Schools Analyst Competition

Similar documents
Schools Analyst Competition

HHPS WHMIS. Rules MSDS Hazard Codes Systems. Biology based. Chemistry based. Safety Symbols. Safety in the Lab. Lab Equipment

Plant Indicators for Acids and Bases

Safety in the Chemistry Laboratory

Advanced Unit 7: Chemistry Practical Examination (SET A) Candidates must have: Scientific calculator Ruler

2.8-1 SCIENCE EXPERIMENTS ON FILE Revised Edition. Dew Formation

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters)

Newton s Second Law of Motion

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

Objective: Science Classroom Laboratory Safety

Preparation of an Ester Acetylsalicylic Acid (Aspirin)

Lab 1: Safety Lab; Introduction to Volumetric and Weighing Techniques

Oxygen Demand, Chemical

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Topic Students devise an experiment to determine the types of bonds in three compounds.

17 th Chemistry Olympiad of the Baltic States

Experiment 7. Determining the Rate Law and Activation Energy for the Reaction of Crystal Violet with Hydroxide Ion

Substances and Mixtures:Separating a Mixture into Its Components

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

Completion Match each each piece of equipment with its description. Please only put one number in the blank.

The Synthesis and Analysis of Aspirin

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

CIE Chemistry A-Level Practicals for Papers 3 and 5

PART I: MEASURING MASS

GCE Chemistry PSA12: A2 Inorganic Chemistry Prepare an inorganic complex

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

TITRATION STAKES 2018 INSTRUCTIONS TO TEAM MEMBERS

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Sample Lab Manual Green Introductory Chemistry

Science Safety Booklet

Part II. Cu(OH)2(s) CuO(s)

Experiment 8 Introduction to Volumetric Techniques I. Objectives

C.S.Rye: Mascot Murder Mystery

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

Measuring Enthalpy Changes

Investigating Transition Metal Complexes

Determination of Orthophosphate Ion

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

Scientific Notation and Scaled Models

Determination of Orthophosphate Ion

EnAlgae SOP sheet: Silicate - SFA. 1. Purpose This procedure is to analyse seawater and freshwater for silicate, SiO2.

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution

Analyzing Hydrogen Peroxide Solution Chemistry 30

Core practical 5: Investigate the oxidation of ethanol

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Oxygen Demand, Chemical

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

INTRODUCTION TO ACIDS, BASES AND TITRATION

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Hazard Communication & Chemical Safety. Based on OSHA Standard

Determining the Concentration of a Solution: Beer s Law

Chemical Reactions: The Copper Cycle

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

General Rules. Be alert and responsible at all times in the laboratory.

This protocol is a modified version of the DuBois assay (DuBois et al. 1956) for the quantification of total carbohydrate content of a sample.

Sample Preparation LCW 909. Total Kjeldahl Nitrogen, TKN NB: NEW! LCW 909 GB

Experiment 7A ANALYSIS OF BRASS

#09 Investigating the Relationship between the Mass of a Liquid and its Volume Ken Lyle, St. John s School, Houston, TX

4.5 The iodoform test. Task. How can methanol be distinguished from ethanol? (2) Science - Chemistry - Organic Chemistry - 4 Alcohols (P )

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

UNIT 01 LAB SAFETY & EQUIPMENT

Chemical Bonds. MATERIALS 24-well microplate calcium chloride candle citric acid conductivity tester ethanol gloves iron ring lab apron

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Lab Safety Rules GENERAL GUIDELINES. 1. Conduct yourself in a responsible manner at all times in the laboratory.

Experiment 13I THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

HYSICAL AND CHEMICAL PROPERTIES AND PHYSIC AND CHEMICAL CHANGES

Spectrophotometric Determination of an Equilibrium Constant

Core practical 6: Investigating chlorination of 2-methylpropan-2-ol

To use calorimetry results to calculate the specific heat of an unknown metal. To determine heat of reaction ( H) from calorimetry measurements.

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

CHEM 200 Chapter 2 General Work Practices

7-A. Inquiry INVESTIGATION. 322 MHR Unit 3 Quantities in Chemical Reactions. Skill Check. Safety Precautions

Introduction to Spectroscopy: Analysis of Copper Ore

CHEMISTRY 130 General Chemistry I OXIDATION-REDUCTION CHEMISTRY

CHEMISTRY 135 General Chemistry II. Determination of an Equilibrium Constant

8 Enthalpy of Reaction

Read the lab thoroughly. Answer the pre-lab questions that appear at the end of this lab exercise.

