Ion Source. LUXON ION SOURCE The fastest process for mass spectrometry

Similar documents
Ion Source. LUXON ION SOURCE The fastest process for mass spectrometry

Ion Source. LUXON ION SOURCE The fastest process for mass spectrometry

isobaric Barbiturates in Serum using LDTD- MS/MS combined with differential mobility

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Agenda. Principle of Operation Key Features Key Applications in Toxicology Examples of Toxicology Applications Technical Documentation

ABI 3200 Q TRAP LC/MS/MS System

Chemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics

TOXICOLOGY & FORENSIC APPLICATIONS

Analyst Software. Peptide and Protein Quantitation Tutorial

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

High-throughput Quantification of DNA for NGS Library Prep with the Zephyr G3 Workstation and the VICTOR Nivo Plate Reader

DEVELOP YOUR LAB, YOUR WAY

high performance OPTIC 3 and applications a total analytical solution

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

QTRAP and SelexION+- Improving the Sensitivity, Speed and Selectivity in Food, Clinical Research and Pharmaceutical Applications

LC-MS/MS in the Clinical Laboratory. Jo Adaway

Defining quality standards for the analysis of solid samples

Figure 1. The supported liquid extraction process using the ISOLUTE SLE plate (single well shown)

Revolutionary Sensitivity, Speed, and Performance

Application Note. Authors. Abstract. Introduction. Environmental

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

THE TRIPLE QUAD THAT KNOWS THE VALUE OF TIME. QSight Triple Quadrupole LC/MS/MS Platform. For research use only. Not for use in diagnostic procedures.

1. Intended use. 2. Introduction. 3. Assay description. 4. Limitations. Instruction For Use Gyrolab Generic PK Kit

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Analyst Software. Automatic Optimization Tutorial

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

IN QUALITATIVE ANALYSIS,

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Analytical Instrumentation

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Ideal and powerful solution

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Translational Biomarker Core

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Introducing New Technology for Liquid Handling Quality Assurance

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

Thermo Finnigan LTQ. Specifications

Finnigan LCQ Advantage MAX

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

Powerful Scan Modes of QTRAP System Technology

Guide to Peptide Quantitation. Agilent clinical research

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Solid Phase Micro Extraction (SPME) of Opiates from Urine: Coupling SPME and DESI-MS/MS Detection

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

Overview. Introduction

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

DI 3500 Discrete Aoalvzer

Psychoactive Drugs Urine LC-MS/MS Analysis Kit User Manual

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Whole Tablet Measurements Using the Frontier Tablet Autosampler System

10/18/2006. Biotage A Life Science Technology Company

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

ALA 2008 Workshop Abstract

Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Hplc Lc Ms And Gc Method Development And Validation Guideline For Academic And Industrial Scientists Involved In Method Development And Validation

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Highly automated protein formulation development: a case study

Gyrolab Protein A Kit Quantification of residual Protein A ligands in the presence of excess amounts of IgG

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Analysis and Quantification of Mycotoxins in Cereals Using MRM HR on the SCIEX X500R QTOF System with SCIEX OS

Selecting and planning for the right mass spectrometer

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Technical Procedure for Solid Phase Extraction of THC and THC-COOH for GC-MS Analysis

Mass Spectrometry Solutions for Qualitative and Quantitative Analysis. Best in Class. High performance advanced LC/MS/MS systems

TR ACE ORGANIC. lgcstandards.com/foodandenvironment

TANDEM MASS SPECTROSCOPY

Zoe Blaxill Analytical Sciences Discovery Research. High Frequency Acoustic Technology: Evaluation for Compound Mixing and Dissolution in HTS.

Multi-residue analysis of pesticides by GC-HRMS

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Transcription:

Ion Source LUXON ION SOURCE The fastest process for mass spectrometry

The Future is now with the Luxon Ion Source based on the patented LDTD technology Couple the Luxon Ion Source to your Sciex mass spectrometer and attain an analysis runtime of less than 1 second. This apparatus is the second-generation sample introduction and ionization source based on the LDTD technology for mass spectrometry. Versatile multicomponent system adjustable to your bench setup : FREESTANDING ON MASS SPECTROMETER 10 LAZWELL Plate Stacker/unloader OR Plate loader for 24/7 continuous workflow Source Electronic Controller Box COUPLED TO MOTORIZED BASE Touch screen with 3 different MS heights memory settings Motorized Base

Imagine your runtime under 1 second! Luxon Ion Source offers outstanding analytical performance through several features : LUXON ION SOURCE < 1 second sample-to-sample analysis Plug-and-play Low volume samples No carry over, no memory effect Uninterrupted automated workflow No liquid waste management Watch the Luxon Ion Source in action by scanning the QR code or find it on Youtube : youtu.be/kusvnptfvgy

Luxon, an Ion Source at the Speed of Light Laser Diode Thermal Desorption, the heart of the technology The Fiber Optic Collimator allows unmatchable thermal uniformity at the back of the LazWell plate without having to directly interact with the sample. A cooled Fiber-Coupled Laser Diode Array and a heatsink to disregard room temperature variations. The rapid and robust pneumatic design ensures that the gas-phase neutral molecules are carried from the LazWell plate to the mass spectrometer inlet while sealing the transfer tube to avoid any sample loss.

