ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING) VOL. 10, NO. 5 (2009) PAGES **-**

Similar documents
AMPLIFICATION OF GROUND STRAIN IN IRREGULAR SURFACE LAYERS DURING STRONG GROUND MOTION

Technical Note 16 Equivalent Static Method

Task 1 - Material Testing of Bionax Pipe and Joints

The Preliminary Study of the Impact of Liquefaction on Water Pipes

PILE FOUNDATION RESPONSE DUE TO SOIL LATERAL SPREADING DURING HYOGO-KEN NANBU EARTHQUAKE

A STUDY ON DAMAGE TO STEEL PIPE PILE FOUNDATION ON RECLAIMED LAND DURING HYOGO-KEN-NANBU EARTHQUAKE

RESPONSE OF STEEL BURIED PIPELINES TO THREE-DIMENSIONAL FAULT MOVEMENTS BY CONSIDERING MATERIAL AND GEOMETRICAL NON-LINEARITIES

Special edition paper

Department of Civil Engineering, Kyoto University, by Shunzo OKAMOTO, M. J. A., Sept.

Direct Tension and Split Basin Testing of 6-in. (150-mm)- Diameter Kubota Earthquake Resistant Ductile Iron Pipe

Section Forces Within Earth. 8 th Grade Earth & Space Science - Class Notes

MECE 3321 MECHANICS OF SOLIDS CHAPTER 3

STUDIES ON SEVARAL COUNTERMEASURES AGAINST LIQUEFACTION-INDUCED FLOW AND AN APPLIVATION OF A MEASURE TO EXISTING BRIDGES IN TOKYO

Evaluation of McWane Seismic Flex Coupling for Resistance to Earthquake-Induced Ground Deformation

STRUCTURAL STRAIN ESTIMATION OF SEGMENTED SHIELD TUNNEL FOR SEVERE EARTHQUAKES

Evaluation of Water Distribution Jointed Pipe Networks under Transient Ground Motions

Field Investigation and Dynamic Analysis of Damaged Structure on Pile Foundation during the 2011 off the Pacific Coast of Tohoku Earthquake

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

Section 19.1: Forces Within Earth Section 19.2: Seismic Waves and Earth s Interior Section 19.3: Measuring and Locating.

RELIQUEFACTION POTENTIAL OF CEMENT-TREATED SANDY SOILS

DETAILED INVESTIGATION OF PILES DAMAGED BY HYOGOKEN NAMBU EARTHQUAKE

SEISMIC DESIGN OF CONTINUOUS BURIED PIPELINE A.K.Arya 1 *, B. Shingan 2,, Ch. Vara Prasad 3

Simulation of Nonlinear Behavior of Wall-Frame Structure during Earthquakes

ANALYTICAL STUDY ON SOIL-PIPELINE INTERACTION DUE TO LARGE GROUND DEFORMATION

Seismic Response Analysis of Structure Supported by Piles Subjected to Very Large Earthquake Based on 3D-FEM

A STUDY ON PERMANENT DISPLACEMENT OF EXPRESSWAY EMBANKMENT DURING LARGE-SCALE EARTHQUAKES THROUGH DYNAMIC CENTRIFUGE MODEL TESTS

ME 243. Mechanics of Solids

American Earthquake Joint System for Resistance to Earthquake-Induced Ground Deformation

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

RESIDUAL DEFORMATION OF CAISSON, SHEET PILE AND GROUND BY SIMPLIFIED ANALYSIS

4.MECHANICAL PROPERTIES OF MATERIALS

EXPERIMENTAL AND NUMERICAL MODELING OF THE LATERAL RESPONSE OF A PILE BURIED IN LIQUEFIED SAND

Objectives: After completion of this module, you should be able to:

Chapter 4-b Axially Loaded Members

Experimental Study on Damage Morphology and Critical State of Three-Hinge Precast Arch Culvert through Shaking Table Tests

Mechanical Engineering Ph.D. Preliminary Qualifying Examination Solid Mechanics February 25, 2002

Centrifuge Shaking Table Tests and FEM Analyses of RC Pile Foundation and Underground Structure

