Long-Lifetime High-Yield Neutron Generators using the DD reaction

Similar documents
Physics Procedia 00 (2011) Union of Compact Accelerator-Driven Neutron Sources (UCANS) III & IV

Neutron Generators for Detection of Explosives and Illicit Materials

Recent Developments of Compact Neutron Generators at LBNL

Development of Advanced Neutron/Gamma Generators for Imaging and Active Interrogation Applications

A Report On DESIGN OF NEUTRON SOURCES AND INVESTIGATION OF NEUTRON BASED TECHNIQUES FOR THE DETECTION OF EXPLOSIVE MATERIALS

Pulsed Neutron Interrogation Test Assembly - PUNITA

nuclear material in cargo containers via active neutron interrogation

DEVELOPMENT OF ADVANCED NEUTRON INDUCED PROMPT GAMMA- RAY ANALYSIS SYSTEM FOR SURVEY OF ANTI-PERSONNEL MINES

Accelerator-Based Neutron Generator to Drive Sub-Critical Isotope Production Systems. Ross Radel, PhD President, Phoenix Nuclear Labs

Nuclear Science and Engineering Institute, University of Missouri, USA and Sidney Kimmel Institute for the Nuclear Renaissance

Shielded Scintillator for Neutron Characterization

Neutron Generators For Calibration

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Contrabands detection with a low energy electron linac driven photoneutron source

First on the South Pole, 14 December, 1911

COMPACT NEUTRON GENERATORS FOR MEDICAL, HOME LAND SECURITY, AND PLANETARY EXPLORATION*

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Detection of Highly Enriched Uranium Using a Pulsed IEC Fusion Device

Experiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Application of prompt gamma activation analysis with neutron beams for the detection and analysis of nuclear materials in containers

Measurement of Average Thermal Neutron Flux for PGNAA Setup

BWXT Y-12 Y-12. A BWXT/Bechtel Enterprise SMALL, PORTABLE, LIGHTWEIGHT DT NEUTRON GENERATOR FOR USE WITH NMIS

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

NSD GRADEL FUSION NEUTRON GENERATORS

Plasma Accelerator for Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS)

NUCL 3000/5030 Laboratory 2 Fall 2013

Physics Dept. PHY-503-SEMESTER 112 PROJECT. Measurement of Carbon Concentration in Bulk Hydrocarbon Samples

Amy Vong Sy. A dissertation submitted in partial satisfaction of the requirements for the degree of. Doctor of Philosophy

NIGAS. i o n. N B C D e t e c t. The Neutron Induced Gamma Spectrometer

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL

ARACOR Eagle- Matched Operations and Neutron Detector Performance Tests

Special Nuclear Material Detection Studies With The SMANDRA Mobile System

AGATA preamplifier performance on large signals from a 241 Am+Be source. F. Zocca, A. Pullia, D. Bazzacco, G. Pascovici

Seaborg s Plutonium?

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

DEVELOPMENT OF NEUTRON INTERROGATION TECHNIQUES TO DETECT DANGEROUS SUBSTANCES

Detection of explosives and fissile material based on neutron generators, survey of techniques and methods. M. Bruggeman

L-35 Modern Physics-3 Nuclear Physics 29:006 FINAL EXAM. Structure of the nucleus. The atom and the nucleus. Nuclear Terminology

EEE4106Z Radiation Interactions & Detection

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

A. Element 1. The number of protons and neutrons of an atom.

Radioactivity. Lecture 6 Detectors and Instrumentation

EBSS: Hands-on Activity #8. Operation of an electromagnetic isotope separator (EMIS) Dan Stracener Jon Batchelder

A Project for High Fluence 14 MeV Neutron Source

Neutron Based Techniques for the Detection of Illicit Materials and Explosives

Design of an Integrated Inspection System For Detection of Explosive and Illicit Materials

Cross-section Measurements of Relativistic Deuteron Reactions on Copper by Activation Method

Active Interrogation of SNMs by use of IEC Fusion Neutron Source

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

Utilization of Egyptian Research Reactor and modes of collaboration

NJCTL.org 2015 AP Physics 2 Nuclear Physics

Measurement of Hydraulic Conductivity, Porosity and Lithology by Neutron Activation Borehole Logging at high spatial resolution increments

