Ideas for an Interferometric Thermometer

Similar documents
ICSE QUESTION PAPER Class X Physics (2016) Solution

CLIC Post-collision Diagnostics

Optical and THz investigations of mid-ir materials exposed

Compressor and Chicane Radiation Studies at the ATF. Gerard Andonian, UCLA High Power Workshop January 14-16, 2009 UCLA

Check the LCLS Project website to verify 2 of 6 that this is the correct version prior to use.

Foundation Year Programme

Measurement method for the proficiency testing program

QUESTION 8 GIVEN. Electron beam kinetic energy = 20 MeV Peak current = 1 A Beam pulse length = 1 microsecond Beam pulse frequency = 10 Hz

Physics Second Semester Exam Review 2014

PHYSICS PRACTICAL (CBSE) - X

Laser Optics-II. ME 677: Laser Material Processing Instructor: Ramesh Singh 1

ADVANCED GCE 2825/02 PHYSICS A Health Physics FRIDAY 25 JANUARY Time: 1 hour 30 minutes

Application of Carbon Nanotube Wire for Beam Profile Measurement of Negative Hydrogen Ion Beam

100 Physics Facts. 1. The standard international unit (SI unit) for mass (m) is. kg (kilograms) s (seconds)

Matter mass space atoms solid, a liquid, a gas, or plasm elements compounds mixtures atoms Compounds chemically combined Mixtures not chemically

Coherent Cherenkov radiation from ultra-short electron bunch passing through vacuum channel in conical target

Analysis algorithm for surface crack detection by thermography with UV light excitation

Proton radiography with a range telescope and its use in proton therapy

Physics 610. Adv Particle Physics. April 7, 2014

Topic Student Checklist R A G

arxiv:astro-ph/ v1 15 Sep 2005

Update on Timepix3 Telescope & Grazing Angles Results

Light - electromagnetic radiation

Foundation Year Programme. Entrance Tests PHYSICS SPECIFICATION. For NUFYP SET 2018

PARTICLE ACCELERATORS

Laserphysik. Prof. Yong Lei & Dr. Yang Xu. Fachgebiet Angewandte Nanophysik, Institut für Physik

Revision checklist SP4 5. SP4 Waves. SP4a Describing waves. SP4b Wave speeds. SP4c Refraction

LCLS Injector Prototyping at the GTF

The CLIC active prealignment studies H. MAINAUD DURAND, T. TOUZE CERN

Synthetic Fused Silica Optical and technical grades

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

Student Review Physics Semester B

Foundation Year Programme. Entrance Tests PHYSICS SPECIFICATION NUFYP SET 2017

LECTURE 1: ELECTROMAGNETIC RADIATION

Dielectric Meta-Reflectarray for Broadband Linear Polarization Conversion and Optical Vortex Generation

qq k d Chapter 16 Electric and Magnetic Forces Electric charge Electric charges Negative (electron) Positive (proton)


Cambridge International Examinations Cambridge Ordinary Level

Monoenergetic Proton Beams from Laser Driven Shocks

Unit 4 Parent Guide: Waves. What is a wave?

Analysis of Thermal Diffusivity of Metals using Lock-in Thermography

INTRODUCTION TO MICROWAVE REMOTE SENSING. Dr. A. Bhattacharya

N5 Physics. Key Definitions. Name:

Revision checklist. Step Learning outcome Had a look Nearly there Nailed it! Step Learning outcome Had a look Nearly there Nailed it!

Which of the following can be used to calculate the resistive force acting on the brick? D (Total for Question = 1 mark)

Doppler echocardiography & Magnetic Resonance Imaging. Doppler echocardiography. History: - Langevin developed sonar.

