ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Similar documents
ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

PHOENIX CONTACT - 04/2016. Features

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

16 Input AC Block I/O Module

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

32 Input AC Block I/O Module

Operating Instructions for Digital Manometer. Model: MAN-SD

PHASED OUT. FL ballasts Electronic dimming. PCA TC BASIC Y II, W BASIC compact

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

BMXART0814 analog input module M340-8 inputs - temperature

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

American Zettler AZ742 RELAY Datasheet

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

TeSys circuit-breakers

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

BMXART0814 analog input module M340-8 inputs - temperature

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

FL ballasts Electronic dimming. PCA TC ECO Y II, W ECO compact

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

DC/DC regulator Input V Output up to 16 A

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

E2T0 DVP

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Thermal-Magnetic Circuit Breaker 2210-T2...

Non-Contact Safety Systems CMS

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

POINTS OF CAUTION BEFORE USE...

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

473-SHX Dew Point Mirror

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DIGITAL THERMOMETER OPERATOR S MANUAL

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Thermal-Magnetic Circuit Breaker 2210-S2..

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Lamp and Control Panel (Lamp Panel)

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Pressure Display Controller

LEDlight 20 W Universal dimmable series

Thermal-Magnetic Circuit Breaker 2210-S2..

XJ4 Transmitter. Installation Guide. Z ISO9001 TECHNOLOGY & QUALITY

Drive electronics pq12

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

SUBJECT TO CHANGE WITHOUT NOTICE

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

E8EB-N0C2B E8EB-N0B2B

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

473 Dew Point Hygrometer

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

LEDlight 30 W Universal dimmable series

Capacitive Sensors. Contents

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Thermal-Magnetic Circuit Breaker 2210-S2..

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

FAZ tripping characteristics at 30 C: B, C, D to IEC/EN FAZ tripping characteristics at 30 C: R to IEC/EN

MAU200 Series. 1W, High Isolation SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Digital display Pressure range ON/OFF output Linear output Model No Positive pressure 0 to 98 kpa (0 to 1 kgf/cm 2 ) NPN open collector o 1 to o5

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

Analog - Digital multimeters

LED light engines LED linear / area

XM1 Motor Protection Relay. Manual XM1 (Revision B)

473 Dew Point Hygrometer

user's manual nx frequency converters resolver option board opt-bc

General characteristics, Products

Thermal-Magnetic Circuit Breaker 2210-S2...

BMXART0814 analog input module M340-8 inputs - temperature

Thermal-Magnetic Circuit Breaker 2210-S2...

MCB NB1-63H Miniature Circuit Breaker

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

Analogue Meters CQ2x07 series

24 volts (0.25 amps current-limited)

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

Acceleration/Velocity/Displacement VIBRATION METER

LED light engine / OLED LED compact. Uready2apply DLA G1 SNC China domestic

DATA SHEET. Thermocouple module with digital I²C-Interface - THMOD-I²C. Characteristic features. Areas of application. Features.

THERMOCOUPLE CHARACTERISTICS TRAINER

Type Function Output config. Auxiliary Case Page

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Alternating Current (AC): Alternating Current is electric current that reverses directions at regular intervals.

LED light engines LED compact. Module DLE G4 ADV Modules DLE

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Pressure. 1 Fitting PA R - N R2

für for T5-Lampen fluorescent in Multi-Lamp-Technologie

Transcription:

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER CAUTION: This equipment is designed for connection to mains voltages and must be used in accordance with this guide. If it is not, the safety protection provided by the equipment may be impaired. This equipment relies on double / reinforced insulation for safety and does not require a protective earth. Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting from errors or omissions, and reserve the right of amendment without notice. Industrial Interface This document is issued by Industrial Interface Research Ltd and may not be reproduced in any way without the prior written permission of the company. June 2007 IIG-060902 Page 1

