Sample Preparation for Ion Chromatography

Similar documents
New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Overcoming Challenging Matrices in Ion Chromatography

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

columns IonPac AS17-C Anion Exchange Column

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

columns IonPac AS22 Anion-Exchange Column

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Thermo Scientific. Anion-Exchange Column

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Dionex IonPac AS28-Fast-4µm column

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Concentrator and Trap Columns. Column: IonPac AG15, AS15, 2 mm. Eluent Source: EG40 Concentrator. Temperature: 30 C Column: IonPac AC15 (2 50 mm)

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

anion-exchange column

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Determination of trace anions in concentrated hydrofluoric acid

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

columns IonPac AS18 Anion-Exchange Columns

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Inline sample preparation for the determination of anions in sodium hydroxide

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Determination of Adsorbable Organic Halogen in Wastewater

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Determination of urea in ultrapure water by IC-MS/MS

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

columns IonPac SCS 1 Silica Cation Separator

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

Determination of Sulfate and Chloride in Ethanol by Ion Chromatography

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Utility of the Charge Detector in Ion Chromatography Applications

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Determination of silicate in high-purity water using ion chromatography and online sample preparation

Determination of Methylamine in Drug Products

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Advances in Sample Preparation for Accelerated Solvent Extraction

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

IonPac Trace Cation Concentrator

Thermo Scientific Dionex IonPac CS17 Cation-Exchange Column

High-Performance Chromatography Superior isocratic separation of

columns I o n P a c AS11 and AS11-H C Anion-E x c h a n g e C o l u m n s

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Determination of trace anions in basic solutions by single pass AutoNeutralization and ion chromatography

The Determination of Trace Anions in Concentrated Phosphoric Acid

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

ION CHROMATOGRAPHY SYSTEM S 150

The determination of trace anions in concentrated phosphoric acid

suppressors Eluent Suppressors for Ion Chromatography

Determination of Trace Cations in Concentrated Acids Using AutoNeutralization Pretreatment and Ion Chromatography

The power to increase productivity. Thermo Scientific Dionex Reagent-Free Ion Chromatography (RFIC) System Capabilities

Determination of Trace Anions in Organic Solvents

Determination of Cr(VI) in Water, Waste Water, and Solid Waste Extracts

Expanded capabilities in ammonium and amine detection

Theory of Ion Chromatography

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Novel Electrodeionization Devices: Applications in Inorganic Analysis

Ion chromatography. Ion chromatography

HPLC Sample Preparation

User Manual. IonPac NS2 Columns Revision 02 October For Research Use Only. Not for use in diagnostic procedures.

Thermo Scientific Dionex eluent suppressors for ion chromatography

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

IonPac SCS 1 IonPac SCG 1

groups I and II cations, amines, divalent transition metals

Thermo Scientific Dionex IonPac AS11 and AS11-HC Anion-Exchange Column

ProPac WCX-10 Columns

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

Air Monitoring. Semi-continuous determination of ambient air quality

Waters. Ion Chromatography

Determination of trace anions in high-nitrate matrices by ion chromatography

[ Care and Use Manual ]

Determination of trace anions in concentrated glycolic acid

IC5000 Ion Chromatography System

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Determination of Inorganic Cations and Ammonium in Environmental Waters by Ion Chromatography Using the IonPac CS16 Column

Development of the Thermo Scientific Dionex IonPac AS26 Column for Haloacetic Acid Analysis

Determination of Trace Anions in Concentrated Glycolic Acid

Determination of chlorine, bromine, and sulfur in polyethylene materials using combustion IC with a carbonate/bicarbonate eluent

Suppression in anion chromatography. More sensitive analysis of anions and organic acids

Transcription:

Sample Preparation for Ion Chromatography Comprehensive Solutions to Sample Preparation Challenges Now sold under the Thermo Scientific brand