This entire process takes less than 1 second A low-volume sample (50nl-10μl) is deposited on the LazWell plate and then fully dried. The patented LazWell design allows for the formation of a precisely centered nanolayer on the well surface. PRINCIPLE OF OPERATION The thermally desorbed neutral molecules are carried into a corona discharge region to undergo ionization. High-efficiency protonation and strong resistance to ionic suppression characterize this type of ionization and is the result of the absence of solvent and mobile phase.

Other features of Luxon Ion Source Plug-and-play LIGHT-WEIGHT AND EASY TO USE With the Luxon Ion Source you can now easily switch between your LC and Luxon within minutes! It is simple to install and remove which allows you to run your mass spectrometer and analyze your data as usual. The Luxon Ion Source provides a robust walk away solution. Easily install Luxon Ion Source on your TripleTOF 6600+ Traceability LUXON FOLLOWS YOUR SAMPLES FOR YOU The Luxon Ion Source contains an incorporated barcode reader for an optimal traceability of your samples which makes it an ideal solution for regulated environments. The Luxon Ion Source driver is supported by most Sciex mass spectrometers. All LazWell plates are automatically scanned by Luxon to insure traceability 24/7 Process for mass spectrometry LUXON TAKES CARE OF YOUR SAMPLES WHILE YOU RE AWAY The Luxon Ion Source can be coupled with a robotic arm and a liquid handler for a completely automated solution, allowing you to run millions of samples without interruption and in a record time. It can also be delivered with a fully-integrated software workflow solution from liquid handling batch files to the LIMS. Use your preferred liquid handling system, pair it with a robotic arm and let it feed your samples to Luxon Ion Source

LazWell plates Our patented LazWell plates work exclusively with the LDTD technology to provide accurate and reproducible results at incredible speed with microvolumes to decrease the cost per sample dramatically. Manufactured in a highly controlled environment, all LazWell models are barcoded on two sides ensuring a perfect fit with the volume-dispensing precision and sample traceability of conventional liquid handling systems. LazWell The original LDTD technology well-plate. It is used for most analyses and is designed to hold microvolumes. Each well can hold up to 10 µl for 96-well model, 2.5 µl for the 384-well model and 1 µl for the 1536-well model, depending on the solvent used. LazWellHDE HIGH DESORPTION EFFICIENCY Based on the original LazWell, this plate is used for samples containing a high ratio of solvents with low surface tensions (MTBE, EtAc, etc). The added coating reins in the solvents, which makes it possible to deposit a larger volume of organic matrices in each well. FEATURES LazWellDEC DESORPTION ENHANCING COATING Specifically designed to analyze molecules in clean matrices, the coating on this plate increases the desorption of carboxylic acids and lipids. Drug discovery has never been easier. LazWellAD ACID DESORPTION Seal the deal with this screening tool. It can be used to desorb any and all molecules, whether acidic or basic, and is especially useful for analyses in loaded matrices. This is the perfect plate for drug tests. Choose your LazWell based on your Luxon model : Models LazWell LazWellHDE LazWellDEC LazWellAD Luxon S-960 fits with LazWell96 LazWell96-HDE LazWell96-DEC LazWell96-AD Luxon S-3840 fits with LazWell384 LazWell384-HDE LazWell384-DEC LazWell384-AD Luxon S-15360 fits with LazWell1536 LazWell1536-HDE LazWell1536-DEC LazWell1536-AD

Combine the Luxon Ion Source with SCIEX Triple Quad, TripleTOF and QTRAP systems - with or without SelexION DMS The Luxon Ion Source is fully integrated on Sciex mass spectrometers and is THE ULTIMATE SOLUTION for ultra high-throughput in quantitative and qualitative analyses. Luxon Ion Source is completely integrated on : TripleTOF System : The disruptive power and speed of Luxon Ion Source redefines the high resolution accurate mass TripleTOF. With Luxon Ion Source, you no longer need to tune MRM transitions. The AutoCalibration feature is available with Luxon to maintain mass accuracy throughout your analysis. Triple Quad System : Combine the speed of the Luxon Ion Source with the robustness of SCIEX Triple Quad mass spectrometer and attain unmatchable runtime for your lab automation. QTrap System : As the fastest and most sensitive QTRAP system, the QTRAP 6500+ matches the Luxon Ion Source perfectly for an enhanced quantitation of low-level compounds with or without SelexION DMS at one second, sample to sample. Luxon Ion Source /TripleTOF System LUXON DIRECT CONTROL SOFTWARE Our Direct Control software offers a fast track for manual tuning while developing a method. Watch your peak take shape in real time!

