Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

Similar documents
Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

10 samples per second

Temperature Sensor -40 C to 140 C

Thermocouple TC-K Sensor 0 C to 1200 C

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Ion Selective Electrode Probe

GENERAL INSTRUCTIONS GENERAL PREPARATION

Chemistry MultiMeasure Sensor PS-2170

GENERAL INSTRUCTIONS GENERAL PREPARATION

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

Operating Instructions for Ammonium ISE Specifications

EXPERIMENT 6. Properties of Buffers INTRODUCTION

Experiment C-10 Titration of a Strong Acid and a Strong Base

1) A ph/mv meter or an ion meter, either line operated or portable.

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

COLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY NITRATE ION ELECTRODE INSTRUCTION MANUAL

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Bante210 Benchtop ph Meter Instruction Manual

Kinetics of Crystal Violet Bleaching

POTASSIUM ION SELECTIVE ELECTRODE

Experiment 7 Buffer Capacity & Buffer Preparation

The Cole-Parmer Nitrate Ion Electrodes are used to quickly, simply, accurately, and economically measure nitrate in aqueous solutions.

[Agilent Technologies] [Electrochemistry Products] Quick Reference

NITRATE ION SELECTIVE ELECTRODE

COLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Guide to ph Analysis.

MEASUREMENT: PART II

symphony Multisensor Probes

iworx Sample Lab Experiment GB-2: Membrane Permeability

OPERATING INSTRUCTIONS

GENERAL INSTRUCTIONS GENERAL PREPARATION

6 Acid Base Titration

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

Use a pipet bulb when pipeting cyanide solutions, as these solutions are highly toxic.

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

LABORATORY INVESTIGATION

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

Spectrometer User s Guide

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Experimental Procedure. Lab 406

Rapid RH Portable ph Meter. User's Manual

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml)

ph 5 Meter Manual The LaMotte 5 Series

Ion Selective Electrodes

ph Probe ReallyEasyData com

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

symphony Reference Electrodes

Acid Rain. Computer OBJECTIVES

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

DOC /2013, Edition 1. User Manual

phoenix Electrode Company CARBON DIOXIDE GAS-SENSING ELECTRODE INSTRUCTION MANUAL 1. A ph/mv meter or an ion meter, either line operated or portable.

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA

CALCIUM SELECTIVE ELECTRODE

Common Acids and Bases

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL

Determining the Concentration of a Solution: Beer s Law

STANDARD OPERATING PROCEDURE

Zetasizer Nano-ZS User Instructions

COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Diffusion through Membranes

perfection Guidebook perfection Combination Iodide Electrode Successful Ion Measurement

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Potentiometric measurement of ph

Titration of a strong acid with a strong base with Cobra4

Bante900P Portable Multiparameter Water Quality Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Lab 5 Enthalpy of Solution Formation

Determination of an Equilibrium Constant

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA. Background

PH700 Benchtop ph Meter Instruction Manual

WEEK 2 EXP. 9 EVALUATION OF METHODS FOR DETECTING AMMONIUM: ION SELECTIVE ELECTRODES AND SPECTROSCOPY

NH 3 -selective electrodes

SCIEX Cation Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

COLE-PARMER INDUSTRIAL CALCIUM ION ELECTRODE INSTRUCTION MANUAL

Use quantitative and qualitative analyses to identify the powder in Mr. Orlow s car.

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL

Basic Analytical Techniques, Calorimeter, and Conductivity Meter

Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant

Experiments in Chemistry

EXP. 9 EVALUATION OF METHODS FOR DETECTING AMMONIUM: ION SELECTIVE ELECTRODES AND SPECTROSCOPY

User instructions. Gel filled ORP/Redox electrode: Model MTC10101, MTC10103, MTC10105, MTC10110, MTC10115 or MTC10130

Chemical Equilibrium: Finding a Constant, Kc

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Ammonia Gas Sensing Combination Electrode

