Fabric XPRESS Manufacturer Gabriel A/S

Similar documents
Fabric RUNNER Manufacturer Gabriel A/S

Fabric HUSH Manufacturer Gabriel A/S

Fabric EVENT SCREEN Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S

Fabric XPRESS + PU-foam Manufacturer Gabriel A/S

Fabric Medley Manufacturer Gabriel A/S

Fabric TWIST MELANGE Manufacturer Gabriel A/S

Fabric REFLECTACOUSTIC

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

Fabric Umbria III R. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/13

Fabric ALEX. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/09

Fabric VELOS STRATO. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/10

Fabric Zetacoustic. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/07

Fabric UDINE. Measurement of sound absorption according to EN ISO 354. Test Report No. M102794/32

Curtain fabric type Ace Manufacturer Kvadrat A/S

Roller blind fabric PRIMACOUSTIC R

stylegreen Iceland Moss / Reindeer Moss of the company FlowerArt

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Fabric Corsica. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/16

Renolit stretch ceilings

Fabric STREAMER pro. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M111250/04

Sound insulation of planted noise barriers

TFI Report Sound Absorption Impact Sound Insulation

TFI Report Sound Absorption Impact Sound Insulation

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

TFI Report Sound Absorption Impact Sound Insulation

Acoustic test report AU01+N01

CERTIFICATE OF ACCREDITATION

TFI Report Sound Absorption Impact Sound Insulation

RIVERBANK ACOUSTICAL LABORATORIES

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

RIVERBANK ACOUSTICAL LABORATORIES

TFI Report Impact Sound Insulation

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

Independent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION. on the given range of performed tests

A L I O N Technical Center. Test Report

Independent, accredited testing station Member laboratory of STL and LOVAG TEST CONFIRMATION. on the given range of performed tests

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

Tests on glasswool air conditioning duct according to EN Pressure losses tests

Inspection Report. Coating name: IGP DURA xal IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

REPORT issued by an Accredited Testing Laboratory

TFI Report Impact Sound Insulation

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

Measurement of sound absorption coefficient for Fraster felt SpaceCover

Collector test according to EN ,2:2002

Gesellschaft für Akustikforschung Dresden mbh Acoustic Engineering Dresden AED Acoustic Measuring Instruments & Analysis Software

Analytische Qualitätssicherung Baden-Württemberg

Testing Procedure: AS ISO

Report. Laboratory for Acoustics

Testing of Lincolnshire Limestone. Prepared for: Phil Kerry Goldholme Stone Ltd. Irnham Grange Irnham Road Corby Glen Grantham Lincolnshire NG 33 4 NE

REPORT N CR

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

SAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0

Technical Report. Project. The Laboratory Determination of The Random Incidence sound Absorption Coefficient of VertiQ Panels.

REPORT issued by an Accredited Testing Laboratory

REPORT OF SPECIAL TEST

Test Report EN (2008)

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

Measurement of Acoustic Properties of light weight concrete SL-Deck

Analytische Qualitätssicherung Baden-Württemberg

UN Regulation No. 118 Annex 8

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

Collector test according to EN ,2 : 2006

CERTIFICATE OF CALIBRATION

STATUS OF THE WIGOS DEMONSTRATION PROJECTS

473-SHX Dew Point Mirror

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

Test of resistance to wind load under dynamic wind load. Roller shutter with built-in box, inspection from inside and foamed aluminium laths

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

Test Report ROMA USA LLC. Product Emissions of Furniture in accordance with. Cradle to Cradle section 5.8 ECODOMUS SATIN BASE TR.

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

Testing of Ancaster Limestone. Prepared for: Phil Kerry Goldholme Stone Ltd. Irnham Grange Irnham Road Corby Glen Grantham Lincolnshire NG 33 4 NE

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex

Collector test according to EN ,2:2006

Benefits of Reduced-size Reverberation Room Testing

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

Report. P.O. Box 70 NL 5700 AB Deurne The Netherlands Report number: A E-RA Date: 12 februari 2014 TS/TS/JW/A E-RA

Laboratory for Acoustics. Determination of the sound absorption (reverberation room method) of Airpanel, manufacturer Texdecor

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

1 / 17. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

Appendix B1. Reports of SMU

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

Certificate Sound reduction of building elements

Collector test according to EN ,2:2006

Report. Laboratory for Acoustics

Report TAG3-UA-1212-E07 Testing of the transmission and the g-value of a polycarbonate multiwall panel AKYVER 16/7 IR Control Grey

REPORT NUMBER: GZU -001 ORIGINAL ISSUE DATE:

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen

Certificate of Accreditation to ISO/IEC 17025:2005

The information included in the following report presents the results of sound pressure and sound power testing.

