CTC 155 / 350 / 660 Dry-block calibrator

Similar documents
473-SHX Dew Point Mirror

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

473 Dew Point Hygrometer

Pressure. 1 Fitting PA R - N R2

Fitting PS P - B - R2

E8EB-N0C2B E8EB-N0B2B

Maximum Performance From Dry-Well Thermometer Calibrators. Mark Finch Product Manager EMEA Fluke Calibration

ED 701 General Industry Pressure Transmitter

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Dewpoint Meter Data Sheet / Instructions

Automatic titrators, TitroMatic

DYNAMIC LOAD COMPENSATION

Data Sheet / Instructions. Dewpoint MeterO

SPECIFICATION. Messrs. DATE 20 June, 2013 No. V AP4, AG4 Pressure Sensor

Calibration of Temperature Block Calibrators

473 Dew Point Hygrometer

Features : Protection type : Hiccup mode, recovers automatically after fault condition is removed

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

EA-10/13. EA Guidelines on the Calibration of Temperature Block Calibrators. Publication Reference PURPOSE

p s s e r i e s

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

Operating Instructions for Digital Manometer. Model: MAN-SD

Metallized Polypropylene film capacitor PCMP 371

ea980r Digital Anemometer User Manual

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Type Plunger Height x pitch Operating force (OF) Without ground terminal Flat type 4.3 x 6.5 mm General 0.98 N (100 gf) B3F-6000 B3F-6100

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

PHOS 15 LED PROJECTOR

Ceramic PTC Thermistor: PT Series

K04 TYPE -40 C +85 C 20000H

INSTRUCTION MANUAL FOR MM10 Relay

Reference Only Spec. No. JEFL243B 0003F-01 P 1/ 6

HD32.2 WBGT Index HD 32.2 INSTRUMENT FOR THE ANALYSIS OF THE WBGT INDEX

AC axial compact fan

Peltier Application Note

AC axial compact fan

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

American Zettler AZ742 RELAY Datasheet

Relative pressure transmitter type 520

Introduction to Blackbody Sources

Pressure Display Controller

PHOENIX CONTACT - 04/2016. Features

INE-DDB-303A Portable Conductivity Meter Instruction Manual

Power Resistor Thick Film Technology

3mm Photodiode PD204-6B

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

HiPace 1200, with TC 1200, DN 200 CF-F

DIN Timers TD. Options and ordering codes. Specification

Pressure transmitters for industrial applications MBS 32 and MBS 33

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

792A AC/DC Transfer Standard

W 30 Photoelectric proximity switches: Clear signals even with low remission

PTS Volt DC surface mount resettable PTC devices. Technical Data Applications. Agency information.

792A AC/DC Transfer Standard

T h e rm i s t o r s

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

KF Series. -40 to to 100 VDC 0.47 to F

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

4 Way Reversing Valve

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

HD32.2 WBGT Index HD32.3 WBGT-PMV. [ GB ] - WBGT index. - PMV index and PPD

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

M2 SERIES THERMOSTATS 0 F to 240 F, Narrow Differential, Hermetically Sealed ½

Specification for ViTron Photo Diode. Ø5 OVAL [Photo Diode] Part No. : VPD5V-BN60T. VISSEM Electronics Co., Ltd. Revision No. : Ver. 1.

Impedance relay and protection assemblies

AC axial compact fan

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700

Air velocity & IAQ measuring instruments

THERMYS 150. Advanced field reference thermometer / temperature calibrator

Air velocity & IAQ measuring instruments

Tunable White LED compact

FL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact

Low-Voltage Analog Temperature Sensors in SC70 and SOT23 Packages

5mm Phototransistor PT333-3B

Software BioScout-Calibrator June 2013

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

5mm Silicon PIN Photodiode, T-1 3/4 PD333-3B/H0/L2

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Technical Data Sheet 3mm Silicon PIN Photodiode T-1

Intuitive air velocity and IAQ.

Metal Oxide Varistor:TVM-B Series

PRODUCT SPECIFICATIONS

Non-Contact Safety Systems CMS

Transcription:

CTC 155 / 350 / 660 Dry-block calibrator Wide temperature range: CTC-155: -25 to 155 C CTC-350: 28 to 350 C CTC-660: 28 to 660 C Fast calibration External reference sensor External sensor control Easy to carry 17.01.2017 Pressure (DAkkS) Temperature Flow Humidity Electric Quantities Masses and Scales 1 / 9

