NEXAFS data normalization procedure: A case study at the C K edge *

Similar documents
FEASIBILITY OF IN SITU TXRF

Protocol for drain current measurements

Supporting Information. Effect of Backbone Chemistry on the Structure of Polyurea Films Deposited by Molecular Layer Deposition

Beamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples

Surface Chemistry of Alanine on Ni{111} Supporting Information

SUPPLEMENTARY INFORMATION

Synchrotron radiation: A charged particle constrained to move in curved path experiences a centripetal acceleration. Due to it, the particle radiates

On surface synthesis of a 2D boroxine framework: a route to a novel 2D material?

Introduction to Near Edge X- ray Absorption Fine Structure of Molecules Maddalena Pedio TASC-INFM Trieste

Synchrotron radiation: A charged particle constrained to move in curved path experiences a centripetal acceleration. Due to this acceleration, the

Surface and Electronic Structure Study of Substrate-dependent Pyrite Thin Films

Keywords: electron spectroscopy, coincidence spectroscopy, Auger photoelectron, background elimination, Low Energy Tail (LET)

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

High Accuracy EUV Reflectometry and Scattering at the Advanced Light Source

A new method to suppress high-order harmonics for. synchrotron radiation soft x-ray beamline*

Knot undulator to generate linearly polarized photons with low on-axis power density. Abstract

Development of a Compact XAFS Measurement Chamber under Atmospheric Pressure in the Soft X-ray Region

ABSOLUTE AIR-KERMA MEASUREMENT IN A SYNCHROTRON LIGHT BEAM BY IONIZATION FREE-AIR CHAMBER

Giant Gating Tunability of Optical Refractive Index in Transition Metal Dichalcogenide Monolayers

Two important parameters required for an effective photocathode for Free Electron Lasers

SLS Symposium on X-Ray Instrumentation

Upgrade of the FLASH beamlines New diagnostic and beam transport tools

Spectroscopy with Free Electron Lasers. David Bernstein SASS Talk January 28 th, 2009

structure and paramagnetic character R. Kakavandi, S-A. Savu, A. Caneschi, T. Chassé, M. B. Casu Electronic Supporting Information

A2. Light Source. ( i ) Units of light intensity

Introduction to X-ray Photoelectron Spectroscopy (XPS) XPS which makes use of the photoelectric effect, was developed in the mid-1960

Supporting Information s for

Small-Angle X-ray Scattering (SAXS)/X-ray Absorption Near Edge Spectroscopy (XANES).

Takeo Watanabe Center for EUVL, University of Hyogo

Vacuum System of Synchrotron radiation sources

Simulations and design for soft X-ray beamlines at MAX IV. Rami Sankari

Investigation of Ti2AlC and TiC by soft x-ray emission spectroscopy

FUNDAMENTAL PARAMETER METHOD FOR THE LOW ENERGY REGION INCLUDING CASCADE EFFECT AND PHOTOELECTRON EXCITATION

Supporting Information

Nano-Lithography. Edited by Stefan Landis

Supporting Information. for. Advanced Materials, adma Wiley-VCH 2005

X-ray Absorption at the Near-edge and Its Applications

X-Ray Photoelectron Spectroscopy (XPS)

Full-color Subwavelength Printing with Gapplasmonic

Auger Electron Spectroscopy

Development of multilayer mirror based soft X-ray polarimeter

Photoemission Electron Microscopy (PEEM)

Graphene field effect transistor as a probe of electronic structure and charge transfer at organic molecule-graphene interfaces

Emission Spectrum of Atomic Gases. Prelab Questions

Spectro-microscopic photoemission evidence of surface dissociation and charge uncompensated areas in Pb(Zr,Ti)O 3 (001) layers

Surface Plasmon Resonance. Magneto-optical. optical enhancement and other possibilities. Applied Science Department The College of William and Mary

Supporting Online Material for

Spectromicroscopy of interfaces with synchrotron radiation: multichannel data acquisition

Lasers PH 645/ OSE 645/ EE 613 Summer 2010 Section 1: T/Th 2:45-4:45 PM Engineering Building 240

