Assessment of the Azimuthal Homogeneity of the Neutral Gas in a Hall Effect Thruster using Electron Beam Fluorescence

Similar documents
Characterization of the operation of RITs with iodine

Electric Propulsion Activities at ONERA

Experimental investigation of magnetic gradient influence in a coaxial ECR plasma thruster

Figure 1, Schematic Illustrating the Physics of Operation of a Single-Stage Hall 4

Telemicroscopy Erosion Measurements of 5 kw-class Hall Effect Thruster Channel Walls

An Interferometric Force Probe for Thruster Plume Diagnostics

M2 TP. Low-Energy Electron Diffraction (LEED)

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

ELECTROMAGNETIC WAVES

Discovered by German scientist Johann Hittorf in 1869 and in 1876 named by Eugen Goldstein.

Alternative Neutralization Technique for a 40 Watt Quad Confinement Thruster

RESEARCH ON TWO-STAGE ENGINE SPT-MAG

Geometry optimization and effect of gas propellant in an electron cyclotron resonance plasma thruster

PlaS-40 Development Status: New Results

Effect of Plasma Plume on CubeSat Structures as a Function of Thrust Vectoring

Applied-Field MPD Thruster with Magnetic-Contoured Anodes

An Experimental Study to Show the Effects of Secondary Electron Emission on Plasma Properties in Hall Thrusters

Full Ion Velocity Distribution Function measurement in an Electric Thruster, using LIF-based tomographic reconstruction

Research and Development of Very Low Power Cylindrical Hall Thrusters for Nano-Satellites

Development and qualification of Hall thruster KM-60 and the flow control unit

New 2d Far Field Beam Scanning Device at DLR s Electric Propulsion Test Facility

188 L. Jakubowski and M.J. Sadowski temperature. Some examples of the registered X-ray images are shown in Fig.1. Figure 1. X-ray pinhole images from

Optogalvanic spectroscopy of the Zeeman effect in xenon

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

Use of emission spectroscopy for real-time assessment of relative wall erosion rate of BHT-200 hall thruster for various regimes of operation

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Experimental Studies of Ion Beam Neutralization: Preliminary Results

Acceleration of a plasma flow in a magnetic Laval nozzle applied to an MPD thruster

Research and Development of High-Power, High-Specific-Impulse Magnetic-Layer-Type Hall Thrusters for Manned Mars Exploration

A simple electric thruster based on ion charge exchange

a. An emission line as close as possible to the analyte resonance line

Advanced Lab Course. X-Ray Photoelectron Spectroscopy 1 INTRODUCTION 1 2 BASICS 1 3 EXPERIMENT Qualitative analysis Chemical Shifts 7

3 A NEW FRENCH FACILITY FOR ION PROPULSION RESEARCH

Abstract. Objectives. Theory

S thruster, which is widely used at present on satellites with 1 kw power on bord 3. The main advantages of the

Plasma Diagnostics in an Applied Field MPD Thruster * #

Effects of the Gas Pressure on Low Frequency Oscillations in E B Discharges

Model Answer (Paper code: AR-7112) M. Sc. (Physics) IV Semester Paper I: Laser Physics and Spectroscopy

AS 101: Day Lab #2 Summer Spectroscopy

object objective lens eyepiece lens

Development of Low-Power Cylindrical type Hall Thrusters for Nano Satellite

Volume Production of D - Negative Ions in Low-Pressure D 2 Plasmas - Negative Ion Densities versus Plasma Parameters -

Modelling of magnetic nozzle thrusters with application to ECR and Helicon thrusters

Photoelectric Effect Experiment

The ISIS Penning H - SPS and Diagnostic Developments at RAL

Huashun Zhang. Ion Sources. With 187 Figures and 26 Tables Э SCIENCE PRESS. Springer

Neutral Cesium Velocity Vector and Absolute Number Density LIF Optical Measurement with Application to a Flight Model MICROSCOPE Cesium FEEP Thruster

Influence of Electrode Configuration of a Liquid Propellant PPT on its Performance

Abstract. Introduction

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Lecture 22 Ion Beam Techniques

EMISSION SPECTROSCOPY

Characterization of an adjustable magnetic field, low-power Hall Effect Thruster

Plasma Spectroscopy in ISTTOK

Thrust Balance Characterization of a 200W Quad Confinement Thruster for High Thrust Regimes