Choose from a Broad Range of Solutions No matter what your needs are, turn to Dionex the ion chromatography (IC) technology leader for a comprehensive range of proven sample preparation solutions. Easy to understand and implement Simple to operate Highly reliable and reproducible Saves time and lowers operating costs The simplicity and ruggedness of IC often requires no need to prepare a sample before injection. In many cases, a simple dilution of the sample with deionized water is all that s needed. Sometimes more is required to protect the column by removing contaminants or particles or to enhance the sample to make it detectable. Any sample preparation technique must maintain sample integrity, be reproducible, and require minimal labor to accomplish. Dionex solutions span: Off-line solutions that are easy and practical to implement In-line and automated technologies using proprietary technologies Specialized and high-throughput solutions W L S P L C Autosampler Solutions In-line RFIC-ESP Chromeleon Software Cartridge Technologies Off-line Electrolytic Trap Devices IC Integration 2

Dionex Sample Preparation Solutions AutoDilution Conditional determination of high analyte concentration with automatic dilution and reinjection Autosampler with Chromeleon Chromatography Data System (CDS) Software Matrix Elimination Remove interfering matrix ions and organic contaminants Off-line OnGuard II Cartridges In-line InGuard Cartridges In-line IonPac NG-1 Columns Concentrator Columns Capture and concentrate ions from large, dilute sample volumes 15 Anion IC and RFIC Concentrator Columns 3 Cation IC and RFIC Columns 3 Transition Metal IC and RFIC Trap Columns Trap Columns Purify eluent or polish samples Anion IC and RFIC Trap Columns Cation IC and RFIC Concentrator Columns RFIC-ESP Reagent-Free Ion Chromatography (RFIC )-Electrolytic Sample Preparation (ESP) Continuously Regenerated Trap Columns (CR-TC) AutoNeutralization Cartridges Electrolytic Water Purifiers (EWPs) for Trace Analysis AutoPrep with ESP for Trace Analysis of Anions or Cations Sample Filtration Remove particulates that can damage your system; remove microbes to prevent analyte degradation Off-line Syringe Filters In-line AS-DV Autosampler Filters In-line Filter Frit Cartridges Specialty Systems Combustion IC and Air Sampling systems Combustion IC for Halogen and Sulfur Analysis Air Sampling System for Ionic Analysis Chromeleon Chromatography Data System Software Plays an integral role in most Dionex automated solutions Monitor system pressure to detect filter clogs Optimum injection parameters for injection loops and concentrator columns Visualization tools for matrix elimination and analyte concentration Conditionally controlled autodilution and electrolytic sample preparation techniques 3

AutoDilution and Analysis Automatic Detection, Dilution, and Re-injection of Highly Concentrated Samples Challenge Sample too concentrated for analysis Sample needs dilution Delay in analysis time Extra work Solution Dionex AutoDilution Capabilities Automated detection of concentrated samples Automatic dilution, reinjection, and analysis Faster results Saves effort, time, and money IC systems equipped with an autosampler, Chromeleon CDS software, and the AutoDilution license can monitor chromatographic results. If peak results fall outside a user-specified range, the system will automatically dilute the sample and reinject it. Decisions to dilute and reinject can be based on a single parameter such as peak area, height, amount, resolution or other chromatographic value, or on a combination of values. AutoDilution: Large Loop/Small Loop Conditional Injection Waste sump reinjected, small loop. IonPac AS18 4 mm, 33 mm KOH 4 Sulfate Chloride 4 Sulfate Calibration Curve Sample result µs Nitrate Area (µs*min) Highest standard Minutes 12 2886 Sample is too concentrated, and analytes are out of the calibration range. Concentration (ppm) 2 28862 Waste sump reinjected, small loop. IonPac AS18 4 mm, 33 mm KOH 4 Sulfate 1.4 Sulfate Calibration Curve Highest standard µs Chloride Area (µs*min) Sample result Nitrate Minutes 12 28861 Concentration (ppm) 7 28863 Data system detects concentrated sample, and then autosampler dilutes and reinjects it. Analytes are now in the calibration range. 4