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

Density of an Unknown

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

Electrolysis SCIENCE TOPICS PROCESS SKILLS VOCABULARY

EXPERIMENT 20. Solutions INTRODUCTION

DETERMINATION OF CHEMICAL OXYGEN DEMAND COD

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

13. Determining the value of K c for an equilibrium reaction Student Sheet

26. The preparation and purification of N-phenylethanamide Student Sheet

Separation and Qualitative Determination of Cations

EXPERIMENT 6 Empirical Formula of a Compound

Simple Battery. Alessandro Volta ( ) A replica of the first battery, built by Volta, can be created and used to understand electricity.

Cl 2(g) + NaCl + H 2 O. light. 2Cl. Once formed, the chlorine radical can react with the heptane as shown below: + Cl

RSC/AD Western Region. Schools Analyst Competition. Bristol

STOICHIOMETRY AND THE CHEMICAL REACTION

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Unit 1: Safety in the Laboratory

Transcription:

Royal Society of Chemistry Analytical Division North West Region Schools Analyst Competition 5 th May 2017 Experimental Handbook

SCHOOLS ANALYST COMPETITION 2017 The Scenario An unnamed man, 75, who lived alone has been found dead in an armchair late one afternoon at his home. He was visited by his GP early that morning and found to be in excellent health so foul play cannot be ruled out. A half-empty bottle of potassium chloride solution lay on the floor. It could have accidentally fallen from the bag of his GP that morning. It is of concern because potassium ions which will affect the sodium / potassium balance can cause the heart to stop beating by interfering with nerve impulses. Indeed, cardiac surgeons have used potassium chloride to temporarily stop the heart during operations. Also in the room are a couple of empty whisky glasses, thought to be left from a late morning visit by a friend of the deceased. The detective inspector who is in charge of the investigation, has arranged for a sample of urine to be taken and you as forensic analysts, are asked to determine the ethanol and potassium concentrations in the urine*; You have access to data on normal and abnormal levels for potassium and alcohol below so that you can advise on the likely cause of death. You will be provided with the necessary laboratory equipment, and a method which you must use to measure the alcohol and potassium content. At the end of the experiment your results will be assessed by the judges and they will select the winner on the basis of Accuracy, Precision and also the standard of your laboratory technique and data presentation. The true value for the alcohol and potassium ion the sample has been worked out using the same method by department s staff, and your aim is to get as close as possible to this value. Ethanol in urine Urine should be zero if no alcohol has been ingested. The threshold for drink driving in England, Wales and Northern Ireland is 1.07mg/ml. Levels greater than 3-4mg/ml can be fatal due to respiratory depression. Potassium in urine The standard reference range of potassium in an adult human should be between 136.5mg/l and 198.9mg/l *due to hygiene and safety the sample given is not urine but a spiked coloured water sample made up by the department s staff to match the original urine sample

THEORY The ethanol analysis is based upon the oxidation of ethanol by potassium dichromate (orange) under acidic conditions to produce acetaldehyde, (see reaction 1 below). The dichromate then oxidizes the acetaldehyde to acetic acid, (see reaction 2). As the dichromate oxidizes the various reactants, it is in turn reduced to Cr 3+ which is green. The green colour is the result of a characteristic absorbance of light at a wavelength in the region of 600nm. Reaction 1 3CH3CH2OH + K2Cr2O7 + 4H2SO4 3CH3CHO + Cr2(SO4)3 + K2SO4 + 7H2O Reaction 2 3CH3CHO + K2Cr2O7 + 4H2SO4 3CH3CO2H + Cr2(SO4)3 + K2SO4 + 4H2O The intensity of the green colour is measured using a spectrophotometer. The absorbance is directly proportional to the concentration of Cr 3+ in the solution (The Beer-Lambert law). The concentration of Cr 3+ is also proportional to the concentration of ethanol in the original sample. Measurements are made for a series of standard solutions containing a known concentration of ethanol and a graph is plotted of absorption against concentration. This graph, known as a calibration curve, can then be used to calculate the concentration of ethanol in an unknown sample. Because the urine sample will also contain other organic material, such as sugars, it is necessary to separate the ethanol by distillation prior to carrying out the oxidation. If this were not done the result would be higher than it should due to oxidation of these interfering compounds. Dr Tom Parry Jones OBE, an eminent Welsh entrepreneur and inventor, developed the world's first Electronic Breathalyser based on dichromate in 1974 and established Lion Laboratories to manufacture and market the products worldwide. It has since been replaced by more sophisticated electrochemical devices. For determining the potassium concentration you will make up a series of standards and then run these along with the unknown sample on the Atomic Absorption Spectrometer (AAS). Atomic absorption uses a high temperature flame to vaporize the sample and measures the amount of light absorbed at a wavelength unique to the element of interest. In comparison to spectrophotometry which measures the absorbance of light by an Iron containing molecule, Atomic Absorbance spectroscopy measures the absorbance of light by Iron atoms. The greater the amount of light absorbed, the higher the concentration.

