Plasma Interface Element2

Similar documents
Sample Analysis Design. Solution Mode

Interface (backside) & Extraction Lens

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Spectrometric Methods of Analysis. OCN 633 Fall 2013

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

PRINCIPLE OF ICP- AES

ELEMENT2 High Resolution- ICP-MS INSTRUMENT OVERVIEW

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

- A spark is passed through the Argon in the presence of the RF field of the coil to initiate the plasma

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Debjani Banerjee Department of Chemical Engineering IIT Kanpur

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

The 30-Minute Guide to ICP-MS

Low level Os isotopic measurements using multiple ion counting

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Defining quality standards for the analysis of solid samples

Rapid and precise calcium isotope ratio determinations using the Apex-ACM desolvating inlet system with sector-field ICP-MS in low resolution

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Mass Spectrometry in MCAL

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

ICPMS Doherty Lecture 1

Trace Analyses in Metal Matrices Using the ELAN DRC II

Hands on mass spectrometry: ICP-MS analysis of enriched 82 Se samples for the LUCIFER experiment

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

ICP-MS. High Resolution ICP-MS.

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Secondary ion mass spectrometry (SIMS)

2101 Atomic Spectroscopy

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Determination of Elements at Sub-ppb Concentrations in Naphtha Mixtures Using the NexION 300 ICP-MS

Sodium Chloride - Analytical Standard

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

MODULE 4.3 Atmospheric analysis of particulates

Fundamentals of Particle Counting

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques

6.5 Optical-Coating-Deposition Technologies

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Sample Analysis Design PART II

1. The range of frequencies that a measurement is sensitive to is called the frequency

Introduction to GC/MS

Sampling. Information is helpful in implementing control measures for reducing pollutant concentration to acceptable levels

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

TANDEM MASS SPECTROSCOPY

DISCLAIMER: This method:

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Analysis of Polar Metabolites using Mass Spectrometry

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Determination the elemental composition of soil samples

ICP-MS. Inductively Coupled Plasma Mass Spectrometry. A Primer

Sample Analysis Design Polyatomic Interferences

The Easy Guide to: Inductively Coupled Plasma- Mass Spectrometry (ICP-MS)

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

FEASIBILITY OF IN SITU TXRF

Secondary Ion Mass Spectroscopy (SIMS)

ICP-OES Application Note Number 35

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Portable type TXRF analyzer: Ourstex 200TX

EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

Sources of Errors in Trace Element and Speciation Analysis

Test Method: CPSC-CH-E

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

MS Goals and Applications. MS Goals and Applications

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

M M e M M H M M H. Ion Sources

Thermo Scientific Neptune XT MC-ICP-MS

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

MS Goals and Applications. MS Goals and Applications

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

AIR-O-CELL CSI. Bioaerosol Sampling Cassette For the collection of viable and non-viable airborne particles. Laboratory & User Manual

Atomic Spectroscopy AA/ICP/ICPMS:

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Optical Atomic Spectroscopy

Protocol Particle size distribution by centrifugal sedimentation (CPS)

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

Basic Digestion Principles

OPTIMIZING METALS SAMPLE PREP

Use of ICP-MS in analysing radioisotopes. Per Roos Risø National Laboratory for Sustainable Energy, Technicial University of Denmark

Transcription:

Plasma Interface Element2

Interface (backside) & Extraction Lens

Extraction Lens (-2000 volts)

ION OPTICS IF this positive potential is great enough, a discharge from the plasma into the orifice is observed called secondary discharge ( ARCing ) host of bad effects including - orifice (cone) erosion - multiply charged ions - variance in the kinetic energy of the ions

Ion Focusing Purpose - deliver ions to mass analyzer focuses and directs ion beam

ION LENS (TRANSFER LENS) STACK

ION LENS (TRANSFER LENS) STACK The Transfer Lens system is used to: 1. extract the ions entering the analyzer section through the orifices of the cones with very high velocity; i.e. supersonic speed; 2. focus the divergent ion beam onto the target (Entrance Slit), 3. correct the direction of the beam to the target (Entrance Slit) 4. accelerate the ions to their full speed by applying high voltage 5. shape the ion beam into a flat shape so as to make it through the Entrance slit. The ions are subsequently travelling with the desired velocity through the focus point (Entrance Slit) and start to diverge again slightly. In order to control the ion beam during the travel path through the Magnetic Field and the Electric Field, the system controls the rotation of the beam and focuses again to the next focus point.