Two-electron systems

PPS 1350-G Performance assessment with permanent magnets

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Plasma Behaviours and Magnetic Field Distributions of a Short-Pulse Laser-Assisted Pulsed Plasma Thruster

Diagnósticos em Plasmas

Evaluation of Plume Divergence and Facility Effects on Far-Field Faraday Probe Current Density Profiles

Development of stationary plasma thruster SPT-230 with discharge power of kw

Experimental Study of a 1-MW-Class Quasi-Steady-State Self-Field Magnetoplasmadynamic Thruster

The Q Machine. 60 cm 198 cm Oven. Plasma. 6 cm 30 cm. 50 cm. Axial. Probe. PUMP End Plate Magnet Coil. Filament Cathode. Radial. Hot Plate.

Commissioning of the Aerospazio s vacuum facilities with Safran s Hall Effect Thruster

Robert A. Meger Richard F. Fernster Martin Lampe W. M. Manheimer NOTICE

Radionuclide Imaging MII Detection of Nuclear Emission

FIRST TEST RESULTS OF THE HEMP THRUSTER CONCEPT

Development of a Two-axis Dual Pendulum Thrust Stand for Thrust Vector Measurement of Hall Thrusters

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Miniature Vacuum Arc Thruster with Controlled Cathode Feeding

Sputtering yield of potential ceramics for Hall Effect Thruster discharge channel

EUV lithography and Source Technology

The Quad Confinement Thruster - Preliminary Performance Characterization and Thrust Vector Control

Multicusp Sources for Ion Beam Lithography Applications

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Measurement of the Momentum Flux in an Ion Beam

Beams and magnetized plasmas

Proportional Counters

Langmuir Probe Measurements of a Magnetoplasmadynamic Thruster

Effects of Background Pressure on the NASA 173M Hall Current Thruster Performance

Extrel Application Note

Ten-Ampere-Level, Direct Current Operation of Applied-Field Magnetoplasmadynamics (MPD) Thruster using LaB 6 Hollow Cathode

Operation Characteristics of Diverging Magnetic Field Electrostatic Thruster

Computational Modeling of a High Power Plasma Source for Material Interaction Experiments

Performance Measurements of a High Powered Quad Confinement Thruster.

X-RAY SPECTRA. Theory:

Performance of Plume Characterization of the SPT100-B Thruster

Observation of Atomic Spectra

[2] (b) An electron is accelerated from rest through a potential difference of 300 V.

3 - Atomic Absorption Spectroscopy

Development of Micro-Vacuum Arc Thruster with Extended Lifetime

The Experimental Study on Electron Beam Extraction from ECR Neutralizer

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

The Use of Pulsed Electron Beam Fluorescence for Arcjet Plume Diagnostics

Earlier Lecture. In the earlier lecture, we have seen non metallic sensors like Silicon diode, Cernox and Ruthenium Oxide.

Electron beam scanning

Comparing Internal and External Cathode Boundary Position in a Hall Thruster Particle Simulation

Ratio of Charge to Mass (e/m) for the Electron

Optical Boron Nitride Insulator Erosion Characterization of a 200 W Xenon Hall Thruster

Transcription:

Assessment of the Azimuthal Homogeneity of the Neutral Gas in a Hall Effect Thruster using Electron Beam Fluorescence IEPC-2015-91059 / ISTS-2015-b-91059 Presented at Joint Conference of 30th International Symposium on Space Technology and Science 34th International Electric Propulsion Conference and 6th Nano-satellite Symposium, Hyogo-Kobe, Japan Julien Jarrige 1 and Denis Packan 2 ONERA-The French Aerospace Lab, Palaiseau, 91120, France Olivier Duchemin 3 and Lahib Balika 4 Snecma, Safran Group, Space Engines Division, Vernon, 27208, France Abstract: A diagnostic of Electron Beam Fluorescence (EBF) has been developed to assess the homogeneity of propellant gas injection through the anode of Snecma PPS 5000 Hall Effect Thruster. EBF technique allows measuring the absolute density of gas at the outlet of the discharge channel. The radial profiles of intensity measured at several angular positions after post-processing of the fluorescence images are used to rebuild the map of absolute density. Azimuthal variations of 5% have been measured on a development anode, with incertitude of 2%. I. Introduction ne of the main causes of lifetime limitations in Hall Effect Thrusters is the erosion of ceramic walls of the O discharge channel due to ion impingement. Azimuthal inhomogeneity of the plasma density in the discharge channel would result in non-axisymmetrical plume which could potentially decrease thruster performance and generate a dissymmetry of the erosion process. Therefore it is important to assess the azimuthal distribution of neutral gas in the discharge channel. However very few if any- non-intrusive techniques are capable of measuring accurately the gas density at such low pressure (typically: 10-3 mbar) with a good spatial resolution. In this paper, we present a diagnostic based on electron beam fluorescence for the characterization of the distribution of propellant gas into the discharge channel through the anode, and its demonstration on the anode of a Snecma PPS 5000 Thruster. The thruster is operated is cold gas mode (without discharge) for the measurements of the gas density. 1 Research Scientist, Physics and Instrumentation Department, julien.jarrige@onera.fr. 2 Research Scientist, Physics and Instrumentation Department, denis.packan@onera.fr. 3 Senor EP Engineer, PPS 5000 Project Manager, olivier.duchemin@snecma.fr. 4 Electric Propulsion Engineer, PPS 5000 Project Team, lahib.balika@snecma.fr. 1

