G, Patidar K, Kshartri N, Vyas N (2009) Development and validation of L. C method for the determination of ampicillin and dicloxacillin in pharmaceutical formulation using an experimental design. E-Journal of Chemistry, 6, 955-964. 11. Al-Majed, A., Belal, F., Khalil, N. Y., Ibrahim, K. E. E. (2005). Stability indicating HPLC method for the determination of methicillin in vials and biological fluids with fluorometric detection. Journal of Liquid Chromatography & Related Technologies, 28, 1737-1750. 12. Cámara, M., Gallego-Picó, A., Garcinuño, R. M., Fernández-Hernando, P., Durand- Alegría, J. S., Sánchez, P. J. (2013). An HPLC-DAD method for the simultaneous determination of nine - lactam antibiotics in ewe milk. Food Chemistry, 141, 829-834. 13. Espinosa-Mansilla, A., Muñoz de la Peña, A., Gómez, D. G., Cañada-Cañada, F. (2006). HPLC determination of ciprofloxacin, cloxacillin, and ibuprofen drugs in human urine samples. Journal of Separation Science, 29, 1969-1976. 14. McWhinney, B. C., Wallis, S. C., Hillister, T., Roberts, J. A., Lipman, J., Ungerer, J. P. J. (2010). Analysis of 12 beta-lactam antibiotics in human plasma by HPLC with ultraviolet detection. Journal of Chromatography B, 878, 2039-2043. 15. Perez, B., Prats, C., Castells, E., Arboix, M. (1997). Determination of cloxacillin in milk and blood of dairy cows by high-performance liquid chromatography. Journal of Chromatography B, 698, 155-160. 12

Eurasian J Anal Chem 16. Sørensen, L. K., Rasmussen, B. M., Boison, J. O., Keng, L. (1997). Simultaneous determination of six penicillins in cows raw milk by a multiresidue high-performance liquid chromatographic method. Journal of Chromatography B, 694, 383-391. 17. Rondinini, S., Mussini, P. R., Mussini, T. (1987). Reference value standard and primary standard for ph measurements in organic solvents and water organic solvent mixtures of moderate to high permittivities. Pure Applied Chemistry, 59, 1549-1560. 18. Mc Nally, R. (2000). The United States Pharmacopoeia, 24th revision, Taunton, M. A. http://iserjournals.com/journals/ejac 13