CONTENTS 1. INTRODUCTION 3 1.1 Hardware Features 3 1.1.1 Isolation Details 3 2. UNPACKING 3 3. CONNECTIONS 4 4. CONFIGURING THE ISOCON 5 4.1.1 Voltage Input: 6 4.1.2 Current Input 7 4.1.3 Millivolt (mv) Input 8 4.1.4 Potentiometer Input 9 4.1.5 Thermocouple Input 10 4.1.6 RTD Input 11 4.1.7 Output Configuration 12 5. CALIBRATING THE ISOCON 13 6. INSTALLATION 14 7. TROUBLESHOOTING 15 7.1 Incorrect Reading 15 7.2 Sensor Failure 15 8. SPECIFICATIONS ( @ 25 C) 16 Industrial Interface Ltd, Signal House, Unit 15, Alstone Lane Trading Estate Alstone Lane, Cheltenham, Gloucestershire, GL51 8HF Tel: 01242 251794, Fax: 01242 571683 sales@industrialinterface.co.uk www.industrialinterface.co.uk Page 2 IIG-060902

1. INTRODUCTION 1.1 Hardware Features The ISOCON-3 is a universal input Isolating Signal Converter. It can accept virtually every type of analogue input signal from millivolts to 40Vdc, ma, thermocouples, RTD s etc. It also produces 3 types of analogue output; voltage, ma source, or ma sink. The unit can be powered by any AC voltage between 90 and 264Vac at 50 or 60Hz. For DC voltage the ISOCON-6 is available which can be powered from any supply from 12 to 36Vdc and 12 to 32Vac. The instrument is packaged in a very compact 12.5mm wide enclosure which can be mounted on standard TS35 DIN-rail. The unit can also be equipped with 1 digital output which can be either a relay or an open collector output, or a second analogue output (see DUALCON-3). Note, units with above options are housed in a 17.5mm wide box. 1.1.1 Isolation Details The ISOCON-3 has full 3 port isolation of 1000V between the Input Stage, Output Stage and Power Supply. The process input and output are double insulated internally from the power supply for safety reasons. Additionally the process input and output are isolated from each other for functional reasons. 2. UNPACKING The instrument should be carefully inspected for signs of damage which may have occurred in transit. In the unlikely case that damage has been sustained, DO NOT use the instrument, as the safety insulation may have been compromised, but please retain all packaging for our inspection and contact your supplier immediately. The instrument comes with the following items as standard: 1 Isocon-3 Isolating Signal Converter 1 Isocon-3 User Guide If the instrument has been factory configured the input and output details will be listed on the Serial number label on the side of the unit. If this label is blank then the unit will be set to its default configuration which is 4-20mA input and 4-20mA source output. Please check that the details on the side label are correct, especially the power supply voltage and frequency. If re-configuration is required please refer to Section 4 of this manual. IIG-060902 Page 3

3. CONNECTIONS The ISOCON is housed in a compact DIN rail mounting enclosure, with 8 terminals, arranged in 4 rows of 2 terminals. Two rows are at the top of the front panel and 2 rows are at the bottom. All the sensor input terminals are on the bottom rows and the power supply and analogue outputs are on the top terminals. The diagram below shows how to connect all the different input, output and power supply types. 2 L 1 N 90 264VAC PSU 2 1 OUTPUT 12 +ve 24V Supply 10 - ve 0-10V 0(4)-20mA 4-20mA Sink Voltage Source Current Source Current Sink 12 10 INPUT 5 4 +ve - ve Input: ma, Volts, mv, T/C 2 Wire Transmitter 2 Wire RTD 125R to 1K 2 Wire Pot 5 4 3 24V Tx Supply 4-20mA Sink INPUT 6 3 Wire RTD 4 Wire RTD 1K to 100K 3 Wire Pot 3 6 Page 4 IIG-060902