II. Apparatus and methods A. Principle of electron beam fluorescence Electron beam fluorescence (EBF) is a technique for measuring the absolute density of atomic or molecular gas. The principle is based on the injection of high energy electrons in a gas: some particles are excited by direct electron impact (pumping) and emit light by radiative de-excitation (fluorescence). In appropriate conditions, the intensity of the fluorescence signal is proportional to the density of gas. The energy scheme, shown in Figure 1, is similar to laser-induced fluorescence (LIF). One of the advantages of EBF is its ability to analyze all types of gases: all atoms and molecules can indeed be excited effectively by inelastic collisions with electrons. Unlike LIF technique, there is no selectivity to species or to energy levels. Moreover, it is possible to analyze all types of atoms or molecules in the ground-state energy level, whereas optical pumping from ground state is not accessible for all species with a laser. For example, the excitation of xenon atom from ground-state with a single photon is not possible with currently available lasers, and two-photon absorption LIF should be used. This last technique is much more complex, lacks sensitivity and requires expensive equipment. An EBF diagnostic has already been used at ONERA for the characterization of a cold gas thruster 1. The absolute density number of argon has been measured in the plume and an electron beam excited laser induced fluorescence (EBLIF) technique has also been developed to measure the velocity of atoms. The energy of electrons in the beam is typically 10 kev with our electron gun. Since the energy required for excitation or ionization of an atom is in the order of magnitude of 10 ev, every single electron can undergo about 1000 inelastic collisions that will lead to excitation or ionization of the gas. The multiple collisions result in deflection of electrons and generation of secondary electrons that can increase the beam divergence and create a halo of light around the beam. In this work, the density of gas was low enough to avoid any significant diffusion of the beam. An example of electron beam fluorescence with a uniform density of gas is shown in Figure 2. Energy level 2 Energy level 1 Ground State Electron impact Fluorescence signal Figure 1. Energy scheme of electron beam fluorescence. Figure 2. Imaging of the electron beam with a uniform density of xenon in the vacuum chamber in front of a PPS 5000 anode. 2

B. Electron beam generation The electron beam is generated by a secondary emission electron gun developed at ONERA, that does not use a filament. The system uses a plasma generated at low pressure (10-4 to10-2 mbar) in a DC wire discharge that can be operated with any type of gas. Ions are extracted through a diaphragm and accelerated towards an auxiliary cathode biased at -10 kv. Secondary electrons that are emitted by ion impact on the metallic surface are than accelerated backwards and form the high energy electron beam that is injected in the vacuum chamber. The beam current is typically a few hundreds microamperes. The beam then passes through an axial coil for collimation and through a slit 2 mm or 5 mm wide to improve the spatial resolution of the diagnostic. Two transverse electromagnets driven by a sine-wave generator sweep the beam parallel to the slit, which creates a sheet of electron 2 mm (or 5 mm) in thickness. The main advantages of secondary-emission electron gun over conventional thermo-ionic electron gun with filament are: its robustness (no hot filament that need to be replaced); its ability to be operated in a wide range of pressure (up to 10-2 mbar) without need of an differential pumping system. Figure 3. Secondary emission electron gun mounted on the vacuum chamber and electromagnets used for collimation and deflection of the beam. C. Experimental setup All tests are performed in B09 vacuum chamber at Onera center of Palaiseau. The vacuum chamber is 0.8 m in diameter and 2 m long (see Figure 4). It is equipped with three turbomolecular pumps that allow a total pumping speed of 2000 L/s for xenon, 2900 L/s for argon, and 3700 L/s for N 2. The ambient pressure is measured with a MKS Baratron gauge (full scale: 0.1 mar) and with a MKS Quattro multi-sensor vacuum transducer. The gas is injected through the anode using a Bronkhorst El-Flow mass flow regulator. A simple method to obtain the map of density is to sweep the electron beam perpendicular to the channel axis at the outlet of the channel and to acquire an image in front of the thruster. It is then possible to detect azimuthal nonhomogeneities. However the multiple reflections of fluorescence light on the walls of the annular channel make the absolute calibration very difficult. 3

