Geoelectricity. ieso 2010

Similar documents
Electrical Methods. Resistivity Surveying

Electrical prospecting involves detection of surface effects produced by electrical current flow in the ground.

ELECTRICAL RESISTIVITY TOMOGRAPHY

Geophysics Course Introduction to DC Resistivity

Electrical Surveying (part A)

1. Resistivity of rocks

Geophysics Course Interpreting DC Resistivity Data

ELECTRICAL PROSPECTING METHODS

Geophysics of Exploration for Water. Geoelectric methods III. edited by Peter Vass

CONTENTS 1. INTRODUCTION. 2. THE D.C. RESISTIVITY METHOD 2.1 Equipment 2.2 Survey Procedure 2.3 Data Reduction

Geophysics for Environmental and Geotechnical Applications

Geology 228/378 Applied and Environmental Geophysics Lecture 6. DC resistivity Surveys

CHARACTERIZATION OF SOIL PROFILE OF DHAKA CITY USING ELECTRICAL RESISTIVITY TOMOGRAPHY (ERT)

Experiment VIII Equipotentials and Fields

GLE 594: An introduction to applied geophysics

Introduction. Electrical surveying. Resistivity method Induced polarization method (IP) Self-potential (SP) method

Surface and borehole electrical resistivity tomography

Definition. Useful References

LECTURE 10. Module 3 : Field Tests in Rock 3.6 GEOPHYSICAL INVESTIGATION

2-D Resistivity Study: The Horizontal Resolution Improvement by Introducing the Enhancing Horizontal Resolution (EHR) Technique

ธรณ ฟ ส กส อ.ดร. ส ว มล อ ดพ วย

MOUNT POLLEY MINING CORPORATION TECHNICAL REPORT ON MULTI-ELECTRODE RESISTIVITY AND SEISMIC REFRACTION SURVEYS MOUNT POLLEY TAILINGS DAM PROJECT

4.6 DC resistivity and IP field systems, data processing and interpretation

A Review of Circuitry

Module for: Resistivity Theory (adapted/modified from lectures in PETE 321 (Jensen/Ayers))

Question 3: How is the electric potential difference between the two points defined? State its S.I. unit.

Case Study: University of Connecticut (UConn) Landfill

Environmental and Exploration Geophysics I. Resistivity II tom.h.wilson

Resistivity & IP methods

What are the two types of current? The two types of current are direct current and alternating current.

Electromagnetism Checklist

OPERATIVE GUIDE INDUCED POLARIZATION

PART A: Short-answer questions (50%; each worth 2%)

Azimuthal Resistivity to Characterize Fractures in a Glacial Till. Mark Boris, University of Saskatchewan Jim Merriam, University of Saskatchewan

and the charge on a proton is +e. We never see objects that have a charge which is not a whole number multiple of this number.

Analysis of electrical resistivity data for the determination of aquifer depth at Sapele RD in Benin city

GEOELECTRICAL STUDY FOR DELINEATING UNDERGROUND CAVITIES IN KARST AREAS

4.2 Graphs of Rational Functions

A Hydro-Geophysical Investigation of Groundwater Potential

CHAPTER 1 ELECTRICITY

Introduction to Electricity

2-D RESISTIVITY IMAGING SURVEY FOR WATER-SUPPLY TUBE WELLS IN A BASEMENT COMPLEX: A CASE STUDY OF OOU CAMPUS, AGO-IWOYE SW NIGERIA

Study on the Four- property Relationship of Reservoirs in YK Area of Ganguyi Oilfield

Vertical Electrical Sounding (Ves) For The Determination Of Under Ground Resistivity In Part Of Nigeria Wilberforce Island,Amassoma, Bayelsa State

RESISTIVITY IMAGING AND BOREHOLE INVESTIGATION OF THE BANTING AREA AQUIFER, SELANGOR, MALAYSIA. A.N. Ibrahim Z.Z.T. Harith M.N.M.