4. CONFIGURING THE ISOCON WARNING DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED The ISOCON is an extremely versatile device which can support many different types of input. The unit is configured by turning the power off, selecting the internal switch settings required and turning the power back on. To open the ISOCON, 2 catches just below the outer terminal blocks must be pushed in gently, one at a time. The front of the case can then be pulled and the unit will come out of the box. Press here gently There are 3 switch banks, S1, S2, and S3, located inside the ISOCON as shown below: 1 Switch S3 12 10 11 12 ON = 1 OFF = 0 1 Switch S2 12 1 Switch S1 12 Switch 10 is OFF Switch 11 is ON Switch 12 is OFF Switch S1 and S2 configure the input type and range, and switch S3 configures the output type, range and a few additional functions. The switch settings are explained in the next few pages. The diagrams refer to switch positions 0 and 1, with 0 being OFF and 1 being ON. This is illustrated in the picture above. IIG-060902 Page 5

4.1.1 Voltage Input: Select the range from the table below and set Switch S1 to the required values. Voltage Switch S1 Range 0-1V 0 0 0 0 0 1 0 0 1 1 0 0 0-2V 0 0 0 1 0 0-4V 0 0 1 0 0 0-5V 0 1 0 0 0 0-7.5V 1 0 0 0 0 0-8V 0 0 1 1 0 0-10V 0 1 0 1 0 0-15V 1 0 0 1 0 0-20V 0 1 1 0 0 0-30V 1 0 1 0 0 0-40V 0 1 1 1 0 1-5V 0 1 0 0 1-5 to +5V 1 1 0 0 1-10 to +10V 1 1 0 1 0 1 0 0 1 1 0 0 Then select the required setting from the table below for switch S2 Voltage Range Switch S2 0-30V & 0-40V Ranges 0 0 1 1 0 0 1 1 0 0 0 0 All other Ranges Listed Above 0 0 1 0 1 0 1 0 0 0 0 0 WARNING DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED Please note that PC Software is available to provide information on switch settings for your input and output requirements. Page 6 IIG-060902

4.1.2 Current Input Select the range from the table below and set Switch S1 to the required values. Switch S1 ma Range 0-1mA 0 0 0 0 0 0 0 0 1 1 1 0 0-2mA 0 0 0 1 0 0-4mA 0 0 1 0 0 0-5mA 0 1 0 0 0 0-8mA 0 0 1 1 0 0-10mA 0 1 0 1 0 0-15mA 1 0 0 1 0 0-20mA 0 1 1 0 0 0-30mA 1 0 1 0 0 4-20mA 0 1 1 0 1 4-40mA 0 1 1 1 1 4-30mA 1 0 1 0 1-5 to +5mA 1 1 0 0 1-10 to +10mA 1 1 0 1 0 0 0 0 1 1 1 0 Then select the required setting from the table below for switch S2 ma Range Using Internal 24V Tx Supply for 4 to 20mA Unipolar Ranges (e.g. 0-20mA, 4-20mA) Bipolar Ranges (e.g. -10 to +10mA) Switch S2 1 1 0 1 0 0 1 1 0 0 1 0 1 1 0 0 0 0 1 1 0 0 0 0 1 1 0 0 1 0 1 0 0 0 0 0 WARNING DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED Please note that PC Software is available to provide information on switch settings for your input and output requirements. IIG060902 Page 7

4.1.3 Millivolt (mv) Input Select the range from the table below and set Switch S1 to the required values. Switch S1 mv Range 0-25mV 0 0 0 0 0 0 0 1 1 1 0 0 0-50mV 0 0 0 1 0-100mV 0 0 1 0 0-125mV 0 1 0 0 0-150mV 1 0 0 0 0-200mV 0 0 1 1 0-250mV 0 1 0 1 0-300mV 1 0 0 1 0-500mV 0 1 1 0 0-600mV 1 0 1 0 0-1000mV 0 1 1 1 0-1200mV 1 0 1 1-125 to +125mV 1 1 0 0-125 to +1000mV 1 1 1 1 0 0 0 1 1 1 0 0 And then select the required setting from the table below for switch S2 mv Range All Unipolar Ranges (e.g. 0-500mV) Bipolar Ranges (e.g. -125 to +125mV) Switch S2 0 1 0 0 0 0 1 1 0 0 0 0 0 1 0 0 1 0 1 0 0 0 0 0 WARNING DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED Please note that PC Software is available to provide information on switch settings for your input and output requirements. Page 8 IIG-060902

