Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07

Similar documents
Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13

Fabric REFLECTACOUSTIC

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32

Roller blind fabric PRIMACOUSTIC R

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04

Curtain fabric type Ace Manufacturer Kvadrat A/S

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

Fabric XPRESS + PU-foam Manufacturer Gabriel A/S

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Renolit stretch ceilings

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt

Fabric RUNNER Manufacturer Gabriel A/S

Fabric HUSH Manufacturer Gabriel A/S

Fabric EVENT SCREEN Manufacturer Gabriel A/S

Fabric XPRESS Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S

Sound insulation of planted noise barriers

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

TFI Report Sound Absorption Impact Sound Insulation

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

TFI Report Sound Absorption Impact Sound Insulation

Testing Procedure: AS ISO

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

TFI Report Sound Absorption Impact Sound Insulation

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

Measurement of sound absorption coefficient for Fraster felt SpaceCover

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of curtains, manufacturer Vescom BV

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

Measurement of Acoustic Properties of light weight concrete SL-Deck

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

REPORT N CR

TFI Report Sound Absorption Impact Sound Insulation

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor

Report. P.O. Box 70 NL 5700 AB Deurne The Netherlands Report number: A E-RA Date: 12 februari 2014 TS/TS/JW/A E-RA

Laboratory for Acoustics

Report. Laboratory for Acoustics

Calcul des coefficients d'absorption alpha sabine

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

Consultancy Report Ref: 9383-R01

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant:

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

A L I O N Technical Center. Test Report

RIVERBANK ACOUSTICAL LABORATORIES

ISO 354 INTERNATIONAL STANDARD. Acoustics Measurement of sound absorption in a reverberation room

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

Summary. The basic principles of the simulation technique SERT

RIVERBANK ACOUSTICAL LABORATORIES

Report. Laboratory for Acoustics Determination of the sound absorption (reverberation room method) of different wired mats, manufacturer Rockwool

REPORT. Client. Test object. Date of testt. Results. Rönnåsgatan 5B Ulricehamn. (7 appendices) content of the

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

Paseo Recoletos, nº Madrid TEST REPORT

Sound Absorption Test Intertek. kraft paper softwall + softblock modular system. m o l o d e s i g n, l t d

Laboratory for Acoustics

Development of a small-scale reverberation room

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

ISO INTERNATIONAL STANDARD

Certificate Sound reduction of building elements

Report. Laboratory for Acoustics

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex

Micro-perforated sound absorbers in stretched materials

Modeling Measurement Uncertainty in Room Acoustics P. Dietrich

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

Technical Note. Measurement of Sound Absorption for Flex Acoustics AqTube. Performed for Flex Acoustics. TC Project no.: T Page 1 of 7

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

TFI Report Impact Sound Insulation

ISO INTERNATIONAL STANDARD

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION

Witold MIKULSKI. Central Institute for Labour Protection National Research Institute Czerniakowska 16, Warszawa, Poland;

Evaluation of standards for transmission loss tests

TFI Report Impact Sound Insulation

Part 2: Methods for special reverberation test rooms

Benefits of Reduced-size Reverberation Room Testing

VK2 volume flow controller Overview

Design and Acoustics Brought into Harmony

ISO 3741 INTERNATIONAL STANDARD

Basic Study on a Laboratory Measurement Method of the Normal-Incidence Scattering Coefficient

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements.

A suggested method to be used to measure scattering coefficients of full scale samples.

Laboratory and In Situ Sound Absorption Measurement under a Synthetized Diffuse Acoustic Field: a Case Study on Five Materials

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

INVESTIGATIONS INTO THE PERFORMANCE OF THE REVERBERATION CHAMBER OF THE INTEGRATED ACOUSTICS LABORATORY. A Thesis Presented to The Academic Faculty

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8

Gesellschaft für Akustikforschung Dresden mbh Acoustic Engineering Dresden AED Acoustic Measuring Instruments & Analysis Software

COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE

Using an ambisonic microphone for measurement of the diffuse state in a reverberant room

Transcription:

Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.de Dipl.-Ing. (FH) Eva Müller Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com 2014-08-05 Fabric Zetacoustic Measurement of sound absorption in a reverberation room according to EN ISO 354 Test Report No. M102794/07 Client: Consultant: Création Baumann AG Bern-Zürichstrasse 23 CH 4901 Langenthal Date of report: 2014-08-05 Delivery date of test objects: 2014-06-30 Date of measruement: 2014-07-18 Total number of pages: Certified quality management system according to ISO 9001 Accredited testing laboratory according to ISO/IEC 17025 Dipl.-Ing. (FH) Eva Müller In total 14 pages: 6 pages copy, 2 pages Appendix A, 1 page Appendix B and 5 pages Appendix C. Müller-BBM GmbH HRB Munich 86143 VAT Reg. No. DE812167190 Managing directors: Joachim Bittner, Walter Grotz, Dr. Carl-Christian Hantschk, Stefan Schierer, Elmar Schröder, Norbert Suritsch