Neutron induced reaction and neutron sources

FISSILE MATERIALS DETECTION VIA NEUTRON DIFFERENTIAL DIE-AWAY TECHNIQUE

POSITION SENSITIVE DETECTION OF CONCEALED SUBSTANCES EMPLOYING PULSED SLOW NEUTRONS

Compact D-D/D-T Neutron Generators and Their Applications. Tak Pui Lou

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

UNIT 13: NUCLEAR CHEMISTRY

D-D FUSION NEUTRONS FROM A STRONG SPHERICAL SHOCK WAVE FOCUSED ON A DEUTERIUM BUBBLE IN WATER. Dr. Michel Laberge General Fusion Inc.

Isotopes: atoms with the same Z but different A s (number of neutrons varies)

Development of portable neutron generators based on pinch and plasma focus discharges 1

THE SLOWPOKE-2 NUCLEAR REACTOR AT THE ROYAL MILITARY COLLEGE OF CANADA: APPLICATIONS FOR THE CANADIAN ARMED FORCES

TIIVISTELMÄRAPORTTI (SUMMARY REPORT)

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

Portable neutron generators of VNIIA and their applications

Chemistry 52 Chapter 11 ATOMIC STRUCTURE. The general designation for an atom is shown below:

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

Digital simulation of neutron and gamma measurement devices

OXEA - Online Elemental Analyzer

Fissile material experiments at the Device Assembly Facility

PINS Measurements of Explosive Simulants for Cargo Screening

Neutron Sources Fall, 2017 Kyoung-Jae Chung Department of Nuclear Engineering Seoul National University

He-3 Neutron Detectors

Science 10 Radioactivity Review v3

ACTIVATION ANALYSIS OF DECOMISSIONING OPERATIONS FOR RESEARCH REACTORS

Pulsed NeutroN technology: exploring New dimensions fastgradetm logging NeutroN tool P Cu Si Ni Fe NEUTRON TECHNOLOGY

TECHNICAL WORKING GROUP ITWG GUIDELINE ON LABORATORY APPLICATIONS OF HIGH-RESOLUTION GAMMA SPECTROMETRY

Name: Class: Date: SHORT ANSWER Answer the following questions in the space provided.

RADIOACTIVITY Q32 P1 A radioactive carbon 14 decay to Nitrogen by beta emission as below 14 x 0

Nuclear Physics Questions. 1. What particles make up the nucleus? What is the general term for them? What are those particles composed of?

Making Improvements to Today s Natural Gas Analysis Systems

Semiconductor Detectors

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

4. The mass of a proton is approximately equal to the mass of A an alpha particle C a positron. B a beta particle D a neutron

Multicusp Sources for Ion Beam Lithography Applications

New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

INSTRUMENTAL TECHNIQUE FOR THE DETECTION AND IDENTIFICATION OF RADIOACTIVE, FISSILE AND EXTRA HAZARDOUS SUBSTANCES

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

Emerging Capabilities for Advanced Nuclear Safeguards Measurement Solutions

Observation of Neutrons with a Gadolinium Doped Water Cerenkov Detector

A MONTE CARLO SIMULATION OF COMPTON SUPPRESSION FOR NEUTRON ACTIVATION ANALYSIS. Joshua Frye Adviser Chris Grant 8/24/2012 ABSTRACT

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

INTENSE PULSED NEUTRON GENERATION TO DETECT ILLICIT MATERIALS.

= : K A

Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

DIRECTIONAL NEUTRON SOURCE MODEL TEC- DNS- 3Z

Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier

Measurements of liquid xenon s response to low-energy particle interactions

Transcription:

