New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

Similar documents
Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Fast, Accurate Environmental Testing

Introduction to Capillary GC

Understanding Gas Chromatography

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Trajan SGE GC Columns

Selection of a Capillary

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Selection of a Capillary GC Column

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs)

Evaluation of Capillary Columns for General Performance Parameters

Take Your Food Testing to the Next Level

Introduction to Capillary GC

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane

BP1 PONA BPX1. GC Capillary Columns BP1 PONA and BPX1

Ultra-Inert chemistry for Trace Level Analysis

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns

GC Analysis of Polybrominated Flame Retardants Application

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

Secrets of GC Column Dimensions

Chapter 27: Gas Chromatography

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Water Injections in GC - Does Water Cause Bleed?

Volatile organic compounds (VOCs):

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Introduction and Principles of Gas Chromatography

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Virtually Particle-Free Rt -Silica BOND Columns

Choosing the Correct GC Column Dimensions and Stationary Phase

Rtx -CLPesticides Columns Reduce Analysis Time; Reduce System Maintenance

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

Rtx-BAC Plus 1 and Rtx-BAC Plus 2 Columns Advanced Technology for Fast, Reliable Measurement of Alcohol in Blood

Activity in the FID Detection Port: A Big Problem if Underestimated

Gas Chromatography. Introduction

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

Application Note. Abstract. Authors. Introduction. Food Safety

How To Select the Correct GC Column. Simon Jones Application Engineer

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

NEW Rtx -BAC Plus 1 and Rtx -BAC Plus 2 Columns

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

GAS CHROMATOGRAPHY. Mobile phase is a gas! Stationary phase could be anything but a gas

GC Instruments. GC Instruments - Sample Introduction

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

2401 Gas (liquid) Chromatography

Introduction to Gas Chromatography

637. Thiamethoxam. HPLC method

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

GC Resolution Do You See What I See?

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Appendices References...49 Glossary Equations

4-methyl-1-phenyl-2-pyrrolidin-1-yl-pentan-1-one

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

Gas Chromatography (GC)

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Get Selective. By Jaap de Zeeuw

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

NCFS Sample Preparation and Instrumental Parameters

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Optimize Your Gas Chromatography Analysis Through the Use of a Retention Gap and Integrated Guard Column

Method for Characterization of Gum Rosin by Capillary Gas Chromatography

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

CHAPTER 6 GAS CHROMATOGRAPHY

Rely on Rxi -PAH Columns

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe

Fundamentals of GC: Introduction: Sample introduction:

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

Low Bleed Stationary Phases for Gas Chromatography

DET REPORT. 1.) CATALYTIC COMBUSTION IONIZATION DETECTION (CCID) - MORE CHARACTERISTICS OF THE SELECTIVITY FOR n PARAFFINS. NO.

GAS CHROMATOGRAPHY (GC)

Application Note. Abstract. Authors. Introduction

N-(1-carbamoyl-2-methyl-propyl)-1-(5-chloropentyl)indazole-3- carboxamide

Hiroyuki FUJITA 1 *, Takanori MAKINO1, Kenji INABA 1, Kazuki YAMAMOTO 2

This document is a preview generated by EVS

2-[[2-(4-ethyl-2,5-dimethoxy-phenyl)ethylamino]methyl]phenol

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

Jaap de Zeeuw Varian, Inc.. Middelburg, The Netherlands

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Methyl 1-[(4-fluorophenyl)methyl]indazole-3-carboxylate

Application Note 032

Transcription:

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

The World's First Non-metal 5% Phenyl Phase GC Column Rated to 430 C * Specially processed for thermal stability up to 430 C A true (5%-Phenyl)-methylpolysiloxane phase Individually tested for low bleed Rugged high temperature, polyimide coated, fused silica tubing Stable and Durable Even When Pushed to 430 C * After 23 Hours at 430 C only 1.5% retention difference App ID 16089 4 th injection 136 th injection Dimensions: 15 meter x 0.32mm x 0.10μm Part No.: 7EM-G015-02 Injection: Direct on column @ 43 C, 0.1uL Carrier Gas: Helium @ 1.9mL/min (35cm/sec) - constant flow Oven Program: 40 C for 2 min to 430 C @ 20 C for 10 min Detector: FID @ 430 C Sample: Paraffin Wax 8 10 12 14 16 18 20 22 min Still Flexible After 23 Hours at 430 C * At temperatures above 370 C, most of our competitors fused silica tubing will become brittle and randomly break. Our special new tubing is manufactured using a novel High Temperature Polyimide Resin material that shows minimal thermal degradation even at programmed temperatures up to 430 C. *430 C TPG Stability Test Evaluated by performing 185 programmed temperature runs, total 23 hours at 430 C. Polyimide tubing was still flexible as shown here. Phenomenex Web: www.phenomenex.com

Outperforms Agilent J&W DB-5ht Lifetime Comparison Longer Lifetime! Dimensions: 30 meter x 0.25mm x 0.10μm Injection: 1.0μL of test mix AG0-7578 Carrier Gas: Constant Flow Helium @ 1.9mL/min Oven Program: 120 C Isothermal Detector: Flame Ionization Detector (FID) @ 400 C Analyte: Pentadecane Zebron ZB-5HT Inferno Agilent J&W DB-5ht Columns were held at 400 C for 2 hours, then the oven was lowered to 120 C for Pentadecane analysis. Cycle was repeated. Bleed Profile 400 C Dimensions: 30 meter x 0.25mm x 0.10μm Injection: Null Injection @ 250 C Carrier Gas: Constant pressure of hydrogen @ 11psi Oven Program: 120 C for 3 min to 320 C at 30 C/min (hold 5 min) to 340 C at 30 C/min (hold 5 min) to 360 C at 30 C/min (hold 5 min) to 380 C at 30 C/min (hold 5 min) to 400 C at 30 C/min (hold 5 min) Detector: Flame Ionization (FID) @405 C Lower Bleed! 380 C Zebron ZB-5HT Inferno Agilent J&W DB-5ht All columns were new, never used, prior to this testing and purchased either directly from the original manufacturer or through an authorized distributor. All testing was carefully controlled to ensure conditions were similar for all columns involved. The comparative data is not representative of every application. Agilent and J&W are registered trademarks of Agilent Technologies. Phenomenex Web: www.phenomenex.com

Making the World s Highest Temperature GC Column Engineered Self Cross-linking (ESC) Technology... Column bleed is the loss of lower molecular weight stationary phase pieces (MS Ions 355, 281, 207, 73) that are either the result of impurities in the starting polymer or the decomposition of the phase at elevated temperatures. ESC bonding technology reinforces the stationary phase by incorporating ladder bridges into the polymer backbone. The process begins with a careful fractionation of the base polymer, which eliminates low molecular weight impurities and enhances coating efficiencies. The columns are then cross-linked and surface bonded using an aggressive catalyst forming an interpenetrating network, which provides enhanced column durability and extremely low bleed levels even at programmed 430 C temperatures! Special High Temperature Polyimide Coating... Capillary GC columns are externally coated with a thermoplastic polymer known as polyimide resin. It stabilizes the internal glass capillary tubing and allows the columns to be flexible even at elevated temperatures. Standard polyimide resin pyrolyzes at temperatures above 370 C making the tubing unstable. The new Zebron ZB-5HT Inferno column utilizes a polyimide resin material that shows minimal thermal degradation even at programmed temperatures up to 430 C. The new resin material is also the reason for the graphite black appearance of the capillary tubing. However, unlike traditional tubing that darkens due to oxidation, this tubing will provide long lifetime even at 430 C.