X-ray Photoelectron Spectroscopy/ Electron spectroscopy for chemical analysis (ESCA), By Francis Chindeka

SSRL XAS Beam Lines Soft X-ray

Introduction to Synchrotron Radiation and Beamlines

PEEM and XPEEM: methodology and applications for dynamic processes

EXPERIMENT 5:Determination of the refractive index (µ) of the material of a prism using sprectometer

Abstract... I. Acknowledgements... III. Table of Content... V. List of Tables... VIII. List of Figures... IX

Problem Set 2 Solutions

Supporting Information. Chlorine in PbCl 2 -Derived Hybrid-Perovskite Solar Absorbers

Lecture 5. X-ray Photoemission Spectroscopy (XPS)

Paolo Tosi Dipartimento di Fisica - Università di Trento

Resist-outgas testing and EUV optics contamination at NIST

DUV ( nm ) Characterization of Materials: A new instrument, the Purged UV Spectroscopic Ellipsometer,

ATOMIC SPECTRA. To identify elements through their emission spectra. Apparatus: spectrometer, spectral tubes, power supply, incandescent lamp.

SUPPLEMENTARY INFORMATION

Optical Properties of Thin Semiconductor Films

Importance of realistic surface related properties as input to e-cloud simulations.

The Chemical Control of Superconductivity in Bi 2 Sr 2 (Ca 1 x Y x )Cu 2 O 8+±

Supporting Information

David Martin High Precision Beamline Alignment at the ESRF IWAA, Grenoble 3-7 October 2016

Fall 2014 Nobby Kobayashi (Based on the notes by E.D.H Green and E.L Allen, SJSU) 1.0 Learning Objectives

Optical Properties of Copper Phthalocyanine(CuPc)Thin Films

Ternary blend polymer solar cells with enhanced power conversion efficiency

Design, Construction and Performance of the Infrared. Microscopy Beamline (BL-15) in the SR center

Supplementary Information for. Silver Nanoparticles Embedded Anti-microbial Paints Based on Vegetable Oil

Measurement of the Complex Index of Refraction for UO x in the Extreme Ultraviolet

Spectroscopy Meditsiiniline keemia/medical chemistry LOKT Spectroscopy

Ms. Monika Srivastava Doctoral Scholar, AMR Group of Dr. Anurag Srivastava ABV-IIITM, Gwalior

Electronic Supplementary Information

In order to determine the energy level alignment of the interface between cobalt and

Supplementary Figure S1 Anticrossing and mode exchange between D1 (Wood's anomaly)

The Emission Spectra of Light

Nuclear contribution into single-event upset in 3D on-board electronics at moderate energy cosmic proton impact

Local Anodic Oxidation with AFM: A Nanometer-Scale Spectroscopic Study with Photoemission Microscopy

Damage to optics under irradiations with the intense EUV FEL pulses

Fourier Transform Infrared. Spectrometry

X-Ray Microscopy with Elemental, Chemical, and Structural Contrast

Surface Characte i r i zat on LEED Photoemission Phot Linear optics

Supporting Information

Anatomy of an XAFS Measurement

NEW CORRECTION PROCEDURE FOR X-RAY SPECTROSCOPIC FLUORESCENCE DATA: SIMULATIONS AND EXPERIMENT

X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND TRANSPORT. University of California Davis. Dorthe Wildenschild & Annette Mortensen

Experimental 2.1 Introduction. Ultra high vacuum.

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

Industrial Applications of Ultrafast Lasers: From Photomask Repair to Device Physics

PB I FEL Gas-Monitor Detectors for FEL Online Photon Beam Diagnostics BESSY

Coatings for CO Laser Optics

X-ray K-absorption spectral studies of cobalt (II) hydroxamic mixed ligand complexes

The design of an integrated XPS/Raman spectroscopy instrument for co-incident analysis

Toward Clean Suspended CVD Graphene

Application of the GD-Profiler 2 to the PV domain

Effective Areas. Herman L. Marshall Nov. 17, 2014

Transcription:

NEXAFS data normalization procedure: A case study at the C K edge * n this example we shall demonstrate the procedure to normalize the C K edge NEXAFS spectrum obtained from drain current measurements on an as coated polyacrylamide (PAM) thin film. The incident photon flux has energy dependence arising due to the non uniform absorption (irregular ups and downs) by the beamline optics (monochromator, grating, mirror etc.). Therefore data ( ) should be divided by incident flux to remove the optics effects. To measure this incident flux a gold (gold is very good candidate as it has no absorption in the C, N K edge regions and a very small absorption in O K edge region) is placed before the to enable simultaneous measurement of data and incident flux. Let us call this current ( ). Then NEXAFS normalized data can be represented as R( ) ( ) ( ) Unfortunately, the is normally contaminated by adventitious carbon. Also it is not possible to clean/replace the for every experiment. Therefore a properly clean gold/copper is used as a along with the same gold used for the actual (Henceforth we shall take the clean to be gold. t may be kept in mind that copper can be used as well).

ntensity (pico Amps) ntensity (pico Amps) 2 15 1 5 28 29 3 31 32 6 5 3 2 1 polymer 28 285 29 295 3 35 31 315 32 clean Au Fig. 1: The and gold data along with corresponding data. 7 6 / gold/ 5 ntensity (a.u.) 3 2 1 28 29 3 31 32 Fig: 2: Data obtained after dividing by corresponding currents.

Now one can get rid of the effect of adventitious carbon as follows. R( ) Au (, t) (, t) (, t) (, t) (1) As the two experiments (with and gold) are done at two different times (different synchrotron flux) the parameter t is shown, however, the effect of time cancels out. Note that if the X axis of the two measurements ( and gold) do not match interpolation is required. R(h 1.8 1.6 1. 1.2 1..8.6..2 R( ). 28 285 29 295 3 35 31 315 32 Photon energy (ev) Au (, t) (, t) (, t) (, t) Fig 3: Corrected data Data alignment However, due to beam position shift as well as mechanical movements of beamline optical components the flux vs. energy behavior is not identical at different times. Therefore the data taken at two different times should be aligned before the above normalization procedure as described below.

Drain current (pa) 12 8 a Mesh drain current data as obtained () (clean gold) 28 285 29 295 3 35 31 315 32 Drain current (pa) 5 3 2 Magnified view of selected region indicated above b () (clean gold) align current dips 2.2 ev 292 293 29 295 296 297 295.2 ev Fig. 1: Procedure for data alignment. (a) Drain currents from passivated gold as obtained. Prominent features in spectra are to be aligned. For the C K edge the best chosen feature is the 2 nd major dip in the spectrum as indicated by vertical lines; (b) Magnified view of the region of the 2 nd dip in the spectra as indicated by the dashed box in (a).

After alignment 12 () (clean gold) Drain current (pa) 8 295.2 ev 28 285 29 295 3 35 31 315 32 Fig. 2: After the dips have been aligned. Absolute energy calibration Absolute energy calibration is performed to determine the X axis precisely and generally performed using gas phase absorption (eg. Ne and/or N 2 ) or by photoemission of known. From calibration data the position of the above mentioned feature used in relative energy calibration is determined. For the C K edge the value was found to be 29.5 ev 1, i.e., both and clean gold spectra should be shifted by, 29.5 295.2.7 ev. 1 This particular value depends on the particular synchrotron beamline where the experiments are performed. n our case it was the BL 8.1 L BEAR beamline of the Elettra Synchrotron (Trieste, taly).

Absolute energy calibration 12 () (clean gold) Drain current (pa) 8 29.5 ev 28 285 29 295 3 35 31 315 Fig. 3: After aligning the dips to the correct energy value obtained from gas phase measurements. After alignment and absolute energy correction of all data (, ; gold, ) one can calculate R( ) using eqn. (1). 2.5 2. before energy correction (incorrect) after energy correction (correct) R(h) (a.u.) 1.5 1..5. 28 285 29 295 3 35 31 315 32 Photon energy (ev) Fig. : Final energy corrected data. * For further details please contact: Subhrangsu Mukherjee (email: smkjee@gmail.com)