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

1.103 CIVIL ENGINEERING MATERIALS LABORATORY (1-2-3) Dr. J.T. Germaine Spring 2004 LABORATORY ASSIGNMENT NUMBER 6

Unit Workbook 1 Level 4 ENG U8 Mechanical Principles 2018 UniCourse Ltd. All Rights Reserved. Sample

Study of Pile Interval of Landslide Restraint Piles by Centrifuge Test and FEM Analysis

Study on acceleration response spectra for seismic design based on observed records in Hokkaido, JAPAN

LIQUEFACTION HISTORY, , IN JAPAN

Author(s) Sawamura, Yasuo; Kishida, Kiyoshi;

Elasticity. A PowerPoint Presentation by Paul E. Tippens, Professor of Physics Southern Polytechnic State University Modified by M.

Tensile stress strain curves for different materials. Shows in figure below

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Verification of Numerical Modeling in Buried Pipelines under Large Fault Movements by Small-Scale Experiments

Module 6 LIQUEFACTION (Lectures 27 to 32)

There are three main types of structure - mass, framed and shells.

Effective stress analysis of pile foundations in liquefiable soil

Four-Point Bending and Direct Tension Testing of Twelve Inch TR-XTREME Pipe Joint

Protection of Pipelines and Buried Structures Using EPS Geofoam. Campus Dr., Salt Lake City, UT 84112;

Technical Note PP TN Engineering Considerations for Temperature Change

Brittle Deformation. Earth Structure (2 nd Edition), 2004 W.W. Norton & Co, New York Slide show by Ben van der Pluijm

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

Chapter Two: Mechanical Properties of materials

ME 2570 MECHANICS OF MATERIALS

1.8 Unconfined Compression Test

PERIYAR CENTENARY POLYTECHNIC COLLEGE PERIYAR NAGAR - VALLAM THANJAVUR. DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK

STRESS, STRAIN AND DEFORMATION OF SOLIDS

EXPERIMENTS ON SHEAR-FLEXURAL BEHAVIORS OF MODEL CAST IN PLACE CONCRETE PILES

Y. Shioi 1, Y. Hashizume 2 and H. Fukada 3

Samantha Ramirez, MSE. Stress. The intensity of the internal force acting on a specific plane (area) passing through a point. F 2

COEFFICIENT OF DYNAMIC HORIZONTAL SUBGRADE REACTION OF PILE FOUNDATIONS ON PROBLEMATIC GROUND IN HOKKAIDO Hirofumi Fukushima 1

EARTHQUAKE SIMULATION TESTS OF BRIDGE COLUMN MODELS DAMAGED DURING 1995 KOBE EARTHQUAKE

Evaluation of dynamic behavior of culverts and embankments through centrifuge model tests and a numerical analysis

TRI-AXIAL SHAKE TABLE TEST ON THE THINNED WALL PIPING MODEL AND DAMAGE DETECTION BEFORE FAILURE

Earthquakes. Building Earth s Surface, Part 2. Science 330 Summer What is an earthquake?

ENG1001 Engineering Design 1

Nonlinear Seismic Analysis of Buried Pipelines During Liquefaction

Cyclic Triaxial Behavior of an Unsaturated Silty Soil Subjected to Suction Changes

Earthquakes. Forces Within Eartth. Faults form when the forces acting on rock exceed the rock s strength.

INTRODUCTION (Cont..)

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

Science Starter. Describe in your own words what an Earthquake is and what causes it. Answer The MSL

Earthquakes Chapter 19

Comparison of Mitigation Alternatives for Water Distribution Pipelines Installed in Liquefiable Soils. Donald Ballantyne 1 William Heubach 2

Peak Strain and Displacement Sensors for Structural Health Monitoring

Mechanics of Earthquakes and Faulting

Exercise 2: Bending Beam Load Cell

SAFETY EVALUATION OF SEISMICALLY ISOLATED HOUSES WITH DISPLACEMENT RESTRAINT DEVICES UNDER SEVERE EARTHQUAKE MOTIONS

Soil Dynamics and Earthquake Engineering

DAMAGE ANALYSIS OF WATER SUPPLY PIPES DUE TO THE 2004 NIIGATA-KEN CHUETSU, JAPAN EARTHQUAKE ABSTRACT

AXIAL COLLAPSE OF REINFORCED CONCRETE COLUMNS

Module-4. Mechanical Properties of Metals

Performance Evaluation of Bionax SR PVCO Pipeline with Extended Bell Joints under Earthquake-Induced Ground Deformation

