IPNDV Working Group 3: Technical Challenges and Solutions Nuclear Material (3) Technology Data Sheet

Similar documents
TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL

Report 2016 Technology Demonstration Workshop (TDW) on Gamma Imaging-External

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

Application of Nuclear Physics

Characterization of Large Structures & Components

Compton Camera. Compton Camera

NUCL 3000/5030 Laboratory 2 Fall 2013

Radionuclide Imaging MII Positron Emission Tomography (PET)

Modular Survey Spectrometer and Compton Imager

Technology Demonstration Workshop on Gamma Imaging IAEA Headquarters, Vienna and IAEA Laboratories, Seibersdorf October 2015

Polaris 3-D CdZnTe (CZT) Gamma-Ray Imaging Spectrometers

Stand-off Nuclear Radiation Detection

NGN PhD Studentship Proposal

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

Comparison of Several Detector Technologies for Measurement of Special Nuclear Materials i

A NEW GENERATION OF GAMMA-RAY TELESCOPE

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

CZT Gamma Spectrometry Applied to the In-situ Characterisation of Radioactive Contaminations

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

Organisation for the Prohibition of Chemical Weapons. Inspectorate

The Best Gamma-Ray Detector

Physics in Nuclear Medicine

PYCKO SCIENTIFIC LIMITED

New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors

Radioisotopes and PET

Basic hands-on gamma calibration for low activity environmental levels

Compton suppression spectrometry

TECHNICAL WORKING GROUP ITWG GUIDELINE ON LABORATORY APPLICATIONS OF HIGH-RESOLUTION GAMMA SPECTROMETRY

Morgan Burks, LLNL. Photo: On the way to El Centro Atómico Bariloche, in Patagonia (Argentina) for a reconnaissance trip. 1 Q1135-PPT# author

Design and production of Scintillation Detectors

A Report On DESIGN OF NEUTRON SOURCES AND INVESTIGATION OF NEUTRON BASED TECHNIQUES FOR THE DETECTION OF EXPLOSIVE MATERIALS

Atomic & Nuclear Physics

IAEA-CN-184/115. P.O. Box 2008, MS-6165 Oak Ridge, TN , USA

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

PHDS Corporation, 3011 Amherst Road, Knoxville, TN 37921, USA

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

New methodology for source location and activity determination in preparation of repairing or decommissioning activities

PINS3-CF. Portable Chemical and Explosive Identification System

The CSPD-1 y-ray Vision System

SCANNING OF CARGO CONTAINERS BY GAMMA-RAY AND FAST NEUTRON RADIOGRAPHY

Detection of explosives and fissile material based on neutron generators, survey of techniques and methods. M. Bruggeman

General Overview of Radiation Detection and Equipment

Design of an Integrated Inspection System For Detection of Explosive and Illicit Materials

Distance from the face of the detector to the surface of the item being measured.

Radioactivity. Lecture 6 Detectors and Instrumentation

P7 Radioactivity. Student Book answers. P7.1 Atoms and radiation. Question Answer Marks Guidance

CHEMISTRY 170. Radioisotopes

Radiation safety of the Danish Center for Proton Therapy (DCPT) Lars Hjorth Præstegaard Dept. of Medical Physics, Aarhus University Hospital

1 of :32

Physics 3204 UNIT 3 Test Matter Energy Interface

Lecture 5: Tomographic nuclear systems: SPECT

Introduction to SPECT & PET TBMI02 - Medical Image Analysis 2017

Fissile material experiments at the Device Assembly Facility

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

Training program for x-ray inspection film (RT)

A Study On Radioactive Source Imaging By Using A Pixelated CdTe Radiation Detector

Survey Meter OD-01 Address: Phone: Fax: URL:

DEVELOPMENT OF ADVANCED NEUTRON INDUCED PROMPT GAMMA- RAY ANALYSIS SYSTEM FOR SURVEY OF ANTI-PERSONNEL MINES

What is scintigraphy? The process of obtaining an image or series of sequential images of the distribution of a radionuclide in tissues, organs, or

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

Recent improvements in on-site detection and identification of radioactive and nuclear material

Regulatory Considerations in the Licensing of a Mobile Backscatter X-ray Device used in Security Screening

A new approach in the detection of weak γ-ray peak of the radioactive. waste in tomography γ scanning

PRACTICAL GAMMA SPECTROSCOPY ASSAY TECHNIQUES FOR LARGE VOLUME LOW-LEVEL WASTE BOXES

In-Situ Characterization of Underwater Radioactive Sludge

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

Identify Isotopes with the ICS-4000 Gamma Ray Spectrometer!