4.1.4 Potentiometer Input Select the range from the table below and set Switch S1 to the required values. Potentiometer Switch S1 Input 2 Wire 0-125R 0 0 0 0 0 0 0 1 1 1 0 1 2 Wire 0-250R 0 0 0 1 2 Wire 0-500R 0 0 1 0 2 Wire 0-625R 0 1 0 0 2 Wire 0-750R 1 0 0 0 2 Wire 0-1K 0 0 1 1 0 0 0 1 1 1 0 1 3 Wire from 0-1K to 0-100K 0 0 0 0 0 1 0 1 1 1 1 0 Then select the required setting from the table below for switch S2 Potentiometer Input 2 Wire Potentiometer 3 Wire Potentiometer Switch S2 0 1 0 0 1 0 0 1 0 0 0 1 0 0 1 1 0 0 1 1 0 0 1 0 WARNING DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED Please note that PC Software is available to provide information on switch settings for your input and output requirements. IIG060902 Page 9

4.1.5 Thermocouple Input Select the range from the table below and set Switch S1 to the required values. Switch S1 for Thermocouple Input Temperature Range in C Switch K J R S N E B T 0 to 100 400 to 500 0 to 50 0 0 0 0 0 0 0 0 to 200 400 to 600 0 to 100 0 0 0 1 0 to 400 400 to 800 0 to 200 0 0 1 0 T/C 0 to 800 400 to 1200 0 to 400 0 0 1 1 Type 0 to 125 400 to 525-50 to 50 0 1 0 0 0 0 0 K 0 to 250 400 to 650-50 to 100 0 1 0 1 0 0 1 J 0 to 500 400 to 900-50 to 200 0 1 1 0 0 1 0 R 0 to 1000 400 to 1400-50 to 400 0 1 1 1 0 1 1 S 0 to 150 400 to 550-100 to 50 1 0 0 0 1 0 0 N 0 to 300 400 to 700-100 to 100 1 0 0 1 1 0 1 E 0 to 600 400 to 1000-100 to 200 1 0 1 0 1 1 0 B 0 to 1200* 400 to 1600-100 to 400 1 0 1 1 1 1 1 T 0 to 175 400 to 575-200 to 50 1 1 0 0 0 to 350 400 to 750-200 to 100 1 1 0 1 0 to 700 400 to 1100-200 to 200 1 1 1 0 0 to 1400** 400 to 1800-200 to 400 1 1 1 1 0 0 0 Linearisation ON 0 Linearisation off 1 * n/a for types N and E CJC ON 0 ** n/a for types K, J, N and E CJC off 1 Then set switch S2 to the setting shown in the table below. Thermocouple Switch S2 All Ranges 0 1 0 0 1 1 1 0 0 0 0 0 WARNING DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED Please note that PC Software is available to provide information on switch settings for your input and output requirements. Page 10 IIG-060902

4.1.6 RTD Input Select the range from the table below and set Switch S1 to the required values. Range in C Switch S1 0 to 100 0 0 0 0 0 0 1 0 0 0 to 200 0 0 0 1 0 to 400 0 0 1 0 0 to 800 0 0 1 1-50 to 50 0 1 0 0-50 to 150 0 1 0 1-50 to 250 0 1 1 0-50 to 350 0 1 1 1-100 to 50 1 0 0 0-100 to 100 1 0 0 1-100 to 200 1 0 1 0-100 to 400 1 0 1 1-200 to 200 1 1 0 0-200 to 400 1 1 0 1-200 to 600 1 1 1 0-200 to 800 1 1 1 1 0 0 1 0 0 RTD linearisation ON 0 PT100 0 RTD linearisation off 1 PT1000 1 RTD 2 or 4 wire 0 RTD 3 wire 1 And then select the required setting from the table below for switch S2 RTD Switch S2 2 Wire RTD 0 1 0 0 1 0 0 1 0 0 0 1 3 Wire RTD 0 1 0 0 0 0 0 0 1 0 0 1 4 Wire RTD 0 1 0 0 0 0 0 1 0 1 0 0 WARNING DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED Please note that PC Software is available to provide information on switch settings for your input and output requirements. IIG060902 Page 11