HEALTH AND SAFETY It is essential that you read the following risk assessment, and are fully aware of the hazards associated with the materials you are using. Hazard Risk Control Measures First aid in case of accident Acidified Potassium Dichromate solution Highly corrosive, Oxidizing agent, Causes burns to skin and eyes. Toxic by ingestion. Very small quantities (1ml) issued in cuvettes. Substance must not be removed from the cuvette. Gloves, apron, and Safety glasses to be worn at all times In case of contact with skin or eyes Rinse the affected area with cold water immediately for at least 5 minutes. Report the incident to a member of staff. Obtain medical advice 0.25% Ethanol solution Harmful by ingestion, may cause dizziness and disorientation in excessive quantities. Serious long term chronic effects target organs Liver, Kidneys, Heart and Brain. Small quantities issued (250ml) to each group. In case of contact with skin or eyes Rinse the affected area with cold water Report the incident to a member of staff. Unknown urine Harmful by ingestion, Serious Issue of small quantities In case of contact with samples long term chronic effects. closely supervised by staff. skin or eyes Rinse the Target organs Liver, Kidneys, affected area with cold Heart and Brain water Report the incident to a member of staff Boiling water Burns caused by spillage, Eye protection worn and Wash affected area splashes or contact with liquid tongs used to handle hot under cold water and or steam items. supervision and seek first aid assistance assistance of trained staff at immediately all times. Solutions should be allowed to cool before handling. Glassware Glassware breakage causing All glassware is pre-checked Contact a member of cuts by technical staff and any staff and obtain first aid damaged equipment should assistance immediately be returned. Care to be in the case of an exercised especially when accident pushing rubber pipette fillers on to glass.

GENERAL LABORATORY SAFETY Pay careful attention to the safety advice that will be given to you prior to working in the lab. Familiarize yourself with the location of emergency exits. Eating, drinking or smoking is not permitted in the lab and mobile telephones must be switched off. Whilst working in the lab you must only touch chemicals and equipment that are used in your experiment. Do not run or fool around. You must report any accidents or incidents, however small, immediately to a member of staff. Please ask one of the demonstrators or technicians if you have any questions.

CHEMICALS AND EQUIPMENT Each team will be provided with; EQUIPMENT bulb pipettes (10ml, 20ml, 25ml, 50ml) pipette fillers Beakers (100ml x 2, 600ml x 1) Graduated pipettes (25ml, 10ml, 5ml) Measuring cylinder (25ml) 100ml round bottom flask and distillation apparatus (still head, condenser etc) Heating mantle or hotplate Small cork ring to support round bottom flask Stopper for 100ml round bottom flask 100ml volumetric flask (x7) with stopper Test tubes (x 9) and rack Small funnel Pasteur Pipettes and teat Graph paper, ruler, pencil Tongs Plastic 1cm cuvettes (x 9) in a rack Marker pen (medium) Boiling chips CHEMICALS Urine sample (safe to handle) Ethanol solution (2.5 mg/ml) Potassium stock solution (1000 µg/ml) Acidified potassium dichromate solution CARE! Deionized water (in wash bottle) EXPERIMENTAL PROCEDURE A Ethanol determination 1 Distillation Transfer using a bulb pipette 25 ml of the unknown sample into a 100 ml round bottom flask and add 25 ml water and a boiling chip. Place the flask in a heating mantle and assemble a distillation apparatus (Please ask the technical staff for help you will not lose any points). Ensure that the water is flowing within the condenser and heat the flask. Collect approximately 25 ml of distillate in a graduated beaker. Do not allow the heated flask to dry out. (Tip: Whilst waiting for the distillation to finish you may wish to prepare the standards as detailed in section 2, the water bath (see section 3) can be prepared to save time later also the potassium determination can be started.) Transfer the distillate to a 100 ml volumetric flask and rinse the beaker several times with small amounts of deionised water, pouring the rinses into the volumetric flask. Make the volume up to the 100 ml mark with deionised water. Stopper the flask and invert it several times to mix the contents