Rock slope failure along non persistent joints insights from fracture mechanics approach

Lecture #2: Split Hopkinson Bar Systems

Interaction of Soil Static and Dynamic Stiffness and Buried Pipeline Under Harmonic Vibration

Mechanics of Solids. Mechanics Of Solids. Suraj kr. Ray Department of Civil Engineering

POST-CYCLIC RECOMPRESSION CHARACTERISTICS OF A CLAY SUBJECTED TO UNDRAINED UNI-DIRECTIONAL AND MULTI-DIRECTIONAL CYCLIC SHEARS

Sean Carey Tafe No Lab Report: Hounsfield Tension Test

Chapter 12. Static Equilibrium and Elasticity

Members Subjected to Torsional Loads

Cone-shaped socket connections for cylindrical members

Solid Mechanics Homework Answers

SHEAR CAPACITY OF REINFORCED CONCRETE COLUMNS RETROFITTED WITH VERY FLEXIBLE FIBER REINFORCED POLYMER WITH VERY LOW YOUNG S MODULUS

Geology 229 Engineering Geology. Lecture 5. Engineering Properties of Rocks (West, Ch. 6)

Effect of cyclic loading on shear modulus of peat

Transcription:

ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING) VOL. 10, NO. 5 (2009) PAGES **-** AN EXPERIMENTAL STUDY ON THE ANTI-SEISMIC PERFORMANCE OF A U-PVC WATER SUPPLY PIPELINE WITH ENLARGED EXPANSION JOINTS M. Nakano *, S. Katagiri and S. Takada Department of Civil Engineering, Osaka-Sangyo University, Osaka, Japan Department of Civil and Environmental System Eng., Setsunan University, Osaka, Japan Department of Civil Engineering, Teheran University, Iran ABSTRACT This paper reports on a full-scale experiment and numerical analysis performed to verify the earthquake resistance of a rubber ring (RR)-type U-PVC pipeline with enlarged expansion joints for water distribution. In the experiment, one end of a buried model pipeline measuring 20 m in length was pulled out and/or pushed in using a hydraulic jack to simulate the relative ground movement that occurs during the sliding of a soil mass parallel to the pipeline's longitudinal axis. The results indicated a high level of expansion performance and slip-out prevention capability in the expansion joints. Furthermore, a high-speed loading experiment for the expansion joints was carried out to verify their performance against seismic relative ground movement. The outcome clarified that the enlarged expansion joints with slip-out prevention offer a high level of anti-seismic performance for U-PVC water supply pipelines. Keywords: Anti-seismic performance; expansion joint; U-PVC pipeline 1. INTRODUCTION In the past, serious pipeline damage has been caused by seismic relative ground movement (fissures) as well as permanent ground displacement (PGD) induced by liquefaction. As a result, after the 1995 Hyogo-ken Nambu Earthquake, PGD in liquefiable ground was taken into consideration in the revised anti-seismic design guidelines for water supply pipelines in Japan [1]. An earthquake s effect on pipelines is treated as permanent ground strain (PGS), which is represented by the average value of tensile or compressive strain over a 100-m length of ground surface along a pipeline. However, it has been observed that both the locations and widths of fissures in the ground surface show a close correlation to pipeline damage. It is also clear that the ground surface cannot remain continuous when the relevant tensile strain exceeds its elastic level. Accordingly, * Email address of the corresponding author: nakano@ce.osaka-sandai.ac.jp (M. Nakano)

