A C18 Silica Column With Exceptional Temperature and ph Stability

Similar documents
HPLC at High Temperature and High ph with a New, Highly Stable Silica Column

Better HPLC Methods Using Temperature Programming

LC and LC/MS Column Selection Flow Chart

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Reversed Phase Solvents

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Packings for HPLC. Packings for HPLC

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

for Acclaim Mixed-Mode HILIC-1 Column

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Dilution(*) Chromatography

Hypersil BDS Columns TG 01-05

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Changing the way you think about HPLC

HPLC Column Classification

InertSustainSwift C8

Shodex TM ODP2 HP series columns

William E. Barber, Ph.D. Applications Chemist October

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Choosing Columns and Conditions for the Best Peak Shape

LUMEFANTRINUM LUMEFANTRINE

Basic Principles for Purification Using Supercritical Fluid Chromatography

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

Applications. Overview of applications of elevated temperature and temperature programmed liquid chromatography

Liquid Chromatography

Inertsil ODS-EP Technical Information

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Biochemistry. Biochemical Techniques HPLC

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

637. Thiamethoxam. HPLC method

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

High Performance Liquid Chromatography

Acclaim Mixed-Mode WCX-1

for Acclaim Mixed-Mode WCX-1

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ARTEMETHER AND LUMEFANTRINE ORAL SUSPENSION:Final text for addition to The International Pharmacopoeia (November 2008)

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Stability of Silica-Based, Monofunctional C 18 Bonded- Phase Column Packing for HPLC at High ph

LIQUID CHROMATOGRAPHY

penta-hilic UHPLC COLUMNS

for Acclaim Trinity TM P1

Impact of Instrument Dispersion on Performance of HPLC Capillary Columns

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

ANALYSIS OF BASIC COMPOUNDS

Bringing uhplc Performance to the Separation of Peptides

Silanol. Groups Liquid Chromatography

HPLC Praktikum Skript

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Reversed Phase Chromatography: Mobile phase Considerations

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Too Polar for Reversed Phase What Do You Do?

It s hot! ZIC -chilic

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Chapter content. Reference

Synthesis and Use of a New Covalently Bonded C18 Modified Carbon Clad Microporous Zirconia for Fast High Temperature Separations

An Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Volume 6, Issue 2, January February 2011; Article-015

Gemini-NX Performance paired with Axia Technology

BETASIL Columns TG Å high purity silica

LC Columns with Liquid Separation Cell Technology

ProPac WCX-10 Columns

Sepax SRT -C, Zenix -C SEC Phases

Comparison of different aqueous mobile phase HPLC techniques

HPLC Background Chem 250 F 2008 Page 1 of 24

Guide to Choosing and Using Polymer Reversed Phase Columns!

RP C18 column with feature of a silanol group

8. Methods in Developing Mobile Phase Condition for C18 Column

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

High Pressure/Performance Liquid Chromatography (HPLC)

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

State-of-the-art C18 HPLC Columns

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

ZirChrom Columns and the Metalox 200-C High Temperature Liquid Chromatography Column Heater - The Future of HPLC has Arrived.

UPLC Method Development and Validation

ACD/AutoChrom Assisted Method Development for Challenging Separations. Vera Leshchinskaya February 7, 2018

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

High Performance Liquid Chromatography (HPLC) of Three Analgesics

SECOBARBITAL Latest Revision: February 15, 1999

Flash chromatography purification of high pka organic compounds with Teledyne Isco s specialty RediSep columns

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Looking into the HPLC Column while Running CIP

Minimizing Solvent Impact on Purification of Nitrogencontaining

Comparison Guide to C18 Reversed Phase HPLC Columns

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Cation Exchange HPLC Columns

Transcription:

A C18 lica Column With Exceptional Temperature and ph Stability Brian A. Jones 1, Stephanie J. Marin 1, Jody Clark 1, Nathan L. Porter 1, J. Andreas Lippert 2, and Todd M. Johnson 2 1. Selerity Technologies, Inc. 2484 W. Custer Road Salt Lake City, UT 84104 www.selerity.com 2. Dept. of Chemistry Weber State University gden, UT 84408 www.weber.edu 1