1 AP/IE-01 Long-Lifetime High-Yield Neutron Generators using the DD reaction M. K. Fuller 1, M. A. Piestrup 1, C. K. Gary 1, J. L. Harris 1, G. Jones 1, J. H. Vainionpaa 1, D. L. Williams 1, J. T. Cremer 1, Adam Bell 2, Glenn McRae 2, Daniel Faber 3, B. A. Ludewigt 4, J. W. Kwan 4, J. Reijonen 4, K.-N. Leung 4 1 Adelphi Technology, Inc. 2 Carleton University 3 Heliocentric Technologies 4 Lawrence Berkeley National Laboratory michael.fuller@adelphitech.com Abstract. The Lawrence Berkeley National Laboratory and Adelphi Technology Inc. have developed a series of high-yield neutron generators using the D-D reaction with an axial geometry. They operate with a single ion beam and can have a small origin size useful for immediate moderation and a high concentration of thermal neutrons. The generator uses RF induction discharge to efficiently ionize the deuterium gas. This discharge method provides high plasma density for high output current, high atomic species from molecular gases, long life operation and versatility for various discharge chamber geometries. These generators are open systems that can be actively pumped for a continuous supply of deuterium gas further increasing the generator s expected lifetime. Since the system is open, many of the components, including the target, can be easily replaced. Pulsed and continuous operation has been demonstrated. In either mode of operation these generators have been used for Prompt Gamma Neutron Activation Analysis (PGNAA) and neutron activation analysis (NAA). Carleton University and Heliocentric Technologies are developing an Elemental Analyzer based on this neutron source. 1. Plasma Neutron Generators RF plasma neutron generators can produce intense neutron outputs of 10 10 n/s or greater with the deuterium-deuterium (D-D) reaction and 10 12 n/s or more with the deuterium-tritium (D- T) reaction. Based on core technology originally developed at Lawrence Berkeley National Laboratory[1] and further developed by Adelphi, these generators provide many times greater neutron output than other portable/transportable systems and have proven to be reliable and easily serviced. As shown in FIG. 1, plasma ion source neutron generators are simple diodes with a plasma source that generates the D+ ions that are then accelerated across a potential of ~100 kv to a titanium target. The target is biased to a negative voltage, while the plasma is at ground. The negative potential will then attract the positively charged particles to the target. The accelerated ions impinge onto a titanium coated copper target where 2.45-MeV D-D neutrons are generated through fusion reactions. The implanted hydrogen ions form titanium hydrates in the titanium matrix, thus trapping the deuterium atoms. When the generator is operating, the titanium layer is initially being loaded with deuterium and the neutron output is increasing with time; then after some minutes of operation the target is loaded by the incoming ions and the neutron output saturates to a stable level. While the ions are implanted to the target, heat is also deposited, which is removed from the target by cooling water.

2 AP/IE-01 Plasma Ion Source Accelerator Section D + Plasma Gate Ti-Target Electrode Electron Shroud HV FIG.1. Simple diagram of the principle components of the neutron generator using the D-D reaction. 1.1. Current Generators Adelphi Technology produces high intensity, neutron generators based on this technology. Adelphi currently makes devices with outputs of 10 8 (DD-108), 10 9 (DD-109) and 10 10 (DD- 110) fast neutrons per second. The model DD-109 is shown in Fig. 2. In addition, Adelphi has built a neutron generator specialized for the production of thermal neutrons for both prompt and delayed gamma neutron activation studies. These generators evolved from work Turbo Pump Generator Head n FIG. 2. The model DD-109 neutron generator head shielded inside a polyethylene housing. sponsored by the Department of Energy to develop a source for non-destructive testing at nuclear power plants [2]. The current products are all continuous-duty (non-pulsed) neutron generators using the deuterium-deuterium (D-D) fusion reaction. The neutron flux depends on the ion current and acceleration voltage. The voltage is easily controlled, and the current can be changed by varying the plasma density (both by varying the excitation and gas density). This allows continuous and precise control of the neutron output, and if the output is measured, a feedback loop can maintain a constant output flux over extended times. Because the voltage, gas pressure and RF excitation can be computer controlled, the neutron generators have been equipped with software to allow their control remotely and even over an internet connection. Generators using the D-D reaction have the further advantage that the system can be opened and serviced, greatly increasing its lifetime.

