Suresh Gyan Vihar University, Jaipur , Rajasthan, India.

Similar documents
ChromegaChiral TM Columns. The right choice for chiral purification

ChromegaChiral TM CSP Media and Columns

ChromegaChiral TM CSP Media and Columns

CHAPTER 1 Role of Bioanalytical Methods in Drug Discovery and Development

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Chiral Separation and Discrimination in High- Performance Liquid Chromatographic Systems

Principles of Gas- Chromatography (GC)

Journal of Chromatography A

Chromatographic Analysis

CHIRAL SEPARATION USING THIN LAYER CHROMATOGRAPHY

CHIRAL SEPARATION AND DISCRIMINATION OF ENANTIOMERS

LIQUID CHROMATOGRAPHIC ENANTIOSEPARATION OF ACTIVE PHARMACEUTICAL INGREDIENTS AND STERICALLY HINDERED AMINO ACIDS. Ph.D. Thesis. Roland Sándor Török

ASIAN JOURNAL OF CHEMISTRY

Chromatographic Methods of Analysis Section 2: Planar Chromatography. Prof. Tarek A. Fayed

Method Development for Chiral LC/MS/MS Analysis of Acidic Stereoisomeric Pharmaceutical Compounds with Polysaccharide-based Stationary Phases

APPLICATIONS TN HPLC Conditions. Lux Cellulose-1 Cellulose tris(3,5-dimethylphenylcarbamate)

INSTITUTE OF MEDICAL BIOCHEMISTRY FIRST FACULTY OF MEDICINE, CHARLES UNIVERSITY IN PRAGUE. Chromatography. in biochemistry

Enantiomeric separation of 1, 2, 3, 4-tetrahydro-1-naphthoic acid using chiral stationary Phase

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

Introduction to Chromatography

A validated chiral HPLC method for the enantiomeric purity of alogliptin benzoate

Enantiomeric and Diastereomeric Separations of Pyrethroids Using UPC 2

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Chromatography. writing in color

Chiral Flash Columns

PAPER AND THIN LAYER CHROMATOGRAPHY (TLC)

Chapter 26. An Introduction to Chromatographic Separations. Chromatography

1Determination of optical purity of N-acetyl-1-naphthylethylamine by chiral chromatography and NMR spectroscopy

CHAPTER-4. determination of chiral purity of (S)-2azido-3-methylbutanoic acid: a key raw. material of Valganciclovir hydrochloride

Chapter 6. Isomers and Stereochemistry

Derivatization of Chiral Compounds with Chiral Reagents and Separation their Isomers by HPLC System

Application Note. Authors. Abstract. Pharmaceuticals

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

ISSN : A validated chiral LC method for enantiomeric separation of levocetrizine using protein based chiral stationary phase

Contents lists available at ScienceDirect. Journal of Pharmaceutical Analysis.

Optical Isomer Separation Columns and Packing Materials

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Chapter 6. Isomers and Stereochemistry

Problem Set 7: Stereochemistry-ANSWER KEY

Available online at Journal of Chromatography A, 1178 (2008)

Analytical Chemistry

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Fall Organic Chemistry Experiment #6 Fractional Crystallization (Resolution of Enantiomers)

HPLC Background Chem 250 F 2008 Page 1 of 24

CHROMTECH - CHIRAL HPLC COLUMNS

Chiral Recognition Mechanisms of four β-blockers by HPLC with Amylose Chiral Stationary Phase

Chiral separations efficient, fast and productive

TLC Separation of Nitrophenones on Polar Adsorbents

High Pressure/Performance Liquid Chromatography (HPLC)

Separation Methods in Drug Synthesis and Purification

Chapter 5 Stereochemistry

Chromatography. Mrs. D. MEENA MPharm PA & QA KTPC

ISSN Original Article Enantiomeric Liquid Chromatographic Separation of Methyl lactate on Amylose based Sorbent

CE and CEC. 1 Introduction. Electrophoresis 2004, 25, Xiaoming Chen Feng Qin Yueqi Liu Liang Kong Hanfa Zou

Experiment 1: Thin Layer Chromatography

Introduction to Pharmaceutical Chemical Analysis

ChiroSolve Enantiomer preparation for discovery, development and manufacturing

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

Introduction. Chapter 1. Learning Objectives

Chapter 27: Gas Chromatography

Calculate a rate given a species concentration change.

