DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

Similar documents
STRESS ANALYSIS USING BREMSSTRAHLUNG RADIATION

Application of positrons in materials research

Positron Annihilation Spectroscopy - A non-destructive method for material testing -

Study of semiconductors with positrons. Outlook:

New Concept of EPOS Progress of the Mono-energetic Positron Beam (MePS) Gamma-induced Positron Spectroscopy (GiPS)

Basics and Means of Positron Annihilation

Research Center Dresden Rossendorf

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Outlook: Application of Positron Annihilation for defects investigations in thin films. Introduction to Positron Annihilation Methods

The intense, pulsed positron source EPOS at the Research Centre Dresden-Rossendorf

Introduction into Positron Annihilation

ELECTRIC FIELD INFLUENCE ON EMISSION OF CHARACTERISTIC X-RAY FROM Al 2 O 3 TARGETS BOMBARDED BY SLOW Xe + IONS

POSITRON AND POSITRONIUM INTERACTIONS WITH CONDENSED MATTER. Paul Coleman University of Bath

ABNORMAL X-RAY EMISSION FROM INSULATORS BOMBARDED WITH LOW ENERGY IONS

Technical Status Update on PA Lifetime Spectroscopy Experiments and Results

Positron Annihilation in Material Research

PRINCIPLES OF POSITRON ANNIHILATION

APEX CARE INSTITUTE FOR PG - TRB, SLET AND NET IN PHYSICS

Identification of Getter Defects in high-energy self-implanted Silicon at Rp/2

Motivation. g-spectroscopy deals with g-ray detection and is one of the most relevant methods to investigate excited states in nuclei.

Positron Annihilation techniques for material defect studies

MCSHAPE: A MONTE CARLO CODE FOR SIMULATION OF POLARIZED PHOTON TRANSPORT

Positron-Electron Annihilation

in Si by means of Positron Annihilation

Positron Annihilation Spectroscopy

The EPOS System (ELBE Positron Source) at Helmholtz Centre Dresden- Rossendorf and first experiments at photovoltaic CIGS layers

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Slow-Positron-Beam Techniques

AEROSOL FILTER ANALYSIS USING POLARIZED OPTICS EDXRF WITH THIN FILM FP METHOD

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES

CHAPTER-II Experimental Techniques and Data Analysis (Positron annihilation spectroscopy)

Positron theoretical prediction

Radiation Physics PHYS /251. Prof. Gocha Khelashvili

Material Science using Positron Annihilation

R. Krause-Rehberg. Martin-Luther-Universität Halle-Wittenberg. Positron Lifetime / Doppler Broadening / Angular Correlation / AMOC

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

Vacancy generation during Cu diffusion in GaAs M. Elsayed PhD. Student

SLOW-POSITRON IMPLANTATION SPECTROSCOPY IN NANOSCIENCE *

Nuclear Physics. (PHY-231) Dr C. M. Cormack. Nuclear Physics This Lecture

Nuclear Spectroscopy: Radioactivity and Half Life

DETECTORS. I. Charged Particle Detectors

GAMMA RAY SPECTROSCOPY

FUNDAMENTAL PARAMETER METHOD USING SCATTERING X-RAYS IN X-RAY FLUORESCENCE ANALYSIS

Nuclear Physics and Astrophysics

EEE4106Z Radiation Interactions & Detection

Time-Resolved μ-xrf and Elemental Mapping of Biological Materials

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE

ANALYSIS OF LOW MASS ABSORPTION MATERIALS USING GLANCING INCIDENCE X-RAY DIFFRACTION

RADIOACTIVE SAMPLE EFFECTS ON EDXRF SPECTRA

Nuclear Physics and Astrophysics

Nuclear Decays. Alpha Decay

on basis of the Geant4 simulations

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Interaction of Ionizing Radiation with Matter

LAB 4: Gamma-ray coincidence spectrometry (2018)

Nuclear Photonics: Basic facts, opportunities, and limitations

CHAPTER 12 TEST REVIEW

Laboratory of Nuclear Solid State Physics, USTC

Radiation Quantities and Units

Interaction of ion beams with matter

Gamma ray coincidence and angular correlation

INFLUENCE OF GROWTH INTERRUPTION ON THE FORMATION OF SOLID-STATE INTERFACES

FUNDAMENTAL PARAMETERS ANALYSIS OF ROHS ELEMENTS IN PLASTICS

Positron and positronium for the GBAR experiment

Positron program at the Idaho Accelerator Center. Giulio Stancari Idaho State University and Jefferson Lab

The Ones That Got Away: Neutron Leakage Spectra

Investigation of SiC by Positrons

The interaction of radiation with matter

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

Chapter Four (Interaction of Radiation with Matter)

