EMISSIVITY OF ALUMINIUM ALLOY USING INFRARED THERMOGRAPHY TECHNIQUE

Similar documents
Thermal behavior study of the mold surface in HPDC process by infrared thermography and comparison with simulation

ANALYSIS OF THE CUTTING TEMPERATURE AND SURFACE ROUGHNESS DURING THE ORTHOGONAL MACHINING OF AISI 4140 ALLOY STEEL VIA THE TAGUCHI METHOD

ACTIVE THERMOGRAPHY FOR MATERIALS NON-DESTRUCTIVE TESTING

ASSET INTEGRITY INTELLIGENCE. Featured Article. ACHIEVING A COMPREHENSIVE FIRED HEATER HEALTH MONITORING PROGRAM By Tim Hill, Quest Integrity Group

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Influence of sun radiation on results of non-contact temperature measurements in far infrared range

Surface crack detection using infrared thermography and ultraviolet excitation

Automatic Adjustment of Integration Time in the NIR Camera for Calibrated Temperature Measurement during Inductive Heating Processes

3. LED THERMAL. a) b) 3.1. Introduction Heat transfer introduction LED ACADEMY/LED THERMAL

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

Thermal Coatings for In-vacuum Radiation Cooling LIGO-T C R. Abbott, S. Waldman, Caltech 12 March, 2007

Fig 1. Power Tower during Operation

Physics 1CL OPTICAL SPECTROSCOPY Spring 2010

ARMCO Iron normal spectral emissivity measurements

Thermal Image Resolution on Angular Emissivity Measurements using Infrared Thermography

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

DEVICE FOR MEASUREMENT OF THERMAL EMISSIVITY AT CRYOGENIC TEMPERATURES

DIRECT RADIOMETRIC TECHNIQUES

YJ-BC-270H-G01 High CRI LED

Application of G100/120 Thermal Imaging Camera in Energy Efficiency Measuring in Building Construction

[ ] Sensors for Temperature Measurement, and Their Application 2L R 1 1 T 1 T 2

Introduction to Infrared Thermometry

On the Emissivity of Silver Coated Panels, Effect of Long Term Stability and Effect of Coating Thickness

Thermophysical Model for the Infrared Emissivity of Metals: Application to Nickel

Inside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor

Xenics Presentation. A 25 minute crash course in Thermography

Atomic Emission Spectra

Temperature Measurement

ROUGHNESS ASPECTS IN THERMAL ANALYSIS OF MACHINE TOOLS

GS-IR 8816 Series Infrared Thermometer

Detectability of pulsed infrared thermography of delaminations in carbon fiber composites

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

Experimental study of the frictional heating phenomenon in elastomers

CORRELATION BETWEEN HOT PLATE EMISSIVITY AND WAFER TEMPERATURE AT LOW TEMPERATURES

Effect of object-to-camera distance on temperature and spatial resolution of a Thermal imaging system FLIR SC 5000

/qirt The influence of air humidity on effectiveness of heat sink work. by M. Kopeć*, R. Olbrycht*

Reflow Soldering Processes Development Using Infrared Thermography

Supporting Information

APAS Laboratory { PAGE } Spectroscopy SPECTROSCOPY

Prof. Dr. Biljana Škrbić, Jelena Živančev

Introduction. Procedure and Data

Analysis algorithm for surface crack detection by thermography with UV light excitation

Experimental and numerical investigations of heat transfer and thermal efficiency of an infrared gas stove

Non-Destructive Inspection of Brazed Joint by Pulsed Phase Thermography

Sapphire Fiber-Optic Temperature Sensor Based on Black-Body Radiation Law

A R C H I V E S O F M E T A L L U R G Y A N D M A T E R I A L S Volume Issue 4 DOI: /v

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

PROCESS MONITORING OF PLASMA ELECTROLYTIC OXIDATION J.-W. Liaw, C.-C. Hsiao, Clinton Fong, Y.-L. Tsai, S.-C. Chung, Oleg Demin Materials Research

Planetary Science: Investigations 9-10 I-Check Quiz STUDY GUIDE- ANSWER KEY Name HR Date

Types of Spectra. How do spectrum lines form? 3/30/09. Electron cloud. Atom. Nucleus

Thermal sensitive foils in physics experiments

Mathematical determination of emissivity and surface temperature of aluminum alloys using multispectral radiation thermometry

Atomic Spectra. d sin θ = mλ (1)

EVERLIGHT ELECTRONICS CO., LTD.