In this work, the electron beam can is swept parallel to the axis of the discharge channel, while fluorescence images are acquired through a window on the side of the vacuum chamber (see Figure 5). The main advantage of this method is the possibility to reduce the intensity level of parasitic light with screens. The anode is fixed at the bottom of the annular discharge channel (made of ceramics), and the anode-channel assembly is mounted on a system composed of a rotation stage and a translation stage, as shown in Figure 6. The rotation stage is used to change the angular position of the anode with respect to the beam axis, and the translation stage is used to adjust the distance between the assembly and the electron beam. Fluorescence images are acquired using a Pixis CCD camera from Roper Scientific (back-illuminated, 1340 x 400 pixels) and a 50 mm f/1.4 lens. An example of a raw fluorescence image obtained with the beam swept parallel to the channel axis is given in Figure 7. The radial profile of intensity can then be determined at various distances from the channel exit. The measurement is repeated at different angular position of the anode-channel assembly to rebuild the density map. Figure 4. B09 vacuum chamber. 4

Figure 5. Schematic of the diagnostic with the electron beam swept parallel to the axis of the discharge channel. Figure 6. View of a PPS 5000 anode mounted in the EBF system in B09 vacuum chamber. 5

Figure 7. Example of raw EBF image and extracted radial profile (after post-processing) with gas injected through the anode. D. Post-processing The analysis of fluorescence images requires post-processing in order to remove all sources of light that may disturb the measurement: EBF from the background gas: with B09 pumping capability, about 50% of the fluorescence light is due to ambient gas ; Ion beam fluorescence (IBF): an ion beam with energy of 200-300 ev (~ voltage of the wire DC discharge) is generated simultaneously with the electron beam; these ions, which are not deflected by the electromagnets, also produce some fluorescence light that is superimposed to the EBF signal. Other parasitic sources of light: the ambient gas that is out of the field of vision of the camera also emit fluorescence light that is partly reflected by the walls of the chamber, and the materials that are bombarded by electrons or exposed to soft X-rays may also emit fluorescence light, as can be seen in Figure 2. The diagnostic consists in 4 steps. 1. Acquisition of the EBF image with the gas injected through the anode. 2. Acquisition of the EBF background image: the gas injected from a remote location in the chamber, so that the fluorescence signal is only due to ambient gas. 3. Subtraction of background image: it enables to remove the EBF signal due to ambient gas, and a part of the parasitic light. 4. Correction for the spatial response of the diagnostic: the response of the system is not uniform due to the inhomogeneity of the beam sheet and the transmission of lenses. Typical fluorescence images and radial profiles obtained during the post-processing are shown in Figure 8 and Figure 9. 6

Figure 8. Post-treatment of the fluorescence images. 350000 300000 raw image (gaz through the anode) background image (uniform gas density) background subtraction 180000 160000 140000 background subtraction correction for spatial response 1,0 0,8 Intensity (a.u.) 250000 200000 150000 100000 50000 120000 100000 80000 60000 40000 20000 0 0,6 0,4 0,2 0,0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Figure 9. Example of radial profile of intensity during the post-processing steps. III. Results A. Characterization of PPS 5000 anodes The EBF diagnostic, with the post-processing described above, has been used to characterize two anodes of a PPS 5000 Thruster: a development anode, and an anode to which a default has been added. The mass flow rate of xenon is 5 mg/s, and the measurements are performed every 10 degrees. The maps of absolute density are presented in Figure 10. 7