3 AP/IE-01 1.2. Generator Yield The yields of the three models have been measured for both continuous and pulsed operation. With one exception the measured yields are close to the expected calculated values. The DD- 108 and DD-109 have each been measured at the design values of 10 8 n/s and 10 9 n/s. At present the prototype DD-110 is operating at 1.8 x 10 9 n/s, below its desired output of 10 10 n/s. The present extraction iris area is smaller than that required for high yield production. The aperture area determines the ion beam current. At present the area limits the beam current to 15-18 ma. Larger irises are expected to achieve the desire yields. As shown in Fig. 3, the expected yield per ma is close to the desired calculated value. Pulsed operation is Efficiency (n/s-ma) 1.6E+08 1.4E+08 1.2E+08 1.0E+08 8.0E+07 6.0E+07 4.0E+07 6 mt Pressure DD-110 1.5 x 27 mm 2 iris Calculated 1750 W 2000 W 2.0E+07 0.0E+00 50 60 70 80 90 100 110 120 130 Acceleration Voltage (kv) FIG. 3. The efficiency of neutron production per ma of beam current as a function of accelerator voltage for two RF plasma powers. achieved by pulsing the 13.56 MHz RF supply to the plasma ion source. Pulse lengths greater than 100 µs can be achieved. 2. General Applications While the intensity of older-technology Penning diodes is sufficient for oil well logging, the greater output offered by Adelphi s plasma sources offers a larger range of laboratory research opportunities, including neutron activation studies, explosives detection, detection of special nuclear materials, neutron radiography, and chemical analysis. Detection of Conventional Explosives: Neutron interrogation is a valid method for determining the presence of concealed conventional explosives. There are several different techniques used, with effectiveness depending on the particular application. Whether thermal activation (measuring prompt or delayed gammas), fast neutron resonance/excited emission, or neutron radiography are used, increased flux will increase the range of detection a critical parameter. Some of these projects have benefited from Adelphi high-output source technology. The research efforts should yield a viable solution for shipping containers in the next few years.

4 AP/IE-01 Special Nuclear Material (SNM) Detection: Today, the detection and verification of SNM is an important challenge for the world community. As rogue states continue to develop and acquire nuclear weaponry, deterrence against use will employ new strategies and tools. While advances in passive detection systems will enhance the probability of detecting nonshielded or weakly shielded radioactive materials, the detection of shielded SNM and in particular shielded Highly Enriched Uranium (HEU) poses a significant challenge that is best addressed using active detection systems. These systems can be utilized to inspect cargo in shipping containers at seaports, border crossings, and air transport containers, or to be deployed as mobile inspection systems. For the pulse die-away technique for locating SNM, researchers have shown that it is important to radiate with neutrons below 10 MeV[7,8] from a pulsed source. For example, there is an important interference line from 16 O by the 16 O(n,p) 16 N reaction that produces a strong 6-MeV γ-ray line [8]. This interference is important when irradiating with 14-MeV neutrons from the D-T reaction since the reaction threshold neutron energy is 10 MeV. By operating with the D-D reaction, we can produce a neutron beam with energy of approximately 2.5 MeV. Adelphi has already attained the necessary pulsing regime. Chemical Industry: PGAA and NAA are established tools for elemental analysis and can potentially provide a complete picture of all contaminants in inorganic chemicals. Importantly, many applications require a higher neutron flux than currently possible with economically viable (much less than $1M) sources. Semiconductor Industry: Impurities in semiconductor materials may have a serious impact on the efficiency of electron transport throughout the chip matrix. In addition, sometimes there may be a need to dope the materials with infinitesimal amounts of a particular element. Contaminants are easily detected in inorganic matrices using PGAA/short-lived NAA. Having this level of analytical detail may offer insights into improving the semiconductor manufacturing or monitoring the doping processes. 3. Specific Application in a Neutron Activation Analysis (NAA) Mining Instrument Heliocentric Technologies, working with Carleton University, is developing an Elemental Analyzer. This device uses Prompt Gamma Neutron Activation Analysis (PGNAA) to determine the elemental composition of samples with no prior sample preparation. The device is designed to be compact while still accommodating samples that can weigh up to a few kilograms. A key component of the prototype Elemental Analyzer is an accelerator-based D-D Neutron Generator, which provides a high neutron flux for irradiating samples. Most commercially available PGNAA systems use either research reactors or high yield, neutron-emitting radioisotopes. The accelerator-based neutron generator provides the ability to throttle the intensity of the neutron field, or even terminate or pulse the neutron production on command. This is a huge advantage over other neutron sources in term of safety (even the fuel source is not radioactive), serviceability, flexibility and mobility. The other system components are the radiation shielding and neutron moderator, a High- Purity Germanium (HPGe) semiconductor photon detector with electronics, and the data processing algorithms. FIG. 5 shows the pre-production concept of Elemental Analyzer.