Section 7. Temperature Measurement

Development of spectrally selective infrared emitter for thermophotovoltaic power generation

Examination of metallic surfaces for IR gray body sources

Laboratory Exercise. Atomic Spectra A Kirchoff Potpourri

Use of Matlab package for external local calibration of IR camera with microbolometric FPA detector

M Plan Apo. Long working distance objectives for bright field. DIMENSIONS *Mounting screws 26, thread 36 (see P.30.) SPECIFICATIONS FEATURES

Sensors - April A Certified-Emissivity Blackbody for Calibrating Infrared Thermometers

Infrared thermography

Analysis of Thermal Diffusivity of Metals using Lock-in Thermography

FLAME PHOTOMETRY AIM INTRODUCTION

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

FINITE-ELEMENT THERMAL ANALYSIS OF A NEW COOLER DESIGN

Planetary Science: Investigations 9-10 I-Check Quiz STUDY GUIDE Name HR Date

MATHEMATICAL MODELLING TO PREDICT THE RESIDUAL STRESSES INDUCED IN MILLING PROCESS

UDK : ISSN Original scientific article/izvirni znanstveni ~lanek MTAEC9, 46(5)471(2012)

Heat Transfer Studies on Structured Metal Sheets

Burner Tubing Specification for the Turbulent Ethylene Non-Premixed Jet Flame

EVERLIGHT ELECTRONICS CO.,LTD. Technical Data Sheet High Power LED 1W (Preliminary)

Supplementary Figure S1. AFM characterizations and topographical defects of h- BN films on silica substrates. (a) (c) show the AFM height

Electromagnetic Radiation and Scientific Instruments. PTYS April 1, 2008

Transient Thermal Measurement and Behavior of Integrated Circuits

AS 101: Day Lab #2 Summer Spectroscopy

Chapter 8. Spectroscopy. 8.1 Purpose. 8.2 Introduction

Supporting Information:

Respondence of Sample Temperature during Straight-Line Ion Implantation

high energy state for the electron in the atom low energy state for the electron in the atom

Technical Data Sheet Top View LEDs

ASTR 2310: Chapter 6

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

hf = E 1 - E 2 hc = E 1 - E 2 λ FXA 2008 Candidates should be able to : EMISSION LINE SPECTRA

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

Introduction to Blackbody Sources

Introduction to Infrared Radiation.

Name: Partner(s): 1102 or 3311: Desk # Date: Spectroscopy Part I

Taguchi-grey relational based multi response optimization of electrical process parameters in electrical discharge machining

In-Line Inspection of Hot-Rolled Steel Billets by Heat Flux Thermography

FACTORS AFFECTING IN-LINE PHASE CONTRAST IMAGING WITH A LABORATORY MICROFOCUS X-RAY SOURCE

Measurement method for the proficiency testing program

Calibration capabilities at PTB for radiation thermometry, quantitative thermography and emissivity

Material Analysis Technology R&D Efforts

Emissivity: Understanding the difference between apparent and actual infrared temperatures

Flame Spread and Extinction over Thermally Thick PMMA in Low Oxygen Concentration Flow

Influence of surface roughness on thermography measurement

Taking Fingerprints of Stars, Galaxies, and Other Stuff. The Bohr Atom. The Bohr Atom Model of Hydrogen atom. Bohr Atom. Bohr Atom

Transcription:

UDK 544.344.016.2:543.572.3:681.7.015.2 ISSN 1580-2949 Original scientific article/izvirni znanstveni ~lanek MTAEC9, 52(3)323(2018) Z. LANC et al.: EMISSIVITY OF ALUMINIUM ALLOY USING INFRARED THERMOGRAPHY TECHNIQUE 323 327 EMISSIVITY OF ALUMINIUM ALLOY USING INFRARED THERMOGRAPHY TECHNIQUE EMISIVNOST ALUMINIJEVE ZLITINE Z UPORABO INFRARDE^E TERMOGRAFIJE Zorana Lanc, Branko [trbac, Milan Zeljkovi}, Aleksandar @ivkovi}, Miodrag Had`istevi} University of Novi Sad, Faculty of Technical Sciences, Department for Production Engineering, Trg Dositeja Obradovi}a 6, Novi Sad, Serbia zoranalanc@uns.ac.rs Prejem rokopisa received: 2017-09-19; sprejem za objavo accepted for publication: 2017-11-23 doi:10.17222/mit.2017.152 Experimental determination of the emissivity of aluminum alloy Al 6082 depends on the surface roughness and temperature. The authors conducted an investigation on aluminum workpieces with different degrees of surface roughness during a continuous-cooling process, using the infrared thermography technique (ITT). The results obtained showed that the emissivity of the examined alloy increases with a larger surface roughness and decreases during the cooling process, its value ranging from 0.09 to 0.24. It was concluded that the surface roughness has a greater influence on the increase of the emissivity at higher temperatures, which can be seen in three-dimensional infrared images (3D IR). Multiple-regression analysis confirmed a strong correlation between the examined parameters and the emissivity, and an original multiple-regression model was determined. Keywords: emissivity, aluminium alloy, infrared thermography technique (ITT), three-dimensional infrared images (3D IR), regression analysis Eksperimentalno dolo~anje emisije aluminijeve zlitine Al 6082 glede na hrapavost in temperaturo povr{ine. Avtorji so izvedli raziskavo na aluminijastih obdelovancih z razli~nimi stopnjami hrapavosti povr{ine med postopkom neprekinjenega hlajenja in z uporabo infrarde~e termografije (ITT). Dobljeni rezultati so pokazali, da se emisija preizku{ane zlitine pove~a z ve~jo povr{insko hrapavostjo in se med procesom hlajenja zmanj{a, njena vrednost pa se giblje med 0,09 in 0,24. Pri vi{jih temperaturah ima hrapavost ve~ji vpliv na pove~anje emisij. Kar lahko vidimo na tridimenzionalnih infrarde~ih slikah (3D IR). Ve~kratna regresijska analiza je potrdila mo~no korelacijo med preiskovanimi parametri in emisivnostjo. Dolo~en je bil ve~kratni regresijski model. Klju~ne besede: emisivnost, aluminijeva zlitina, infrarde~a termografija (ITT), tridimenzionalne infrarde~e slike (3D IR), regresijska analiza 1 INTRODUCTION The use of the infrared thermography technique (ITT) for a non-contact temperature measurement has rapidly increased in the recent years in all areas where changes in the temperature reflect the quality and state of a product or a process. 1,2 The ITT works on the principle of the transformation of spatial variations in the emitted infrared radiation from the surface of an observed object into a two-dimensional infrared (IR) image, where the differences in temperature distribution are presented as a range of colors or tones. 3 The practical use of the ITT, however, has its limitations due to the emissivity of the observed body. 4 The emissivity represents the ability of a body to absorb and emit heat. It depends on numerous factors such as the type of material, surface roughness, microstructure, temperature, wavelength, etc. 5 Many authors investigated the effect of the mentioned parameters on the emissivity characteristics of materials, mainly metals and their alloys due to their low and varying emissivity. F. Zhang et al. 6 determined the emissivity of pure titanium TA1, oxidized nickel and austenitic stainless steel by means of a special measuring apparatus using a monochromator with a diffraction grating. With the investigated range of wavelengths of 0.8 2.2 μm and temperature range of 200 1000 C, it was shown that the emissivity of the examined metals slightly falls with an increase in the wavelength and rises with an increase in the temperature. B. Kong et al. 7 analyzed the emissivity of nickel super alloy GH536 and five aeronautical alloys using a Fourier-transform infrared-spectroscopy spectrometer at wavelengths of 1 5 μm and a temperature range of 127 927 C. The investigation showed that the emissivity of the examined alloys rises with an increase in the temperature and falls with an increase in the wavelength, while oxidation and flame treatment increase the emissivity. C. D. Wen et al. 8 used multispectral radiation thermometry (MRT) to determine the emissivity of different aluminum alloys depending on the temperature, surface roughness and oxidation. 8 The emission spectra of different alloys were similar in shape at the same temperature, but oxidation led to significant differences in the magnitude. An increase in the temperature and surface roughness mostly resulted in a higher emissivity of the examined alloys. 9,10 While the previously mentioned investigations showed that the emissivity increases with the increase in the temperature and surface roughness during heating, Materiali in tehnologije / Materials and technology 52 (2018) 3, 323 327 323