4.1.7 Output Configuration Select the range from the table below and set Switch S3 to the required values. Switch S3 - Output Configuration 0 1 0 1 0 ma Source 0 Normal 0 1 0 1 0 0 ma Sink 1 Inverted o/p 0 1 0 1 1 Voltage Normal 0 0 Buttons Disabled High Burnout 0 Square Root 1 1 Buttons Enabled Low Burnout 1 4-20mA / 2-10V 0 0 Output value if fault on input signal 0-20mA / 0-10V 0 1 0-10mA / 0-5V 1 0 Front panel buttons can be disabled to allow 2-10mA / 1-5V 1 1 tamper-proof operation of the unit Examples: Switch S3 Examples 4-20mA Source 1 0 1 0 1 0 0 0 0 0 0 0 0-20mA Source 1 0 1 0 1 0 0 0 0 0 0 1 0-10V 1 0 1 0 1 1 0 0 0 0 0 1 4-20mA Sink 1 1 0 1 0 0 0 0 0 0 0 0 WARNING DO NOT OPEN UNIT OR ADJUST SWITCHES WITH POWER SUPPLY, INPUT OR OUTPUT CONNECTED Please note that PC Software is available to provide information on switch settings for your input and output requirements. Page 12 IIG-060902

5. CALIBRATING THE ISOCON When the unit is shipped the ISOCON will be calibrated for the input and output types and ranges noted on the side label. If this label is blank then the unit will be calibrated for 4-20mA input and 4-20mA source output. If the unit is re-ranged by the user it is necessary to re-calibrate the unit to obtain the maximum accuracy. The calibration is achieved by using both switches on the front panel to select the zero or span input and then using the switches as raise/lower buttons to adjust the output to the value required. The mode the unit is in is indicated by the colour of the LED: Green - Normal Operation Red - Span Adjust Yellow - Zero Adjust Setting of the zero and span points is non-interactive, so each point need only be set once. A typical calibration sequence would be as follows: LED Colour Mode Action Green Normal Apply full scale input. Press and release both buttons together to enter span mode RED Span Adjust Press raise / lower buttons to adjust output value Press and release both buttons together to return to normal mode Green Normal Apply zero scale input Press and release both buttons together to enter zero mode YELLOW Zero Adjust Press raise / lower buttons to adjust output value Press and release both buttons together to return to normal mode Green Normal Use product The unit is now calibrated and ready for use. Note: The unit will retain the new settings on power down. IIG060902 Page 13

When the unit is used to convert a thermocouple input it is important when calibrating to ensure that the thermocouple simulator employed is switched to automatic cold junction compensation and is at the same ambient temperature as the ISOCON. Note that this is not always easy to achieve, especially if the ISOCON is mounted in a warm cabinet. An altenative method is to use an icepoint reference and a mv source. 6. INSTALLATION The ISOCON s input and output circuits are classed as Separated Extra Low Voltage (SELV). This means that they must not be externally connected to voltages exceeding 30V ac or 60V dc, nor do they generate voltages above these limits internally. Where a higher voltage input is required a specially designed DIVIDER unit can be used to condition the input signal prior to connection to the process input terminals. The ISOCON unit clips directly onto Top Hat (TS35) symmetrical DIN rail. Ideally, mounting orientation should be vertical, with the power supply situated on the top face to minimise temperature rise. Good airflow around the unit will maximise reliability of the instrument. The use of bootlace ferrules is recommended on wiring terminations. Do not exceed terminal torque rating of 0.4 Nm use an appropriate screwdriver. The unit can be removed from the DIN rail by sliding a small screwdriver into the slot at the rear of the enclosure on the lower face and gently levering the metal clip, whilst lifting the unit from the rail. Although the unit is protected by a non-resettable internal fuse, it is essential that the following provisions are made in the installation: An anti-surge fuse with a voltage rating of 250V ac and a breaking capacity of 35A at 250V ac shall be wired in series with the supply live conductor (terminal 2). For 230V supplies T32mA should be used and for 115V supplies T63mA should be used. An appropriately marked or labelled switch or circuit breaker meeting the requirements of IEC947-1 and IEC947-3 shall be included in the supply installation in close proximity to the equipment, within easy reach of the operator. The supply neutral (terminal 1) should be connected to the mains supply neutral. Page 14 IIG-060902