Emittance and Quantum Efficiency Measurements from a 1.6 cell S- Band Photocathode RF Gun with Mg Cathode *

THE ACTIVE PREALIGNMENT OF THE CLIC COMPONENTS H. MAINAUD DURAND, T. TOUZE CERN

Physics GCSE (9-1) Energy

PHYSICS A 2825/02 Health Physics

Scattering by a Multi-Electron Atom, Atomic Scattering Factors; Wave Propagation and Refractive Index

Measurement of wakefields in hollow plasma channels Carl A. Lindstrøm (University of Oslo)

Student Review Sheet. Physics Semester B Examination

Lecture 4: Heat, and Radiation

Physics Assessment Unit AS 2

HASTINGS HIGH SCHOOL

PHYSICS PAST PAPERS PHYSICS PAPER Suppose the handle bars of the wheelbarrow in question 2 were extended, which force(s) would

EUV lithography and Source Technology

Research Physicist Field of Nuclear physics and Detector physics. Developing detector for radiation fields around particle accelerators using:

Beam Optics for a Scanned Proton Beam at Loma Linda University Medical Center

Coimisiún na Scrúduithe Stáit State Examinations Commission

GCSE PHYSICS REVISION LIST

Lecture Fall, 2005 Astronomy 110 1

Outline. Physics of Charge Particle Motion. Physics of Charge Particle Motion 7/31/2014. Proton Therapy I: Basic Proton Therapy

The Final Exam (Exam 4) will be on FRIDAY MAY 11 From 3 5 PM in LR1 VAN

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Level

Introduction. Introduction. Forces An. Forces An. Forces in Action. Forces in Action. Pressure and Pressure. Pressure and Pressure.

OPTICAL PROPERTIES OF THE DIRC FUSED SILICA CHERENKOV RADIATOR

Synchrotron Radiation a Tool for Precise Beam Energy Measurements at the ILC

Topic 5 Practice Test

Physics 20 Work Plan

Final Worksheet. Equation And Constant Summary

Lecture # 04 January 27, 2010, Wednesday Energy & Radiation

Prentice Hall: Conceptual Physics 2002 Correlated to: Tennessee Science Curriculum Standards: Physics (Grades 9-12)

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Short Pulse, Low charge Operation of the LCLS. Josef Frisch for the LCLS Commissioning Team

BETTER DESIGN AND NEW TECHNOLOGIES IMPROVE LASER POWER MEASUREMENT INSTRUMENTATION

Coulomb crystal extraction from an ion trap for application to nano-beam source"

Afternoon. This document consists of 14 printed pages and 2 blank pages.

to calculate gravitational force. d - Know how changes in mass or distance affect the gravitational force between two objects.

EP118 Optics. Content TOPIC 1 LIGHT. Department of Engineering Physics University of Gaziantep

Study of GEM-TPC Performance in Magnetic Fields

ICTP-IAEA Joint Workshop on Nuclear Data for Science and Technology: Medical Applications. 30 September - 4 October, 2013

Saint Lucie County Science Scope and Sequence

Monte Carlo Simulation concerning Particle Therapy

(PHENS) for Active Diagnostics of Radiation Environment in Spacecraft

Regular Reflectance and Transmittance Measurements of Transmissive Materials Using a STAR GEM Optical Accessory

ELECTROMAGNETIC WAVES

Application of Nuclear Physics

Performance Studies of the Vibration Wire Monitor on the Test Stand with Low Energy Electron Beam

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

Cambridge International Examinations Cambridge Ordinary Level

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Level

Soft clean eraser Soft pencil (type B or HB is recommended)

How does your eye form an Refraction

U n 3 n Ba Kr (D) Br (C) Kr (B) Rb (E) 94 37

Lecture Outline: Chapter 5: Telescopes

Physical Science: Embedded Inquiry

AS COMPETITION PAPER 2007

Transcription:

TSL-Note-2004-58 Ideas for an Interferometric Thermometer V. Ziemann The Svedberg Laboratory Uppsala University S-75121 Uppsala, Sweden Abstract We discuss a non-invasive method to measure the temperature distribution variation in water. This can be used to diagnose the spent beam in the beam dump of linear colliders but also the deposited dose rate in a water phantom in oncological applications. Uppsala, Sweden April 7, 2004