5 AP/IE-01 3.1. Instrument and Test Sample Description Heliocentric s Elemental Analyzer is currently in the advanced prototype phase of design. A series of tests was performed in November 2008 in order to validate the prototype s performance targets. A set of calibration samples, as well as representative samples from various customers, were used to assess the prototype s performance. FIG.5. Pre-Production concept of the Elemental Analyzer. The electronics rack and cooler (left), the Adelphi neutron generator, moderator/shielding and detector (center, translucent), command station and operator (right). The neutron generator supplied by Adelphi Technology was the Model DD-109. The device uses a deuterium-deuterium reaction to produce large quantities of 2.45 MeV mono-energetic neutrons. The neutron yield of the generator was on the order of 10 9 n/s isotropic. The average flux in the test sample is estimated to be 10 5 n cm -2 s -1. The test chamber (approximately 1.5 L volume), where the test samples are placed, was surrounded by a moderating material to optimize the thermal neutron flux within the sample. A shielding material surrounded the Analyzer components in order to protect the operators from the radiation and to limit the incursion of background radiation. When the nucleus of an element becomes activated by thermal neutrons it will emit photons of characteristic energies. A coaxial n-type HPGe detector (~ 100 cm 3 crystal volume) was used to detect that characteristic radiation. A digital Multi-Channel Analyzer (MCA) was used to record and bin the detector signals. The data from the MCA is simply a spectrum containing the number of counts registered over a range of photon energies. Calibration of the Elemental Analyzer allows the software to convert numbers of counts to grams of material, with further processing to accommodate samples of a variety of compositions and physical and material properties. Calibration samples consisted of pure elements and ranged in size from 1 to 64 g. These samples were used to establish a relationship between the number of counts registered by the detector and the mass of the sample present in the Analyzer test chamber. The customer samples that were tested include mining rock samples, powder, granules and irregularlyshaped lump samples. FIG. 6 contains examples of the mineral samples.

6 AP/IE-01 (a) (b) (c) FIG. 6. Examples of mining samples tested in Heliocentric s prototype Elemental Analyzer. Split rock samples (a), Powder (b) and lump samples (c). 3.2. Results of Testing The primary purpose of this series of tests was to verify the scalability of the design concept by validating the prototype s target detection limits and measurement accuracy. Previous tests had been conducted with a neutron source 1000 times weaker than the accelerator-based neutron generator. These tests allowed an assessment of the impact of those differences on the system performance. Calibration samples were loaded into the test chamber and a photon spectrum was recorded while the samples were simultaneously bombarded by neutrons from the neutron generator for 1000 seconds (live time, not real time). The PGNA spectra from the calibration samples were post-processed to produce calibration curves for each individual element (see FIG. 7). The relationship between count rate and sample mass is necessary to interpret the customer sample spectra. The customer samples experienced the same test procedure as the calibration samples. The post-processing algorithms calculated the quantity of material present in each of the samples using the calibration data and accounting for each individual sample s unique physical and material properties. The compositions of the customer samples measured with the prototype Elemental Analyzer were compared with the known sample compositions provided by the sample suppliers to assess the Elemental Analyzer s accuracy (see FIG. 8). Improvements to accuracy can be obtained through longer test times for the calibration samples; time constraints on testing prevented such considerations in this case. The detection limit (DL) has been defined as the level at which a measurement has a +/- 100% precision for a pure calibration sample. For example, if the DL is 5 grams and a 5 gram calibration sample is tested, over many tests the average result will be 5g with a standard deviation of 5g. The accuracy of the instrument is such that all measurements above the DL will be within 15% of the true value 95% of the time. Detection limits for the Elemental Analyzer were calculated for eight elements of interest (see TABLE 1). The current Elemental Analyzer is a prototype designed to validate intermediate scalability of the design. The final, production-ready instrument will require further scaling in terms of shielding, data processing and detector technology. The final estimated detection limits are also shown in TABLE 1.