Hot 5HT Applications App ID 16054 App ID 16055 Butter Triglycerides Dimensions: 15 meter x 0.32mm x 0.10μm Part No.: 7EM-G015-02 Injection: On-Column 2 μl @ 403 C Carrier Gas: Constant Flow Helium, 1.8 ml/min Oven Program: 100 C to 400 C at 14 C/min for 10 min Detector: Flame Ionization (FID) @ 400 C Polybrominated Diphenyl Ethers (PBDEs) Dimensions: 30 meters x 0.25mm x 0.10μm Part No.: 7HG-G015-02 Injection: Pulsed 2 μl @ 350 C Carrier Gas: Constant Flow Helium, 1.3 ml/min Oven Program: 125 C to 380 C at 22 C/min for 15min Detector: Mass Selective (MSD) @ 45-800 amu Analytes: 1. BDE-25 7. BDE-66 13. BDE-154 2. BDE-28 8. BDE-77 14. BDE-153 3. BDE-75 9. BDE-100 15. BDE-138 4. BDE-49 10. BDE-119 16. BDE-183 5. BDE-71 11. BDE-99 17. BDE-190 6. BDE-47 12. BDE-85 18. BDE-203 Analytes were 2.5ppm in isooctane. Pulsed splitless injection at 50psi using direct connect liner. App ID 16056 App ID 16057 Olive Oil Dimensions: 30 meters x 0.25mm x 0.10μm Part No.: 7HG-G015-02 Injection: On-Column 0.1 μl @ 223 C Carrier Gas: Constant Flow Helium, 1 ml/min Oven Program: 220 C for 1 min to 400 C at 8 C/min for 4 min Detector: Flame Ionization (FID) @ 415 C Sample was 1% in dichloromethane. H-53 Diesel Fuel Dimensions: 30 meters x 0.25mm x 0.10μm Part No.: 7HG-G015-02 Injection: On-Column 0.1 μl @ 53 C Oven Program: 50 C for 6 min to 400 C at 20 C/min for 15 min Carrier Gas: Constant Flow Helium, 1.3 ml/min Detector: Flame Ionization (FID) @ 400 C Analytes: 1. Decane (C10) 2. Tetracontane (C40) Fuel was 1% dichloromethane with 50ppm markers.

Ordering Information Zebron ZB-5HT Inferno Capillary Columns ID (mm) df (μm) Temp. Limits ( C) Part No. Price 15-Meter 0.25 0.10-60 to 400/430 7EG-G015-02 0.32 0.10-60 to 400/430 7EM-G015-02 20-Meter 0.18 0.18-60 to 400/430 7FD-G015-08 30-Meter 0.25 0.10-60 to 400/430 7HG-G015-02 0.32 0.10-60 to 400/430 7HM-G015-02 Guardian Integrated Guard Columns Integrated Guard (m) Column Dimension Part No. Price 5-meter 30 meter x 0.25mm x 0.10µm 7HG-G015-02-GGA High Temp Septa Part No. Description Unit Price AG0-4696 PhenoRed-400 Injector Septa 50/pk AG0-4697 PhenoRed-400 Injector Septa 100/pk ZB-5HT is guaranteed to outperform any competitor s HT column or it s yours FREE! No questions asked. 2006 Phenomenex, Inc. All rights reserved. Phenomenex is a registered trademark of Phenomenex, Inc. Zebron, ZB-5HT Inferno, Engineered Self Cross-linking (ESC) and Guardian are trademarks of Phenomenex, Inc. Agilent and J&W are trademarks of Agilent Technologies, Inc. Phenomenex is in no way affiliated with Agilent Technologies, Inc. High Temp Graphite Ferrules Part No. Description Unit Price AG0-4698 0.4mm Ferrule ID: 1 /16" to 0.4mm 10/pk AG0-4699 0.4mm Ferrule ID: 1 /16" to 0.4mm 50/pk AG0-4701 0.5mm Ferrule ID: 1 /16" to 0.5mm 10/pk AG0-4702 0.5mm Ferrule ID: 1 /16" to 0.5mm 50/pk 4261_I