this paper includes an investigation into the emissivity behavior of an aluminum alloy during a continuous-cooling process using ITT. The reason for this is the constancy of the factors, which influence the emissivity, especially the surface conditions of a measured workpiece and similar heating and cooling rates of metals. Three-dimensional infrared images (3D IR) were used in a more detailed analysis of the effects of the surface roughness and temperature on the emissivity characteristics of metals. This study considered the possibility of using a multiple-regression analysis for the theoretical determination of the emissivity, on the basis of the experimentally obtained data. In the frame of this study, we investigated the influence of the surface roughness and temperature on the emissivity of metals with the aim of checking whether the ITT can be used for a reliable temperature measurement of heated metal surfaces on the work equipment and, by implication, for an assessment of the risk of burn injuries. 2 EXPERIMENTAL PART The experimental determination of the emissivity was conducted on the aluminum alloy Al 6082. Its mechanical properties are optimal for machining and metalworking; it has high thermostability and corrosion resistance. For the purpose of the experimental work, four workpieces were made with dimensions of (150 150 10) mm. The first workpiece was ground, whereas the other three were milled in different regimes of face milling with the aim of obtaining different surface qualities, i.e., roughness values. The roughness of the workpieces was measured with a contact method using a Mar Surf PS1 device. The mean roughness (roughness average, R a ) was measured in 30 points uniformly distributed on the surface of the workpiece. The average value of the measured roughness (Ra) was taken as the surface roughness of the workpiece (Table 1). 0 to 1 until the temperature on the IR camera and the reference temperature are equal. 11 For the purpose of this paper a heat-treat furnace was used for heating the workpieces. For achieving a uniform temperature distribution on the target area of the sample, every workpiece was placed upright in the center of the furnace and tested separately. The radiation emitted from the heat furnace can affect the thermography test to a large extent, especially for alloy Al 6082 due to its high reflectance. Thus, prior to the measurement, a 2-mm black tin box was placed into the furnace in order to eliminate the effect of the furnace walls on the measurement results. The infrared camera used for thermal imaging was camera IR ThermoPro TP8S with a spectral range of 8 14 μm and temperature accuracy of ±1 C. The reference temperature was measured using type-k thermocouples. Two thermocouples were placed on the back surface of the workpiece, whereas the third thermocouple was attached to the front surface of the workpiece using black rubber. The experimental set-up is presented in Figure 1. After installing the thermocouples and setting the IR camera, a workpiece was heated up to 200 C. Having reached this temperature, the workpiece was being cooled down to the ambient temperature of 25 C. At the same time, the camera took an IR image of the workpiece at every drop of 10 C. The described procedure was repeated for every workpiece. The obtained IR images were processed using the Guide Ir Analyser program where the average emissivity of a workpiece was adjusted to a value from 0 to 1 until the temperature became equal to the reference temperature. During the IR-image processing, the temperature used as the reference temperature was the average of the temperature values obtained with the thermocouples. The described method was used for determining the emissivity of all four workpieces at temperatures from 50 C to 200 C. Table 1: Surface roughness of the workpieces Type of Roughness (average) machining Ra (μm) Label grinding 1.07 A 1 1.25 A 2 milling 1.55 A 3 1.77 A 4 The usual method for determining the emissivity by means of an infrared (IR) camera is based on simultaneous heating of a workpiece, measuring the temperature by means of an IR camera and measuring the reference temperature on the analyzed surface. The reference temperature can be measured by means of a contact device for temperature measurement or by applying a special coating with the known emissivity to the examined surface within the field view of the IR camera. The emissivity is determined by adjusting the value from Figure 1: Experimental set-up 324 Materiali in tehnologije / Materials and technology 52 (2018) 3, 323 327