7. TROUBLESHOOTING The ISOCON has some built in self diagnostic functions. If the LED on the front panel is flashing then the fault mode can be found by counting the number of flashes between gaps and using the table below to locate the problem. NOTE: Even if the LED is not lit, mains voltages could still be present ALWAYS isolate the mains supply before removing or examining the unit. No of Flashes Nature of Fault Corrective Action 0 (Green Unit Working no suspected Check Wiring and switch On) fault settings 2,3,4,5,6,8,9, Hardware Error, extreme Switch off unit, check switch 10,11,12 Green noise, poor supply settings, and wiring, and retry. If still faulty please contact supplier 7 Green RTD / Thermocouple burnout Repair RTD, T/C or wiring 3 or 4 Red Span point is too close to Change input span value and zero point retry 3 or 4 Zero point is too close to Change input zero value and Yellow span point retry No LED Power Failure Check supply lines and voltage 7.1 Incorrect Reading Check that Unit is configured for the correct Sensor Check that Input Scaling is as required. Check that Linearisation has not been set incorrectly. Check that Thermocouples have correct compensation cables, and polarity. Check that RTD is set for correct option 2, 3 or 4 Wire. Check that RTD leads are connected to appropriate terminal pins. 7.2 Sensor Failure Check that sensor wiring is correct. Check Thermocouple polarity. Check that all RTD leads are connected to correct terminals. Check that the ISOCON is configured for correct sensor. Check that applied voltage is not out of range. Check that applied current is not out of range. Check that applied millivoltage is not out of range. IIG060902 Page 15

8. SPECIFICATIONS ( @ 25 C) Operating Temperature 0 to 55 C (Storage: 40 to +100 C) Operating Altitude Sea Level to 2000m Humidity 0-90% RH Power Requirements AC Supply 90 to 264Vac 50 or 60Hz VA Rating 1.6VA ±10% typ (20mA in & out) 2.8VA ±10% (maximum load, tx supply) Transmitter Power Supply 21V to 28V @ up to 24mA Dependant on supply voltage and load Calibration accuracy ±0.05% full scale Linearity ±0.05% full scale Temperature Stability 50ppm / C Input Impedance: Current Input 15 ohms Voltage Input 1 Mohm Millivolt Input Greater Than 10 Mohm Thermocouple Burn Out Current: 500nA Nominal Cold junction compensation accuracy ±0.5 C over operating range Maximum Voltage Output 11.5 V into a minimum of 7Kohm Maximum Current Output 23.0 ma into a maximum of 1Kohm Time Response (90% of step change): 50ms ± 10ms Unit has full 3 port Isolation to 1kV between Power Supply, Input and Output. The unit can also withstand transients of 2.5kV for 50 µsecs. Dimensions 114.5 mm x 99mm x 12.5mm (HxDxW) Mounting DIN Rail TS35 Connections Screw Clamp with pressure plate Conductor Size 0.5 to 4.0 mm Insulation Stripping 12 mm Maximum Terminal Torque 0.4 Nm Weight Approx. 95g EMC BS EN61326 LVD Standards EN61010-1 Installation Category (IEC 664) II Pollution Degree (EN61010-1) 2 Equipment Class (IEC 536) II Page 16 IIG-060902