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

EVALUATION OF EXPERIMENTAL PARAMETER INFLUENCE ON HPLC SEPARATION OF SOME AMINES AND

Hypersil BDS Columns TG 01-05

Measuring enzyme (enantio)selectivity

Packings for HPLC. Packings for HPLC

Handling Products. Sumitomo Chemical Co., Ltd. SUMICHIRAL ~192

CHROMATOGRAPHY: LIQUID

Chiral Separation Techniques: A Practical Approach

Open Column Chromatography, GC, TLC, and HPLC

Chapter 5 Stereochemistry. Stereoisomers

Chapter 5 Stereochemistry

LC-MS compatible Separation of the Fungicide Spiroxamine

Capacity vs Throughput on Modified Macrocylics in Reversed Phase, Polar Ionic Mode and Normal Phase

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

M. Sajewicz, M. Gontarska, D. Kronenbach, Ł. Wojtal, G. Grygierczyk, and T. Kowalska


Development and Validation of Chiral LC Method for the Enantiomeric Separation of Duloxetine on Amylose Based Stationary Phase

High Performance Liquid Chromatography

Journal of Chemical and Pharmaceutical Research

Asymmetric Transfer Hydrogenation: A Suitable Tool for the Synthesis of the Precursors of Pharmaceutical Substances

AMINO ACIDS AND DERIVATIVES: CHIRAL SEPARATIONS

Introduction to Chromatographic Separations

FACULTY OF PHARMACY. M. Pharmacy I Semester (Suppl.) Examination, November 2015 (Common To All) Subject: Pharmaceutical Analytical Techniques

Separation of Toxic Metal Cations on Stannous Silicate layers in Micellar TLC

Section A. 1 at a given temperature. The rate was found to be first order with respect to the ester and first order with respect to hydroxide ions.

Application of Densitometry for Determination of Beta-Adrenergic-Blocking Agents in Pharmaceutical Preparations

Organic Chemistry. 2 nd Stage Pharmacy/ Undergraduate

STEREOGENIC CENTER (Chiral Center,Asymmetric Center) Atom (usually carbon) to which 4 different groups are attached: W Z C X Y

NOTE. Introduction. Keywords Chiral analysis. HPLC. Ovomucoid stationary phase. Pharmaceuticals. Paroxetine enantiomers

Liquid Chromatography

COPYRIGHTED MATERIAL INTRODUCTION

Chiral Columns for enantiomer separation by HPLC

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

Chapter 23 Introduction to Analytical Separations

CHIRAL STATIONARY PHASES

Practicing Chiral Chromatography in Your Mobile Phase Comfort Zone

School of Chemistry UNIVERSITY OF KWAZULU-NATAL, WESTVILLE CAMPUS JUNE 2009 EXAMINATION CHEM340: INSTRUMENTAL ANALYSIS.

SIMULTANEOUS DETERMINATION OF TRIAMTERENE AND HYDROCHLOROTHIAZIDE IN TABLETS USING DERIVATIVE SPECTROPHOTOMETRY

Chromatography & instrumentation in Organic Chemistry

Transcription:

Suresh Gyan Vihar University International Journal of Environment, Science and Technology Volume 3, Issue 2, August 2017, pp. 35-41 ISSN: 2394-9570 Enantiomeric separation of betaxolol using liquid chromatographic techniques: A review Hariom Nagar Suresh Gyan Vihar University, Jaipur-302017, Rajasthan, India. Email: hariomnagariitr@gmail.com, hariom.nagar@mygyanvihar ABSTRACT: Amino alcohols like β-blockers are very important drugs for the treatment of heart related diseases. This is due to presence of active functional groups (-OH and NH 2 ) in their unique and simple structure. Betaxolol a selective β 1 -receptor antagonist is one of the most prescribed drug for treatment of particularly hypertension, and it is also a very strong antiglaucoma agent. (S)-( )-enantiomer of β-blockers shows about 50-500 fold higher pharmacological activities, due to the specific and proper orientation of groups to react with β 1 - receptor. There has been no attempt to review on the enantiomeric separation of betaxolol using chromatographic techniques. This paper deals with the application of: high-performance liquid chromatography by direct method, using chiral stationary phases and, by indirect method using chiral derivatizing reagent and; thin layer chromatography by direct method using chiral selector as chiral impregnating reagent, chiral inducing reagent and chiral mobile phase additives. Keywords: β-blockers, chiral selector, enantiomeric separation, thin layer chromatography, high-performance liquid chromatography, chiral derivatizing reagent INTRODUCTION β-blockers (also known as β-adrenolytic drugs) consist of a group of synthetic chiral hydroxyl amine-containing compounds with pka 9.2. They stop adrenaline from binding to nerve receptors and block its effects. Betaxolol a potent β 1 - receptor blocker used in the treatment of hypertension and glaucoma. It shows greater affinity for β 1 -receptor than metoprolol. The (S)-( )-enantiomer of betaxolol drug (Figure) is pharmacologically effective, showing about 50 500-fold higher activities (Lee and William 1990). In most cases betaxolol is administered as racemic mixtures. Since the enantiomers have different activity in chiral environment of our body therefore these enantiomers are considered different compounds. Many biologists and clinical pharmacologists tend to deal with enantiomeric mixtures of isomers. A 35

physician, presenting such a drug under a brand name is unaware of different activity of enantiomers and may make mistakes (Ariens 1984). Therefore, many regulatory agencies ask the pharmacologists to present full pharmacokinetics and pharmacological information of both the enantiomers. Because in certain cases, the less reactive or unwanted enantiomer can have side effects or even toxic effects. Therefore, efficient methods of enantioresolution are always required to control the enantiomeric purity or to resolve racemic mixtures and to determine optical purity of the drugs. Enantiomeric separation has immense importance in various fields from academic and industrial point of view. For enantiomeric separation two basic strategies direct approach and indirect approach have evolved in recent years. The direct approach has no require derivatization and separation can be achieved by using chiral selector: as chiral impregnating reagent, chiral mobile phase additives and chiral inducing reagent in thin layer chromatography and; as chiral stationary phase in high-performance liquid chromatography, to produce chiral environment in situ formation of transient diastereomers between enantiomers present in analyte and the enantiomer of pure chiral selector. In indirect method, there is first conversion of the enantiomers of analyte species in to daistereomers by reacting them with chiral derivatizing reagents and then separation can be done by chromatography in achiral environment. In literature review there have been reported some basic approaches and principles of planar and column chromatography for enantiomeric separation of betaxolol. Nevertheless, there has been no attempt to review on the enantiomeric separation of betaxolol by chromatography using the direct and indirect approaches. The present paper focused on the use of liquid chromatography for the enantiomeric separation of betaxolol. DIRECT APPROACH Ennatiomeric separation using direct approach is depends on the chiral environment which is either produced by incorporating a suitable chiral selector at an appropriate stage or created in the form of chiral stationary phase (CSP). This chiral invironment can be created in thin-layer chromatography (TLC) and highperformance liquid chromatography (HPLC) by (a) preparing the TLC plate or the column with the chiral selector, (b) impregnating the chiral selector on stationary phase of TLC, or (c) adding the chiral selector to the mobile phase. The material mentioned at (a) is chiral owing to its own structure (e.g. cellulose) while the material mentioned at (b) is prepared by bonding the chiral selector of interest to reactive groups of inert support. In situation (c) chiral environment is created by mixing the chiral selector and with mobile phase and flow of this mixture prior to separation. In all the cases, transient daistereomers are formed on the surface by the interaction of chiral selector with enantiomers of analyte of interest. The separation of these enantiomers is based on the concept is that, the enantiomer forming most stable 36