Transcription:

Müller-BBM GmbH Robert-Koch-Str. 11 82152 Planegg bei München Telephone +49(89)85602 0 Telefax +49(89)85602 111 www.muellerbbm.com Telephone +49(89)85602 3206 Eva.Mueller@mbbm.com 2015-03-03 M104146/18 MRE/STY Fabric XPRESS Manufacturer Gabriel A/S Determination of the airflow resistance according to EN 29053 Test Report No. M104146/18 Client: Consultant: Gabriel A/S Hjulmagervej 55 9000 Aalborg Denmark Date of report: 2015-03-03 Delivery date of test objects: 2015-01-28 Date of test: 2015-02-09 Total number of pages: Certified quality management system according to ISO 9001 Accredited testing laboratory according to ISO/IEC 17025 In total 9 pages: 4 pages text, 3 pages Appendix A and 2 pages Appendix B. Müller-BBM GmbH HRB Munich 86143 VAT Reg. No. DE812167190 Managing directors: Joachim Bittner, Walter Grotz, Dr. Carl-Christian Hantschk, Stefan Schierer, Elmar Schröder, Norbert Suritsch

Table of contents 1 Task 3 2 Basics 3 3 Test objects 3 4 Execution of measurements 3 5 Measurement results 4 6 Remarks 4 Appendix A: Appendix B: Measurement results and evaluation List of test equipment M104146/18 MRE/STY 2015-03-03 Page 2

1 Task On behalf of Gabriel A/S, DK 9000 Aalborg, the airflow resistance of three samples of the fabric type XPRESS was to be determined according to EN 29053 [1]. 2 Basics This test report is based on the following document: [1] EN 29053: Acoustics Materials for acoustical applications Determination of airflow resistance. 1993 3 Test objects The tested fabric is described in table 1. The indicated characteristic values were determined by the testing laboratory on the basis of the sample. Table 1. Test object. Test object (manufacturer s information) Area specific mass m [g/m²] Thickness d [mm] Appendix A, page Sample 1: fabric type XPRESS, manufacturer Gabriel A/S material: polyester and PU Sample 2: fabric type XPRESS, manufacturer Gabriel A/S material: polyester and PU 367 4.7 1 367 4.8 2 Sample 3: fabric type XPRESS, manufacturer Gabriel A/S material: polyester and PU 4 Execution of measurements 369 4.8 3 The airflow resistance was determined according to EN 29053 [1]. The test method, the test facility and the test equipment used are described in Appendix B. M104146/18 MRE/STY 2015-03-03 Page 3

5 Measurement results For the tested fabric type XPRESS a specific airflow resistance of was determined. R s = 107 Pa s/m The determined air flow resistances of each of the three samples are shown in table 2. The measurement results are shown in diagrams and tables in the test certificate in Appendix A of this report. Table 2. Determined airflow resistances of the fabric XPRESS. Test object Airflow resistance R s [Pa s/m] Appendix A, page Sample 1: fabric type XPRESS Sample 2: fabric type XPRESS Sample 3: fabric type XPRESS 111 1 111 2 100 3 6 Remarks The test results exclusively relate to the investigated subjects and conditions described. Dipl.-Ing (FH) Eva Müller Dipl.-Ing. (FH) Dominik Reif This test report may only be published, shown or copied as a whole, including its appendices. The publishing of excerpts is only possible with prior consent of Müller-BBM. M104146/18 MRE/STY 2015-03-03 Page 4

EN 29053 Determination of airflow resistance Client: Gabriel A/S Hjulmagervej 55 9000 Aalborg, Denmark Project No.: M104146 Mueller-BBM Probe No.:10066 Test object: fabric Xpress + 5 mm foam, sample no. 01 colour: 60008 composition: polyester and PU Diameter: 100 mm Thickness: 4.7 mm Area-specific mass: 367 g/m 2 m ars 1.2.5253.15707 - \\s-muc-fs01\allefirmen\m\proj\104\m104146\marsdata\2015-02-09\2015-02-09_xpress\2015-02-09_express-foam_01.mrs (24.03.2015) Barometric pressure: B = 96,2 kpa Temperature: θ = 21,8 C Relative humidity: r. h. = 11,4 % u/ R s / (mm/s) (Pa s/m) 3.41 111 4.87 111 6.33 111 7.78 111 9.24 110 10.70 111 12.16 111 13.61 111 Airflow resistance R s /(Pa s/m) 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 0,0 2,5 5,0 7,5 10,0 12,5 15,0 Airflow velocity u/(mm/s) Airflow resistance R s = 111 Pa s/m Laboratory: Responsible: Date: Planegg 2015/03/03 2015-03-03 Appendix A, Page 1