Abstract New instrumentation has made it possible to separate materials via liquid chromatography at temperatures up to 200 C, but most traditional silicabased stationary phases can only be used to about 60 C. In this paper, we report the development of a polycarbosilane bonding chemistry that is hydrolytically stable against breakdown in aqueous environments up to 200 C. An underlying barrier layer composed of polyfunctional silanes provides the base for the octadecylsilane functional layer, without compromising the traditional selectivity seen with silica-based columns. This new stationary phase was subjected to different mobile phase compositions at temperatures up to 200 C, and evaluated for signs of stationary phase degradation or collapse. The underlying silica support is also protected by the bonded phase against dissolution and remains intact at ph extremes as well. 2

Benefits of Stable Columns Wide ph range Ion suppression for acids Ion suppression for amines Column regeneration by elution of contaminants at ph extremes For example: Separating basic analytes at high ph gives: Increased loading Increased retention Increased resolution 3

Benefits of Stable Columns High thermal stability Selectivity tuning Faster analysis Less organic modifier required Wider temperature programming range Extended column lifetimes under more moderate conditions 4

Blaze 200 Bonding Chemistry Generation 1 ethyl-bridged carbosilane dendrimers with multiple attachment points as barrier layers and functional layers Representative reagents: (CH 2 CH 2 Cl 3 ) 4 C 18 (CH 2 CH 2 Cl 3 ) 3 US Patent 6,794,044, and additional US and International Patents Pending 5

Selerity Blaze 200 Multiple Point Bonding H H H H H H H H H H H H H H lica Surface & Barrier Layer US and International Patents Pending 6

C 11 H 23 Functional Layer Added C 7 H 15 H H H H H H H H H H H H US and International Patents Pending 7

Comparison Between Durable Chemistries Waters organic/inorganic hybrid family Stable chemistry, apparently usable at high ph and elevated temperatures Each particle type must be optimized Particle strength partially compromised, Anal. Chem. 75 (2003) 6781-6788. Surface organic groups reduce low ph stability US Patent 6,528,167, assigned to Waters Corporation Agilent StableBond Sterically hindered phases give good stability only with low ph at elevated temperatures Selerity Blaze 200 mple surface coating with readily purifiable dendrimeric reagents Works on any silica and has traditional silica selectivity Underlying particle structure undisturbed, resulting in the highest strength and efficiency ne column has stability at low and high ph and high temperature 8

Selerity Polaratherm Series 9000 Total Temperature Controller Used in this study except where noted Forced air oven and chiller Isothermal and thermal gradient operation Sub-zero to 200 C Thermal gradients up to 30 C/min Mobile phase preheating and pre-cooling Peltier effluent temperature control Vapor sensor Compatible with any HPLC system Integrated software control with Waters, Agilent, and EZChrom 9

Analgesics Blaze 200 C18 UV1 7 comp analgesics Blaze 200 150 x 4.6 mm 30:70 Acetonitrile:water w/ 0.1% TFA 1.5 ml/min UV 220 nm 50 C to 140 C at 30 /min, hold for 10 minutes Elution order: Acetaminophen Caffeine Salicylamide Aspirin Salicylic acid Naproxen Ibuprofen 0 1 2 3 4 5 6 7 8 Minutes 10

Selectivity Determination Blaze 200 AU 0.030 0.025 0.020 0.015 0.010 0.005 0.000 Uracil Toluene Ethylbenzene Quinizarin Amitryptyline Column: Blaze 200 C18, 3 μm, 100A, 100 X 4.6 mm Detection: UV 254 nm Flow Rate: 2.0 ml/min Mobile Phase: 80:20 methanol:5mm potassium phosphate ph 7.0 Temperature: 25 C 0 1 2 3 4 5 6 7 8 9 10 Minutes SRM 870 test conditions were followed, and indicate typical C18 silica column selectivity. Tailing and asymmetry for amitryptyline indicate some silanol interaction. Peak shape and elution of quinizarin indicate low activity toward metal chelating agents. 11