daistereomers will be most retained with stationary phase it means elute later and the enantiomer forming less stable daistereomer elute earlier. Martens and Bhushan (1990) direct methods for separation of enentiomers are important in various fields like synthetic and mechanistic study, pharmaceutuical and biomedical analysis. Enantiomeric separation by TLC Using Impregnation The technique in which a suitable chiral selector is incorporating with the adsorbent without covalently affecting its inert character, owing to application of samples on the plate for their separation is termed as impregnated TLC. There are various methods used for impregnation of TLC: spraying the solution of the impregnating reagent on the plate; immersing plain plate or ascending or descending the plate in a normal manner of development into an appropriate solution of the impregnating reagent; exposing the thin layer to the vapors of the impregnating reagent; and mixing the chiral selector with the inert support. In case of immersion there may be peeling of the thin layer, and in spraying method less uniform dispersion of the chiral selector on inert support than in the mixing of chiral selector with inert support or immersion (Bhushan and Martens, 1997). The overall results of resolution are depends on the kind of the functional groups and chemical nature of the impregnating reagent the compounds being separated, along with the influence of the impregnating reagent on the partition/or adsorption. The methods used for impregnation also play important role in the resolution of the enantiomers. This method provides an inexpensive and wide choice of chromatographic conditions for enantiomeric separation of variety of compounds. Enantiomeric separation of betaxolol has been carried out using the L-lysine/L-arginine (Bhushan and Thiong O, 1998), as chiral impregnating reagent and chromatographic data in terms of resolution and limit of detection (LOD) are given in Table. Using chiral inducing reagent (CIR) CIR: The chiral selector when mixed with the racemic mixture of the analyte then itself induced the chiral environment in medium prior to formation of transient daistereomers of analyte, so it is called the chiral inducing reagent. The advantages of this method over the impregnation is that the required quantity of the chiral selector is very less than the quantity of the chiral selctor required in impregnation methods. Since, in this method no requirement to produce chiral environment on the inert support of TLC for separation of enantiomers. Therefore, the TLC is called as achiral TLC and the separation is known as achiral phase chromatographic separation. Literature reported the use of (S)- Glutamic acid as CIR and chromatographic run was performed, results obtained were good in terms of R S (Bhushan et al. 2015). Enantiomeric separation by HPLC 37

It is most widely used method for the enantiomeric separation. Several chiral columns have been used in recent years for enantiomeric separation. These chiral column are commercially available in market. This method gives better result than the TLC method in regard of accuracy, precision and detection limit of the analyte. The detectors generally used in this technique is photodiode array detector (PDA) 2600, make the detection of analyte molecules up to pico meter level. Several columns containing chiral stationary phases, based on: cellulose, amylose, pirkle, ovomucoid, zirconia monolithic cyclodextrin and glycoprotein have been used for enantioseparation. Of the above stationary phase based columns, certain have been used for enantioseparation of betaxolol; Cellulose tris(3,5-dichlorophenyl-carbamate) (Ates et al. 2013), Cellulose tris(3,5-dimethylphenylcarbamate), (Peng et al, 2010), Amylose tris(3,5-dimethoxyphenyl carbamate), (Cass et al. 1999), and comparative data in terms of resolution time, limit of detection and resolution values, are given in Table. INDIRECT APPROACH Chromatographic conditions of indirect method can be optimized more easily than the direct method, therefore, separation of daistereomeric pair via indirect method is sometimes simpler and often better resolution obtained. High sensitive detector response in this technique is providing better determination of biological samples in blood and urine. The CDR used for derivatization of samples are generally chosen with good limit of detection. For example the Marfey s based CDRs shows high sensitive detector response to samples because of high molar UV-Vis absorptivity (ɛ) and fluorescence quantum yield. The reaction of CDR react with enantiomers of (±)- or the (R,S)-mixture is of different rates, therefore derivatization conditions must be optimized. In the structure of analyte sample suitable reactive group should be in close proximity to the stereogenic center, which is prone a quantitative transformation with the CDR and without forming the side products. Racemization must not be there of the sample and of the CDR in the reaction, which transforms the enantiomeric mixture into daistereomers. Enantiomers of betaxolol has been separated by converting them into daistereomers. Several CDRs have been used for the formation of daistereomers of betaxolol prior to their separation by HPLC. In Table separation data are given in terms of resolution of daistereomers of betaxolol formed with following CDRs: ( )- (α-methoxy-(α- (trifluoromethyl)phenylacetyl chloride (Kim et al. 2001); 1,3-diacetoxy-1-(4-nitrophenyl)-2-propyl isothiocyanate (Péter and Fülöp, 2001); 2,3,4,6-tetra-O-acetyl-b-Dgalactopyranosyl isothiocyanate (Ko et al. 2006); 2,3,4,6-tetra-O-acetyl-b-Dglucopyranosyl isothiocyanate (Ko et al. 2006). Marfey s reagent based CDRs; (R)- 2-(5-fluoro-2,4-dinitrophenylamino)-3- (methylthio)propanoic acid, (S)-N-(1- cyclohexylethyl)-5-fluoro-2,4- dinitrobenzenamine, (R)-5-fluoro-2,4- dinitro-n-(1-phenylethyl)benzenamine, have 38