Ammonia Gas Sensing Combination Electrode

Transcription:

imagine explore learn Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A Overview Ammonium ions (NH 4+ ) can be found in fertilizer, cleaning products, processed meats and in the waste of animals. In water, at high concentrations, it can be a dangerous pollutant. The Ammonium sensor measures the concentration of ammonium ions in aqueous solutions. The Ammonium Sealed Electrode Sensor can be connected to all types of einstein data loggers. Typical experiments Water Quality Water Quality Studies Chemistry

Effectiveness of Fertilizers Level of Ammonium in Processed Meat Corrosiveness of Ammonium in Canned Foods How it works The Ammonium sensor contains a Permafil (non-refillable) electrode containing an oxidized form of bromide inside a membrane. When inserted into a solution containing Ammonium molecules the Ammonium in the solution is attracted to the oxidized Ammonium in the membrane. By measuring the electrical potential of this attraction the sensor can determine the level of Ammonium in the solution. Because they only attract other Ammonium molecules sealed electrode sensors work well even in solutions containing numerous elements. Sensor specification Concentration Range: 1x 10-6 to 1 M (0.014-14,000 ppm) Resolution (12-bit): 0.15 mv Minimum Sample Size: 5 ml in a 50 ml beaker Default Sample Rate 10 samples per second ph Range: 4 to 10 ph Temperature Range : 0 to 50 C Reproducibility : ± 4% Electrode Resistance 1 to 4 MΩ Interfering Ions K +, Na + Note: Sensor cables sold separately Contents The Ammonium Sealed Electrode Sensor comes equipped with: The Ammonium Sealed Electrode Sensor ISE (Ion Selective Electrode) Amplifier (1) 1 oz. NH + 4 Ionic Strength Adjuster (ISA) (AJNH41) (1) 1 oz. NH + 4 10 ppm as N Standard (SD2052) (1) 1 oz. NH + 4 1000 ppm as N Standard (SD2002 / SDNH42) Solutions ISA 1M NaCl: 58.443g NaCl in 1000mL DI water 10ppm NH 4 + as N Standard (0.0714 M NH 4+ ): 38.19 mg NH 4CI in 1000 ml DI water 1000 ppm NH 4 + as N Standard (0.0714 M NH 4+ ): 3.819 g NH 4CI in 1000 ml DI water Experimental set up Electrode Preparation 1. Remove the plastic protective vial from the tip of the electrode and gently shake the electrode downward like a thermometer to remove any air bubbles trapped inside. Caution: Do not touch the PVC membrane with your fingers. 2. Rinse the electrode with DI water, blot dry. Do not rub dry. 3. Condition the electrode in the provided 10 ppm NH 4 + as N standard solution for 30 minutes.

4. After the conditioning period, rinse the tip of the electrode with DI water and blot dry. 5. The electrode is now ready to use. This sensor must be calibrated before use (see the Data Logging, Calibrating and Analysis below). Two solutions of different concentrations (depending on the range of measurements) are used to calibrate the electrode. ISA is added to all solutions to ensure that the samples and the standards have the same ionic strength. In addition to the aforementioned contents you will also need: Wash Bottle with Distilled (Dl) or deionized water. Several clean beakers. 1mL, 10mL pipettes. Data logging, Calibrating and Analysis MiLAB TM Android & IOS 1. Take your einstein Tablet or pair your einstein LabMate with your Android or ios tablet via Bluetooth 2. Insert the electrode into the ISE amplifier 3. Insert the ISE amplifier cable into one of the sensor ports 4. Launch MiLAB 5. MiLAB will automatically detect the ISE amplifier and show it in the Launcher View 6. Tap ISE amplifier and select the Ammonium electrode 7. Make sure the icon is checked ( ) to enable it for logging Calibration in MiLAB Preparing the calibration solutions 1. Add 10 ml of the 10 ppm solution into a 50 ml beaker. 2. Add 0.2 ml of ISA and stir thoroughly. 3. Add 10 ml of the 1000 ppm solution into a 50 ml beaker. 4. Add 0.2 ml of ISA and stir thoroughly. Calibrating the sensor 1. Tap the Settings button next to the sensor s name and then Manual Calibration