Selectivity Comparison Blaze 200 C18 / Zorbax SB-C18 AU 0.0175 0.0150 0.0125 0.0100 0.0075 0.0050 Analytes: Uracil, Phenobarbital, Butalbarbital, Carbromal Mobile Phase: 20:80 ACN:3mM phosphate at ph 7.0, 3 ml/min. Temperature: 60 C Columns: 4.6 x 150 mm Zorbax SB-C18 Blaze 200 C18 0.0025 0.0000 0 1 2 3 4 5 6 7 8 9 10 Minutes 12

Column degradation studies were performed with an LC Module I (Waters Corporation, Milford, Massachusetts, USA) equipped with an integrated auto sampler and an internal UV/Vis variable wavelength detector. The HPLC instrument was coupled to a Series 8000 column oven (Selerity). All separations were carried out with prototype Blaze 200 C18 columns (2.1 x 100mm) packed with 3 μm particles. The stability of the columns was evaluated by increasing the temperature using various mobile phase and ph conditions. All columns were tested by flushing with 1000 column volumes of 40:60 organic to water mobile phase at 50 C prior to being exposed to the experimental conditions. This allowed the determination of loss of chromatographic performance during the column evaluation. A test mixture containing uracil, phenol, benzene, and acetophenone in 35:65 ACN:water was used. The baseline data for mobile phases containing less than 50% organic solvent was taken at 100 C. Separation of the test mixture could not be achieved at organic mobile phase concentrations greater than 50% at 100 C. Therefore, all mobile phase treatment conditions involving compositions with organic modifier greater than 50% were either evaluated at a base line of or switched to a 40% organic isocratic solution during the column evaluation. 13

The column temperature was increased in 20 degree increments. After flushing with 1000 column volumes at elevated temperature, the temperature effects on the column were evaluated by switching the column temperature back to the baseline conditions and injecting the test sample. For the ph treatment studies, the columns were subjected to either 60% or 20% ACN isocratic compositions at each ph. The buffers used were: ammonium acetate for ph 9 and 10, piperidine for ph 12, and monobasic sodium phosphate for ph 2 and 3. All buffers were prepared in HPLC grade water and then filtered through a 0.22 μm (name of) filter membrane (company and location). After the overnight 1000 column volume treatment at each ph and temperature, the pumps were primed and the column was flushed for at least 15 min with ACN and water at a 40:60 ratio to remove all buffer from the system. Each column temperature treatment was evaluated by running the diluted test mix at the baseline temperature of 50 C with the 40:60 ACN:water mobile phase. The system was then switched back to the buffer:acn mobile phase for the next temperature increment. 14

Effects of Temperature and ph on the Efficiency of Acetophenone for 60% ACN 120% Percentage of Initial Theoretical Plates 100% 80% 60% 40% 20% ph 2.0 ph 3.0 ph 9.0 ph 10.0 water 0% 40 60 80 100 120 140 160 180 200 vernight Column Temperature in o C 15

Temperature Effects on the Theoretical Plates of Benzene for Various Mobile Phases (Blaze 200 ) 120% Percentage of Initial Theoretical Plates 100% 80% 60% 40% 20% 20% MeH 40% MeH 60% MeH 80% MeH 0% 100 110 120 130 140 150 160 170 180 190 200 vernight Column Temperature in o C 16

Availability of Columns High temperature, Blaze 200 - Selerity, RIC ph extreme, phidelity Though Restek Corporation under license from Selerity Future work: Pore sizes, particle sizes, expanded chemistries 17

18

Conclusions Highly durable coating and protective layer lica columns with traditional selectivity usable in new realms of ph and temperature 19

Acknowledgements Weber State University students Jarem B. Lloyd Jared P. Smith Bryce T. Johnson Jason Furlow Restek Corporation 20