Ideas for an Interferometric Thermometer Volker Ziemann The Svedberg Laboratory, 75121 Uppsala, Sweden April 7, 2004 Abstract We discuss a non-invasive method to measure the temperature distribution variation in water. This can be used to diagnose the spent beam in the beam dump of linear colliders but also the deposited dose rate in a water phantom in oncological applications. 1 Introduction In some circumstances a non-invasive temperature measurement is needed. In one case the environment is highly radioactive and does not allow to have normal sensors embedded. In another case embedding a sensor will disturb the measurement significantly due to its own heat capacity. In this note we propose a method that allows measuring the temperature variation in water non-invasively by an interferometric method that utilizes the fact that the refractive index of water is temperature dependent. Energy deposited in the water basin will raise the temperature, change the refractive index and cause a phase shift in the light ray that can be analyzed in an interferometer. Such a system is particularly interesting for monitoring the temperature of the cooling water in the beam dump of future linear colliders where Megawatt of beam power need to be dissipated in a beam dump made of rapidly flowing water. Having a device that measures the water temperature in such a hostile environment to monitor whether the water starts boiling will be crucial for machine protection. Another area is the diagnosis of the deposited energy in water for oncology applications, e.g. verifying the desired longitudinal and transverse dose distribution in a water phantom before patients are treated. In the remainder of this report we will discuss the temperature dependence of the refractive index and the sensitivity of the method. We conclude with thoughts on how this method can be developed further; for example, how to investigate two or three dimensional temperature distributions and the temporal behavior of the deposited energy. 1

2 Refractive Index The central quantity of the described method is the refractive index of water n which is usually around 1.33, but depends on many parameters, such as the temperature or the density of water, but also on the wavelength of the radiation. A compilation of the properties of water and steam can be found in ref. [1]. There an expression for the refractive index of water is given and we reproduce it here for easy reference n 2 1 n 2 + 1 with the coefficients ( ) 1 ρ = a 0 + a 1 ρ + a 2 T + a3 λ2 T (1) a 0 = 0.244257733 + a 4 λ 2 + a 5 λ 2 λ 2 UV a 1 = 9.74634476 10 3 a 2 = 3.73234996 10 3 a 3 = 2.68678472 10 4 a 4 = 1.58920570 10 3 a 5 = 2.45934259 10 3 a 6 = 0.900704920 a 7 = 1.66626219 10 2 λ UV = = 0.2292020 λ IR = = 5.432937 T = T/T ρ = ρ/ρ λ = λ/λ a 6 + λ 2 λ + a 2 7 ρ 2 IR T = 273.15 K (Reference Temperature) ρ = 1.0 g/cm 3 (Reference Density) λ = 0.589 µm (Reference Wavelength). The right hand side of eq. 1 can be solved for n and we can then plot the refractive index n as a function of the temperature while keeping the wavelength and density at their reference values. This plot is shown in Fig. 1. A linear fit to the temperature dependence yields n = 1.341 2.262 10 5 T [K]. (2) The temperature dependence is thus rather small. 2

1.3345 Refractive index of Water for standard density and 0.589 micron wavelength n 1.334 Refractive Index n 1.3335 1.333 1.3325 1.332 260 280 300 320 340 360 380 Temperature [K] Figure 1: The refractive index of water as a function of temperature at standard density and wavelength. A linear fit shows that the curve can be parameterized by n = 1.341 2.262 10 5 T. 3 Sensitivity We now have to investigate how much the phase of a light ray shifts when the water that the ray traverses changes temperature. We note that the wavelength in a medium of refractive index n 1 is given by λ 1 = λ 0 /n 1 where λ 0 is the wavelength in vacuum. The number of wavelength m 1 that fit into a container of length L is consequently given by m 1 = L λ 1 = n 1L λ 0. (3) If the refractive index changes by a value n we thus expect a change in the number of wiggles m given by m = nl λ 0 (4) where we have assumed that the refractive index is constant. If we drop this assumption we can write the previous equation as an integral m = 1 λ 0 n(x)dx (5) where x parameterizes the path. If we now assume that we have a Gaussian temperature distribution T (x) = T 0 e x2 /2σ 2 (6) 3