Matrix Elimination Selectively Remove Interfering Ions from Matrices Using Solid-Phase Extractants Challenge Interfering ions Poor IC performance Short consumables lifetime High cost of ownership Solution Dionex Matrix Elimination Cartridges Eliminate interfering ions Automated and manual methods Superior IC performance Extended lifetime of consumables Lower cost of ownership Off-line Matrix Ion Elimination OnGuard II Cartridges OnGuard II Cartridges have Luer inlets for manual processing of a limited number of samples. A wide range of cartridges loaded with resins in 1 and 2.5 cc capacity formats remove matrix interferences encountered in many ion chromatography applications, (see table at right). These cartridges have wide ph stability and allow low-level ion analysis. They remove both column-fouling substances and interfering ions where several ml of sample is available. An OnGuard Sample Prep Station is available for simultaneous matrix elimination of multiple samples. Resin A Ag Ba OnGuard II Cartridges* Removes from Sample Matrices Anionic contaminants; Neutralization of highly acidic samples Chloride, bromide, and iodide High concentrations of sulfate High levels of alkaline earth and transition metals; Neutralizes highly alkaline H samples (e.g., sodium hydroxide or sodium carbonate) Na High levels of alkaline earth and transition metals without acidifying the sample M Transition metals; also for matrix elimination of alkali and alkaline earth metals Phenolic fraction of humic acids, tannic acids, lignins, anthocyanins, and P azodyes prior to analysis by ion exchange Hydrophobic substances such as aromatic dyes, some aromatic carboxylic acids, RP hydrocarbons, and surfactants Ag/H Chloride, bromide, and iodide from concentrated matrices such as brines Respective contaminants using a layered resin cartridge containing the Ba, Ag, Ba/Ag/H and H styrene-based sulfonic acid resins *Cartridges can be used singly or in series. Peak Area 6,, 5,5, 4,5, 2 4 6 8 1 12 14 Injection # Iodide Area = 1 mg/l RSD (peak area) = 1.4% RSD (retention time) =.4% 15651 OnGuard II RP for the removal of fat from milk. Failure to remove fat prior to IC analysis leads to high column backpressures, loss in column capacity, and decreased retention times. 5

Matrix Elimination Continued In-line Matrix Ion Elimination InGuard Cartridges InGuard Cartridges provide high-throughput automated removal of matrix interferences encountered in many IC applications. Depending on the cartridge s location in the IC system, the autosampler (low pressure) or pump (high pressure) pushes the sample through the InGuard Cartridge. The number of samples that can be treated with an InGuard Cartridge depends on the matrix composition, concentration of compounds to be removed, and the sample injection volume. Chemistries operate optimally at flow rates between.5 and 2 ml/min. They are suitable for both standard-bore and microbore IC systems. 7 1.6%NaCl InGuard treated sample µs 3 Minutes 28716 InGuard Cartridges for High-Throughput Automated Matrix Elimination* Resin Removes from Sample Matrices Ag Halides H Cations and ph adjustment Na Cations HRP Hydrophobic species, azo- and cyano-containing species Na/HRP Metals (Na) plus organics (HRP) *InGuard Kits are available that contain everything you need for high-throughput matrix elimination of organics, halides, sample ph reduction, and more. Treatment of a brine sample with InGuard Ag Cartridge removes interfering chloride ions to permit analysis of small amounts of other anions. IonPac NG-1 Columns These columns are packed with highly hydrophobic cross-linked polystyrene resin beads for the removal of organic contaminants from samples, such as humic acids. The option of a two-column setup with a 1-port valve enables automatic resin cleaning of one trap column while the other is being used for sample preparation. NG-1 kits are available for organic removal for anion and cation analysis. 6