Complete integration within Sciex Softwares Luxon Ion Source was not only designed to be compatible with Sciex s MS hardware, but also to be fully controlled by Sciex s softwares through our Luxon driver. Analyst Software Analyst Software is the single point of control for the Luxon Ion Source. Your Luxon batch sample launches will be identical to your HPLC s. Phytronix Luxon Driver integration with Analyst Software MultiQuant Software MultiQuant is the best companion software for Luxon Ion Source. In fact, you can process 96, 384 or 1536 samples in a single file! It s the greatest solution on the market if you want a runtime below one second, sample to sample. Luxon Ion Source integration with MultiQuant Software COMPATIBILITY DiscoveryQuant Software The complete integration of Luxon Ion Source with DiscoveryQuant Software boosts mass spectrometry to a new level of automation. Luxon Ion Source integration with DiscoveryQuant Software

Luxon Ion Source can be used for various applications such as : Pharmaceutical Applications DRUG DISCOVERY AND DEVELOPMENT The Luxon Ion Source is a quantitative solution for High-Throughput Screening environments thanks to its sub-second runtime. Perform both In Vitro and In Vivo assays such as : CYP Inhibition Assays Permeability Assays Microsomal and Plasma Stability Pharmacokinetic Studies (ADME Assays) Dried Blood Spot Analysis This speed of readout would be suitable in an HTS environment that calls for <1 s/ sample. In addition, the low volume requirements for LDTD analysis offer the option of miniaturizing some assays, which was previously unattainable. Therefore, the described method can be adopted to execute HTS campaigns using a number of label-free assays: other ADME-Tox assays, enzyme assays, G protein coupled receptor (GPCR) endpoints, biomarkers, phenotypic screening, and so on. Haarhoff et al., Journal of Biomolecular Screening 2016, Vol. 21(2) 165 175 0.91 sec Food and Environment Applications PESTICIDES PHARMACEUTICALS STEROIDAL HORMONES IN WASTE WATER TRACE ANALYSIS OF EXPLOSIVES IN SOIL MORE The Luxon Ion Source meets the industrial needs for quality control in terms of robustness, reproducibility and absence of carryover. Analyze pathogens in complex matrices such as : Boar taint components in pork fat Neonicotinoids in honey or water Carbendazim in orange juice Antibiotics in meat Mycotoxins in animal feed A rapid instrumental at-line method for simultaneous measurement of androstenone and skatole in back fat samples from entire male pigs has been developed. With an automated sample pre-treatment, it will be possible with a single LDTD-MS/MS system to keep up with a line speed of 360 male pig carcasses per hour and to run 16 hours per workday. Cost of operations is expected to be below 0.7 /carcass. Borggaard et all., 63rd International Congress of Meat Science and Technology, 13th and 18th August 2017, Cork, Ireland

Clinical Applications IMMUNOSUPPRESSANTS - ANTI-RETROVIRAL - THERAPEUTIC DRUGS - ETC. The Luxon Ion Source is a robust, rapid and precise solution with your Sciex mass spectrometer for clinical applications. It is capable of completing the quantification of hundreds of samples, in less than 30 minutes, of a multitude of molecules in various matrices such as : Testosterone in plasma 15 Cholesterol in serum 10 Cotinine in human plasma 5 Biomarker creatinine in serum 0 Immunosuppressant drugs 0 10 20 30 40 50 LC-MS/MS (ng/ml) 50 45 40 35 30 25 20 y = 0.9863x - 0.3065 R2 = 0.9915 LDTD-MS/MS (ng/ml) Forensic and Toxicology Applications PAIN MANAGEMENT - DOPING - FORENSIC - NEWBORN TESTING - MORE... The Luxon Ion Source is a quantitative solution for forensic and toxicology laboratories thanks to its many features such as traceability, sub-second runtime and low-volumes required for analysis. We have used the Phytronix LDTD source for several years and have reported out over a 1,000,000 combined tests on LDTD/MS-MS instruments, and of course have submitted many proficiency samples with never an error [ ] it made a 16-hour run by LC decrease to a 15-minute run for 96 samples, and greatly decreased sample volumes required, so fewer QNS samples Perform quantitative analysis of over 120 compounds with Luxon Ion Source such as : Cannabinoids (Natural and Synthetic) Street Drugs (Heroin, Cocaine etc.) Pain Management Drugs (Fentanyl, Oxycodone etc.) Antidepressant Drugs Director of Toxicology Lab FULL WORKFLOW SOLUTION FOR CLINICAL AND TOXICOLOGY APPLICATIONS From Sample Prep to Go/No-Go Decision Making Sample #1485245485 Concentration: 42 ng/ml NEGATIVE Sample #2496843187 Concentration: 189 ng/ml POSITIVE, CONFIRMATION REQUIRED APPLICATIONS

Phytronix Technologies Quebec Area 4535, Boul.Wilfrid-Hamel, suite 120 Quebec, QC, Canada G1P 2J7 Phone 418 692-1414 Fax 418 692-4940 Toll free : 1 877 792-6207 Follow us @Phytronix linkedin.com/company/phytronix info@phytronix.com www.phytronix.com For Research Use Only. Not for use in diagnostic procedures. All product and company names mentioned herein may be the trademarks or registered trademarks of their respective owners. Phytronix shall not be liable for errors contained herein of for incidental or consequential damages in connection with the use of this material. Information, description and specifications in this publication are subject to change without notice. Phytronix Technologies Inc. 2018