Marine Engine Market Segment

Similar documents
Agilent Oil Analyzer: customizing analysis methods

Process Analytical Technology Diagnosis, Optimization and Monitoring of Chemical Processes

Spectroscopy in Transmission

S8 TIGER Series 2 for ASTM D 6443

Data Sheet / Instructions. Dewpoint MeterO

Dewpoint Meter Data Sheet / Instructions

The DialPath Solution an Easier Way to Analyze Liquids By FTIR. Yanqia Wang, Ph.D. Application Engineer - FTIR Agilent Technologies May 7, 2015

Agilent Cary 630 FTIR sample interfaces combining high performance and versatility

473-SHX Dew Point Mirror

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Comparison of HCD5000 DewPoint Duo to Condumax II

Chemistry Instrumental Analysis Lecture 15. Chem 4631

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

UV3000. Accurate, precise, and portable ambient gas point analyzer

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Determination the elemental composition of soil samples

Introduction to Fourier Transform Infrared Spectroscopy

FTIR Spectrum Interpretation of Lubricants with Treatment of Variation Mileage

ISM Evolution. Elscolab. Nederland BV

ABX Pentra 400. Clinical Chemistry System. Up to 420 tests/hour 55 Assays Validation Station

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR

OXEA - Online Elemental Analyzer

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FT-IR

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

Introduction to Fourier Transform Infrared Spectroscopy

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

Burning a Hydrocarbon II

OXITEST Oxidation Test Reactor


UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Minimum (-31) every 10 s -35 (-31)

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

Optical In-line Control of Web Coating Processes with UV-VIS-NIR Spectroscopy. AIMCAL Europe Web Coating Conference Peter Lamparter

Reprinted from February Hydrocarbon

High Power Factors and Contaminants in Transformer Oil

novaa 800 D Atomic Absorption Spectrometer

ISEmax CAM40/CAS40. Technical Information

Introduction to Blackbody Sources

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

MULTICHANNEL NADIR SPECTROMETER FOR THEMATICALLY ORIENTED REMOTE SENSING INVESTIGATIONS

Name Class Date. Copyright Houghton Mifflin Harcourt Publishing Company. When working with this Lab Report file, remember to save often.

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Q1. The chart shows the processes involved in the manufacture of nitric acid from ammonia.

110 Lowell Rd Hudson, NH USA Tel:


L E A. Laser Elemental Analyzer

Ruby crystals and the first laser A spectroscopy experiment

SPECTROPHOTOMETERS. Visible and UV-Visible

PAA-ANALYZERS PRINCIPLE OF OPERATION

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

Industrial In-line and Multi Component Monitor Using Absorption Spectroscopy and Its Application

An Introduction to Insulation Resistance Testing

Mercury Stack Monitor SM-4

Applications of Voltaic Cells

Chemical reactions. C2- Topic 5

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Residual Chlorine Monitor

New Instruments from GRIMM

ADI 2040 Process Analyzer

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

AP Chemistry A Review of Analytical Chemistry

473 Dew Point Hygrometer

Information Technology Solutions Neptune Datasheet

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

Defining quality standards for the analysis of solid samples

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

PAPER No. 12: ORGANIC SPECTROSCOPY MODULE No. 7: Instrumentation for IR spectroscopy

Microcare LCD Solar MPPT User Documentation

BioDrop DUO dsdna Application Note

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

473 Dew Point Hygrometer

Reference Standards Page 156 For calibrating your spectrometer. PIKECalc Page 159 For FTIR sampling computations

Direct reading aerosol monitors

ICSE Board. Class X Chemistry. Board Paper Time: 1½ hrs Total Marks: 80

PYCKO SCIENTIFIC LIMITED

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

Jasco V-670 absorption spectrometer

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry

One-hand ph/temperature measuring instrument

THE APPLICATION OF PROCESS MASS SPECTROMETRY TO FUMED SILICA PRODUCTION

Experiment 14 It s Snow Big Deal

Hydrogen & Chlorine monitoring for the Chlor-Alkali Industry

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Traceable UV-Vis Reference Materials

Electricity. Electrolysis. Current and the transport of charge DETERMINATION OF THE FARADAY CONSTANT BASIC PRINCIPLES

DSA 5000 M. Density and Sound Velocity Meter. ::: Unique Density & Concentration Meters

Transcription:

Marine Engine Market Segment Over the recent years regulators have imposed more stringent regulations on the emissions of marine engines for example low sulphur emissions as defined in MARPOL. New engines are now designed to comply with the Tier II NOx regulations and Energy Efficiency Design Index (EEDI) guidelines. These regulations together with the constant requirement to reduce operation costs have resulted in the design of more fuel efficient ship engines. The new generation of ship engines have longer piston strokes and operate at a lower temperature that is below the dew point and at higher pressure compared to pre vious generations of ship engines. Previously, sulphur in the engine was in a gas form as SOx. Now, because of the lower temperature the H2S can react with water, that condense on the liner of the cylinder walls, to form sulphuric acid, resulting in corrosion on the liner surface. This process is called cold corrosion and it creates excessive wear of the liner material. How serious is cold corrosion for my engine? Cold corrosion is at its most serious in the latest engine designs but also impacts earlier engine designs modified for part-load or low-load operation (known as slow steaming, where vessels may operate as low as 10% load). Many ship operators have switched over to slow steaming in recent years to save fuel costs and as a consequence the engine management and oil condition monitoring becomes increasingly important for ship operators. The key parameters that have a direct influence on the cold corrosion potential are the cylinder temperature, the base number of the cylinder oil, the load factor, lubricator feed rate, sulphur content of the fuel that is used. All these parameters are influenced by each other and it is important to identify the optimum working point of the engine where all the parameters are ba lanced and stable. The IR Sphinx spectrometer range is a very useful tool to ensure that the engine operates efficiently. This can be achieved by analysing the cylinder oil at a suitable position, i.e. the underside of the piston to extract relevant oil parameters such as Total Base Number, water content, oxidation level etc. The spectrometer can either be configured as an inline marine oil analyser or a portable ATR unit can be used to carry out frequent spot-checks of the cylinder oils. In both cases the marine oil analyser will provide an accurate picture of the stats of the oil and the information obtained can be used to fine tune the engine to achieve the lowest possible operating costs. The marine oil analyser does not require any consumables and does not require the use of any wet chemical substances. The results will be available within minutes and can be used as a real time feedback for the ship engineers. With the data being available in digital format it can be presented to an operator in form of a traffic light system or engineers can study the data in detail to gain a further understanding of how the fuel type (i. e. using high sulphur fuel), the lube oil feed rate or the total base number of the cylinder oil influences the lifetime of the cylinder. Applications notes for these parameters can be found on our website: TBN, Water, Soot, Oxidation

Mid-infrared spectroscopy Mid infrared spectroscopy (Mid IR) is a powerful technique for measuring the concentration of organic molecules. Mid-IR spectroscopy covers the absorption of light by a sample in the range from 2000 nm to 12000 nm. In this wavelength range the absorption of light at a specific wavelength can be linked unequivocally to a certain molecular structures that subsequently identifies the molecule. In the Mid-IR wavelength region each molecule absorbs light at a molecule characteristic wavelength and the amount of light absorbed is a measure of the concentration of the particular molecule in a sample. As different molecules absorb light at different characteristic wavelength in the Mid-IR wavelength region the measurement of a mid-infrared absorption spectrum from 5500 nm to 11000 nm can be used to identify the existence and the concentration of a multitude of different molecules in a sample. present in the cuvette. This is called the sample measurement. The difference between the background measurement and the sample measurement originates from the light that is absorbed by the sample and it is called the absorption spectrum of the sample. The working principle of the ATR mode is shown below. Light from a broadband emitter is coupled into an ATR crystal. The geometry of the crystal is designed in such a way that the light bounces through the ATR crystal (total internal reflection) and is coupled out on the other side where the light is again split up into discrete wavelengths by a grating and detected by an infrared line array. Oil ATR LVF Mid-infrared spectroscopy is either carried out in transmission mode or in ATR mode where ATR stands for Attenuated Total Reflection. IR Emitter IR Sensor IR Emitter Cuvette LVF IR Sensor If now a sample is placed on top of the ATR crystal the refractive index of that sample is different to that of air resulting that the light penetrates which each bounds a certain distance into the sample before it is reflected back into the ATR crystal (evanescent waves). Which each bounce certain wavelength of the light are absorbed by the sample sitting on top of the ATR crystal. In transmission mode (see picture above) the light from a broadband emitter is directed through a cuvette (which contains the sample) onto a grating. The grating splits out the light into more discrete wavelength (similar to a rainbow) and the light then falls onto an infrared sensor (line array) where each pixel corresponds to a specific wavelength. A midinfrared absorption spectrum is recorded by first recording the signal levels of each of the pixels of the line array without a sample being present in the cuvette. This is called a background measurement. Subsequently the measurement is repeated but with a sample being An absorption spectrum of a sample in ATR mode is obtained in the same way as in transmission mode. First a measurement is taken without a sample being present on the ATR crystal (background measurement). Subsequently a sample is placed onto the ATR crystal and the sample measurement is taken. The difference is again called the absorption spectrum of the sample. In principle both transmission mode and ATR mode provide exactly the same absorption spectrum of the sample and it depends on the exact application which measurement mode is best suited.