Concentrator Columns Capture and Concentrate Sample Ions from Large Sample Volumes Challenge Sample ions too dilute Manual methods prone to errors and not reproducible Time consuming Solution Dionex Sample Pre-Concentration Preconcentrate ions, increase sensitivity Fully automated, highly reproducible Reduced errors and contamination Saves time and money IonPac Concentrator Columns can be used to preconcentrate ions as required for high-purity water analysis in, for example, the power and semiconductor industries. The columns retain ions from a measured volume of aqueous sample matrix, thereby concentrating the analyte species and lowering detection limits. Concentrator Columns enable the analysis of ions at μg/l (ppb) to ng/l (ppt) levels. Waste L P W C S L Autosampler Pump Concentrator Column Guard Column Analytical Column Suppressor Detector The concentrator column is typically placed on the injection valve in place of the sample loop, just before the analytical column. Sample is first collected on the concentrator column, which strips and retains the ions as the sample flows to waste. With a switch of the valve, eluent then flows through the column eluting the analytes to the analytical column. Anion IC and RFIC Concentrator Columns Dionex offers 15 Anion Concentrator Columns with differing sizes and capacities for applications using hydroxide, carbonate/ bicarbonate, or borate eluents. Cation IC and RFIC Concentrator Columns Cation Concentrator Columns are fully functionalized with carboxylic acid for methane sulfonic acid (MSA) and sulfuric acid eluents. One column has a sulfonic acid functional group for HCl/DAP HCl eluents. Transition Metal IC and RFIC Concentrator Columns The Trace Metal Concentrator Column is a high-capacity, cation concentrator column used for coupling the MetPac CC-1 column to the IonPac CS5 or CS5A analytical columns when performing chelation IC. 1 µs 2 ml Pre-Concentrated on UTAC-LP1 25 µl Direct Injection 1 5 1 2 4 3 6 7 5 1 14 Minutes 8 9 1 11 µs 1 2 3 4 5 6 7 8 9 1 11 5 1 14 Minutes Peaks: 1. Fluoride.5 mg/l (ppm) 2. Acetate.25 3. Formate.1 4. Chlorite.5 5. Chloride.3 6. Nitrite.5 7. Carbonate.2 8. Bromide.1 9. Sulfate.1 1. Nitrate.1 11. Chlorate.1 21572 Comparison of direct injection and preconcentration using the UTAC-LP1 for the determination of trace anions. 7

Trap Columns Purify Eluent or Polish Samples Challenge Unwanted analytes interfering with separation Contaminant buildup on guard and/or analytical column Poor results Solution Dionex Trap Columns Remove eluent and sample contamination and improve results Easy to use Prolong lifetime of consumables Lower cost of ownership IonPac Trap Columns prevent unwanted analytes from interfering with the separation of your analytes of interest. They contain high-capacity, low-efficiency, ionexchange resins that strip and retain trace contaminants from the eluent and prevent their concentration on the guard and analytical columns. H 2 O + H 2 Eluent H 2 O + O 2 + HA Cathode (-) OH - OH - OH - Anion Exchange Membrane C + C + C A - + A - C + OH - A - Anion Exchange Membrane H + A - H + A - H + Anode (+) H 2 O Regenerant Cations/Hydroxide to Concentrator Column H 2 O Regenerant CR-CTC II neutralizes acidic samples, removes anion contaminants. Trap Columns and RFIC Devices These columns contain high-capacity resins designed to efficiently trap contaminants in eluents or samples. Back pressure is strictly controlled to provide the most useful devices available. Included are ATC-3 and ATC-HC anion trap devices, as well as the borate form ATC column. The CTC Cation Trap column provides high efficiency trapping of cations from samples, and in the hydrogen form it acts to neutralize basic samples. Continuously Regenerated Trap Columns (CR-TC) CR-TC technology provides continuously regenerated sample purification devices for maintenance-free operation. Both anion removal (CR-ATC) and cation removal (CR-CTC II) devices are available. CR-CTC II removes lithium and neutralizes hydroxide of borated water samples from nuclear power plants. MFC-1 Metal-Free Trap Columns The IonPac MFC-1 Metal-Free Column contains a special chelating resin. This column is placed in the eluent line prior to the injection valve to remove transition metals from high-ph eluents. Cation Polisher Columns for Anion Analysis These columns remove metallic contaminants and other cations such as calcium and magnesium from the sample stream while performing anion analysis, and include the: Cation Polisher Na + Column for anion analysis, which is a cation-exchange column in the sodium form and packed in a lowpressure format for autosampler operation. Cation Polisher H + Column for anion analysis, which is a higher-capacity version in the hydronium form. 8