EN 29053 Determination of airflow resistance Client: Gabriel A/S Hjulmagervej 55 9000 Aalborg, Denmark Project No.: M104146 Mueller-BBM Probe No.:10067 Test object: fabric Xpress + 5 mm foam, sample no. 02 colour: 60008 composition: polyester and PU Diameter: 100 mm Thickness: 4.8 mm Area-specific mass: 367 g/m 2 m ars 1.2.5253.15707 - S:\M\Proj\104\M104146\MarsData\2015-02-09\2015-02-09_Xpress\2015-02-09_Express-Foam_02.mrs (24.03.2015) Barometric pressure: B = 96,2 kpa Temperature: θ = 21,9 C Relative humidity: r. h. = 10,7 % u/ R s / (mm/s) (Pa s/m) 4.87 111 6.33 110 7.79 111 9.25 111 10.71 110 12.16 111 13.62 110 Airflow resistance R s /(Pa s/m) 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 0,0 2,5 5,0 7,5 10,0 12,5 15,0 Airflow velocity u/(mm/s) Airflow resistance R s = 111 Pa s/m Laboratory: Responsible: Date: Planegg 2015/03/03 2015-03-03 Appendix A, Page 2

EN 29053 Determination of airflow resistance Client: Gabriel A/S Hjulmagervej 55 9000 Aalborg, Denmark Project No.: M104146 Mueller-BBM Probe No.:10068 Test object: fabric Xpress + 5 mm foam, sample no. 03 colour: 60008 composition: polyester and PU Diameter: 100 mm Thickness: 4.8 mm Area-specific mass: 369 g/m 2 m ars 1.2.5253.15707 - S:\M\Proj\104\M104146\MarsData\2015-02-09\2015-02-09_Xpress\2015-02-09_Express-Foam_03.mrs (24.03.2015) Barometric pressure: B = 96,2 kpa Temperature: θ = 21,9 C Relative humidity: r. h. = 10,4 % u/ R s / (mm/s) (Pa s/m) 4.87 99 6.33 100 7.79 99 9.25 99 10.71 100 12.16 98 13.61 99 Airflow resistance R s /(Pa s/m) 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 0,0 2,5 5,0 7,5 10,0 12,5 15,0 Airflow velocity u/(mm/s) Airflow resistance R s = 100 Pa s/m Laboratory: Responsible: Date: Planegg 2015/03/03 2015-03-03 Appendix A, Page 3

Description of the test procedure for the determination of the airflow resistance 1 Measurand The specific airflow resistance R S of the test object was determined. For this purpose the air pressure difference in front of as well as behind the test object was measured at different volumetric airflow rates. The specific airflow resistance R S,I for each volumetric airflow rate q i determined was calculated using the following equation: With R S, i pi A = q i R S,i specific airflow resistance in Pa s/m; p i air pressure difference across the test object with respect to the atmosphere in Pa; A q i u i cross-sectional area of the test object perpendicular to the direction of flow in m 2 ; volumetric airflow rate passing through the test object in m 3 /s; linear airflow velocity in m/s; In addition the linear airflow velocity u i was determined: u i = qi A The indicated measurement result is the specific airflow resistance R S, which is calculated for an airflow velocity of u = 0.0005 m/s by extrapolation with help of the linear regression. 2015-03-03 Appendix B, Page 1

2 Test procedure The direct airflow method (method A according to EN 29053) was applied. A steady unidirectional airflow with different air flow rates is pressed through the test object in the specimen holder. The resulting pressure drop between the two free faces of the test object is measured. The specimen holder had a diameter of D = 100 mm. 3 List of test equipment The test equipment used is listed in table B.1. Table B.1. Test equipment. Name Manufacturer Type Serial-No. Measurement system airflow resistance Software for measurement and evaluation Müller-BBM M89319-00 315003 Müller-BBM m ars v1.0.0.2 Digital measuring slide Mitutoyo CD-15PPR 07019377 Electronic balance Kern 440-49N WC0633572 2015-03-03 Appendix B, Page 2