Oil conditioning monitoring based on Mid-IR spectroscopy Many different substances can be used to lubricate a surface. Oil and grease are the most common. Grease is composed of oil and a thickening agent to obtain its consistency, while the oil is what actually lubricates. Oils can be synthetic, vegetable or mineral-based as well as a combination of these. The application determines which oil, commonly referred to as the base oil, should be used. In extreme conditions, synthetic oils can be beneficial. Where the environment is of concern, vegetable base oils may be utilized. Lubricants containing oil have additives that enhance, add or suppress properties within the base oil. The amount of additives depends on the type of oil and the application for which it will be used. Typical additives are anti-foam additives, anti-wear additives and antioxidants. The only problem with additives is that they can be depleted, and in order to restore them back to sufficient levels, generally the oil volume must be replaced. As such a replacement of the lubricants can be very expensive (either directly due to the high costs of the lubricant or indirectly due to downtime of the engine and lost earnings) it is desirable to have a cost effective oil conditioning monitoring sensor that provides accurate and reliable information about the condition of the oil. Mid-IR spectroscopy is well suited to oil condition analysis. During the aging of the oil, different decomposition and conversion processes occur at the molecular level resulting in changes in the absorption spectrum. As these aging processes introduce changes in the absorption spectra at many different characteristic wavelengths one IR spectrum of an oil sample can provide accurate and conclusive information about the status of the oil and about it can help to identify the root cause of the aging mechanism as the characteristic wavelength, where the change in absorption is observed, is linked to one specific and uniquely identifiable molecular structure. The oil aging or degradation process can be attributed to three key aging mechanisms: oil degradation additive depletion contamination Base oil degradation is predominantly driven by an oxidation processes. It can be viewed as the chemical breakdown of the base oil molecules with oxygen as a reagent. The principle source of oxygen is air. There are a number of parameter that accelerate the oxidation process such as high temperature, wear particles, water and other contaminants. Te brake down of the base oil involves a number of chemical reactions that produce acid compounds which undergo further re actions to form polymeric compounds resulting in varnish, sludge and other deposits. Typical oil condition parameters related to base oil degradation are: Oxidation, Total Acid Number (TAN), Total Base Number (TBN), nitration and sulphation. Additives are part of any modern lubricant solution. Additives are functional groups, usually with central ions such as zinc, molybdenum, magnesium etc. that are suspended into the base oil to enhance the overall performance of the lubricant. Typical additives are used to combat the main degradation mechanism of the base oil and they address areas such as anti-foam additives, anti-wear additives and anti-oxidants additives. During the oil ageing process the concentration of additives within the lubricant decreases and once the additive concentrations have reached a lower threshhold concentration the degradation of the lubricant becomes inevitable. Monitoring the concentration levels of the different additives is therefore very important to get a good understanding of the current condition of the oil. Typical additives used to neutralise the key degradation mechanisms are molecules with central ions of

Oil Condition Sensors based on Mid-IR spectroscopy zinc, molybdenum, phosphorus, calcium, magnesium, barium or sodium. Again these molecules have uniquely identifiable characteristic absorption wavelength and by way of measuring the infrared absorption spectrum of an oil sample the respective concentrations of each of the additives can be determined. Oil contamination is often caused by foreign substances such as water, glycol, diesel, petrol or foreign oils. Each of these substances have unique characteristic absorption wavelength and can therefore easily being identified. This is shown in the figure below for water contamination of a oil between 250 5000 ppm. A characteristic water absorption peak at 1644 cm -1 develops as the water concentration in oil increases. The oil condition sensor of the IR Sphinx series detects the three major oil degradation mechanism simultaneously. The standard oil condition parameters, that are commonly obtained by laboratory based analysis, are calculated from the measured IR spectra. The sensor is based on a spectral apparatus that is constructed with no moving parts, which makes it durable and virtually maintenance free. Meaningful oil condition parameters are calculated from the recorded spectra by a previously built oil-specific calibration (chemometric model). The sensor also does not require any consumables or wet chemistry which significantly enhances the safety aspect and reduces long term operation costs. One sensor can be configured to measure all parameters that are relevant to the oil condition monitoring and maintenance of marine engines. In addition to portable systems for rapid on-site analysis, device models for use in the laboratory are available as well as rugged field installations for Mid-IR spectroscopy is able to provide information (qualitatively and quantitatively) about the three different aging mechanism. By a detailed analysis of the mid-infrared absorption spectrum of an oil sample the oil condition can be characterised and specific degradation mechanism can be identified and analysed. In addition to portable systems for rapid on-site analysis, device models for use in the laboratory are available as well as rugged field installations for inline operation.

