MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

Similar documents
MANUAL TT-220 TT-220

INFRARED THERMOMETER Model : TM-959

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

One-hand ph/temperature measuring instrument

Dual laser + type K thermometer INFRARED THERMOMETER

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Data Sheet / Instructions. Dewpoint MeterO

Dewpoint Meter Data Sheet / Instructions

New! 2010 Model. Model No

INFRARED THERMOMETER TM0819

473-SHX Dew Point Mirror

ED 701 General Industry Pressure Transmitter

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

473 Dew Point Hygrometer

MULTIFUNCTION COMPUTER METER CX-742 USERS MANUAL

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Ultrasonic Thickness Gauge TT130 TIME Group Inc. Beijing TIME High Technology Ltd.

DISCONTINUED PRECISION MEASURING FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS

Electricity. Measuring the force on current-carrying conductors in a homogeneous magnetic field. LEYBOLD Physics Leaflets P

Thermometer Line. today s laboratory and field

Compact ph Measuring Instruments With Pro Engineering

Air velocity & IAQ measuring instruments

TESA MICROMASTER Electronic Micrometers with Digital Display

Ultrasonic Thickness Gauge TIME2110 (V )

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

473 Dew Point Hygrometer

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

0. Table of contents. Author: Jaap Snijder

EDDY CURRENT TESTING

VIBRATION METER. Instruction Manual.

IT Series Infrared thermometer Using manual

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Air velocity & IAQ measuring instruments

Acceleration/Velocity/Displacement VIBRATION METER

Wireless Weather Station Instruction Manual

INE-DDB-303A Portable Conductivity Meter Instruction Manual

1. Electrostatic Lab [1]

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

The Kestrel Handheld Weather Tracker. 1) If the unit is configured to log data and it is turned off, will it continue to log temperature data?

Pressure Transmitter ED 701

Assembly and Operation Manual. April 2016

PiCUS Calliper Version 3

PAA-ANALYZERS PRINCIPLE OF OPERATION

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

SwemaMan 7 Operating instructions vers 1.13 MB_CW

INSTRUCTION MANUAL DTH Fax: (503)

FIELD SPECTROMETER QUICK-START GUIDE FOR FIELD DATA COLLECTION (LAST UPDATED 23MAR2011)

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

Software BioScout-Calibrator June 2013

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Instruction Manual HI Refractometer for Invert Sugar Measurements

Remain Calm, Target Accurately

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

ELECTROMAGNETIC-ACOUSTIC TRANSDUCERS FOR IN-SERVICE MANUAL TESTING OF HEATED OBJECTS

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

Albedo and Heat Absorption

Surface-mounting Thermostats ATH Type Series

Embedded Assessment Notes

Thermometers. Applications

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

2 ACCESSING VARIOUS MODES

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

Today s Weather 24 Hour Forecaster

Title: ASML Stepper Semiconductor & Microsystems Fabrication Laboratory Revision: B Rev Date: 12/21/2010

B Left-hand case side (x1) F

Connect the Vernier spectrometer to your lap top computer and power the spectrometer if necessary. Start LoggerPro on your computer.

Vet Photometer DP 700 Operating Manual. Version V5.9

To Set Time: Turn the set knob on back of the clock movement in either direction.

Dielectric Analysis of Solid Insulations

Microcare LCD Solar MPPT User Documentation

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Wenzhou Tripod Instrument Manufacturing Co., Ltd.

N) manual. Biomaster Operating manual

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

O P E R A T I N G M A N U A L

Operating instructions Infrared temperature sensor TW20xx TW21xx

Instruction Manual HI Refractometer for Sodium Chloride Measurements

SENSOR. Weather TRANSMITTERS

Direct-operated 2/2-way solenoid valves Type EV210B

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

SILICA, Low Range SiLR

Transcription:

MN-ISO-2000FN-E www.insize.com ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL V0

Place the probe on the zero plate and wait until beep. Lift the probe for minimal 5 cm off the zero plate and wait until beep. Then the zeroing is completed. The gauge returns to the measuring mode. Maintenance 1 Accurate measurements can be obtained only by taking correct care of the gauge. Therefore avoid strong shaking, penetration of dust, dirt, chemicals, aggressive substances and water. 2 Do not expose the gauge to extremes of temperature, for example direct sunlight or strong frost. It could influence measure results. The gauge is water-resistant, what corresponds to IP65 norm. The housing is resistant against most solvents. 3 The probe should be regularly controlled. Remove dirt, for example rests of the paint, from the measure head. It is advisable to replace batteries, when you don t use the gauge for a long time. This way you avoid damage owing to low batteries. 4 By disturbances of the gauge or the probe, please don t attempt to repair it by yourself. Our service department will provide expert service quickly and inexpensively. 8 1