ISO INTERNATIONAL STANDARD

A Proposal of Nuclear Materials Detection and Inspection Systems in Heavily Shielded Suspicious Objects by Non-destructive Manner.

Nuclear Physics Applications to Healthcare and Security. Andy Boston

ORIGAMIX CURRENT STATE OF A TECHNOLOGY TRANSFER PROJECT FROM SPACE GRADE HIGH ENERGY SPECTRO-IMAGER TO COMMERCIAL GRADE GAMMA CAMERA

Efficiency and Attenuation in CdTe Detectors

Mitigation of External Radiation Exposures

Application Note. InSpector 1000-based CZT Package for Nuclear Power Plant Isotope Mix Analysis

Monitoring of Ionizing Radiations facilities Experience and challenge

Compton Imaging with Coincidence Measurements for Treaty Verification Purposes

Structure of Biological Materials

What is Albira and How Does the System Work and Why is it Differentiated Technology? Page 1

Detector R&D at KIPAC. Hiro Tajima Kavli InStitute of Particle Astrophysics and Cosmology

Preparation of Standard Source as a Petri Dish for Plant by Using

Chapter Seven (Nuclear Detectors)

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

Establishing an ISO-CART Measurement Station to Meet Government Burial Regulations for Radioactive Material

Radiation Detection and Measurement

Expand the probe idea functionality (above points) to larger imaging systems. First Applications, Probes, Isotopes

Department of Chemistry, University of Rochester, Rochester, N.Y POC:

2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier

Computational study to enhance threat detection of radiation portal monitors:

PINS3-CW. Portable Chemical Identification System

PHYS 3650L - Modern Physics Laboratory

CHEMISTRY 130 General Chemistry I. Radioisotopes

Nuclear Medicine Intro & Physics from Medical Imaging Signals and Systems, Chapter 7, by Prince and Links

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

Travels with a Cyclotron. David Parker University of Birmingham

A MONTE CARLO SIMULATION OF COMPTON SUPPRESSION FOR NEUTRON ACTIVATION ANALYSIS. Joshua Frye Adviser Chris Grant 8/24/2012 ABSTRACT

Development of High-Z Semiconductor Detectors and Their Applications to X-ray/gamma-ray Astronomy

Chemical Engineering 412

David Goodman, Michael Streicher, Yuefeng Zhu, Zhong He, Senior Member, IEEE

Transcription:

Nuclear Material (NM) Technology Name: Gamma-Ray Imaging Physical Principle/Methodology of Technology: Gamma-ray imaging provides the location and shape information of gamma-ray emitting radionuclides. The technology can also determine the identity, activity, and mass of these radionuclides. A key informative output for the technology is an optical image of the scene overlayed with the gamma-ray image. This aids the user in visualizing the location of the radiation. Gamma-ray imaging techniques can be broadly separated into two groups: those based on mechanical collimation and those based on electronic collimation. There are several different mechanical collimation systems that have been developed, including: pinhole cameras, coded aperture, raster scanning, and Rotational Modulating Collimators (RMC). Compton cameras do not rely on any physical form of collimation, but instead use the kinematics of Compton scattering, as a form of electronic collimation, to determine the origin of a gamma-ray source. A range of detector materials could be used in a gamma-ray imaging system. These detector materials have their own set of advantages and disadvantages (for example, low/high energy resolution, cryogenic cooling/room temperature operation, cost). This will not be explored in any further detail now because it is covered in the High Resolution Gamma-Ray Spectroscopy Technology Data Sheet. Each technology variant has both its advantages and disadvantages, details of which can be seen in Table 1 below. For mechanical collimation systems, there is a general tradeoff between spatial resolution and sensitivity. For example, a high spatial resolution leads to low sensitivity and high sensitivity leads to low spatial resolution. Compton cameras have an intrinsically low efficiency, especially for low energy photons. Table 1. Advantages and Disadvantages of Gamma-Ray Detector Systems Technology Advantages Disadvantages Pinhole Collimator High spatial resolution, better at lower energies, direct image Low sensitivity, small Field of View (FOV) typically 40 o 40 o generation Coded Aperture High sensitivity, high spatial Small FOV typically 40 o 40 o resolution, better at lower energies, good point spread function Raster Scanning Low cost single detector option, large FOV (4omnidirectional), better at lower energies, can dwell on regions of interest, direct image generation Long acquisition times Rotational Modulating Collimators Low cost single detector option, can be effective across wide energy range Long acquisition times, heavy, small FOV, non-ideal point spread function, post processing needed to remove image artifacts 1 Page