IR Sphinx ATR product portfolio and technical specification Spectrometer ATR Lab ATR Portable ATR Industrial Spectral range 2.5 5.0 μm 5.5 11.0 μm 2.5 5.0 μm 5.5 11.0 μm 2.5 5.0 μm 5.5 11.0 μm 4000 2000 cm -1 1800 900 cm -1 4000 2000 cm -1 1800 900 cm -1 4000 2000 cm -1 1800 900 cm -1 ATR Crystal Material ZnS ZnSe ZnS ZnSe ZnS ZnSe ZnS ZnSe ZnS ZnSe ZnS ZnSe ATR Frame Material Spectrometer Housing Material Stainless steel Anodized aluminium Number of Sample Reflections 9 Dimensions (L x W x H) Protection Class 165 x 74 x 35 mm IP64 Battery Lithium polymer (LiPo) 1300 mah Power Requirement 5 Volt DC, 5 W 5 Volt DC, 5 W 5 Volt DC, 10 W Standalone Operation yes Interface USB, Ethernet USB, Ethernet, Bluetooth USB, Ethernet, CANopen Weight ~700 g ~710 g ~750 g IR Sphinx Transmission product portfolio and technical specification Spectrometer Transmission Lab Transmission Portable Transmission Industrial Spectral range 2.5 5.0 μm 5.5 11.0 μm 2.5 5.0 μm 5.5 11.0 μm 2.5 5.0 μm 5.5 11.0 μm 4000 2000 cm -1 1800 900 cm -1 4000 2000 cm -1 1800 900 cm -1 4000 2000 cm -1 1800 900 cm -1 Cuvette Aluminium Aluminium Stainless steel + fluid channels Spectrometer Housing Material Anodized aluminium Dimensions (L x W x H) 85 x 99 x 97 mm 165 x 74 x 97 mm 85 x 99 x 97 mm Protection Class IP44 IP64 IP44 Battery Lithium polymer (LiPo) 1300 mah Power Requirement 12 Volt DC, 5 W 5 Volt DC, 5 W 12 Volt DC, 10 W Standalone operation yes Thermal Stablisation yes Interface USB, Ethernet USB, Ethernet, Bluetooth USB, Ethernet, CANopen Weight ~430 g ~720 g ~460 g

Sphinx Suite-Software All Spectrolytic s products come with a proprietary software called Sphinx Suite. The software is modular and can be customised as required. The software also has the option to interface directly with commonly used data processing software such as Unscrambler. By default all spectrometers are delivered with the Basic software option. The Basic software module allows the customer to perform measurements, save data, export data etc. F A E D A: Menu bar with configuration options B: Measurement options and import/export configuration C: Start & Stop measurement button D: Graphic display C B E: Data selection tabs F: Measurement selection G G: Status bar with information about battery charge level, connection an folders Sphinx Suite-Software Modules The picture below depicts the available software modules that are available within Sphinx Suite. Basic Automation Chemometrics Prediction Stand alone Frequency Modulation Basic software Automation module Chemometric module Prediction module Stand alone module Measuring and capturing spectral data, saving data, exporting data to Excel etc. Definition of measurement routines, Continues execution of measurement routine, automatic data capture, automated reconnect after computer restart, trigger modus, control of extension interface ANN model builder (classification), PLS1 model builder (quantification), SIX model builder (similarity index), band pass filter model builder, Definition of control parameters, saving of models, analysis of historic data Integration in Automation module, automatic evaluation of measured IR spectra, visualisation of control values, saving of the analytical results, generation of customised reports OCOM interface (allows user to control spectralmeter via external interface), transfer of automation sequences onto spectrometer, autonomous measurement by spectrometer without computer Frequency Modulation module Optimisation of emitter modulation frequency between 5 20 Hz