DESIGN AND SIMULATION OF UNDER WATER ACOUSTIC MEMS SENSOR

Similar documents
Piezoresistive Sensors

Outline. 4 Mechanical Sensors Introduction General Mechanical properties Piezoresistivity Piezoresistive Sensors Capacitive sensors Applications

Biosensors and Instrumentation: Tutorial 2

Midterm 2 PROBLEM POINTS MAX

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

SENSOR DEVICES MECHANICAL SENSORS

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP(

Piezoresistive sensors

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

Design And Analysis of Microcantilevers Type Sensor With Different Shape of Piezoresistive Patch

1 Force Sensing. Lecture Notes. 1.1 Load Cell. 1.2 Stress and Strain

Strain Gages. Approximate Elastic Constants (from University Physics, Sears Zemansky, and Young, Reading, MA, Shear Modulus, (S) N/m 2

Modeling, Simulation and Optimization of the Mechanical Response of Micromechanical Silicon Cantilever: Application to Piezoresistive Force Sensor

MET 487 Instrumentation and Automatic Controls. Lecture 13 Sensors

Strain Measurement. Prof. Yu Qiao. Department of Structural Engineering, UCSD. Strain Measurement

Measurement Techniques for Engineers. Motion and Vibration Measurement

Strain Gages. Approximate Elastic Constants (from University Physics, Sears Zemansky, and Young, Reading, MA, 1979

Strain Measurements. Isaac Choutapalli

Slide 1. Temperatures Light (Optoelectronics) Magnetic Fields Strain Pressure Displacement and Rotation Acceleration Electronic Sensors

PURE BENDING. If a simply supported beam carries two point loads of 10 kn as shown in the following figure, pure bending occurs at segment BC.

Modelling of Different MEMS Pressure Sensors using COMSOL Multiphysics

PES Institute of Technology

Summary PHY101 ( 2 ) T / Hanadi Al Harbi

Sensors, Signals and Noise 1 COURSE OUTLINE. Introduction Signals and Noise Filtering Sensors: Strain Gauges. Signal Recovery, 2017/2018 Strain Gauges

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

Mechatronics II Laboratory EXPERIMENT #1: FORCE AND TORQUE SENSORS DC Motor Characteristics Dynamometer, Part I

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

Laboratory 7 Measurement on Strain & Force. Department of Mechanical and Aerospace Engineering University of California, San Diego MAE170

Thickness Optimization of a Piezoelectric Converter for Energy Harvesting

Force and Displacement Measurement

Load Cell Design Using COMSOL Multiphysics

PIEZOELECTRIC TECHNOLOGY PRIMER

7.4 The Elementary Beam Theory

STRESS STRAIN AND DEFORMATION OF SOLIDS, STATES OF STRESS

2012 MECHANICS OF SOLIDS

Lecture 4 Pressure Sensing. ECE 5900/6900 Fundamentals of Sensor Design

Mechanics of Solids. Mechanics Of Solids. Suraj kr. Ray Department of Civil Engineering

Bending Load & Calibration Module

[5] Stress and Strain

What is a Strain Gauge? Strain Gauge. Schematic View Of Strain Gauge

Mechatronics II Laboratory EXPERIMENT #1 MOTOR CHARACTERISTICS FORCE/TORQUE SENSORS AND DYNAMOMETER PART 1

Force Sensors. What is a force sensor?

Practical 1P2 Young's Modulus and Stress Analysis

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS

Strength of Material. Shear Strain. Dr. Attaullah Shah

Lecture 6: Piezoelectricity & Piezoresistivity

Institute for Electron Microscopy and Nanoanalysis Graz Centre for Electron Microscopy

Mechanics PhD Preliminary Spring 2017

SENSORS and TRANSDUCERS

Design And Analysis of Microcantilevers With Various Shapes Using COMSOL Multiphysics Software

Introduction to Strain Gage (SG) Technology

EE 5344 Introduction to MEMS CHAPTER 6 Mechanical Sensors. 1. Position Displacement x, θ 2. Velocity, speed Kinematic