RFIC-ESP Dionex Reagent-Free Ion Chromatography Electrolytic Sample Preparation Challenge Ionic contamination in eluent stream Matrix contamination Cross-contamination for trace analysis Method difficult to transfer between systems Solution RFIC-ESP Options Automated ion removal from eluent stream Easy to understand Simple transfer to another system Highly reproducible and precise Reduced handling and human error Electrolytic Devices for Automated Sample Pretreatment Several Dionex IC systems integrate hardware and software to enable automated electrolytic removal of ions from an eluent stream using protocols that are easily understandable, simple to transfer to another system, and highly reproducible and precise. Highly reproducible results, instrument-toinstrument and lab-to-lab Reduced human error and inconsistencies Reduced manual operation with reduction in labor costs and sample processing time Reduced system complexity by eliminating sample loading pump Ultralow backgrounds from on-line electrolytic water purification with routine trace (ng/l) analysis Automated purification, concentration, and calibrations providing reduced labor costs and improved quality of results AutoNeutralization Cartridges The determination of anions in concentrated bases and the determination of cations in concentrated acids are important applications in industrial, health and safety, and environmental fields. Direct injection of concentrated acids or bases will overload the column resulting in poor chromatography and making ion quantification difficult or impossible. AutoNeutralization is a highcapacity electrolytic ion-exchange device that neutralizes basic or acidic samples prior to injection. A sample can be trapped in the AutoNeutralization device for as long as necessary to fully neutralize the sample matrix. The sample is then transferred to a concentrator column, and then to the analytical separation column. Electrolytic Water Purifiers (EWPs) EWP units are devices packed with various ion-exchange resins, and produce low flow rate streams for water of exceptional purity. These water streams can be used to displace water for loading samples onto concentrator columns, either directly or via another sample preparation device such as the CR-TC. RFIC-ESP and AutoPrep AutoPrep on the ICS-21 Ion Chromotography System utilizes RFIC-ESP techniques that simplify the analysis of trace levels of anions or cations. The use of EWPs to transfer large sample volumes to the concentrator column virtually eliminates background contamination, allowing for low ng/l concentrations of ions to be conveniently analyzed. Proportional volume loops enable injection of standards of concentrations 1 times higher than samples. Automated multilevel calibration is easily accomplished using Chromeleon software. Anion and cation determinations as low as 1 ng/l (ppt) are easily achievable. RFIC-ESP Advantageous for: Trace analysis of ions in power plant and semiconductor ultrapure water samples Determination of ions in concentrated acids and bases after neutralization Cation elimination from power plant borated waters with continuous regeneration of the trap device In-line neutralization of dilute samples Continuous desalting of an ion-exchange eluent for coupling to mass spectrometers Continuous desalting of ion-exchange eluents before fraction collection 9

Sample Filtration Remove Particulates to Protect Valuable Chromatography System Components Challenge Particulate blockage in system High backpressure Instrument downtime Microbial contamination Sample degradation Solution Dionex Filtration Devices Eliminates column contamination and high system back pressures Manual and automated methods Reduces cost of ownership Improves reliability and reproducibility of results Off-line Particle Filters Practical and easy to use Manually process samples with a.45 µm nylon membrane The off-line particle filter has a sterile syringe Luer fitting for injecting a sample through a.45 μm nylon filter. This device is perfect for filtering a limited number of samples, such as collecting samples in the field to comply with EPA requirements to filter microbes. In-line AS-DV Autosampler Vial Filters Automated, robust, inexpensive, and easy to use Efficient filtration for highly contaminated samples No sample carryover Used with the AS-DV high-performance autosampler, these 2 μm filtering devices sit atop the sample in either the 5 ml or.5 ml sample vial for automatic, highcapacity removal of particulates prior to injection. Because particulates settle to the bottom of the vial, the least contaminated sample is filtered first, thus preventing clogging and enhancing the filter s capacity. Individual filters are used for each sample, eliminating carryover concerns. In-line Filters Housing made of PEEK prevents ion contamination Minimal dead volume (~1.3 μl) for use in various in-line locations High pressure rating of 5 psi Several in-line filtering devices to match your application Two types of in-line sample filters are available: High-Capacity In-line Filter Cartridges Used in the sample and/or eluent line for high-capacity filtration, this in-line filter cartridge has 35, 5, and.45 μm filters. Low-Dead Volume In-line Filter Cartridges These in-line filter cartridges have.5 μm PEEK filter frits and provide low deadvolume sample filtration and added system protection when low particulate matter is expected. Kits Add Convenience for In-line Filtering A variety of in-line filter kits are available with everything needed to configure your IC system. 1