Groundwater Sustainability at Wadi Al Bih Dam, Ras El Khaimah, United Arab Emirates (UAE) using Geophysical methods

Physics 2020 Lab 5 Intro to Circuits

Subsurface Characterization using Electrical Resistivity(Dipole-Dipole) method at Lagos State University (LASU) Foundation School, Badagry

Goals: Equipment: Introduction:

Scholars Research Library

Environmental and Exploration Geophysics I. Resistivity II tom.h.wilson

Electricity MR. BANKS 8 TH GRADE SCIENCE

Protons = Charge Electrons = Charge Neutrons = Charge. When Protons = Electrons, atoms are said to be ELECTRICALLY NEUTRAL (no net charge)

PHYSICS ASSIGNMENT ES/CE/MAG. Class XII

AS COMPETITION PAPER 2007

Site Characterization & Hydrogeophysics

Hamed Aber 1 : Islamic Azad University, Science and Research branch, Tehran, Iran. Mir Sattar Meshin chi asl 2 :

Electrostatics: Coulomb's Law

52 VOLTAGE, CURRENT, RESISTANCE, AND POWER

2D Resistivity Imaging Investigation of Solid Waste Landfill Sites in Ikhueniro Municipality, Ikpoba Okha Local Government Area,Edo State, Nigeria.

DC resistivity surveys

Electric Currents and Circuits

Formation Evaluation: Logs and cores

ELECTRICAL RESISTIVITY SURVEYS AT THE ANDERSON RESIDENCE SITE, PORT CLYDE, ME. For: St.Germain-Collins

Chapter 12. Magnetism and Electromagnetism

Electric Currents. Resistors (Chapters 27-28)

I) Resistivity. Literatur: Telford, Geldart und Sheriff (1990): Applied Geophysics, Second Edition, Cambridge University Press, NY.

UNIT 102-2: ELECTRIC POTENTIAL AND CAPACITANCE Approximate time two 100-minute sessions

DC Resistivity Investigation of Anisotropy and Lateral Effect using Azimuthal Offset Wenner Array. a case Study of the University of Calabar, Nigeria

Improved Exploration, Appraisal and Production Monitoring with Multi-Transient EM Solutions

GEOELECTRICAL INVESTIGATIONS OF MARINE INTRUSIONS ON THE ROMANIAN BLACK SEA SHORE

The three-year mapping and monitoring of underground cavity expansion with 2D resistivity survey: What has revealed?

Investigation of Underground Water at Paiko Using Vertical Electrical Sounding Technique in Paiko, Nigeria

Principles of Applied Geophysics

PROCEEDING, SEMINAR NASIONAL KEBUMIAN KE-8 Academia-Industry Linkage OKTOBER 2015; GRHA SABHA PRAMANA

Phys1220 Lab Electrical potential and field lines

Introduction. Pre-lab questions: Physics 1BL KIRCHOFF S RULES Winter 2010

Electron Theory of Charge. Electricity. 1. Matter is made of atoms. Refers to the generation of or the possession of electric charge.

Electricity and Light Pre Lab Questions

Equipotentials and Electric Fields

Capacitance. A different kind of capacitor: Work must be done to charge a capacitor. Capacitors in circuits. Capacitor connected to a battery

ACCURATE SUBSURFACE CHARACTERIZATION FOR HIGHWAY APPLICATIONS USING RESISTIVITY INVERSION METHODS

water L v i Chapter 4 Saturation

Tactics Box 23.1 Using Kirchhoff's Loop Law

Continuous flow of electric charges. Current Electricity

Ideal wires, Ideal device models, Ideal circuits. Ideal models for circuit elements Wires

CLASS XII ELECTROSTATICS

Measurement of Electrical Resistance and Ohm s Law

Circuits-Ohm's Law. 1. Which graph best represents the relationship between the electrical power and the current in a resistor that obeys Ohm s Law?