Compton camera Large FOV (4omnidirectional), lightweight (no shielding), better at high energies Low efficiency, unable to image low energy photons, low angular resolution compared to collimation techniques, non-ideal point spread function Potential Monitoring Use Cases (pre-dismantlement, dismantlement, post-dismantlement, storage stage): All Used to measure U, Pu, or U and Pu: U and Pu For detection technologies, what does the method determine/measure (e.g., presence of nuclear material, isotopics, mass, etc.)? Gamma-ray imaging can provide everything gamma-ray spectroscopy can do as well as giving the location/shape information of the radioactive material. The method can determine/measure: Presence of nuclear material Identification of radioisotopes Activity Mass Location Shape Physical Description of Technology (e.g., approximate size, weight): Weight range: 2.5 kg 45 kg Size range: 18 9 9 cm 30 23 15 cm Time Constraints (e.g., measurement times including distance from object, time to install the equipment): Time to install: 2 minutes 5 hours. This depends on the technology variant. Measurement time: Depends on the dose rate from the source and the intrinsic efficiency of the imaging method. Measurement time to measure 500 g of Pu (0.1 239 Pu/ 240 Pu) or 500 g of 235 U at 1 m from the surface of the container (order of magnitude: seconds, minutes, hours, days): Minutes to hours 2 Page

Will this method work in the presence of shielding? If so, what is the maximum amount of shielding that will still allow the method to work? As the gamma-ray photon energies from U and Pu are low in energy, this technology will only work with small amounts of shielding. Low energy photons are easily scattered by low Z materials (i.e., explosives but the scattered radiation can also be imaged indicating where nearby materials may occur) and easily attenuated by high Z materials (i.e., metals). Technology Complexity (e.g., hardware, software, and ease of use by personnel): The technologies can be complex and may involve the integration of the following components: Detector material Readout electronics (ASICS) Embedded computing Temperature regulation, cryogenic cooling Image reconstruction software Mechanical collimator Motors/motor controllers The complexity of the system is hidden from the end user. Systems typically have a non-expert and expert user interface. Infrastructure Requirements (e.g., electrical, liquid nitrogen, etc.): The various Commercial Off-the-Shelf (COTS) systems have a battery life of between 1 to 10 hours. They can also be operated through mains power. Wired and wireless connectivity Technology Limitations/Variations (e.g., detection limits for nuclear material, operational temperature range, differences in technology detector materials): System specific, various systems operate within the temperature range of: -20 o C to +60 o C. The detector materials currently used in COTS equipment include High Purity Germanium (HPGe), Cadmium Zinc Telluride (CZT), Cadmium Telluride (CdTe), Caesium Iodide (CsI) and Bismuth Germanate (BGO). These materials have different detection efficiency and energy resolution properties. Specific equipment limitations include: Compton cameras cannot image low energy photons and have a low efficiency Pinhole cameras have a low sensitivity when compared to coded aperture systems, as the single pinhole severely restricts the number of photons arriving at the detector Raster scanning is comparable to a pinhole in sensitivity RMC systems are slower than coded apertures but faster than pinholes 3 Page

Information Collected by the Technology (used to help determine if an information barrier is required for use): Gamma-ray spectrum, source identification, source activity, source mass, source location, and shape information. An information barrier would be required. Safety, Security, Deployment Concerns: Gamma-ray imaging is a passive detection technology, so there will be limited safety concerns. Security concerns may arise from the technology being able to detect sensitive information. There are minimal deployment concerns. Most systems are deployable on a tripod and are battery powered. The only COTS system that requires cryogenic cooling is mechanically cooled and therefore does not require the use of liquid nitrogen. Technology Development Stage (Technology Readiness Level, TRL): There are several COTS items (TRL 9) that are available. National labs and universities are also developing technologies that are at the various TRL levels. Where/How the Technology Is Currently Used (e.g., international safeguards, border protection): Nuclear Industry Decommissioning Area monitoring Inspection (hotspots) Health physics surveying Safeguards National Security Border protection First responder/emergency response Medical imaging Single Photon Emission Computed Tomography (SPECT) Astronomy Space-based telescopes for imaging the gamma-ray universe Examples of Equipment: Company Name Equipment Name Equipment Type Detector Material Canberra Cartogram Pinhole camera CsI or BGO Canberra IPIX Coded aperture CdTe 4 Page

Createc NVisage Raster scanning CZT H3D Polaris-H Compton camera CZT CEA HiSPECT Coded aperture CZT PHDS GeGi Compton camera HPGe (also pinhole mode) RMD RadCam Pinhole camera/ coded aperture CsI 5 Page