** M. Nakano, S. Katagiri and S. Takada the authors have studied the relationship between PGS and fissure width by analyzing PGD data observed in Noshiro City after the 1983 Nihonkai-Chubu Earthquake. A new expansion joint for RR U-PVC water supply pipelines was designed to withstand a 1.5% permanent ground strain as well as a 20 cm fissure. As shown in Figure 1, it is composed of a slip-out prevention device and an enlarged pipe end with an expansion capability of ±75 mm, into which a spigot pipe end fits. When the relative ground movement is assumed to be that of the ground-block model illustrated in Figure 2, a 20-cm fissure must be absorbed by the expansion of three joints. The slip-out prevention strength F of the joint that lies at the fissure must therefore be higher than the total soil friction force acting on one pipe in order to propagate the axial force to the neighboring joints on the right and left. Figure 1. Joint structure of new RR U-PVC pipe Figure 2. Ground block model 2. PIPELINE DAMAGE RELATED TO FISSURES DURING PAST EARTHQUAKES According to investigations of buried pipelines damaged during past earthquakes in Japan, the points at which damage occurs are closely related to both the locations and widths of fissures in the ground surface. The Japan Ductile Iron Pipe Association conducted an investigation on joint movement in ductile cast-iron pipelines in the Kobe area after the 1995 Hyogo-ken Nambu Earthquake[2]. Both the amount and the location of joint movement measured using a TV camera inserted into the pipelines were shown to be closely in line with the widths and locations of fissures that had appeared in the ground surface. Photo 1 shows an example of damaged PVC water distribution pipelines in Kitahiyama Town during the 1993 Hokkaido-Nansei-Oki Earthquake [3]. PVC pipelines with rubberring-type joints were damaged at 31 locations, with most of the damage caused by the slipout of joints as shown in Photo 1. The waterworks division of Kitahiyama Town reported that many fissures were found in the ground surface around the damaged pipeline locations, as shown in Photo 2. The same situation was also found in Hokudan Town on Awaji Island where the epicenter of the 1995 Hyogo-ken Nanbu Earthquake was situated. In this area, PGD due to the collapse of steep slopes occurred along small roads under which water distribution pipelines ran. In most cases, damage involving the slip-out of joints was related

AN EXPERIMENTAL STUDY ON THE ANTI-SEISMIC PERFORMANCE... ** to fissures and uneven ground subsidence in the road surface [4]. Photo 1. RR joint slip-out Photo 2 A fissure in the ground surface 3. EXPERIMENT TO CONFIRM THE PERFORMANCE OF U-PVC PIPELINE WITH EXPANSION JOINTS Figure 3 shows an outline of the experiment. A model pipeline measuring 20 m in length with three new RR joints was buried in a test field. The nominal diameter of the pipe was 100 mm, and the design strength of the slip-out preventer was more than 35 kn. One end of the pipeline was connected to a hydraulic jack. By pulling out and/or pushing in the pipe end, relative ground movement considered to correspond to the pipeline damage found in Kitahiyama and Hokudan towns (such as fissures and/or compression the opposite of fissures) was simulated along the stretch of pipeline. The longitudinal displacement of the pipe was measured using wire-type displacement transducers connected to the flared pipe end and the spigot pipe end at each joint. Longitudinal force was applied to the pipeline in stages with the estimated maximum force divided into about 30 steps, and the resulting behavior was measured at each stage. The in-situ dry density of the model ground was about 93% to 96% of the maximum dry density. The analytical model using beam theory is shown in Figure 4. The non-linear characteristics of the soil spring and joint expansion were taken into consideration. Figure 3. Experimental method

** M. Nakano, S. Katagiri and S. Takada Loading force (kn) 7 6 5 4 3 2 1 kss: Ground spring for pipe kst: Ground spring for joint kn: Joint spring (expansion) Figure 4. Analytical model Experiment Simulation 0 200 400 Displacement at loading point (mm) Figure 5. Force-displacement relationship (pulling out) Figure 5 shows the force-displacement relationship at the loading point. The maximum force was 64.7 kn, and the pull-out displacement at that time was 370 mm. Joint 1 subsequently slipped out, and the experiment was stopped. The rapid reduction in force was due to the resetting of the jack system. Small jumps in the force appeared three times when each joint started to move due to higher ground resistance. The analytical results of the force-displacement relationship agreed with those of the experiment fairly accurately. The relationship between the loading force and expansion of each joint is shown in Figure 6. The slip-out displacement of each joint was held to within 75 mm, which proved the efficacy of the slip-out prevention measures. Although the design strength of the prevention device was more than 35kN, the maximum resistant force was estimated at more than 44kN. In the experiment, the prevention of joint slippage was achieved after the joint moved about 60mm, while the same prevention effect appeared at 75mm in the analysis.