DELINEATION OF FRESH-BRACKISH WATER AND BRACKISH-SALINE WATER INTERFACES USING VES SOUNDINGS IN SHANI, BORNO STATE, NIGERIA

Chapter 21 Electric Current and Direct- Current Circuits

GY 402: Sedimentary Petrology

Well Logging. Salam Al Rbeawi 2011

The Efficacy of Enhancing Horizontal Resolution (EHR) Technique in Shallow Subsurface Study Using 2D Resistivity Method at Bukit Bunuh

PHYSICS PRACTICAL (CBSE) - X

Downloaded from

- Memorize the terms voltage, current, resistance, and power. - Know the equations Ohm s Law and the Electric Power formula

6 Chapter. Current and Resistance

Identification of aquifer zones by VES method: A case study from Mangalore block, Tamil Nadu, S. India

Magnets attract some metals but not others

Transcription:

Geoelectricity ieso 2010 1

RESISTIVITY SURVEY AT VENETO VILLA GRITTI AT THE TOWN OF TREVISO (VENETO REGION) The survey was carried out to verify the underground presence of the fondations of a rustic building. Due to the impossibility of digging, the resistivity and radar methods were used. The anomalies (pointed out by arrows) produced by foundations ar e clearly visible in the 2- D and 3-D electrical resistivity maps. The results obtained using radar method are also valid, as shown in the section dedicated to radar survey. 2

Electrical Surveying Exploit the differences of various electrical properties of rock and minerals. Resistivity method Detects horizontal and vertical discontinuities in the electrical properties of the ground. Detects 3-D bodies of anomalous conductivity. Hydrogeology and engineering applications for the shallow subsurface. Induced Polarization Makes use of the capacitive action of the subsurface to located zones where conductive materials are disseminated within host rock. Self Potential Uses natural currents generated by electrochemical processes to locate shallow bodies of anomalous conductivity. 3

Resistivity Resistivity usually depends on the amount of groundwater present, and on the amount of salts dissolved in it Resistivity is often used for mapping the presence of rocks with different porosities. Hydrogeology aquifers, contaminant transport, saline pollution Mineral prospecting Artificially generated currents are introduced into the ground and the resulting potential differences are measured at the surface. Basic Electrical Quantities Electrical charges flow around a circuit current flows from positive to negative Electrical current is measured in amperes (amp) the amount of electric charge that passes any point in the circuit in 1 second. The current flows due to a potential difference (Voltage). A 1.5 volt battery produces a potential difference of 1.5 volts. For most materials, the current increases in proportion to the potential difference double the potential difference, the current doubles. Ohm s Law The amount of current flowing when the potential difference is 1 volt is called the resistance of the piece, and is equal to the slope of the graph to the right V I = R (Ω) 4

Basic Electrical Quantities Resistance depends on the material and its shape: A wire of copper has less resistance than one of lead with the same dimensions. A long thin wire has greater resistance than a short, fat one of the same material Doubling the length doubles the resistance Doubling the area of cross-section halves the resistance (similarly to water flow). Resistivity (the quantity investigated by resistivity surveying) characterizes the material independent of its shape it is measure in ohm-m (inverse of resistivity is conductivity) length resistance = resistivity * cross - sectional area cross - sectional area resistivity = resistance* length Rock and Mineral Resistivity From: Kearey et al., 2002 Though some very good conductors (low resistivity) and insulators (high resistivity) do occur naturally (silver and quartz respectively) most rocks fall somewhere between, but with a wide range of resistivites. 5

Rock and Mineral Resistivity Most rock forming minerals, i.e. quartz, feldspar, mica, olivine, are good insulators. Pores and cracks contain groundwater (fairly low resistivity) resistivity of rock is therefore a function of porosity and pore saturation. Water varies from pure (insulator) to salty (good conductor). Salts dissociate into positive and negative ions common salt dissociates into Na + and Cl - -- these move through the water forming a current = Ionic conduction (electronic conduction is due only to electrons occurs in metals and some ores). As the resistivity of a rock is largely due to the pore waters, a single rock can have a large range of resistivites, making lithological identification problematic. Rock and Mineral Resistivity The resistivity of porous, water bearing sediments (formation resistivity, P p ) can be approximated from the porosity (Ф), the water saturation (S w ) and the resistivity of the pore water (ρ w ) Archie s Law a s m n ρ t = ρwφ w = ρ a φ w m n Sw Where a, m, and n are constants determined from field of lab measurements used commonly in the hydrocarbon industry. Archie s law does not hold for clay minerals the fine particles trap a layer of electrolyte around them clay has low resistivity. Resistivity decreases as temperature rises needs to be accounted for in borehole logging. 6