Development anode 320 0 340 20 Density [m -3 ] 0,0 40 1,0x10 18 300 60 2,0x10 18 3,0x10 18 280 260 020 4060 280 300 320 340 80 260 240 120 100 2200 180 160 140 80 100 4,0x10 18 5,0x10 18 6,0x10 18 7,0x10 18 240 120 8,0x10 18 220 200 180 160 140 9,0x10 18 1,0x10 19 1,1x10 19 Anode with an added default 320 340 0 20 40 Density [m -3 ] 0 1x10 18 300 60 2x10 18 280 260 020 4060 280 300 320 340 80 260 240 120 100 2200 180 160 140 80 100 3x10 18 4x10 18 5x10 18 240 120 6x10 18 7x10 18 220 140 8x10 18 200 160 180 9x10 18 Figure 10. Map of absolute density of xenon for the development anode and when adding a default. Flowrate: 5 mg/s. 8

The azimuthal distribution of propellant gas can then be determined by taking the fluorescence intensity at the maximum of the radial profile at each angle (see Figure 11). The variations are less than 5% for a development anode, and the results indicate variations higher than 20% when adding a default to the anode. Note that the repeatability of the diagnostic has been verified ; the incertitude on the relative azimuthal profile is about 2%. 1,0 Normalized density 0,9 0,8 standard anode anode with default 0,7 0 40 80 120 160 200 240 280 320 360 Angle Figure 11. default. Azimuthal (relative) profile of xenon density for a development anode and when adding a B. Spectral filtering A promising evolution for this diagnostic is the spectral filtering of the fluorescence signal in order to remove efficiently the parasitic light, and to detect only the fluorescence of the gas. A good application of this is the removal of the intense fluorescence light of the ceramic channel due to soft X-rays (see Figure 2), which saturates the CCD and can cause blooming. In the experiments presented above, the light emitted by ceramic was blocked with a screen. However, screening is not always possible. The fluorescence spectra of the gas and of the ceramics are measured with an Acton Insight 400 spectrometer (2.8 aperture ratio, gratings at 300 grooves/mm) and the same CCD camera. The measurements are corrected by the spectral response of the optical setup, which is determined using a calibrated deuterium and halogen/tungsten lamp. The fluorescence spectrum of the ceramics (not shown here) is a continuum whose intensity is very low above 650 nm. Figure 12 show the spectra of three different gases: xenon, argon and air. The electron beam energy is 10 kev for all gases. Air spectrum is dominated by first negative system of N 2 + with the main peak around 391 nm (0-0 transition). An efficient filtering can be obtained with an optical interference filter around this wavelength. Argon spectrum is composed of numerous transitions of neutral Ar and Ar +. The most intense lines are in the range 750-850 nm. On the other hand the xenon emission is spread across a wide spectral range (many small lines are present, even in the UV), so spectral filtering does significantly reduce the intensity. We tested spectral filtering with argon using a high-pass filter with a cutoff wavelength at 715 nm. An example of EBF image is presented in Figure 13 (with no screen to mask the ceramics). The azimuthal profile indicates a very good agreement between xenon measurements (without filtering) and argon measurements (with spectral filtering). 9

1,0 0,8 0,6 0,4 0,2 0,0 1,0 0,8 0,6 0,4 0,2 0,0 1,0 0,8 0,6 0,4 0,2 0,0 [nm] 300 400 500 600 700 800 900 xénon argon air 300 400 500 600 700 800 900 [nm] Figure 12. EBF spectra of xenon, argon, and air. without optical filter with optical filter Figure 13. Effect of the optical filter on the fluorescence image with argon. Low pass filter, cutoff at 715 nm. 10

IV. Conclusion Electron beam fluorescence has been used successfully to assess the homogeneity of propellant gas injection in the discharge channel of a PPS 5000 Hall Effect Thruster. Azimuthal variations of 5% have been measured on a development anode, with measurement incertitude of less than 2%. Spectral filtering has been evaluated and has enabled to apply the technique even in presence of an intense source of parasitic light. Another improvement could be obtained with pulsing the electron beam on a short duration with a high beam current, which would enable to reduce the acquisition time of the CCD camera, and hence the parasitic light level. Finally, it is worth mentioning that the diagnostic could be automated to be implemented on a production line of anodes. References 1 Packan D., Bonnet J., and Rocca S., Number Density and Velocity Measurement in the Plume of a Micronewton Cold Gas Thruster by Electron Beam Fluorescence and Laser Induced Fluorescence, IEPC-2009-184, 31 st International Electric Propulsion Conference, Ann Arbor, USA, 2009. 11