Technical specification Measuring magnetic induction probe (Fe) range eddy current probe (NFe) 0~2000µm 0~800µm It is recommended to always choose the calibration points from wished measuring range. For example, if you measure the thickness of the coating between 20 and 200µm you should calibrate the probe on the samples which are about 20, 100, and 200µm. Choose the menu point Calibration, place the probe 4 times on the sample of zero, lift up. Accuracy Resolution Repeatability Measuring mode Calibration mode Minimum substrate thickness Minimum measuring area Power supply Dimension of main unit Weight of main unit Standard delivery ±(1.5+2%L)µm L is measuring thickness in µm 0.1 µm (range < 100µm ) 1µm (range 100~10 00µm ) 10µm (range 10 00µm ) 1µm (range 0~10 00µm ) 10µm (range 10 00µm ) continuous or single four points calibration magnetic induction probe ( Fe): 0.2mm eddy current probe ( NFe ): 0.05 mm 5x5mm, calibration should be made on workpiece without coating, test stand (optional) position for calibration and measurement is recommended in order to have same 2x1.5V AA batteries 122x65x22mm 150g Main unit Zero calibration block for Fe probe Zero calibration block for NFe probe Standard foil Battery (Fe) 7pcs 2pcs 1pc 1pc 1pc 4 Place the probe 4 times on the sample ofthestandard foil. When the display shows a different value from your sample, you have to adjust a value on the display. In this case press the ENTER key. The cursor is on. Move the cursor to the position you want to correct with Right or Left key. The correction of the value is to do with Down or Up key. Then confirm the correct displayed value with ENTER key. Now, take measurements on the sample. 9.Device Inputthe calibration value of the standard foil If you call this option, you obtain the exact data about your gauge and a serial number. Zeroing of the gauge Strong magnetic fields are likely to influence measurements in both the Fe probe and the NFe probe. Variable relations of temperature, exchange of batteries, no using for a long time or various substrates (groundwork) can influence measuring results. In this case you have to zeroing the gauge. Press ZERO in measure mode, Screen displays the following: 2 7

5.Dimension The gauge is available internationally and put into practice. Therefore it is also possible to switch over the unit µm/mm to the American unit of measure - mils ( 1mil = 25.4µm = 0.0254mm). Measure is displayed in µm or mm Measure is displayed in mil Optional accessory Magnetic induction probe ( Fe) Eddy current probe ( NFe ) Test stand Product introduction ISO-2000FN-FE ISO-2000FN-NFE ISO-2000FN-STAND 6.Buzzer Each pressing of the button may be followed by an acoustic signal. This signal you can switch on or off. 7.Language Key-Beep is active Key-Beep is inactive Commands can be displayed in German, English or Polish. 8.Calibration German is active English is active Polish is active The thickness gage and the probe are co-ordinated to each other. But sometimes there is necessary to compensate the external influences, for example, the geometric of the measured object (pipes),smallcontact fields, big changing of temperature, external magnetic fields. In this case or when you connect a new probe, you have toadjust the gauge new. The gage have 7 standard foils for calibration, there are about 15µm, 25µm, 50µm, 100µm, 250µm, 500µm, 500µm. The calibration follows through measuring of four different points from the measuring range. The first one called Zero point corresponds to thickness equal zero and is not changeable. In practice means measuring on the zero plate. The other three points correspond to the measuring on three different samples and can be chosen as you like. There is only important that they have to follow with the rising values for example 10, 100 and 700 µm. Small, handy, robust and easy to handle - these are attributes of the coating thickness gauge. It can suitable for small surfaces, concave or convex surfaces after calibrated. It is designed as a multifunctional instrument and can be used both on magnetic (Fe) and non-magnetic (Nfe) metallic bases. Magnetic induction probe (Fe) is to measure the thickness of nonmagnetic coating on magnetic substrate. Substrate: iron, steel, magnetic stainless steel (does not include nonmagnetic stainless steel ) Coating: zinc, copper, chrome-tin, plastic powder, paint (does not include nickel) Eddy current probe (NFe) is to measure the thickness of non-conductive coating on non-magnetic metal substrate. Substrate: copper, aluminum, zinc, non-magnetic stainless steel Coating: plastic powder, paint, anodizing Key function 1 2 3 4 5 6 7 8 9 Operation Operation 14 13 12 11 10 6 3

1.Probe connector 2.Probe type 3.Number of measurements 4.Back Button 5.Up Button 6.Left Button 7.Menu Button Basic operations 1 Switch on Switch on the gauge with the button. It appears a designation and the last measured value. By placing the probe on the coat, you can directly start your measurements. The probe is plugged on the upper part of the gauge and fixed tightly. When there is no probe, the display shows an indication No probe connected and additionally you hear a Beep. 2 Switch off automatically The coating thickness gauge approx three minutes 3 Menu function 8.Zero Button 9.Down Button 10.Enter Button 11.Right Button 12.On/Off Button 13.Average value 14.Measurement also switches off automatically after The coating thickness gauge has some particular functions, which are stored in the menu. With the MENU key you call the menu, with Down or Up key you move the cursor signs ( <>) and choose the particular function and with ENTER key you call the function. With Exit key you leave the menu and return to measuring mode. 1.Average value The gauge calculates with every measurement (without the storing of single measurement) the average value. If this function is set to On, this value will be displayed together with the number of measurements in the second line of the display. By Off the average will not be displayed. This function is very useful, if the measuring surface has for example a very big roughness. In this case the placing of the probe at the same point of surface doesn t give the same value. It is better to measure for example 5 times and to take as the result the average. 2.Reset Average is displayed Average is not displayed Every time the average value could be reset. If the average should be reset, change with DOWN or UP key from N (No) to Y (Yes) and confirm with ENTER key. In this case the average will be new calculated with next measurement. 3.Background You can turn on or turn off the background light of the display. This function is very useful by using the gauge in the dark environment. Background on Background off 4.Cont Apart from simply point measurements, you can take continued measurements on planes. In this case there will be four times measured and displayed during a one second. Point measurement Continued measurement 4 5