Table of contents 1 Task 3 2 Basis 3 3 Test object and test assembly 3 3.1 Test object 3 3.2 Test assembly 4 4 Execution of the measurements 5 5 Evaluation 5 6 Measurement results 5 7 Remarks 6 Appendix A: Appendix B: Appendix C: Test certificates Photographs Description of test method, test facility and test equipment 2014-08-05 Page 2

1 Task On behalf of the company Création Baumann AG, CH 4901 Langenthal, the sound absorption of the fabric type Zetacoustic had to be measured according to EN ISO 354 [1] in the reverberation room. The fabric was tested in a flat and a folded arrangement with a distance of 150 mm to the reflective wall. 2 Basis This test report is based on the following documents: [1] EN ISO 354: Acoustics - Measurement of sound absorption in a reverberation room. 2003-05 [2] EN ISO 11654: Acoustics Sound absorbers for use in buildings Rating of sound absorption. 1997-04 [3] ISO 9613-1: Acoustics; Attenuation of sound during propagation outdoors; part 1: calculation of the absorption of sound by the atmosphere. 1993-06 [4] ASTM C 423-09a: Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method. Revision: 09a. 2009-10 [5] EN 29053: Acoustics Materials for acoustical applications Determination of airflow resistance. 1993-03 3 Test object and test assembly 3.1 Test object The tested material is described by the manufacturer as follows: - manufacturer Création Baumann - type Zetacoustic - material 100 % PLF Trevira CS The testing laboratory has measured as follows: - thickness: t = 0.39 mm - air flow resistance acc. to EN 29053 [5]: R S = 212 Pa s/m - area specific mass: m" = 131 g/m² 2014-08-05 Page 3

3.2 Test assembly The installation of the test objects was carried out by employees of the test laboratory at the reverberation room of Müller-BBM. The test object was installed in a flat (G-150) and a folded arrangement. The mounting details are as follows: - distance to the wall 150 mm - fixed directly underneath the ceiling, suspended from a metal rail, height 50 mm - construction without enclosing frame - fabric arranged with front side acc. to manufacturer s mark towards the reverberation room The mounting details for the tested arrangements are as follows: a) flat arrangement G-150 - mounting type G-150 according to EN ISO 354 [1] section 6.2.1 and appendix B.5 of EN ISO 354 [1] - test object assembled and sewn by the manufacturer width x height = 3.63 m x 3.00 m - total dimensions of the test surface (starting at the lower border of the metal rail): width x height = 3.63 m x 2.95 m = 10.71 m 2 b) folded arrangement - 100 % folded - test object assembled and sewn by the manufacturer width x height = 7.25 m x 3.00 m - total dimensions of the test surface (starting at the lower border of the metal rail): width x height = 3.63 m x 2.95 m = 10.71 m 2 The photographs in Appendix B show details of the test arrangements. 2014-08-05 Page 4

4 Execution of the measurements The measurements were executed and evaluated according to EN ISO 354 [1]. The test procedure, the test stand and the test equipment used for the measurements are described in Appendix C. 5 Evaluation The sound absorption coefficient α S was determined in one third-octave bands between 100 Hz and 5000 Hz according to EN ISO 354 [1]. In addition to the sound absorption coefficients the following characteristic values were determined according to EN ISO 11654 [2]. - Practical sound absorption coefficient α p in octave bands - Weighted sound absorption coefficient α w as single value The weighted sound absorption coefficient α w is determined from the practical sound absorption coefficients α p in the octave bands of 250 Hz to 4000 Hz. According to ASTM C 423-09a [4] the following characteristic values were determined: - noise reduction coefficient NRC as single value: Arithmetical mean value of the sound absorption coefficients in the four onethird-octave-bands 250 Hz, 500 Hz, 1000 Hz and 2000 Hz; mean value rounded to 0.05 - sound absorption average SAA as single value: Arithmetical mean value of the sound absorption coefficients in the twelve onethird-octave-bands between 250 Hz and 2500 Hz; mean value rounded to 0.01 6 Measurement results The sound absorption coefficients α S in one third-octave bands, the practical sound absorption coefficients α p in octave bands and the single values α w, NRC and SAA are indicated in the test certificates in Appendix A. 2014-08-05 Page 5