been used by Bhushan and Nagar (2014) for synthesis of daistereomers of betaxolol and the structures of these daistereomers also optimized by using 09 Rev A. 02 and hybrid density functional B3LYP with 6-31G basis set. CONCLUSIONS The liquid chromatography using direct and indirect methods are very useful for quantitative and qualitative analysis of important pharmaceuticals. Direct method is more suitable for separation of enantiomers in their pure form without any derivatization and is less time consuming. Direct TLC method (i) is less expensive in comparison to HPLC, GC and capillary electrophoresis that require highly expensive experimental set-up and running costs, (ii) is successful for rapid and sensitive resolution, detection and isolation of enantiomers in a range lower than the limits prescribed (1%) for pharmaceuticals in industry. Direct HPLC is widely used method for separation of enantiomers because (i) most of the CSPs are commercially available in market, (ii) detection and isolation limit is up to pico meter level, (iii) no requirement of derivatization hence less time consuming. But the chiral column is of high cost in direct method, while in indirect method no requirement of chiral column so indirect HPLC is less expensive and therefore more useful for detection of enantiomers. ACKNOWLEDGEMENT The author (H Nagar) is grateful to SGVU, Jaipur for providing the technical facilities and peaceful environment for doing this job. REFERENCES Lee, E.J. and William, K.M. (1990). Chirality: Clinical pharmacokinetic and pharmacodynamic considerations. Clin. Pharmacokinet. 18: 339 345. Ariëns, E.J. (1984). Stereochemistry, a basis for sophisticated nonsense in pharmacokinetics and clinical pharmacology. Eur. J. Clin. Pharmacol. 26: 663 668. Bhushan, R. and Thiong O, G.T. (1998). Direct enantioseparation of some β- adrenergic blocking agents using impregnated thin-layer chromatography. J. Chromatogr. B 708: 330-334. Bhushan, R. and Martens, J. (1997). Direct resolution of enantiomers of impregnated TLC. Biomed. Chromatogr. 11: 280-285. Bhushan, R., Nagar, H. and Martens, J. (2015). Resolution of enantiomers with both achiral phases in chromatography: conceptual challenge. RSC Adv. 5: 28316-28323. Ates, H., Younes, A.A., Mangelings, D., and Heyden, Y.V. (2013). Enantioselectivity of polysaccharidebased chiral selectors in polar organic solvents chromatography: Implementation of chlorinated selectors in a separation strategy. J. Chromatogr. Biomed. 74: 1 13. 39