The proportion of ions sampled from the plasma that make it through to the detector is actually extremely small (1 part in 10 6 to 10 8 ), therefore, a high ion gain detection system is required if low detection limits are to be achieved

Ion Focusing General Assumptions 1. All ions are free particles with positive charge 2. Density of ion beam is not great enough to induce repulsion ( space charge effects) 3. Presence of ions does not change electrostatic fields 4. Vacuum conditions are adequate to give ions necessary mean free path 5. Ions originate with a constant kinetic energy

Ion Optics In an ideal world... All ions leaving the plasma would have the same kinetic energy regardless of m/z ratio This would result in uniform ion transmission through the lens stack

Ion Optics In the real world... All ions are essentially accelerated to the supersonic velocity of Ar in the supersonic jet This results in a range of kinetic energy that is a function of mass

ION ENERGY vs m/z MAX. ION KE (ev) m/z

Ion Optics What does this mean? A single set of ion lens settings will not be appropriate for all elements Therefore, must COMPROMISE (unless looking at a narrow mass range)

Space charge effects The mutual repulsion of ions of like (similar) charge limits the total number of ions that can be compressed into a beam of given size

Space Charge Effects Plasma - ion flux is balanced by the electron flux - essentially neutral Supersonic jet - ion flux is balanced by the electron flux - essentially neutral Lens stack - electrons are repelled by negative potential - ion beam gains positive charge

Space Charge Effects Remember our assumptions - density of ion beam not great enough to induce space charge effects ASSUMPTION NOT MET -further reason for non-ideal behavior and different response across the mass range

Question: what elements are most likely to be effected by space charge effects?

Space Charge Effects Space charge effect is most strongly felt by lighter mass elements The space charge force (positive-positive repulsion) acts on all ions equally

Space Charge Effects Recall most of the ions present are Ar = mass 40 Elements lighter than mass 40 are going to undergo space charge effects even if there is no other matrix element!

Question: why are the low mass elements effected by space charge effects to a greater degree?

Space Charge Effects Heavy elements are effected less than light elements Heavy matrices cause more problems than light matrices Best case scenario = analysis of uranium in water Worst case scenario = analysis of Li in organicrich solution

ESA Detector ELEMENT SCANNING HIGH RES ICP-MS DEVICE Entrance slit Quad lenses Magnet & flight tube Extraction lenses Skimmer Sampler ICP Neb & Spray chamber

Attom HIGH RES- ICP-MS INSTRUMENT

Detectors The purpose of an electron multiplier is to detect every ion of the selected mass that has passed through the energy (mass) filter of a mass spectrometer. The basic physical process that allows an electron multiplier to operate is referred to as secondary electron emission. When an ion or electron strikes a surface it can cause electrons located within the outer layers of atoms to be released. The number of secondary electrons released depends on the type of incident primary particle, its energy, and characteristic of the incident surface. In general, there are two basic types of electron multipliers commonly used in mass spectrometric analysis: these are discrete-dynode and continuousdynode electron multipliers. The Element 2 and AttoM HR-ICP-MS instruments both contain a discretedynode electron multiplier (manufactured by ETP Electron Multipliers, Australia).

Detectors Discrete-dynode electron multipliers amplify the secondary electron emission process by using an array of electrodes referred to as dynodes. Ions hitting the first dynode cause secondary electrons to be emitted from the surface. The optics of the dynodes focuses these secondary electrons onto the next dynode of the array, which in turn emits even more secondary electrons from its surface than the first dynode. Consequently, a cascade of electrons is produced between successive dynodes, with each dynode increasing the number of electrons in the cascade by a factor of 2 to 3. This process is allowed to continue until the cascade of electrons reaches the output electrode where the signal is extracted. A typical discrete-dynode electron multiplier has between 12 and 24 dynodes and is used with an operating gain of between 10 4 and 10 8.

Detectors For a new (unused) electron multiplier, the gain is achieved with a lower applied voltage (~1800 volts). With time and usage, the surfaces of the dynodes slowly become covered with contaminants from the high vacuum system, which results in a decrease of their secondary electron emission capacity (and consequently drop in gain ). Thus, the operating high voltage applied to the electron multipliers must be periodically increased in order to maintain the required multiplier gain.

ELECTRON MULTIPLIER -2800 V ANALOG OUT, GATE GAIN ~ 10 6 + -3000 V PULSE COUNTING OUTPUT GAIN ~ 10 8

Detectors

Detectors discrete dynode electron multiplier

Detector cont d Single detector with two stages- Upper ANALOG stage for high intensity signals (>5x10 6 counts per second- cps) Lower PULSE counting stage for low intensity signals (<100,000 cps) Both stages can be used in the range of 100,000 to 5x10 6 cps However, the two stages need to be calibrated against one another

Detector Calibration This procedure converts the analog signal to an effective count rate (cps) in order to plot intensity on the same scale from the ppb to ppm range During the calibration, the lens voltage is adjusted to attenuate the ion beam in order to obtain points in the cross calibration region Only one solution is required for this calibration procedure

Detector Calibration - AttoM The detector system of the AttoM comprises up to three different stages: Pulse counting electron multiplier, attenuated pulse-counting multiplier and Faraday (not available on our instrument) The instrument continuously monitors beam intensity and performs automatic switchover between detector modes as required. The crossover between the modes should be calibrated on a regular basis, depending on the applications and the required precision.