DEVIL PHYSICS THE BADDEST CLASS ON CAMPUS IB PHYSICS

USABILITY OF PORTABLE X-RAY SPECTROMETER FOR DISCRIMINATION OF VALENCE STATES


in2p , version 1-28 Nov 2008

β and γ decays, Radiation Therapies and Diagnostic, Fusion and Fission Final Exam Surveys New material Example of β-decay Beta decay Y + e # Y'+e +

Alpha Decay. Decay alpha particles are monoenergetic. Nuclides with A>150 are unstable against alpha decay. E α = Q (1-4/A)

ISU Physics: Overview

IMPROVING THE ACCURACY OF RIETVELD-DERIVED LATTICE PARAMETERS BY AN ORDER OF MAGNITUDE

Alpha-Energies of different sources with Multi Channel Analyzer

Nuclear reactions in stars, and how we measure their reaction rates in the lab.

positron source EPOS - general concept - timing system - digital lifetime measurement

Chapter NP-4. Nuclear Physics. Particle Behavior/ Gamma Interactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 IONIZATION

Department of Physics, Techno India Batanagar (Techno India Group), Kolkata , West Bengal, India.

ASPECTS OF THE MCMASTER INTENSE POSITRON BEAM FACILITY

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

Extreme Light Infrastructure - Nuclear Physics ELI - NP

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

English CPH E-Book Theory of CPH Section 2 Experimental Foundation of CPH Theory Hossein Javadi

Physics 102: Lecture 26. X-rays. Make sure your grade book entries are correct. Physics 102: Lecture 26, Slide 1

Improvement of depth resolution of VEPAS by a sputtering technique

Conclusion. 109m Ag isomer showed that there is no such broadening. Because one can hardly

RADIOCHEMICAL METHODS OF ANALYSIS

THE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA

Positron Annihilation Spectroscopy on Defects in Semiconductors

A COMPACT X-RAY SPECTROMETER WITH MULTI-CAPILLARY X-RAY LENS AND FLAT CRYSTALS

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

Gamma-ray decay. Introduction to Nuclear Science. Simon Fraser University Spring NUCS 342 March 7, 2011

CHARACTERIZING PROCESS SEMICONDUCTOR THIN FILMS WITH A CONFOCAL MICRO X-RAY FLUORESCENCE MICROSCOPE

Transcription:

Copyright JCPDS - International Centre for Diffraction Data 2004, Advances in X-ray Analysis, Volume 47. 59 DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS F. A. Selim, D.P. Wells, J. F. Harmon and J. R. Williams Idaho State University, Idaho Accelerator Center, Campus Box 8263, Pocatello, ID 83209 ABSTRACT The recent development of Accelerator-based Gamma-induced Positron Annihilation Spectroscopy (AGPAS) has shown the possibility of probing residual stress in thick materials by Doppler broadening measurements [1]. In those measurements, the residual stresses were reflected in the line shape parameters of the 511 kev annihilation peak. However, since positron lifetime spectroscopy is a powerful tool to distinguish between different types of defects, such as dislocations and vacancy clusters [2], it is crucial to enable positron lifetime measurements in AGPAS. In this work, a new method is developed to conduct positron lifetime measurements on thick engineering materials using accelerators. By focusing 1.5 MeV protons from a Van de Graff accelerator on a thin Al window, coincident γ-rays of 2.8 MeV and 1.78 MeV are induced through (p,γ) reactions. The 1.78 MeV quantum provides a start signal for the positron lifetime spectrometer, where as the 2.8 MeV quantum bombards the material under investigation. This, in turn, creates a positron, which annihilates with one of the material electrons emitting two 511 kev photons. The stop signal for the positron lifetime is provided by the detection of one of the two 511 kev photons. The measured positron lifetime spectrum depends on the electron densities and hence provides information about the size of open volume defects. The method enables positron lifetime measurements in thick engineering materials up to tens of gm/cm 2, a thickness not accessible by conventional positron lifetime spectroscopy. INTRODUCTION Positron annihilation spectroscopy (PAS) has been known as a valuable tool to characterize materials and study defects [2]. Positron spectroscopy of defects can be performed by means of Doppler broadening spectroscopy of annihilation radiation, angular correlation of annihilation radiation (ACAR) measurements or positron lifetime spectroscopy (PLS). Positron annihilation measurements have been often performed using kev positrons from radioactive sources or positron beams. The range of kev positrons in materials are in the order of few hundred micrometers and hence the depths in materials that can be investigated by positrons are limited to this range. Consequently standard PAS is not able to study defects in thick materials. Accelerator based γ-ray induced positron annihilation spectroscopy (AG-PAS) [1, 3] is a recently developed technique that conducts positron annihilation spectroscopy by using MeV γ-rays from accelerators instead of using positrons. This technique combines the