AN EXPERIMENTAL STUDY ON THE ANTI-SEISMIC PERFORMANCE... ** Loading force (kn) 8 6 4 2 Expe.(Joint 1) Expe.(Joint 2) Expe.(Joint 3) Simu.(Joint 1) Simu.(Joint 2) Simu.(Joint 3) 0 20 40 60 80 100 120 Joint movement (mm) Figure 6. Joint expansion (pulling out) Figure 7 shows the force-displacement relationship at the loading point. The maximum force was 65.7kN, and the push-in displacement at that time was 400 mm. All pipes subsequently started to move and the force did not increase, so the experiment was stopped. The loading jack system was reset three times. The analytical results of the forcedisplacement relationship agreed with those of the experiment fairly accurately. The relationship between the loading force and the expansion of each joint is shown in Figure 8. The retraction displacement of each joint was held to within 75 mm, which proved the efficacy of the slip-out prevention measures. The joints were observed in detail after excavation, but no slippage of the prevention mechanism was found. In general, the analytical data showed good agreement with the experimental data. Loading force (kn) 7 6 5 4 3 2 1 Experiment Simulation 0 100 200 300 400 500 Displacement at loading point (mm) Figure 7. Force-displacement relationship (pushing in)

** M. Nakano, S. Katagiri and S. Takada Loading force (kn) 8 6 4 2 Expe.(Joint 2) Expe.(Joint 3) Simu.(Joint 2) Simu.(Joint 3) 0 20 40 60 80 100 120 Joint movement (mm) Figure 8. Joint expansion behavior (pushing in) 4. HIGH-SPEED LOADING EXPERIMENT FOR THE EXPANSION JOINT WITH SLIP-OUT PREVENTION The experiment described above was a static-loading-type test. Therefore, the authors subsequently carried out a high-speed loading experiment for the expansion joint with slipout prevention to verify its performance against seismic relative ground movement. Figure 9 shows the experimental method. One end of a model pipe segment with an expansion joint was fixed to the reaction wall, and the other end was pulled out and pushed in using a hydraulic actuator at a velocity of 1,000mm/s. Reaction wall Load cell Expansion joint :Strain gages in axial direction Actuator Diplacement meter Figure 9. High-speed loading experiment As shown in Figures 10 and 12, the strength of the slip-out prevention measured in the experiment exceeded its design value both for the pulling and pushing directions even at a velocity of 1,000 mm/s. Until reaching a displacement of ±75 mm, the resistant force of the joint was very small, after which a high level of prevention was seen. The slip-out prevention device finally slipped after the applied load exceeded the design value, but the

AN EXPERIMENTAL STUDY ON THE ANTI-SEISMIC PERFORMANCE... ** axial pipe strain observed was under the allowable limit of the U-PVC pipe (10,000 10-6 ) as shown in Figures 11 and 13. It can therefore be said that a prevention device made of ductile iron will not affect the U-PVC pipe body even under conditions of very-high-speed relative ground movement during an earthquake. Reaction force (kn) Reaction force(kn) 35.0 3 25.0 2 15.0 1 5.0 Designed prevention strength 5 10 Pulling-out displ.(mm) Figure 10. Force displacement (pulling out) -1-2 -3-4 -5 10000 8000 6000 4000 2000 Designed prevention strength -15-10 -5 Pushing-in displ.(mm) Axial pipe strain ( 10-6 ) Axial pipe strain( 10-6 ) 0 Flared end-1 Flared end-2 Spigot end-1 Spigot end-2 5 10 Pulling-out displ.(mm) Figure 11. Axial pipe strain (pulling out) 0-2000 -4000-6000 -8000-10000 -12000-15 -10-5 Pushing-in displ.(mm) Flared end-1 Flared end-2 Spigot end-1 Spigot end-2 Figure 12. Force displacement (pulling out) Figure 13. Axial pipe strain (pulling out)