Sample Introduction System Liquid Peristaltic pump or automated sampling system Nebulizer Spray chamber Plasma torch

Sample Introduction System Peristaltic Pump Pump liquid sample towards nebulizer and plasma torch

Sample Introduction System NEBULIZER Its function is to mix the liquid sample with the nebulizer gas (Argron) to produce a fine sample aerosol for introduction to the plasma discharge area.

Sample Introduction System NEBULIZERS 3 main categories Pneumatic - concentric, cross flow, Babington, v-groove, Cone Spray Ultrasonic Direct insertion

Aerosol production Liquid sample aspirated either in free aspiration mode or with a peristaltic pump -usually made of glass or various kinds of polymers (for highly corrosive liquids/samples) Ar gas (0.6 to 1.2 L/min)

Elemental Scientific Inc. MicroFlow PFA Nebulizer 100% Teflon Self-aspiration: 20 µl/min 50 µl/min 100 µl/min 400 µl/min

Concentric nebulizers

Concentric nebulizers Self-actuating Solutions are drawn up by the pressure drop generated as the nebulizer gas passes through the orifice also referred to as freerunning or self-aspiration. Thus, a peristaltic pump is not necessarily required. Advantage- Generally, the ion signal is much more stable

Concentric nebulizers Disadvantages cannot handle high total dissolved salts (TDS - 0.25% m/v solids); i.e. 250 mg sample dissolved in 100 g of solution samples with different viscosities will have different flow rates liquid uptake tied to nebulizer gas flow cannot easily increase flow for different samples

Optimal Ar gas flow rate

Concentric nebulizers However.. Can use concentric nebulizer in conjunction with peristaltic pump - more commonly used than selfaspirating mode viscosity effects are reduced liquid uptake is metered by pump rate pump rate can be changed for each sample Disadvantages - Can occasionally lead to poorer precision due to pulsing of the flow

Ion signal pulsing

Spray Chamber Its function is to eliminate all droplets with the exception of those that are the correct size and velocity for introduction into the plasma since plasma discharge is inefficient at dissociating large droplets (>10 micron- 1x10-6 metres). The latter are eliminated by gravity and exit through a drain tube. An aerosol with a diameter of ~1-5 microns is considered to have an ideal diameter for introduction into the plasma. Its secondary purpose is to smooth out pulses that occur during the nebulization process

SPRAY CHAMBER & SOLVENT REMOVAL Aerosol out Coolant Drain Fig. 21. Cooled spray chambers for solvent removal. a) cooled double pass Scott chamber b) Cyclone chamber, side and top views. In both chambers, most of the large droplets are deposited at the bends, while fine droplets pass out to the plasma.

Example of wet plasma introduction system -Spray chamber is cooled to 5 C in order to provide thermal stability, minimize the amount of sample entering the plasma, and reducing the quantity of oxide species. -Oxide species (M + O - vs. M + ) should be kept to below 3% of total ion signal; If not, then the plasma has not been correctly fine-tuned.

Desolvating Introduction System- Dry Plasma (e.g. DSN-100, Nu Instruments)

DSN-100 The main purpose of the heated spray chamber and PTFE membrane is to drive-off water from the sample, and thus reducing the overall size of the aerosols (hence the term dry plasma). This action results in increasing the instrument s sensitivity ; i.e. the DSN-100 introduction system yields ~10 times more ion signal compared to a meinhard nebulizer + cyclonic spray chamber (wet plasma) introduction system.

DSN-100 Sample aspiration occurs in free aspiration mode, typically at a rate of 50 to 100 microlitres per minute, with a Meinhard (micromist) nebulizer The nebulized sample (fine aerosols) are introduced into a heated (110ºC) spray chamber, where it is vapourized The vapourized sample is then carried into a heated (110ºC), semi-porous PTFE membrane wall and then transported away by an external gas stream (membrane gas flow)

Torches 2 main types: fixed and demountable fixed: 1 piece demountable: injector tube removable

Torches typically constructed of quartz glass injector tubes can be made of a variety of materials alumina tubes for HF solutions injector tubes can have varying diameters to accept a range of TDS solutions

Sample Analysis Design Solution Mode

Sample Analysis Design Step I Sample preparation The quality of your data will only be as good as the quality of your sample i.e. did you adequately prepare your sample in the clean lab? With respect to the destruction of matrices for samples requiring digestion Did you adequately spike samples with the correct internal standard? Sample handling protocol is extremely important, e.g. weighing

Sample Analysis Design Solid Samples Analyze in solid state via LA-ICP-MS? Analyze in solid state via SIMS secondary ion mass spectrometry? Convert into a glass bead and analyze via XRF x-ray fluoresence? Take powder and digest into solution with acids?