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

Copyright JCPDS - International Centre for Diffraction Data 2004, Advances in X-ray Analysis, Volume 47. 60 high penetrability of MeV γ-rays with the high sensitivity of positrons to defects to provide a highly penetrating sensitive probe. Hence it extends positron spectroscopy of defects to thick materials and a wide variety of new applications. The first measurements of AG-PAS were conducted using bremsstrahlung radiation from a 6 MeV electron Linac to perform Doppler spectroscopy of positron annihilation. In those measurements residual stresses in engineering materials are reflected in the narrowing of the Doppler broadening of the 511 kev peak and in an increase of the annihilation fraction with valence electrons. Residual stresses due to tensile test were measured in low alloy steel [3] and Zr-4 [1]. Residual stresses due to cold work were also investigated in EP-823 and SS-304 [4]. The objective of this work is to develop a method to perform positron lifetime spectroscopy in AG-PAS. The importance of PLS lies in its unique ability to distinguish between different kinds of open volume defects and identify the defect size and its concentration in a single measurement. In the following, the basis of positron lifetime spectroscopy as a method for defect characterization will be demonstrated. Then the positron lifetime spectrometer in AG-PAS will be described. CHARACTERIZATION OF DEFECTS BY PLS Positron lifetime is the time that a positron spends in a material once it enters until it annihilates with an electron. The annihilation rate λ, which is the reciprocal of the positron lifetime, is given by [5]: 1 2 2 λ = = π r o c ψ () r n( r) γ dr τ, where τ is the positron lifetime, r o is the classical electron radius, c is the speed of light, r is the position vector, ψ(r) is the positron wave function, n(r) is the electron density and γ is the enhancement factor representing the increase in electron density due to the coulomb interaction between an electron and a positron. Since the positron lifetime is a function of the electron density at the annihilation site, it provides information about the electron densities and consequently open-volume defects in materials. Standard PLS in bulk materials is performed by using a Na-22 source, which emits a 1.72 MeV γ-quantum coincident with each positron. The positron lifetime is measured as the time difference between the detection of the 1.27 MeV photon and one of the two 0.511 MeV photons emitted from the positron annihilation event in the material. The measured positron lifetime spectrum is a convolution of the resolution function of the spectrometer and the positron decay curve in material. In a defect-free metal or semiconductor, all positrons annihilate as free particles from Bloch states with well-defined annihilation rate. This produces a single exponential decay and only one lifetime component exists in the lifetime spectrum. Open volume defects in materials form trapping centers for positrons. This is because a positron is strongly repelled by the nuclei in the lattice due to its positive charge. The absence of a positive charge at a defect site provides an attractive potential that traps positrons at this site.

Copyright JCPDS - International Centre for Diffraction Data 2004, Advances in X-ray Analysis, Volume 47. 61 Positron trapping at defect sites leads to longer positron lifetime because of the lower electron density at defect sites compared to regions without defects. With the presence of open volume defects, positrons annihilate from different states, each gives a characteristic lifetime τ i. The resulting positron lifetime spectrum N (t) consists of multi-time components: k = + 1 I i t N( t) exp i = 1 τ i τ i, where: k+1 the number of time components in the spectrum relating to the k number of defect types in the specimen and one time component from positron annihilation in bulk material, τ i is each individual lifetime and I i its intensity in the spectrum. The measured lifetime spectrum can be fitted by a sum of exponential decay components convoluted with the resolution function of the spectrometer. Each lifetime component and its intensity could be extracted from the fit. The lifetime value is related to the defect size and its characteristics, whereas the relative intensity for each lifetime component determines the defect concentration. POSITRON LIFETIME SPECTROSCOPY IN AG-PAS AG-PAS utilizes MeV γ-rays to implant positrons inside the material via pair production. The induced positrons thermalize and then annihilate with the material electrons emitting 511 kev annihilation photons. Lifetime spectroscopy in AG-PAS can be performed by using bremsstrahlung radiation from a short-pulsed electron linac. The pulse width should be in the order of picoseconds since positron lifetimes are in the range of few hundred picoseconds in most of the materials. This type of electron Linac is not widely available. Coincident MeV γ-rays represents another method to perform positron lifetime measurements in AG-PAS. Proton capture in some low atomic number materials such as Al-27 and C-13 induce coincident MeV γ-rays. One γ-quantum can be used to indicate the positron birth where as the other γ-quantum penetrates the specimen under investigation creating a positron. One of the two 0.511 MeV photons emitted from the positron annihilation event indicates the positron death. Proton capture in Al-27 forms Si-28 in high-energy excited states [6]. Subsequent transitions to the ground states induce coincident MeV γ-quanta. Figure 1 shows the energy levels of Si-28 nuclei due to (p, γ) reactions in Al-27. Both 2.8 and 3.2 MeV γ- quanta are emitted due to transitions from high-energy excited states to the first excited state, which decays to the ground state in 475 fs emitting a 1.78 MeV γ-quantum. This 27 Al (p,γ) 28 Si reaction has a strong resonance at 992 kev proton energy [7]. To obtain these coincident γ s we focused 1.5 MeV protons from a Van De Graff accelerator on thin Al window mounted at the end of the proton beam line. The 1.78 MeV photon