Peng, L., Jayapalan, S., Chankvetadze, B., and Farkas, T. (2010). Reversedphase chiral HPLC and LC-MS analysis with tris(chloromethylphenylcarbamate) derivatives of cellulose and amylose as chiral stationary phases. J. Chromatogr. A 1217: 6942 6955. Cass, Q.B., Tiritan, M.E., Calafatti, S.A., Matlin, S.A. (1999). Enantioseparation on amylose tris (3, 5-dimethoxyphenyl carbamate): application to commercial pharmaceutical chiral drugs. J. Liq. Chromatogr. Rel. Technol. 22 3091 3099. Kim, K.H., Lee, J.H., Ko, M.Y., Hong, S.P. and Youm, J.R. (2001). Chiral separation of β-blockers after derivatization with ( )-a-methoxy-a- (trifluoromethyl)phenylacetyl chloride by gas chromatography. Arch. Pharm. Res. 24: 402 406. Péter, M. and Fülöp, F. (2002). Comparison of isothiocyanate chiral derivatizing reagents for high performance liquid chromatography. Chromatographia 56: 631 636. Ko, M.Y., Shin, D.H., Oh, J.W., Asegahegn, W.S. and Kim, K.H. (2006). Chiral separation of β blockers after derivatization with a new chiral derivatization agent, GATC. Arch. Pharm. Res. 29: 1061 1065. Bhushan, R. and Nagar, H., Enantioseparation of orciprenaline, betaxolol, and propranolol using HPLC and new chiral reagents based on 1,5-difluoro-2,4-dinitrobenzene. Anal. Lett. 29 (2014) 202-219. Figure 40

S. No. Table Literature reports with present study on chromatographic separation (in terms of: R S, LOD and resolution time) of enantiomers of Bel using different CSPs/chiral selectors/cdrs/cir CSP a /CDR c /Chiral Selector b /CIR d Technique used Resolution time (t R /k/run time) LOD R S Reference 5 Cellulose tris(3,5-dichlorophenyl- i NA NA 0.81 23 carbamate) a 6 Cellulose tris(3,5-dimethylphenyl- i 15.2/16.9 min (t R1 /t R2 ) NA 1.6 24 carbamate) a 7 8 9 10 13 Amylose tris(3,5-dimethoxyphenyl i 11.8/14.8 min (t R1 /t R2 ) carbamate) a 31.7/32.9 (t R1 /t R2 ) ( )-(α-methoxy-(α-(trifluoromethyl)phenylacetyl chloride b ii 19.8/20.0 (k 1 /k 2 ) 1,3-diacetoxy-1-(4-nitro-phenyl)-2-propyl 4.67/5.58 (k 1 /k 2 ) 0.2nmol/ isothiocyanate b ml ii 10 µg/ml 1.54 25 26 NA 1.18 Kim 2001) 2,3,4,6-tetra-O-acetyl-b-D-galactopyranosyl isothiocyanate b ii NA NA 6.32 (Ko, et al, 2006) 2,3,4,6-tetra-O-acetyl-b-D-glucopyranosyl ii NA NA 4.70 (Ko, et al, isothiocyanate b 2006) ii 21.48/23.88 (t R1 /t R2 ) 12pgmL -1 14 (R)-2-(5-fluoro-2,4-dinitrophenylamino)-3- (methylthio)propanoic acid b and 13pgmL -1 (S)-N-(1-cyclohexylethyl)-5-fluoro-2,4- ii 34.71/36.92 (t R1 /t R2 ) 12pgmL -1 dinitrobenzenamine b and 13pgmL -1 (R)-5-fluoro-2,4-dinitro-n-(1- ii 33.64/35.63 (t R1 /t R2 ) 12pgmL -1 phenylethyl)benzenamine b and 13pgmL -1 14 L-lysine/L-arginine c iii 1.62 Péter, 2001 11.72 (Bhushan and Nagar 2014) 9.65 (Bhushan and Nagar 2014) 8.70 (Bhushan and Nagar 2014) 5.50/6.45 (k 1 /k 2 ) NA 2.0 Bhushan and Thiong O, 1998 18 L-Glutamic acid d iii 10 min (run time) 1.2-1.8 µg 2.0 (Bhushan et al. 2015) CSP, chiral stationary phase; CDR, chiral derivatizing reagent; CIR, chiral inducing reagent; t R1 and t R2 are the retention time of first and second eluting isomer, respectively; k 1 and k 2, retention factor of first eluting isomer; run time, time taken by solvent system to migrate across the TLC plate. i, ii and iii represent the techniques used as direct HPLC, indirect HPLC and direct TLC separation, respectively. 41