Sample Analysis Design- Liquid (aqueous) samples run as-is? filter then run? dilute then run? acidify, dilute, then run?

Sample Analysis Design Method of sample preparation also depends upon the elements of interest e.g. don t analyze your samples in a hydrofluoric acid medium if you wish to measure Si abundances why? Elemental concentration determinations at ultra-trace level (ppb, ppt) are very susceptible to contamination during sample preparation and therefore should be conducted in clean laboratory environments

Sample Analysis Design Clean room environment Laboratory clean room is a facility in which the concentration of airborne particles is controlled to specified limits. Eliminating sub-micron airborne contamination is a control-driven process since contaminants are generated by people, process, facilities and equipment. Hence, sub-micron particles must be continually removed from the air.

Sample Analysis Design Clean room environment Typical office building air contains from 500,000 to 1,000,000 particles (0.5 microns or larger) per cubic foot of air. A Class 100 cleanroom is designed to never allow more than 100 particles (0.5 microns or larger) per cubic foot of air. Class 1000 and Class 10,000 cleanrooms are designed to limit particles to 1000 and 10,000, respectively

Sample Analysis Design Clean room environment A human hair is about 75-100 microns in diameter. A particle 200 times smaller (0.5 micron) than the human hair can cause major disaster in a clean room. Human hair typically concentrates elements/contaminants such as Pb!

Facilities: Sample Analysis Design - Sources of contamination Walls, floors and ceilings Paint and coatings Construction material (sheet rock, saw dust etc.) Air conditioning debris Room air and vapors Spills and leaks

People: Sample Analysis Design - Sources of contamination Skin flakes and oil Cosmetics and perfume Spittle Clothing debris (lint, fibers etc.) Hair

Sample Analysis Design - Contamination Control HEPA (High Efficiency Particulate Air Filter) - Extremely important for reducing contamination - filter particles as small as 0.3 microns with a 99.97% minimum particle-collective efficiency. Clean room design requires air flow dynamics to be the least disruptive as possible laminar flow Cleaning!

Sample Analysis Design - Contamination Control Purity of reagents, acids, cleanliness of digestion vessels, sample bottles, etc can dramatically effect background levels and data quality If possible, use highest purity commercial acids At the minimum - sometimes need to further process reagents e.g. acid distillation in our laboratory Digestion vessels made of disposable fluorinated polymers (teflon, PFTE, PFA, etc) Solutions stored in polypropylene or equivalent

Sample Analysis Design Concentration terminology Concentrations are typically expressed as either µg/g, or µg/ml (1 µg - microgram = 1 x 10-6 grams), or ppm, ppb, ppt ppm = parts per million = 1 x 10-6 g/g = 1 µg/g (µg = microgram) ppb = parts per billion = 1 x 10-9 g/g = 1 ng/g (ng = nanogram) ppt = parts per trillion = 1 x 10-12 g/g = 1 pg/g (pg = picogram)

Sample Analysis Design Concentration terminology E.g. Zircon ZrSiO 4 ZrO 2 = 67.2 wt% SiO 2 = 32.8 wt% Atomic mass of Zr= 91.224 Atomic mass of Si= 28.0855 Atomic mass of O= 15.9994 % Zr in ZrO 2 = 91.224/(91.224 + (15.9994*2)) = 74 % Si in SiO 2 = 28.0855/(28.0855 + (15.9994*2)) = 46.7

Sample Analysis Design Concentration terminology If 100% = 1,000,000 ppm, then 74% Zr (out of 67.2 wt%) = 49.73% or 497,300 ppm (or µg/g) 46.7% Si (out of 32.8 wt%) = 15.32% or 153,200 ppm (or µg/g) If you are asked to weigh out 0.00001 g of zircon, then the amounts of total Zr and Si you would have are: Zr = 497,300 µg/g x 0.00001 g = 4.97 µg Si = 153,200 µg/g x 0.00001 g = 1.53 µg

Sample Analysis Design Concentration terminology However, you are asked to prepare a solution of this zircon sample for ICP-MS analysis in solution mode; then what would be the minimum dilution factor required given that the maximal amount of ion signal intensity allowed is 50 x 10 6 cps and the yield for both elements in medium resolution mode is ~60,000 cps/ppb?

Sample Analysis Design Concentration terminology Maximum allowable concentration is = Max. count rate/ yield = 50 x 10 6 cps/ 60,000 cps/ppb = 833 ppb (ng/g) 4.97 µg of Zr needs to be diluted into? ml of 5% HNO 3. 4.97 µg = 4970 ng/833 ng/g = ~5.97 g (ml) of 5% HNO 3