Sensors and Transducers. mywbut.com

ANALYSIS AND NUMERICAL MODELLING OF CERAMIC PIEZOELECTRIC BEAM BEHAVIOR UNDER THE EFFECT OF EXTERNAL SOLICITATIONS

Electronics Resistive Sensors and Bridge Circuits

QUESTION BANK DEPARTMENT: CIVIL SEMESTER: III SUBJECT CODE: CE2201 SUBJECT NAME: MECHANICS OF SOLIDS UNIT 1- STRESS AND STRAIN PART A

Strain and Force San José State University A. Mysore Spring 2009

Lecture 15 Strain and stress in beams

Advanced Structural Analysis EGF Section Properties and Bending

Module 2 Mechanics of Machining. Version 2 ME IIT, Kharagpur

Strain, Force, and Pressure

MAS.836 PROBLEM SET THREE

Magneto-Mechanical Modeling and Simulation of MEMS Sensors Based on Electroactive Polymers

Industrial Instrumentation Dr. Alok Barua Department of Electrical Engineering Indian Institute of Technology Kharagpur. Lecture - 4 Strain Gauge

Elasticity: Term Paper. Danielle Harper. University of Central Florida

UNIT 1 STRESS STRAIN AND DEFORMATION OF SOLIDS, STATES OF STRESS 1. Define stress. When an external force acts on a body, it undergoes deformation.

10 Measurement of Acceleration, Vibration and Shock Transducers

MICROMECHANICAL PIEZORESISTIVE TACTILE SENSOR

ENG1001 Engineering Design 1

6. Strain Gages and Strain Measurement

EE C247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2014 C. Nguyen PROBLEM SET #4

EE C245 / ME C218 INTRODUCTION TO MEMS DESIGN FALL 2009 PROBLEM SET #7. Due (at 7 p.m.): Thursday, Dec. 10, 2009, in the EE C245 HW box in 240 Cory.

Design and Analysis of Various Microcantilever Shapes for MEMS Based Sensing

Chapter 3. Load and Stress Analysis

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

STRESS, STRAIN AND DEFORMATION OF SOLIDS

Chapter 3. Inertia. Force. Free Body Diagram. Net Force. Mass. quantity of matter composing a body represented by m. units are kg

EE C245 / ME C218 INTRODUCTION TO MEMS DESIGN FALL 2011 C. Nguyen PROBLEM SET #7. Table 1: Gyroscope Modeling Parameters

PDDC 1 st Semester Civil Engineering Department Assignments of Mechanics of Solids [ ] Introduction, Fundamentals of Statics

St Olave s Grammar School. AS Physics Mock Revision Checklist

MODELING OF T-SHAPED MICROCANTILEVER RESONATORS. Margarita Narducci, Eduard Figueras, Isabel Gràcia, Luis Fonseca, Joaquin Santander, Carles Cané

Equilibrium. the linear momentum,, of the center of mass is constant

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Subject code/name: ME2254/STRENGTH OF MATERIALS Year/Sem:II / IV

Experiment Five (5) Principal of Stress and Strain

High performance doubly clamped piezoresistive accelerometers by the outturn of electroplating

Appendix A Glossary of Mathematical Symbols

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

Design and Simulation of a Novel MEMS Bidirectional Anemometer

9 MECHANICAL PROPERTIES OF SOLIDS

I. MEASUREMENT OF TEMPERATURE

[8] Bending and Shear Loading of Beams

MCE 403 MACHINERY LABORATORY EXPERIMENT 10

Structures - Experiment 3B Sophomore Design - Fall 2006

UNIT 2 STRAIN MEASURMENTS, FORCE MEASUREMENTS. Therefore, resistance strain gauges are also known as piezo-resistive gauges.

Elastic Properties of Solids (One or two weights)

N = Shear stress / Shear strain

Hardened Concrete. Lecture No. 16

A new cantilever beam-rigid-body MEMS gyroscope: mathematical model and linear dynamics

ROTATING RING. Volume of small element = Rdθbt if weight density of ring = ρ weight of small element = ρrbtdθ. Figure 1 Rotating ring

Transcription:

DESIGN AND SIMULATION OF UNDER WATER ACOUSTIC MEMS SENSOR Smitha G Prabhu 1, Nagabhushana S *2 1 Dept. Of Electronics and communication, Center for Nano Materials and MEMS, 2 Dept. of Electronics and Communication, Center for Nanomaterials and MEMS, *Nitte Meenakshi Institute of Technology,Bangalore-560064,smithaprabhu2009@gmail.com Abstract: Silicon based MEMS have wide applications in under water sensors. This work has aims at one such applications, hydrophone, in order to study and improve its performance and dynamic range. The structure consists of two parts: high precision four-beam micro-structure and rigid plastic cylinder which has the same density of water and is fixed at the center of the microstructure. When the plastic cylinder is stimulated by sound, the strain gets generated and the piezoresistor transforms the resultant strain into a electrical output signal. In this paper,the intension is to simulate a MEMS based high precision 4 beam microstructure which can be used for under water applications for detection of the flow direction and flow rate of the medium surrounding the structure using COMSOL multyphysics tool based on the piezoresestive physics. Keywords MEMS vector hydrophone, piezoresistor, 4 beam microstructure 1. Introduction: SONAR operation is based on the propagation of waves between target and a receiver. There are two types of sonar systems: passive and active. In passive sonar systems energy originates at a target and propagates to a receiver whereas in active sonar systems acoustic wave propagates from a transmitter to a target and back to a receiver. Acoustic wave refers to sound wave in any medium. Water being an elastic medium any disturbance in water propagates away from its origin as a wave. When water or air molecules are pushed or pulled apart, they exert a restoring force that resists the motion. The force will be felt locally as pressure or force per unit area. The fundamental parameter of an acoustic wave is pressure and frequency. As the level of radiated noise of submarines become lower and lower each year, the application of vector hydrophone suffice the requirement of submarine sound detection well [1]. Hydrophone detects the pressure variations of acoustic signal and noise in the water and produces an output voltage proportional to the pressure [3]. The free field voltage of hydrophone is defined as the ratio of the open circuit voltage amplitude to the free field pressure amplitude of an incident sound wave which in turn defines also the sensitivity[2].the hydrophone realizes vector detection of underwater acoustic signal.in this paper attempt is made to design and simulate MEMS based underwater acoustic sensor whose working is based on piezoresistive physics.piezoresistive transducers translate a force in to a change in the value of resistor. They are widely used as sensing elements in pressure sensors [4]. 2. Theory of piezoresistive sensing elements: Piezoresistivity is a property of certain materials which change their electrical resistance when being subject to tensile or compressive stresses. Its effect is dominant in semiconductors such as silicon. It is a function of doping, temperature etc. Piezoresistive readout is commonly used to measure the deflection of membranes such as cantilevers. It is possible to deduce the magnitude of force on a cantilever using piezoresistive region at the base where the maximum stress occurs, by measuring resistance changes. If the electrodes are positioned at the two ends of a layer of rectangular material of crystalline silicon of length L, width b and thickness h(i.e, L>>b>>h), the structure is simply a resistor. If the material of the resistor is stress free, the resistivity of the silicon material is a scalar, ρ 0, and the resistance between the two electrodes is R 0=(L ρ 0)/(bh).-------------------------(1) The I-V relationship of the resistor is ohms law for isotropic material, V=IR 0.----------(2) When the material of the resistor is stressed, the resistivity of the material, ρ is a tensor of the second rank relating the electric field tensor and the current density tensor. As the electric field and the electric current in the normal direction of the layer are negligible and there is no such current flow across the side walls of the resistors and the length being much larger than width b one can write E X = ρ 1 J X -----------(3) Ey =ρ 6 J x. -------------(4)Since E x = Vs/L,----------(5) where Vs is the voltage difference between the two electrodes, the current passing through the resistor is : Ix = Jx bh=(bh Vs)/(L ρ 1 ).-------------(6) If this relation is compared with the Ohms law for the isotropic material, we find that the resistance: R=(L/bh) ρ 1. -------------(7) The resistance is stress dependent from the term ρ 1. When this relation is compared with the original resistance R 0= L ρ 0/bh, -----------(1)