Specialized Systems Combustion Ion Chromatography Automated analysis of halogens and sulfur in petrochemicals, industrial materials, and consumer products Combustion IC enables anion analysis in a variety of difficult-to-process samples such as ores, printed circuit boards, solders, plastics, and petroleum products, among others. The sample combustion process automates conversion of a solid, liquid, or gaseous sample to an aqueous solution that can be injected directly into an IC system for fully automated sample processing. Samples are efficiently oxidized by heating to 1 C in an air or oxygen stream for just a few minutes. Volatile combustion products are carried by the combustion gas stream into a sparger where they are trapped in water. The sample is then loaded onto the IC injection valve and analyzed. The Combustion Ion Chromatography System comprises (from right to left) an autosampler, combustion unit, absorption unit, and ion chromatography system. Air Sampling System Automated analysis of volatile ionic constituents in air from emissions contributing to acid rain Volatile ionic constituents in air result from emissions ultimately become acid rain. Particulate-borne ions can be dissolved in precipitation. The URG air sampling system easily conducts air monitoring on a continuous basis. The system separates and collects particulate material and volatiles, and captures the volatile constituents using an aqueous sparging system. Particulates, dissolved in water automatically, and samples are then automatically injected and analyzed by ion chromatography. The system can be operated for days without user intervention. The URG Air Sampling System with integrated ion chromatographic analysis provide near real-time results. 11

Enjoy Industry-Leading Support Customer Support Centers for Dionex products are located in the Americas, Europe, and Asia. State-of-the-art laboratories are equipped with the full line of Dionex consumables, instruments, and software capabilities. Support Centers provide accessible locations for advanced training and enhanced application development capabilities. Users can attend these laboratories to learn new skills in addressing challenging applications, receive training and support, and discover new, innovative IC and sample preparation solutions. Corporate Headquarters Dionex Corporation 1228 Titan Way P.O. Box 363 Sunnyvale, CA 9488-363 Tel: (48) 737-7 Fax: (48) 73-943 Worldwide Sales and Service North America U.S./Canada (847) 295 75 South America Brazil (55) 11 3731 514 Europe Austria (43) 1 616 51 25 Benelux (31) 2 683 9768 (32) 3 353 42 94 Denmark (45) 36 36 9 9 France (33) 1 39 3 1 1 Germany (49) 6126 991 Ireland (353) 1 644 64 Italy (39) 2 51 62 1267 Sweden (46) 8 473 338 Switzerland (41) 62 25 9966 United Kingdom (44) 1276 691722 Asia Pacific Australia (61) 2 942 5233 China (852) 2428 3282 India (91) 22 2764 2735 Japan (81) 6 6885 1213 Korea (82) 2 2653 258 Singapore (65) 6289 119 Taiwan (886) 2 8751 6655 www.dionex.com Dionex products are designed, developed, and manufactured under an ISO 91 Quality System. 211 Dionex Corporation Chromeleon, InGuard, IonPac, OnGuard, are registered trademarks, and RFIC and RFIC-ESP are trademarks of Dionex Corporation. PEEK is a trademark of Victrex plc. LPN 291 PDF 6/11 Printed in U.S.A. Speed Simplicity Solutions