7 Remarks The determined test results only refer to the test specimens and prevailing conditions on the day of measurements. This test report may only be published and copied as a whole including all of its appendixes. The publishing of extracts requires the prior written consent of Müller-BBM GmbH. Dipl.-Ing. (FH) Eva Müller Philipp Meistring, M. Eng. 2014-08-05 Page 6

Sound absorption coefficient ISO 354 Measurement of sound absorption in reverberation rooms Client: Création Baumann AG Bern-Zürichstrasse 23, CH - 4901 Langenthal Test specimen: ZETACOUSTIC, flat arrangement Mounting: mounting type G-150 according to ISO 354 total dimensions of the test surface: width x height = 3.63 m x 2.95 m clear distance to the wall 150 mm flat arrangement arranged without enclosing frame Material details: single layer 100% PLF Trevira CS thickness t = 0.39 mm area specific mass app. m'' = 131 g/m² air flow resistance: Rs = 212 Pa s/m Room: reverberation room E Volume: 199.60 m³ Size: 10.71 m² Date of test: 2014-07-18 θ [ C] r. h. [%] B [kpa] without specimen 23.2 57.0 95.6 with specimen 23.6 54.3 95.4 α S Frequency 1/3 octave [Hz] α p octave 100 0.01 125 0.04 0.05 160 0.07 200 0.14 250 0.21 0.25 315 0.35 400 0.47 500 0.57 0.55 630 0.58 800 0.50 1000 0.42 0.45 1250 0.45 1600 0.49 2000 0.49 0.50 2500 0.51 3150 0.54 4000 0.55 0.55 5000 0.58 Sound absorption coefficient α S 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 Equivalent sound absorption area less than 1.0 m² α S Sound absorption coefficient according to ISO 354 α p Practical sound absorption coefficient according to ISO 11654 Rating according to ISO 11654: Weighted sound absorption coefficient α w = 0.50 Sound absorption class: D MÜLLER-BBM Shiftet curve of reference values according to ISO 11654 Sound absorption coefficient 125 250 500 1000 2000 4000 Frequency f / Hz Planegg, 2014-08-05 No. of test report M102794/7 Rating according to ASTM C423: Noise Reduction Coefficient NRC = 0.40 Sound Absorption Average SAA = 0.43 Appendix A Page 1 Bau4(v1,7,0,0) - R:\BAU\Pruefst\Bau4Data\102\102794\2014-07-18\102794_2014-07-18_11.mb4: 06.08.2014

Sound absorption coefficient ISO 354 Measurement of sound absorption in reverberation rooms Client: Création Baumann AG Bern-Zürichstrasse 23, CH - 4901 Langenthal Test specimen: ZETACOUSTIC, folded arrangement Mounting: mean distance to the wall 150 mm total dimensions of the test surface: width x height = 3.63 m x 2.95 m folded arrangement (100 %) arranged without enclosing frame Material details: single layer 100% PLF Trevira CS thickness t = 0.39 mm area specific mass app. m'' = 131 g/m² air flow resistance: Rs = 212 Pa s/m Room: Hallraum E Volume: 199.60 m³ Size: 10.71 m² Date of test: 2014-07-18 θ [ C] r. h. [%] B [kpa] without specimen 23.2 57.0 95.6 with specimen 23.6 53.5 95.4 α S Frequency 1/3 octave [Hz] α p octave 100 0.07 125 0.14 0.15 160 0.18 200 0.31 250 0.36 0.40 315 0.53 400 0.61 500 0.64 0.65 630 0.67 800 0.66 1000 0.66 0.70 1250 0.71 1600 0.71 2000 0.70 0.70 2500 0.72 3150 0.75 4000 0.76 0.75 5000 0.80 Sound absorption coefficient α S 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 Equivalent sound absorption area less than 1.0 m² α S Sound absorption coefficient according to ISO 354 α p Practical sound absorption coefficient according to ISO 11654 Rating according to ISO 11654: Weighted sound absorption coefficient α w = 0.65 Sound absorption class: C MÜLLER-BBM Shiftet curve of reference values according to ISO 11654 Sound absorption coefficient 125 250 500 1000 2000 4000 Frequency f / Hz Planegg, 2014-08-05 No. of test report M102794/7 Rating according to ASTM C423: Noise Reduction Coefficient NRC = 0.60 Sound Absorption Average SAA = 0.61 Appendix A Page 2 Bau4(v1,7,0,0) - R:\BAU\Pruefst\Bau4Data\102\102794\2014-07-18\102794_2014-07-18_12.mb4: 07.08.2014