the relative change of the resistance is ΔR/R 0=( ρ 1 -ρ 0)/ρ 0= Δ where Δ = π 11T 1 + π 12T 2 + π 13T 3 + π 14T 4 + π 15T 5 + π 16T 6. -------------------------(8) For most applications in pressure transducers and accelerometers, the resistor is placed on the thin diaphragm or beam. Therefore the material is stressed in to two dimensions at the surface plane. In this case T 3 =T 4 =T 5 =0. Now ΔR/R= π 11T 1 +π 12T 2 + π 16T 6 --------------------(9). So two terminal silicon resistor is sensitive to the stress or strain in the material. Therefore it can be used as sensing element for stress or strain. We can also write ΔR/R=π lt l+ π tt t+π st s-------------------------------(10) where subscripts l designates longitudinal, t designates transversal and s designates shearing. Thus π l= π 11 is often referred to as the longitudinal piezoresistive coefficient, π t=π 12 is the transversal piezoresistive coefficient and π s=π 16 is the shearing piezoresistive coefficient. If the resistors are parallel to the beam direction i.e., along x, y is in surface plane and perpendicular to the beam direction and z is normal to the surface plane then π 11 =1/2π 44 and T t=t s=0. ΔR/R=(π 44/2)T l.(11) Therefore, if the Wheatstone bridge has a supply voltage of V s the output is V out= V s ΔR/R---------------------(12) 3.Sensor Design: The structure of hydrophone consists of two parts: high precision four-beam micro-structure and rigidity plastic cylinder which has the same density of water and is fixed at the center of the microstructure. Figure 1 shows the actual design of the structure. In this paper we have simulated four beam microstructure consisting of 4 vertical cantilever beams which are attached to the center block on one side and other end are fixed at the support. Both the center block and the beams have same thickness and the whole structure has complete axial symmetry and shown in figure 2. P type silicon piezoresistors are integrated on cantilever beams. The center block material is silicon with the dimensions being 500 µm long,500 µm thick and 10 µm thick.the cantilever is 1000µm long,120µm wide and 10µm thick. The mass will have a horizontal displacement and an angular rotation, when it is subjected to axial or radial stress. And then the structure will be subject to deformation, an amplified and concentrated strain is generated on the slim sensing beams. The piezoresistors converts the stresses induced in the silicon beam by the applied pressure into a change of electrical resistance, which is then converted into voltage output by a Wheatstone bridge circuit as shown in the figure3. A Wheatstone bridge is widely used to pickup variation in the electrical resistances of the strain gauges. When a bridge is balanced, there is no output voltage (when there is no resistance change from its balance value) but the bridge indicates a voltage output if the resistance is varied from it nominal value. The resistance variation depends on the strain generated in the resistor and mainly by the change in resistivity which is dominant in semiconductors. In this structure two Wheatstone bridges are formed by diffusing eight equal strain Resistor R1,R2,R3,R4,R5,R6,R7,R8 as shown in figure 3. Resistances R1,R2,R3 and R4 connection into the first wheatstone bridge to give the electrical output voltage corresponding to the stress in the axial direction ;R5,R6,R7 and R8 connection into the second wheatstone bridge to give the electrical output voltage corresponding to the stress in the radial direction. This change of resistance is induced by the applied measurand pressure is measured from the Wheatstone bridge. Fig1: Structure of hydrophone Fig2: 4 Beam Microstructure

located at these places of the beam where the stress profile is optimal. Because of this compressive stress there will be change in piezoresistvity of all piezoresistors because of the variation in semiconductor band gap and shown in Figure 8. The structure is applied with various pressures and corresponding change in resistance is tabulated in table 1. It is found that the change in resistivity hence resistance of the resistors used for these types of piezoresistive microsensors is proportional to the external pressure and it changes linearly as shown in fig 7. Figure 3. Distribution of Strain Varactor Connection Diagram 4.Modelling Using Comsol Multiphysics: The sensor geometry as mentioned above is modelled using Comsol Multiphysics 5.0, piezoresistive physics for domain currents module. The geometry is created using a block (the beam) with the given values for width, depth and height and which is attached to the center block. The starting material of a beam is a 7μm p type silicon layer with a 3μm thick n type epitaxial layer. The material used for central block is silicon with L=500μm,W=500 μm and thickness=10 μm dimensions. Two work planes are defined. The dimensions of the resistors and the connections are defined by a 2D drawing on the upper work plane. The material properties like Young s Modulus and Poisson Ratio are set according to the given literature. After this, the structural, electrical and piezoresistive properties of the model were defined. The areas within the boundaries of the beams are determined as thin conductive layers and the area bordered by the geometry of the resistors are defined as thin piezoresistive layers. One of the ends of all four cantilever beams are attached to the center block and the other end are made fixed i,e they are attached to the support or frame. The pressure and force in axial and radial directions are applied as boundary load corresponding to the acoustic particle motion to the center block. 5. Results and Discussion: During simulation, pressure corresponding to the under water acoustic particle motion is applied to the central block ; The center block will have displacement. Therefore the structure will be subjected to deformation, an amplified and concentrated strain is generated. The resultant displacement and stress are recorded. Deformation of beams andstress distribution over the entire volume is shown in Figure 5&6respectively.. It could be could observed that the maximal stress is located at the beam-block interface and near the support frame. The piezoresistors of the structure are Fig5: Displacement when subjected to 10MPa load. Fig6:Stress plot for a pressure of 10MPa Fig5:

Pressure Change in resistivity (MPa) (Ω-m)of resistances R2,R3,R6,R7 10 1.4054 20 2.8107 30 4.1978 40 5.5848 50 7.031 60 8.5497 direction, axial deformation of the beams take place i.e. beam consisting of R3 and R4 is subjected to compression and beam consisting of R1and R2 is subjected to tension as a result resistivity change occurs as shown in Fig 9&Fig 10 and the bridge formed by R1,R2,R3 and R4 provides the output voltage and indicates the direction of force as axial direction i,e as +x direction. The opposite will happen for ve axial direction. Table 1: Data pertaining to pressure and resistivity Change in Resistivity 10 8 6 4 2 0 10M 20M 30M 40M 50M 60M Pressure Series1 Fig7: Linear relationship between change in resistivity and pressure Fig9:Axial deformation of the beams when subjected to 25 N force in +x direction Fig8: Change in piezoresistivity plot for a pressure of 10 MPa. When a lateral force is applied to the central block in x direction the deflection of the central block occurs only in the lateral direction, which means that the vertical deflection and the transverse shear stresses are zero. When the center block is subjected to axial force due to an acceleration, in the x- Fig 10: Change in resistivity plot of the beams when subjected to 25 N force in +x direction When the center block is subjected to vertical motion of the mass due to acceleration in the y direction it induces the bending of the beams and beam consisting of R7 and R8 is subjected to compression and R 6and R 5 is subjected to tension as a result of resistivity change that occurs as shown in Fig 11 & Fig 12 and wheatstone bridge with R5,R6,R7,R8 gives the output corresponding to direction of force in y direction.

The opposite will happen for ve radial direction. The radial and tangential resistance changes due to the radial and tangential strains corresponding to the acoustic particle motion along axial and radial direction. When there is an incentive direct current, the bridge output will be detected as per flow direction and hence the structure is used to detect the vector underwater acoustic signal. REFERENCES Fig 11:Radial deformation of the beams when subjected to 25 N force in +Y direction [1] Shang Chen,ChenyangXue,Binzhen Zhang,Bin xie and Hui Qiao, A Novel MEMS Based Piezoresistive Vector Hydrophone for Low Frequency Detection., Proceedings of the IEEE 2007,1839-1844. [2] ChenyangXue, Shang Chen,Wendong Zhang,Binzhen Zhang,Guojun Zhang, Hui Qiao, Design,fabrication,and preliminary characterization of a novel MEMS bionic vector hydrophone.,microelectronics Journal 38(2007) 1021-1026. [3] Mengran Liu, Guojun Zhang, Zeming Jian*, Hong Liu, Xiaopeng Song, Wendong Zhang, Design of Array MEMS Vector Vibration Sensor in the Location of Pipeline Internal Inspector.,TELKOMNIKA Indonesian Journal of Electrical Engineering,Vol. 12, No. 9, September 2014, pp. 6651 ~ 6657. [4] T Chu Duc,J F Creemer and P M Sarro, Lateral nano-newton force sensing piezoresistive cantilever for microparticle handling, Journal of Micromechanics and Microengineering,16(2006)S102-S106. Fig 12:Change in resistivity plot of the beams when subjected to 25 N force in +Y direction 6. Conclusion: COMSOL Multiphysics was used to investigate piezoresistive effect in p-type silicon for a range of pressure variations and simulation results demonstrate a linear relationship between the resistance change and stress for various pressures loading. The resistance of the piezoresistor implanted in the sensitive structure is changed, when the signal is transmitted to it.