** M. Nakano, S. Katagiri and S. Takada 5. RELATIVE-GROUND-MOVEMENT ABSORPTION CAPABILITY OF A PIPELINE When the relative ground movement is assumed to be that of the ground block model illustrated in Figure 14, the maximum relative displacement (fissure width) δ p, which is required to break the pipeline, can be given as follows: δ p 2 E A ε p = π D τ where E: Young s modulus of the pipe, A: cross-sectional area of the pipe, ε p : critical strain of the pipe (joint strength), D: outer diameter of the pipe, and τ: soil friction force per unit area of pipe surface. δ p =ε p L ε L p =(E A ε p )/(π D τ ) ii l i f h i Figure 14. Ground block model A pipeline with a large δ p value offers a higher level of resistance against fissures. On the other hand, length L p, which is the minimum length of the ground block required to break the pipeline, is also considered to play an important role in minimizing pipeline damage. When a pipeline fails in one portion due to a fissure, other fissures that form within distance L p from the first fissure cannot cause further damage because the length of the ground block becomes less than L p, and the block cannot provide sufficient force to break the pipeline. Accordingly, the longer L p becomes, the smaller the possibility of pipeline failure is. Nishio introduced this idea into pipeline damage estimation [5]. The anti-seismic type of ductile cast-iron pipeline, which did not fail in recent earthquakes, is considered to offer excellent earthquake-proof performance because the antiseismic type of joint provides very high strength, thus preventing it from slipping out under the influence of large ground deformation after reaching its expansion limit. However, such high joint strength has not been taken into account in the anti-seismic design of buried pipelines that have to deal with ground strain. Table 1 shows the most commonly utilized pipes and joints for water supply pipelines and the values ofδ p and L p obtained from them. The U-PVC pipeline with the expansion joint reported in this paper is also considered to offer a reasonably high level of performance against relative ground movement. p (1)

AN EXPERIMENTAL STUDY ON THE ANTI-SEISMIC PERFORMANCE... ** Table 1. Relative-ground-displacement absorption capability of typical pipeline types No. Applicatio n Pipe material Joint type Diameter (mm) δ p (cm) L p (m) 1 Ductile iron Rubber ring type (K type) φ300 4.5 5.0 2 Water Ductile iron Anti-seismic type (S type) φ300 20 10 distribution 3 PVC Expansion joint with slip-out prevention φ100 2 1 6. CONCLUSIONS Through experimentation and numerical analysis, the behavior of an expansion joint for RR U-PVC pipeline subjected to longitudinal ground movement (such as fissures and compression) was ascertained. It was clarified that the expansion and slip-out prevention capabilities of the new joint worked well under buried conditions. Numerical analysis using beam theory seemed to simulate the experiment fairly well. The new RR U-PVC pipe with slip-out prevention is considered to provide sufficient earthquake resistance for water distribution pipelines even under the severe conditions of Level-2 seismic ground motion and permanent ground deformation due to liquefaction. REFERENCES 1. Japan Water Works Association: Seismic Design and Construction Guidelines for Water Supply Facilities, 1997. 2. Japan Ductile Iron Pipe Association: Damage to buried water distribution pipelines and ground deformation from the 1995 Hyogoken-nanbu (Kobe) earthquake, Proceedings of IWSA International Workshop, 1998, pp. 43-48 3. Waterworks Division of Kitahiyama Town: A report on post-earthquake investigation of water distribution pipelines after the 1993 Hokkaido-Nansei-Oki Earthquake, 1993. 4. Waterworks Division of Hokudan Town: A report on post-earthquake investigation of water distribution pipelines in Hokudan Town after the 1995 Hyogoken-Nanbu Earthquake, 1995. 5. Nishio N. Anti-seismic design of buried structures, Proceedings of the Workshop on the Earthquake-proof Performance of Lifelines, The Japanese Geo-technical Society, 1995, pp. 41-75.