Electrical Flow in Rocks Electrical connections are made through electrodes metal rods pushed a few cm into the ground The current does not travel by the most direct route as a thin layer has the most resistance, the current instead spreads out, both downwards and sideways, though there is a concentration near the electrodes. In uniform ground only about 30% of the current penetrates below a depth equal to the separation of the electrodes. Why 4 Electrodes? So far we have only used two electrodes. In this case the potential difference is measured between the ends of the resistance. This is not done in resistivity surveys because there is a large and unknown extra resistance between the electrode and the ground. The potential difference is instead measured between two other two potential electrodes the voltmeter draws negligible current, therefore the contact potential difference is negligible. Power supply usually run from batteries. Wires have small resistances. Applied voltage ~100 volts, current ~ma Potential difference typically volts to mv. As ions accumulate on the electrodes, they are dispersed by reversing the current flow a few times a second. 7

Vertical Electric Sounding Vertical electric sounding is used when the subsurface approximates to a series of horizontal layers. The electrode array is expanded from a fixed center. If the electrode spacing is much less than the thickness of the top layer, nearly all will remain in that layer. As the electrode spacing is expanded beyond the thickness of the top layer, a significant amount of the current will be flowing through the lower layer. Refraction of Current Paths In a uniform layer the current paths are smooth The current paths refract towards the normal as they cross into a rock of higher resistivity, and away when they cross into a rock of lower resistivity. The angles are related by: ρ 1 tanθ1 = ρ2 tanθ2 As refraction changes the distribution of current in a layered subsurface, compared to uniform ground, the ratio of the potential difference to the current changes, making it possible to measure the change of resistivity with depth. 8

Apparent Resistivity In a VES survey the ratio of current to potential difference changes because: Change of resistivity with depth Because electrodes are moving further apart The second effect has to be removed As current travels through the ground the current paths diverge from one current electrode before converging on the other. Resistance of bundle of paths is proportional to length, but inversely proportional to cross-sectional area Apparent Resistivity If the current electrode separation is doubled, the cross-sectional area quadruples, so the resistance halves. The ratio of potential difference to current, ΔV/I has to be multiplied by a geometrical factor that depends on the electrode separation: ρ a ΔV = geometrical factor * I The factor is such that, for a uniform subsurface, ρ a remains constant as the separation is changed and equals the resistivity of the ground 9

Wenner Array In a Wenner array, the electrodes are equally spaced (spacing = a). Geometrical factor = 2πa, therefore ρ a = 2πa ΔV/I In uniform ground doubling a halves ΔV/I, with ρ a remaining constant. If the subsurface is layered, the value of ρ a depends on the resistivities of the layers the value calculated is the apparent resistivity. As the electrode separation is expanded ρ a changes as more current flows into deeper layers. Two measuring tapes laid end to end. Four electrodes pushed into the ground symmetrically about the junction of the tapes. Electrode separation progressively increased not incrementally as the same increment at a wide spacing would produce little or no change in reading ie 1, 1.5, 2, 3, 4, 6, 8. Stopped when current is deep enough. Wenner VES Survey 10

Wenner VES Survey Apparent resistivity is calculated for each spacing, using ρ a = 2πa ΔV/I Graph is plotted of log 10 ρ vs log 10 a. The curves are both for two layer cases same resistivities but different thickness upper layer. At small electrode spacing the current only penetrates the upper layer. The apparent resistivity at small spacing is therefore the resistivity of the upper layer. Modeling the Data At the largest spacing the curve flatten here most of the current is spending most of its time in the lower layer. Therefore the resistivity of the lower layer approximates the apparent resistivity at large spacing. The fact that the upper layer is thicker in the right-hand plot is apparent from the longer time spent at low apparent resistivity. 11