3 RESULTS AND DISCUSSION Z. LANC et al.: EMISSIVITY OF ALUMINIUM ALLOY USING INFRARED THERMOGRAPHY TECHNIQUE The experimental data show that the average emissivity of aluminium alloy Al 6082 in the spectral range of 8 14 μm decreases during the cooling and mainly increases with an increase in the surface roughness (Figure 2). The emissivity ranges from 0.09 to 0.24. At temperatures from 50 C to 80 C, the emissivity values of the workpieces are constant, and their mutual differences are only the results of the surface roughness. At temperatures higher than 80 C, the emissivities rise, first with the A 3 workpiece and last with the A 4 workpiece. The emissivity of the ground workpiece A 1 is the lowest and not prone to drastic changes as in the case of the other workpieces, which were milled. 3.1 Three-dimensional infrared images A more through investigation into the effects of the temperature and surface roughness on the emissivity was conducted using 3D IR images. 3D IR images are a three-dimensional representation of the surface of a workpiece with more strictly defined boundaries between the areas with small temperature differences that are almost invisible in a normal IR image. There are various commercial programs for the construction of 3D IR images, but in this paper, a new, original and simple method is presented. The method is based on exporting the temperature values per pixel of an IR image using the Guide Ir Analyser program into a Microsoft Excel table. In the table, the data are grouped in such a way that the x and y coordinates determine the position of a pixel in the IR image, whereas the z coordinate determines its temperature. With a simple selection of all the data and the construction of a surface-contour diagram in Microsoft Excel, 3D IR images are obtained. Figure 3 represents 3D IR images of the ground workpiece A 1 and the workpiece with the greatest surface roughness, A 4, at 200 C. Their comparison shows that the temperature is more evenly distributed in the A 1 workpiece due to a more even surface roughness. While Figure 3: 3D IR images of A 1 workpiece at 200 C (left) and A 4 workpiece at 200 C (right) measuring the arithmetic mean roughness by means of the Mar Surf PS1 device, it was noticed that the left side of the A 1 workpiece had a greater roughness than the right side, whereas in the A 4 workpiece, the opposite was true. These data correspond to the presented 3D IR images of the workpieces. Although the average temperature of both workpieces was 200 C, in the A 1 workpiece, the temperatures from 210 C to 230 C were more frequent than in the A 4 workpiece where the most frequent temperatures ranged from 230 C to 250 C. Plate defects contributed to the higher temperature of the A 4 workpiece. The defects are clearly visible in Figure 4 and are represented with red areas, which correspond to the highest temperatures. Apart from this, in the A 4 workpiece, an area of low temperatures ranging from 170 C to 190 C was observed, which is, at the same time, the area with the lowest roughness of the workpiece. In Figure 3, the temperature of black rubber is above 350 C although its real temperature is 200 C. This error occurred because it is possible to adjust only one value of the emissivity in a 3D IR image. In this case, the values of the emissivity were adjusted for the A 1 and A 4 workpieces, which is why the temperatures of black rubber drastically increased. The effect of reflected radiation on the bottom part of the workpiece is noticeable here as well, leading to the so-called false temperatures. The analysis of the 3D IR images of the workpieces A 2 and A 3 showed similarities in the temperature distribution, with clearly visible scratches and the milling direction on the surface, as represented in Figure 4. At higher temperatures, the differences in the surface roughness are more conspicuous than at lower temperatures. In the 3D IR images of the milled workpieces, the difference in the surface roughness is bigger at the temperature of 200 C than at the temperature of 50 C. At Figure 2: Emissivity of aluminium alloy Al 6082 at low and middle temperatures Figure 4: 3D IR images of A 3 workpiece at the temperatures of 200 C (left) and 50 C (right) Materiali in tehnologije / Materials and technology 52 (2018) 3, 323 327 325