Zetacoustic, Création Baumann Figure B1. Flat arrangement: test object mounted in the reverberation room. Figure B2. Folded arrangement: test object mounted in the reverberation room. 2014-08-05 Appendix B, Page 1

Description of the test procedure for the determination of the sound absorption in a reverberation room 1 Measurand The sound absorption coefficient α of the test object was determined. For this purpose the mean value of the reverberation time in the reverberation room with and without the test object was measured. The sound absorption coefficient was calculated using the following equation: α A T S = S 1 1 A T = 55,3 V 4 V ( m2 m1 ) c2t2 c1t 1 With: α S sound absorption coefficient; A T equivalent sound absorption area of the test object in m 2 ; S area covered by the test object in m 2 ; V volume of the reverberation room in m 3 ; c 1 propagation speed of sound in air in the reverberation room without test object in m/s; c 2 propagation speed of sound in air in the reverberation room with test object in m/s; T 1 reverberation time in the reverberation room without test object in s; T 2 reverberation time in the reverberation room with test object in s; m 1 power attenuation coefficient in the reverberation room without test object in m -1 ; m 2 power attenuation coefficient in the reverberation room with test object in m -1. The different dissipation during the sound propagation in the air was taken into account according to paragraph 8.1.2 of EN ISO 354 [1]. The dissipation was calculated according to ISO 9613-1 [3]. The climatic conditions during the measurements are indicated in the test certificates. Information on the repeatability and reproducibility of the test procedure are given in EN ISO 354 [1]. 2014-08-05 Appendix C, Page 1

2 Test procedure 2.1 Description of the reverberation room The reverberation room complies with the requirements according to EN ISO 354 [1]. The reverberation room has a volume of V = 199.6 m 3 and a surface of S = 216 m 2. Six omni-directional microphones and four loudspeakers were installed in the reverberation room. In order to improve the diffusivity, six composite sheet metal boards dimensioned 1.2 m x 2.4 m and six composite sheet metal boards dimensioned 1.2 m x 1.2 m were suspended curved and irregularly. Figure C1 shows the drawings of the reverberation room. 2014-08-05 Appendix C, Page 2

Figure C1. Plan view and sections of the reverberation room. 2014-08-05 Appendix C, Page 3

2.2 Measurement of reverberation time The determination of the impulse responses were carried out according to the indirect method. In all tests, a sinusoidal sweep with pink noise spectrum was used as test signal. In the reverberation room with and without test objects each 24 independent combinations of loudspeakers and microphones were measured. The reverberation time was evaluated according to EN ISO 354 [1], using a linear regression for the calculation of the reverberation time T 20 from the level of the backward integrated impulse response. The determined reverberation times in the reverberation room with and without test object are indicated in Table C1. Table C1. Reverberation times. Reverberation time T in s frequency in Hz T 1 (without test object) T 2 (with test object) Appendix A, page 1 Appendix A, page 2 100 5.08 4.97 4.53 125 4.73 4.45 3.88 160 5.18 4.60 3.97 200 5.60 4.41 3.55 250 5.29 3.87 3.24 315 5.25 3.23 2.73 400 5.35 2.90 2.55 500 5.27 2.63 2.47 630 5.08 2.55 2.38 800 5.02 2.72 2.38 1000 5.19 3.00 2.42 1250 5.45 2.98 2.37 1600 5.41 2.86 2.37 2000 5.05 2.76 2.31 2500 4.46 2.53 2.14 3150 3.75 2.22 1.93 4000 3.01 1.93 1.69 5000 2.40 1.63 1.44 2014-08-05 Appendix C, Page 4

2.3 List of test equipment The test equipment used is listed in Table C2. Table C2. List of test equipment. Name Manufacturer Type Serial-No. Sound card RME Multiface II 22460388 Amplifier APart Champ One 09070394 Dodecahedron Müller-BBM DOD130B 265201 Dodecahedron Müller-BBM DOD130B 265202 Dodecahedron Müller-BBM DOD130B 265203 Dodecahedron Müller-BBM DOD130B 265204 Microphone Microtech M360 1783 Microphone Microtech M360 1785 Microphone Microtech M360 1786 Microphone Microtech M360 1787 Microphone Microtech M360 1788 Microphone Microtech M360 1789 Hygro-/Thermometer Testo Saveris H1E 01554624 Barometer Lufft Opus 10 030.0910.0003.9. 4.1.30 Software for measurement and evaluation Müller-BBM Bau 4 Version 1.7 2014-08-05 Appendix C, Page 5