Multi-Information Display Calibration Settings Shows the actual calibration settings for reference sensor and Stability criteria. Can be accessed and changed directly in the display by use of the arrow keys. Status Bar Shows information about recalibration due status and hot/ cold safety warnings and keeps track on date and time. Calibration Status Shows current status of the calibrator, like heating/cooling, stability achieved and expected time to stability. Functions Bar Shows the current possibilities of the function keys. Informative color display and intuitive operation The CTC series is designed with an easy to read and very informative color display that gives you a full overview of the calibration task youcurrently are preforming. Function Keys The function keys serve as shortcuts to the main functions like Set, Reset, Auto step and Switch test. When entering one of the functions the function key shows the options within the selected function. Useful Features Set function Preset mode Auto Switch Test Auto Stepping Special features Mutli sensor calibration IRI Intelligent Recalibration Information Plug and Play reference sensors Broad range of inserts Reference sensor protection This document is subject to change without notice 2 / 9

Specifications CTC-155 Temperature range: Temp. @ ambient 23 C / 73 F -25 to 155 C / -13 to 311 F Temp. @ ambient 0 C / 32 F -39 to 155 C / -38 to 311 F Temp. @ ambient 50 C / 104 F -7 to 155 C / -19 to 311 F Accuracy: CTC-155 with internal ref. sensor ±0.3 C / ±0.54 F CTC-155 with STS-102 ±0.2 C / ±0.36 F CTC-350 with STS-120 ±0.2 C / ±0.36 F Specification when using the internal reference. (Load 4 mm OD reference probe in the center of the insert). Stability: ±0.04 C / ±0.07 F Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes. Radial Homogeneity (difference between holes) 0.04 C / ±0.072F Settings Resolution 1 or 0.1 od 0.001 Units C or F or K Heating time: 23 to 155 C / 73 to 311 C 13 minutes Cooling time: 155 to 23 C / 311 to 73 F 12 minutes Cooling time: 23 to -25 C / 73 to -13 F 16 minutes Time to stability (typical) 10 minutes Mains Power: Voltage: 115 V (90-127) / 230 V (180-254) Max. Power Consumption 1150 VA Frequency: 50 Hz ±5, 60 Hz ±5 Instrument dimensions (L x W x H): Instrument weight: Immersion depth: Well diameter: Insert Dimension (diameter x length): Electrical: Switch Input (dry contact) Test voltage: Test Current: Digital Interface USB 2.0 248 x 148 x 305 mm 5.5 kg 120 mm 26 mm 25.8 x 100 mm max. 14VDC max. 1 ma Enviromental: Operating temperature: 0 to 50 C Storage Temperature: -20 to 50 C Humidity: 5 to 90% Rh, non-condensing Protection Class: IP-10 This document is subject to change without notice 3 / 9

External reference sensor (Pt100) STS-120-A-915-25 to 155 C / -13 to 311 F Accuracy Hysteresis (@ 0 C/32 F) Long Term Stability (@ 0 C/32 F) Repeatibility Responsetime STS-120-A t 09 (90%) Dimensions Diameter Length Max. height over calibrator top 0.01 C / 0.018 F 0.014 C / 0.025 F 0.004 C / 0.007 F 18 sec. 4 mm 140 mm 20 mm External reference sensor (Pt100) STS-102-A -50 to 155 C / -58 to 311 F Accuracy Hysteresis (@ 0 C/32 F) Long Term Stability (@ 0 C/32 F) Repeatibility Responsetime STS-120-A t 09 (90%) Dimensions Diameter Length Cable length 0.01 C / 0.018 F 0.014 C / 0.025 F 0.002 C / 0.0036 F 16 sec. 4 mm 30 mm 1 mm MVI Improved temperature stability Unstable mains power supplies are a major contributor to on-site calibration inaccuracies. Traditional temperature calibrators often become unstable in production environments where large electrical motors, heating elements, and other devices are periodically cycled on or off. The cycling of supply power can cause the temperature regulator to perform inconsistently leading to both inaccurate readings and unstable temperatures. This document is subject to change without notice 4 / 9

Specifications CTC-350 Temperature range: 28 to 350 C / 82 to 662 F Lowest Calibration temperature ambient +5 C / 41 F Accuracy: CTC-350 with internal ref. sensor CTC-350 with STS-120 ±0.45 C / ±0.81 F ±0.25 C / ±0.45 F Stability: ±0.05 C / ±0.09 F Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes. Radial Homogeneity (difference between holes) 0.04 C / ±0.072F Settings Resolution 1 or 0.1 od 0.001 Units C or F or K Heating time: 23 to 350 C / 73 to 662 C 6 minutes All specifications are given with an ambient temperature 23 C/73.4 F ±3 C/5.9 F. Specified at 115V/230V. Cooling time: 350 to 100 C / 662 to 212 F 18 minutes Cooling time: 100 to 50 C / 212 to 122 F 13 minutes Time to stability (typical) 10 minutes Mains Power: Voltage: 115 V (90-127) / 230 V (180-254) Max. Power Consumption 1150 VA Frequency: 50 Hz ±5, 60 Hz ±5 Instrument dimensions (L x W x H): Instrument weight: Immersion depth: Well diameter: Insert Dimension (diameter x length): Electrical: Switch Input (dry contact) Test voltage: Test Current: Digital Interface USB 2.0 248 x 148 x 305 mm 5 kg 115 mm 26 mm 25.7 x 120 mm max. 14VDC max. 1 ma Enviromental: Operating temperature: 0 to 50 C Storage Temperature: -20 to 50 C Humidity: 5 to 90% Rh, non-condensing Protection Class: IP-10 This document is subject to change without notice 5 / 9