higher temperatures, the milling direction and the boundaries between tool passes are more conspicuous, which can be seen in the 3D IR images of the A 3 workpiece whose surface was machined in three tool passes (Figure 4). This leads to a conclusion that the surface roughness causes a greater increase in the emissivity at higher temperatures. 3.2 Multiple-linear-regression analysis A multiple-regression analysis makes it possible to examine the effects of several independent variables on the dependent output variable. The result of this approach is a multiple-regression model that, in the form of a mathematical formula, connects the effects of two independent variables on a dependent variable. 12 In our case, the dependent variable the emissivity ( ) is related to two independent variables the temperature (T) and the surface roughness (R a ) using the following model (Equation 1): = 0 + 1 T + 2 Ra + r (1) Where 0, 1, 2 represent regression coefficients and r is the component of random error. For the assessment of the model for n=64observations and the number of independent variables k =2, the matrix form of Equation 1 is given by matrix Equation (2): e x x 1 1 11 12 r1 e 1 x x 2 21 22 2 Y = ; X = ; = r ; = (2) e 1 x( 64 ) 1 x ( 64) 2 r 64 Matrix Equation (2) is solved in line with the results from the following multiple-linear-regression model: = 0. 000521 T + 0. 08635 R a 0. 052 (3) The presented model can be used for the temperature range of 50 200 C and surface roughness of 1.07 1.77 μm. In this case, the multiple coefficient of determination R 2 shows that 80.94 % of the variation in the emissivity comes from the variation in the temperature and surface roughness, whereas the remaining 19.06 % is the consequence of the effects of the other parameters such as humidity, permeability of the atmosphere, temperature of the environment, etc. The model can be used for predicting the value of the emissivity at the temperatures and surface-roughness values beyond the mentioned ranges, with a somewhat lower coefficient of determination R 2 pred of 78.68 %. Multiple regression was used to determine the strength of the dependence between the emissivity and the observed parameters based on the correlation coefficient r. The correlation coefficient was 0.9, pointing to the fact that there is a strong (direct) linear dependence between the temperature and surface roughness and the emissivity. 64 4 CONCLUSIONS The emissivity of aluminium alloy Al 6082 was experimentally determined in the process of cooling from 200 C to 50 C, using the infrared thermography technique. The investigation showed that the emissivity of the chosen alloy ranges from 0.09 to 0.24, that it decreases with a decrease in the temperature and increases with an increase in the surface roughness. At higher temperatures, the differences between the emissivity values of the workpieces are bigger. The analysis of 3D IR images showed that this phenomenon is a consequence of a more significant effect of the surface roughness on the emissivity at higher temperatures. Additionally, the paper presents a new method of creating 3D IR images using Microsoft Excel. This method is simple and, unlike commercial programs, it is more affordable. Although the ITT is not recommendable for precise determinations of the emissivity of metals, in the post-processing of the IR images, the authors managed to determine small variations in the emissivity, even when the differences between the IR images were 10 C. Multiple-regression analysis confirmed a strong correlation between the investigated parameters and the emissivity, and a multiple-regression model was determined. The presented model can only be applied with low and medium temperatures since at higher temperatures, there is a somewhat greater deviation of the experimental data from the regression line. The reason for this is an uneven distribution of temperature on the surface of a workpiece due to the defects that occurred during the machining. 5 REFERENCES 1 L. Michalski, K. Eckersdorf, J. Kucharski, J. McGhee, Temperature Measurement, Wiley & Sons, Ltd., Chichester, 2001 2 B. Kosec, B. Karpe, I. Budak, M. Li~en, M. \or evi}, A. Nagode, G. Kosec, Efficiency and quality of inductive heating and quenching of planetary shafts, Metallurgy, 51 (2012) 1, 71 74 3 H. Glava{, L. Jozsa, T. Bari}, Infrared thermography in energy audit of electrical installations, Tehn. vjesn., 23 (2016) 5, doi:10.17559/ tv-20150702185559 4 P. Schreivogel, M. Pfitzner, Optical convective heat transfer measurements using infrared thermography and frequency domain phosphor thermometry, Int. J. Heat Mass Transf., 82 (2015), doi:10.1016/j.ijheatmasstransfer.2014.11.025 5 M. [vantner, P. Honnerová, Z. Veselý, The influence of furnace wall emissivity on steel charge heating, Infrared Phys. Technol., 74 (2016), 63 71, doi:10.1016/j.infrared.2015.12.001 6 F. Zhang, K. Yu, K. Zhang, Y. Liu, K. Xu, Y. Liu, An emissivity measurement apparatus for near infrared spectrum, Infrared Phys. Technol., 73 (2015), 275 280, doi:10.1016/j.infrared.2015.10.001 7 B. Kong, T. Li, Q. Eri, Normal spectral emissivity of GH536 (HastelloyX) in three surface conditions, Appl. Therm. Eng., 113 (2017), doi:10.1016/j.applthermaleng.2016.11.022 8 C. D. Wen, I. Mudawar, Emissivity characteristics of roughened aluminum alloy surfaces and assessment of multispectral radiation thermometry (MRT) emissivity models, Int. J. Heat Mass Transf., 47 (2004), doi:10.1016/j.ijheatmasstransfer.2004.04.025 326 Materiali in tehnologije / Materials and technology 52 (2018) 3, 323 327

9 B. Kosec, G. Kosec, Temperature field analysis on active working surface of the die-casting die, Metall., 57 (2003) 3, 134 136 10 C. D. Wen, I. Mudawar, Modeling the effects of surface roughness on the emissivity of aluminum alloys, Int. J. Heat Mass Transf., 49 (2006), doi:10.1016/j.ijheatmasstransfer.2006.04.037 11 M. [vantner, P. Vacíková, M. Honner, Non-contact charge temperature measurement on industrial continuous furnaces and steel charge emissivity analysis, Infrared Phys. Technol., 61 (2013), doi:10.1016/ j.infrared.2013.07.005 12 A. R. Motorcu, Y. Isik, A. Kus, M. C. Cakir, Analysis of the cutting temperature and surface roughness during the orthogonal machining of AISI 4140 alloy steel via the Taguchi method, Mater. Tehnol., 50 (2016) 3, doi:10.17222/mit.2015.021 Materiali in tehnologije / Materials and technology 52 (2018) 3, 323 327 327