Copyright JCPDS - International Centre for Diffraction Data 2004, Advances in X-ray Analysis, Volume 47. 62 Figure1. Energy levels in 28 Si due to proton capture in 27 Al. emitted from the Al window provides a start signal for the positron lifetime spectrometer whereas the other γ-quantum (mostly the 2.8 MeV photon) penetrates the specimen generating a positron inside it. The induced positron annihilates with one of the material electrons emitting two 511 kev photons. The detection of the one of the 511 kev photons provides a stop signal for the spectrometer. Two BaF 2 detectors coupled to fast photo-multiplier tubes are used to record the start and stop signals. Figure 2 shows a fast-slow coincidence system to collect the positron lifetime spectrum, where the time measurement is performed in a fast channel and the energy selection is performed in a slow channel. An energy window was adjusted at 1.78 MeV for the start signal and another energy window was adjusted at 0.511 MeV for the stop signal. The coincidence between the high-energy 1.78 γ-quanta and the 0.511 MeV γ-quanta sharply reduces the random background in the spectrum. The timing resolution of the spectrometer was measured using a Co-60 source, which emits two coincident γ s of 1.17 and 1.33 MeV, and found to be 210 ps. Figure 2. Fast slow coincidence system for PLS based on proton capture induced coincident MeV γ-rays

Copyright JCPDS - International Centre for Diffraction Data 2004, Advances in X-ray Analysis, Volume 47. 63 Using this spectrometer, we measured the positron lifetime in pure thick materials of Pb, Al and Cu. Both Al and Cu were annealed before the measurements to get rid of any defects. Pb was not annealed because it is a self-annealing material. The measured positron lifetimes were: 194 ± 2 ps for Pb, 162 ± 3 ps for Al and 114 ± 5 ps for Cu. These lifetime values are in complete agreement with the published positron lifetime values experimentally and theoretically, giving us a complete confidence in the performance of the new positron lifetime spectrometer. More details about the positron lifetime spectra can be found elsewhere [8]. The presented technique extends PLS to thick materials because of the high penetration of γ-rays. In addition it has additional advantages over standard PLS because it yields lifetime spectra with single exponential positron decay from the pure defect free metals and semiconductors with no other lifetime components. One of the biggest problems of standard PLS is that the measured spectrum always contains unwanted lifetime components from positron annihilation in the source materials and from surface effects. CONCLUSION: We upgraded AG-PAS technique by a new method to perform positron lifetime spectroscopy based on using proton capture induced coincident MeV γ-rays. This approach extends PLS to thick materials and eliminates some of the associated problems with standard PLS technique. The importance of PLS lies in its ability to identify different kinds of defects in material and determine their concentration in a single measurement. ACKNOWLEDGEMENTS This work has been supported by Inland Northwest Research Alliance under contract ISU001. REFERENCES [1] F. A. Selim et al., Stress Analysis Using Bremsstrahlung Radiation, accepted to be published in Advances in X-ray Analysis, Vol. 46, proceedings of the 51 Denver X- ray Conference, 2002 [2] P. Hautojarvi and A. Vehanen, in: Positrons in Solids, Ed: P.Hautojarvi, 1979, p.1 [3] F.A. Selim et al., Nucl. Inst. & Meth. B 192 (2002), p. 197 [4] F. A. Selim, D. P. Wells, J. F. Harmon, J. Kwofie, A. K. Roy, Applications of Electron Linacs in Stress and Defect Measurements, accepted to be published in proceedings of ANS meeting in Accelerators Applications in Nuclear Renaissance, 2003 [5] R M. Nieminen, M. J. Manninen, in: Positrons in Solids, Ed: P.Hautojarvi, 1979, p.145 [6] M. Kenney, J. Bird and E. Clayton, Nucl. Inst. &Meth.168, 1980, p. 115 [7] R. Bondelied and C. Kennedy, Phys. Rev. 115 (1959), p. 1601 [8] F. A. Selim, D. P. Wells and J. F. Harmon, submitted to Phys. Rev. Lett. (2003)