Modeling the Data In practice the thickness of the layers and the resistivities are found by comparing the actual plot with master curves calculated for different values of thickness and resistivity. Electrode spacing is plotted as a ratio to the thickness of the top layer, a/h 1, and the apparent resistivity as a ration to the resistivity if the top layer ρ a / ρ 1, with different curves labeled by the value of the ratio of the resistivities. The master curve and apparent resistivity curves must be on the same scale. Modeling the Data The apparent resistivity plot is slid over the master curve until a match is found. In this case it would be the ρ a / ρ 1 = 6. The horizontal part of the curve cuts the y-axis at 1.27, giving a value of 18.9 ohm-m for layer 1 (ρ 1 ). The value for layer 2 is thus 6 * 18.9 = 113 ohm-m (ρ 2 ). The thickness of the top layer is found from where the a/h1 curve of the master curve cuts the x axis on the apparent resistivity curve in this case 0.2 m. 12

Multiple Layers In the case of multiple layers, the curve never reaches the resistivity of layer 2 as the current is penetrating into yet deeper layers. The number of layers can be determined by the number of changes from concave to convex, or vice versa kinks. This is the minimum number of layers. In reality, modeling for multiple layers is usually done on a computer, where a theoretical master curve can be compared actual data and a depth vs. resistivity curve created. Limitation of VES Thin layers, or layers with negligible resistivity contrast are said to be suppressed. No hard guidelines on the limits of thickness of a detectable layer usually estimated by modeling. Anisotropic layers have resistivities that vary perpendicular to lamination (shale). The method assumes that layers are horizontal if they are dipping, are series of VES profiles should be carried out. Ambiguity 13

Other Electrode Arrays Schlumberger array: Only the current electrodes are moved further apart. Gradient: Current electrodes fixed, potential electrodes moved. Dipole-Dipole: Two current and two potential electrodes are moved as pairs with a fixed separation. Resistivity Profiling Resistivity profiling investigates lateral changes. In VES an array is expanded symmetrically about a single point. In profiling some or all of the electrodes are moved laterally with fixed spacing. Targets usually include things like faults, intrusions, or ore veins. Far to each side of the boundary the resistivity is constant. The transition becomes complicated as different combinations of the electrodes are in each rock. The Wenner array is particularly complicated, and varies depending on the electrode spacing. The array can also be arranged broadside to the feature. In the case of the gradient array the current electrodes are fixed, and the potential electrodes moved. 14

Mise-à-la-Masse Method If an ore reserve has be proven in a borehole, one current electrode can be put in the borehole in contact with the ore. Another current electrode is put on the surface beyond the extent of the ore. One potential electrode is fixed on the surface above the body. The second potential electrode is moved around (over the surface an/or down the borehole). The apparent resistivity is measured and contoured to indicate the extent of the body. Electrical Imaging Resistivity may vary both vertically and horizontally, so to create a complete image of the subsurface arrays have to be expanded and moved laterally. If the body is very elongated horizontally (veins, faults, layers), a pseudosection can be used. Repeated profiles along the same traverse crossing the body with a range of electrode separations In (a) the electrodes are first moved across the area with a constant separation. The value of resistivity is plotted between the electrodes at the point of intersection of 45 o lines drawn down from the midpoint of each pair. The spacing is changed, and the process repeated. Values are plotted and contoured to create a pseudosection 15

Electrical Imaging A common distortion is a small area of low resistivity such as a massive sulphide giving rise to an inverted V, or pant legs. A Wenner array can also be used, with the values plotted below the midpoint of the array at a depth equal to the electrode spacing. Electrical Imaging It is now possible to convert a pseudosection into to true resistivity section using tomographic theory. In the example to the right the pant legs have been replaced by an oval area much closer to the size of the target 16

References Used 1. Kearey, P., M. Brooks, and I. Hill, An Introduction to Geophysical Exploration, 2002. 2. Mussett, A.E. and M.A. Khan, Looking into the Earth: An introduction to geological geophysics, 2000. 17