7 AP/IE-01 FIG. 7. Calibration curve for pure Nickel. The count rate has been adjusted to account for sample physical properties. FIG. 8. A graph comparing measured mass versus the known sample mass for sulfur in customer samples. All measurements are within +/- 15% of the actual values. TABLE 1 DETECTION LIMITS FOR HELIOCENTRIC S ELEMENTAL ANALYZER Element Detection Limit: prototype Detection Limit: target for final instrument Aluminum Al 0.2% (Delayed GNA) 0.02 % (Delayed GNA) Arsenic As N/A 0.1 % Cobalt Co 0.5% 0.05 % Copper Cu 0.6% 0.1 % Chlorine Cl N/A 0.05 % Chromium Cr 0.9% 0.1% Iron Fe 1.5% 0.1% Nickel Ni 0.5% 0.05 % Silver Ag N/A 0.01 % Sulfur S 0.5% 0.1 % Zinc Zn 3% 0.2 % Uranium U N/A 0.01% (DNC/PFN) Integration time t 1,000 s 300 s Absolute accuracy +/- 15% 5% 3.3. Deduction from Prototype Testing The compact Elemental Analyzer being developed by Heliocentric Technologies employs PGNAA to quickly and accurately determine the elemental composition of samples without any sample preparation. It has been demonstrated that the Elemental Analyzer, incorporating

8 AP/IE-01 a D-D neutron generator with 10 9 isotropic output, can achieve the target detection limits and accuracy for the current prototype between 5 and 15 grams (0.5% to 1.5% in 1kg samples). During a series of tests in November 2008, the prototype Analyzer was able to provide the elemental compositions of an array of samples including Minerals, Powder, Granules and various lump samples. These measured elemental compositions were within the acceptable range of error of the known sample compositions. Future work includes refinements to the design and algorithms to allow the instrument to achieve the target performance for the final production instrument: detection limits between 0.05 and 0.1 grams for the elements of interest. 4. Conclusion RF plasma neutron generators can produce intense neutron outputs with the deuteriumdeuterium (D-D) reaction. Because the energy of the neutrons produced, moderation to thermal energies can be achieved in reasonable geometries. This capability offers a large range of laboratory research opportunities and industrial applications. A particularly promising application is for the elemental composition analysis of rock core samples.

9 AP/IE-01 Appendix 1: References [1] J. Reijonen, N. Andresen, F. Gicquel, R. Gough, M. King, T. Kalvas, K.-N. Leung, T.- P. Lou, H.Vainionpaa, A. Antolak, D. Morse, B. Doyle, G. Miller and M. A. Piestrup, Development of Advanced Neutron/Gamma Generators for Imaging and Active Interrogation Applications, Proceedings of SPIE Vol. 6540-55 (SPIE, Orlando, FL, 2007). [2] J. T. Cremer, Principal Investigator DOE Phase II STTR (DE-FG02-04ER86177), High Brightness Neutron Source for Radiography, (7/13/05-07/10/2007). [3] M. A. Piestrup, Principal Investigator Phase I STTR (DE) Gamma Ray Calibration Source, DE-FG02-07ER86294. [4] J. W. Kwan, R. Gough, B. A. Ludewigt, M. Regis, R. P. Wells, J. H. Vainionpaa, A 2.45 GHz High Current Ion Source for Neutron Production, High Energy Physics and Nuclear Physics, (2007). [5] J. H. Vainionpaa, R. Gough, M. Hoff, J. W. Kwan, B. A. Ludewigt, M. J. Regis,J. G. Wallig, R. Wells, Microwave ion source and beam injection for an accelerator-driven neutron source, Proceedings of PAC07, Albuquerque, New Mexico, USA TUPAS045 (2007). [6] Qing Ji, Y. Wu, M. Regis, J. W. Kwan, Compact Portable Microwave Driven Neutron Generator, LBNL (2008). [7] G J Roach and J R Tickner Performance Tests on Adelphi Neutron Generator Carried out during Overseas Visit 18-22 June 2007 CSIRO Report DMR-3252 (2007). [8] D. Slaughter, M. Accatino, A. Bernstein, J. Candy, A. Dougan, J. Hall, A. Loshak, D. Manatt, A.Meyer, B. Pohl, S. Prussin, R. Walling, D. Weirup, Detection of Special Nuclear Material in Cargo Containers Using Neutron Interrogation, Lawrence Livermore National Laboratory, UCRL-ID-155315, August 2003.