2. Prepare the electrode as described in Electrode preparation above 3. Tap the Real Reading box of Point 1 4. Enter the value 10 5. Rinse the electrode with DI water, blot dry and place in the beaker with the 10 ppm solution. Wait for a stable reading, and then tap the Lock icon 6. Tap the Real Reading box of Point 2 7. Enter the value 1000 8. Rinse the electrode with DI water, blot dry and place in the beaker with the 1000 ppm solution. Wait for a stable reading, and then tap the Lock icon 9. Tap Calibrate 10. You are ready to run your experiment Note: It is best to calibrate the electrode with one Real Reading below your expected reading and one Real Reading above your expected reading. For example if you expect a reading of around 100 ppm it is best to calibrate with one Real Reading below 100 ppm and one Real Reading above 100 ppm Note: You can prepare your own ppm solutions for calibration, using the strength of your solution as the Real Reading MiLAB Desktop 1. Pair your einstein LabMate with your PC, MAC, or Linux machine via Bluetooth, or connect it via the USB cable (found in the einstein LabMate box). 2. Insert the electrode into the ISE amplifier 3. Insert the ISE amplifier cable into one of the sensor ports 4. Launch MiLAB 5. MiLAB will automatically detect the ISE amplifier and show it in the Current Setup Summary window

6. Click Full Setup, located at the bottom of the Current Setup Summary window to set which ISE electrode you are using and to program the data logger s sample rate, number of samples, units of measurement, and other options Calibrating in MiLAB Desktop Preparing the calibration solutions 1. Add 10 ml of the 10 ppm solution into a 50 ml beaker 2. Add 0.2 ml of ISA and stir thoroughly 3. Add 10 ml of the 1000 ppm solution into a 50 ml beaker 4. Add 0.2 ml of ISA and stir thoroughly 1. Start MiLAB ( ) and select the Ammonium electrode as described above. 2. Under the Calibrate column tap Set to bring up the Calibration menu

3. Prepare the electrode as described in Electrode preparation above. 4. Tap the Real Reading box of Point 1 5. Enter the value 10 6. Rinse the electrode with DI water, blot dry and place in the beaker with the 10 ppm. Wait for a stable reading, and then click the Lock icon 7. Tap the Real Reading box of Point 2 8. Enter the value 1000 9. Rinse the electrode with DI water, blot dry and place in the beaker with the 1000 ppm solution. Wait for a stable reading, and then click the Lock icon 10. Click Calibrate 11. Tap the Run button ( )on the main toolbar of the Launcher View to start logging Note: It is best to calibrate the electrode with one Real Reading below your expected reading and one Real Reading above your expected reading. For example if you expect a reading of around 100 ppm it is best to calibrate with one Real Reading below 100 ppm and one Real Reading above 100 ppm Note: You can prepare your own ppm solutions for calibration, using the strength of your solution as the Real Reading Maintenance and Electrode Storage Short Term: Rinse the electrode thoroughly with Dl water and place the tip in a diluted standard solution (10 ppm) between measurements. Long Term: Rinse the electrode thoroughly with Dl water, blot and store dry. Replace the cap to protect the sensing element. Follow procedures in the sections Electrode Preparation before using the electrode again.

Troubleshooting If the electrode reading is not within the normal range, the following procedure may restore the electrode. 1. Soak the electrode in the 10 ppm NH4+ as N standard solution for 2 hours before use. 2. Repeat the procedure outlined Electrode Preparation again. Technical support For technical support, you can contact the Fourier Education's technical support team at: Web: /support Email: support@fourieredu.com Phone (in the US): (877) 266-4066 Copyright and Warranty All standard Fourier Systems sensors carry a one (1) year warranty, which states that for a period of twelve months after the date of delivery to you, it will be substantially free from significant defects in materials and workmanship. This warranty does not cover breakage of the product caused by misuse or abuse. This warranty does not cover Fourier Systems consumables such as electrodes, batteries, EKG stickers, cuvettes and storage solutions or buffers. ALBERT EINSTEIN and EINSTEIN are either trademarks or registered trademarks of The Hebrew University of Jerusalem. Represented exclusively by GreenLight. Official licensed merchandise. Website: einstein.biz