2 - Preparation of the standards and sample Label nine test tubes as described in the table below. You are provided with a standard 2.5 mg/ml solution of ethanol. In each test tube prepare the following solutions using a graduated pipette. Test tube ml of deionized water ml of 2.5 mg/ml ethanol Resulting mg/ml ethanol blank 2.50 0.00 0.00 Standard 1 2.00 0.50 0.5 Standard 2 1.50 1.00 1.0 Standard 3 1.00 1.50 1.5 Standard 4 0.50 2.00 2.0 Standard 5 0.00 2.50 2.5 Sample (reading 1) Sample (reading 2) Sample (reading 3) Each of these three tubes will contain 2.5ml of your sample distillate only. Three replicate measurements can then be made 3 Oxidation of the sample and standards Prepare a water bath by adding about 200ml of tap water to a 600ml beaker and place the beaker on a hotplate in one of the fume cupboards. Heat the water to a gentle boil. Warning: Acid dichromate solution is highly corrosive and an oxidizing agent. Gloves and eye protection must be worn and the following operation must be performed in a fume cupboard using extreme caution. Add 2.5 ml of acid dichromate solution to each of your nine test tubes. Place the test tubes into the water bath and once boiling re-commences heat the test tubes for 15 minutes. Remove the test tubes using tongs and allow them to cool to room temperature. Using a Pasteur Pipette carefully transfer enough solution from each tube to two thirds fill a disposable plastic cuvette. Note the position in the rack of each cuvette to avoid confusion. DO NOT WRITE ON THE CUVETTES!

4 Measurement of absorbance Take your cuvettes containing the standards and samples to the spectrophotometer and with the assistance of a demonstrator measure the absorbance of each cuvette at a wavelength of 590 nm. Record your results. The blank should be placed in the reference beam of the spectrophotometer. After recording your absorbances, pour the dichromate solutions into the labeled waste bottle. Do NOT pour down the sink! 5 Treatment of results You may now use the data that you have obtained to plot a graph of the absorbance against the concentration of each standard. You can then use the graph to read the concentration of ethanol in your sample. Remember that you initially took 25ml of the urine sample and diluted the ethanol obtained to a total volume of 100ml. You will need take this into account when calculating the ethanol concentration in the urine by multiplying the result by 2. EXPERIMENTAL PROCEDURE B Potassium determination You are provided with a stock solution containing 1000mg/l of potassium. Use the following method to make a range of standards to generate a calibration curve: In a 100ml volumetric flask dilute the following up to the mark using deionised water: Stock solution (ml) Concentration (mg/l) 10 100 20 200 30 300 40 400 50 500 With what s left in the unknown sample bottle and your standards you will be taken down to the 1 st floor research laboratory with a demonstrator and be shown how to run your samples on the AAS instrument, please take a book with you and note down the values so you can generate a calibration graph and work out the concentration of potassium in the sample.

RESULTS SHEET ETHANOL DETERMINATION (to be handed in with your graph) NAME OF SCHOOL SAMPLE ABSORBANCE CONCENTRATION (mg/ml) Standard 1 0.5 Standard 2 1.0 Standard 3 1.5 Standard 4 2.0 Standard 5 2.5 Sample (reading 1) Sample (reading 2) Sample (reading 3) Average absorbance for three replicates Concentration of ethanol in unknown mg/ml Concentration of ethanol in urine sample* mg/ml * Remember to multiply your answer by two to account for the dilution factor

RESULTS SHEET POTASSIUM DETERMINATION (to be handed in with your graph) SAMPLE ABSORBANCE CONCENTRATION (mg/l) Standard 1 100 Standard 2 200 Standard 3 300 Standard 4 400 Standard 5 500 Sample (reading 1) Sample (reading 2) Sample (reading 3) Average absorbance for three replicates mg/l Concentration of Potassium in unknown Given your findings what would you suggest contributed to the death? When you have completed your results sheet please hand it to the judges with your calibration graph FOR JUDGES USE ONLY Accuracy (Actual value Measured mean value) / Actual Value Precision (spread of replicate values) Graph presentation Laboratory technique (Observed during experiment)