External reference sensor (Pt100) STS-120-A-913 0 to 350 C / 32 to 662 F Accuracy Hysteresis (@ 0 C/32 F) Long Term Stability (@ 0 C/32 F) Repeatibility Responsetime STS-120-A t 09 (90%) Dimensions Diameter Length Max. height over calibrator top 0.01 C / 0.018 F 0.014 C / 0.025 F 0.004 C / 0.007 F 18 sec. 4 mm 135 mm 10 mm MVI Improved temperature stability Unstable mains power supplies are a major contributor to on-site calibration inaccuracies. Traditional temperature calibrators often become unstable in production environments where large electrical motors, heating elements, and other devices are periodically cycled on or off. The cycling of supply power can cause the temperature regulator to perform inconsistently leading to both inaccurate readings and unstable temperatures. This document is subject to change without notice 6 / 9

Specifications CTC-660 Temperature range: 28 to 660 C / 82 to 1220 F Lowest Calibration temperature ambient +5 C / 41 F Accuracy: CTC-660 with internal ref. sensor CTC-660 with STS-120 ±0.85 C / ±1.531 F ±0.45 C / ±0.8 F Stability: ±0.08 C / ±0.14 F Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes. Radial Homogeneity (difference between holes) 0.1 C / ±0.18F Settings Resolution 1 or 0.1 od 0.001 Units C or F or K Heating time: 23 to 660 C / 73 to 1220 C 18 minutes All specifications are given with an ambient temperature 23 C/73.4 F ±3 C/5.9 F. Specified at 115V/230V. Cooling time: 660 to 100 C / 1220 to 212 F 39 minutes Cooling time: 100 to 50 C / 212 to 122 F 18 minutes Time to stability (typical) 5 minutes Mains Power: Voltage: 115 V (90-127) / 230 V (180-254) Max. Power Consumption 1150 VA Frequency: 50 Hz ±5, 60 Hz ±5 Instrument dimensions (L x W x H): Instrument weight: Immersion depth: Well diameter: Insert Dimension (diameter x length): Electrical: Switch Input (dry contact) Test voltage: Test Current: Digital Interface USB 2.0 248 x 148 x 305 mm 6.1 kg 115 mm 26 mm 25.7 x 120 mm max. 14VDC max. 1 ma Enviromental: Operating temperature: 0 to 50 C Storage Temperature: -20 to 50 C Humidity: 5 to 90% Rh, non-condensing Protection Class: IP-10 This document is subject to change without notice 7 / 9

External reference sensor (Pt100) STS-120-A-966 0 to 660 C / 32 to 1220 F Accuracy Hysteresis (@ 0 C/32 F) Long Term Stability (@ 0 C/32 F) Repeatibility Responsetime STS-120-A t 09 (90%) Dimensions Diameter Length Max. height over calibrator top 0.01 C / 0.018 F 0.014 C / 0.025 F 0.004 C / 0.007 F 26 sec. 4 mm 151 mm 25 mm MVI Improved temperature stability Unstable mains power supplies are a major contributor to on-site calibration inaccuracies. Traditional temperature calibrators often become unstable in production environments where large electrical motors, heating elements, and other devices are periodically cycled on or off. The cycling of supply power can cause the temperature regulator to perform inconsistently leading to both inaccurate readings and unstable temperatures. This document is subject to change without notice 8 / 9

Inserts Inserts for CTX-155 and CTC-350 are made of aluminium. Inserts for CTC-660 are made of brass. All specifications on hole sizes refer to the outer diameter ot the sensor-under-test. The correct clearance size is applied in all predrilled inserts. All CTC-155 inserts include an insulation plug. Predirlled Insert metric Probe Diameter CTC-155 CTC-350 CTC-660 3 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm 10 mm 11 mm 12 mm 13 mm 14 mm N/A 15 mm N/A 16 mm N/A *) *) 18 mm N/A *) *) 20 mm N/A *) *) Multi-hole *) No reference hole in insert. Undirlled Inserts Inserts CTC-155 CTC-350 CTC-660 5-pack with ref. hole Typical weight 75 g 170 g 510 g Use of other inserts may reduce performance ot the calibrator. To get the best results out of the calibrator, the insert dimensions, tolerance and material is critical. We highly advice using our inserts, as the guarantee trouble free operating. Do you need a customized inserts? Please contact us for more information. This document is subject to change without notice 9 / 9