with a peak temperature variation T 0 and rms width σ we can utilize eq. 2 to relate the temperature profile to the spatial variation of the refractive index and evaluate the resulting integral by elementary means. We find For the reference wavelength λ 0 = λ we find m = 2.262 10 5 2πσT0 λ 0. (7) m = 96.3 σ T 0 (8) where σ is the rms width of the Temperature variation in meters and T 0 the peak temperature variation in Kelvin. Using a typical scale over which the temperature varies of cm and a temperature variation of 1 K we find that the phase of the light ray changes by about unity. This implies that such a minute change will be clearly visible on the interferometer, because the pattern will change through a full cycle. The sensitivity of such a thermometer is given by the product of the size of the temperature perturbation σ and the amplitude of the temperature perturbation T 0. We conclude that such an interferometric thermometer will be capable of measuring temperature variations of the order of a mm and fraction of Kelvin. 4 Development Potential In the previous section we estimated the phase change that the ray experiences when the water temperature changes. Such a measurement can be performed very rapidly and we can envision that we have a wide mirror at the far end of the water container and a movable mirror that can be swept transversely. In this way transverse temperature profile can be obtained. This would be useful in the CLIC beam dump to see how wide the beam spot is one could infer the angular divergence of the incident particle beam, which gives an indication of the disruption at the interaction point. Performing temperature profile measurements from different angles simultaneously would allow to tomographically reconstruct the temperature profile in two dimensions. Note that the quantity measured is T (x)dx and each measurement at a different angle will give the temperature density along the ray. By correlating several such measurements a two-dimensional profile can be reconstructed. Doing such temperature measurements constantly will allow to investigate the temperature diffusion between beam macro-pulses or other irradiations. A potential problem comes from the fact that the varying refractive index will bend the rays and that will result in a varying path length which will add to the phase shift due to the varying refractive index. We plan to investigate this point further. 4

The method can be easily tested in a water container that is heated by a resistive electrical wire (e.g. constantan) where the temperature rise can be adjusted by the current passed through the wire. The feasibility of the interferometric thermometer can also be tested with beam at TSL using the water phantom in the oncology beam line and installing an optical interferometer there. We can then use the proton beam from the cyclotron to deposit energy and investigate the local temperature rise in the water phantom. We typically run with 3 na protons at 180 MeV. which gives about an energy deposition in the water phantom of 0.5 J/s. The range of 180 MeV protons in water is about 25 cm, so all that energy would end up in the water. If we assume that the transverse extent is about 0.1 cm 2 with a pencil beam we expect that all energy is dumped in about 3 cm 3. Considering the heat capacity of water of 4.2 J/(g K) we expect that a few seconds of irradiation will show a few degrees local temperature rise over a few mm and that should be visible. In this way we could then e.g. trace out the spatial and temporal distribution of the deposited energy. The absorption of the rays in water will limit the thickness of the water dump that can be monitored. This problem can partially be alleviated by using extremely clean water which is, e.g. required for radiation protection in a linear collider beam dump. Another problem will come from the fact that the water in the beam dump has to flow very rapidly in order to get rid of the energy and prevent the water from boiling. The ensuing turbulence may cause inhomogeneities in the water that may render the method presented above unusable. Moreover, the entrance window for the interferometer in the highly shielded beam dump will require serious consideration. These point need to be investigated further. References [1] The International Association for the Properties of Water and Steam, Release on the Refractive index of Ordinary Water Substance as a Function of Wavelength, Temperature, and Pressure, Erlangen, Germany, September 1997, available at www.iapws.org/relguide/rindex.pdf 5