arxiv: v1 [cond-mat.supr-con] 29 Dec 2013

Similar documents
Dispersive Readout, Rabi- and Ramsey-Measurements for Superconducting Qubits

arxiv: v2 [cond-mat.mes-hall] 19 Oct 2010

Synthesizing arbitrary photon states in a superconducting resonator

Quantum Optics with Electrical Circuits: Circuit QED

Doing Atomic Physics with Electrical Circuits: Strong Coupling Cavity QED

arxiv: v3 [cond-mat.mes-hall] 25 Feb 2011

Quantum computation and quantum optics with circuit QED

Circuit Quantum Electrodynamics. Mark David Jenkins Martes cúantico, February 25th, 2014

arxiv: v1 [cond-mat.supr-con] 5 May 2015

Supplementary Information for Controlled catch and release of microwave photon states

State tomography of capacitively shunted phase qubits with high fidelity. Abstract

Circuit Quantum Electrodynamics

Dynamical Casimir effect in superconducting circuits

Wirebond crosstalk and cavity modes in large chip mounts for superconducting qubits

Distributing Quantum Information with Microwave Resonators in Circuit QED

R. McDermott Publications

Microwave Photon Counter Based on Josephson Junctions

Single-shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator

Cavity Quantum Electrodynamics with Superconducting Circuits

Superconducting qubits on silicon substrates for quantum device integration

An architecture for integrating planar and 3D cqed devices

Low-loss superconducting resonant circuits using vacuum-gap-based microwave components

QIC 890/891, Module 4: Microwave Parametric Amplification in Superconducting Qubit Readout experiments

arxiv: v1 [quant-ph] 22 Sep 2016

Fast, high-fidelity readout of multiple qubits

arxiv: v1 [quant-ph] 31 May 2010

arxiv: v1 [quant-ph] 8 Apr 2013

Quantum Optics with Electrical Circuits: Strong Coupling Cavity QED

Concentric transmon qubit featuring fast tunability and an anisotropic magnetic dipole moment

Controlling the Interaction of Light and Matter...

Entanglement Control of Superconducting Qubit Single Photon System

Multiplexing Superconducting Qubit Circuit for Single Microwave Photon Generation

arxiv: v2 [quant-ph] 8 May 2018

arxiv:cond-mat/ v1 [cond-mat.mes-hall] 27 Feb 2007

arxiv: v1 [cond-mat.supr-con] 14 Aug 2012

Exploring parasitic Material Defects with superconducting Qubits

Engineering the quantum probing atoms with light & light with atoms in a transmon circuit QED system

Metastable states in an RF driven Josephson oscillator

INTRODUCTION TO SUPERCONDUCTING QUBITS AND QUANTUM EXPERIENCE: A 5-QUBIT QUANTUM PROCESSOR IN THE CLOUD

Entangled Macroscopic Quantum States in Two Superconducting Qubits

Superconducting Qubits Lecture 4

SUPPLEMENTARY INFORMATION

Superconducting Qubits Coupling Superconducting Qubits Via a Cavity Bus

Circuit quantum electrodynamics : beyond the linear dispersive regime

Condensed Matter Without Matter Quantum Simulation with Photons

arxiv: v1 [quant-ph] 20 Mar 2017

Quantum simulation scheme of two-dimensional xy-model Hamiltonian with controllable coupling

Microwave Photon Counter Based on Josephson Junctions

Driving Qubit Transitions in J-C Hamiltonian

Robert McDermott. Department of Physics Tel: (608) University of Wisconsin-Madison Fax: (608)

Copper waveguide cavities with reduced surface loss for coupling to superconducting qubits

Josephson phase qubit circuit for the evaluation of advanced tunnel barrier materials *

Photon shot noise dephasing in the strong-dispersive limit of circuit QED

Φ / Resonant frequency (GHz) exp. theory Supplementary Figure 2: Resonant frequency ω PO

SUPPLEMENTARY INFORMATION

Superconducting Resonators and Their Applications in Quantum Engineering

Violation of Bell s inequality in Josephson phase qubits

Circuit QED with electrons on helium:

Cavity Quantum Electrodynamics (QED): Coupling a Harmonic Oscillator to a Qubit

Tunable Resonators for Quantum Circuits

(DARPA) QUANTUM-LIMITED MEASUREMENT AS A TOOL FOR ENTANGLEMENT IN SUPERCONDUCTING CIRCUITS

Electrical Quantum Engineering with Superconducting Circuits

USA 2) Department of Materials, University of California, Santa Barbara, California 93106, USA 3) Google Inc., Santa Barbara, California 93117, USA

Robustness of error-suppressing entangling gates in cavity-coupled transmon qubits

Synthesising arbitrary quantum states in a superconducting resonator

Single Microwave-Photon Detector based on Superconducting Quantum Circuits

Superconducting Qubits

Synthesizing Arbitrary Photon States in a Superconducting Resonator John Martinis UC Santa Barbara

Quantum optics and quantum information processing with superconducting circuits

Introduction to Circuit QED

10.5 Circuit quantum electrodynamics

Remote entanglement of transmon qubits

Supplementary material for Persistent control of a superconducting qubit by stroboscopic measurement feedback

arxiv: v1 [cond-mat.supr-con] 23 Sep 2011

Simple Scheme for Realizing the General Conditional Phase Shift Gate and a Simulation of Quantum Fourier Transform in Circuit QED

Superconducting quantum circuit research -building blocks for quantum matter- status update from the Karlsruhe lab

From SQUID to Qubit Flux 1/f Noise: The Saga Continues

Cavity quantum electrodynamics for superconducting electrical circuits: An architecture for quantum computation

arxiv: v1 [quant-ph] 1 Dec 2017

arxiv: v1 [quant-ph] 2 Mar 2018

Hybrid Quantum Circuit with a Superconducting Qubit coupled to a Spin Ensemble

Coplanar waveguide resonators for circuit quantum electrodynamics

Landau-Zener-Stückelberg-Majorana interference in a 3D transmon driven by a chirped microwave. Abstract

Supplementary information for Quantum delayed-choice experiment with a beam splitter in a quantum superposition

arxiv: v1 [quant-ph] 15 Oct 2015

Quantum non-demolition measurement of a superconducting two-level system

arxiv: v1 [quant-ph] 19 Oct 2016

Coherent Coupling between 4300 Superconducting Flux Qubits and a Microwave Resonator

Measuring the decoherence of a quantronium qubit with the cavity bifurcation amplifier

2015 AMO Summer School. Quantum Optics with Propagating Microwaves in Superconducting Circuits I. Io-Chun, Hoi

arxiv: v1 [quant-ph] 14 Jul 2009

Violation of Bell s inequality in Josephson phase qubits

CIRCUIT QUANTUM ELECTRODYNAMICS WITH ELECTRONS ON HELIUM

10.5 Circuit quantum electrodynamics

Supercondcting Qubits

Amplification, entanglement and storage of microwave radiation using superconducting circuits

Qubit-photon interactions in a cavity: Measurement-induced dephasing and number splitting

arxiv: v1 [quant-ph] 6 Oct 2011

Controlled-NOT logic with nonresonant Josephson phase qubits

Quantum-information processing with circuit quantum electrodynamics

Transcription:

High Fidelity Qubit Readout with the Superconducting Low-Inductance Undulatory Galvanometer Microwave Amplifier D. Hover, S. Zhu, T. Thorbeck, G.J. Ribeill, and R. McDermott Department of Physics, University of Wisconsin, Madison, Wisconsin 53706, USA arxiv:1312.7579v1 [cond-mat.supr-con] 29 Dec 2013 D. Sank, J. Kelly, R. Barends, and John M. Martinis Department of Physics, University of California, Santa Barbara, California 93106, USA (Dated: November 5, 2018) Abstract We describe the high fidelity dispersive measurement of a superconducting qubit using a microwave amplifier based on the Superconducting Low-inductance Undulatory Galvanometer (SLUG). The SLUG preamplifier achieves gain of 19 db and yields a signal-to-noise ratio improvement of 9 db over a state-of-the-art HEMT amplifier. We demonstrate a separation fidelity of 99% at 700 ns compared to 59% with the HEMT alone. The SLUG displays a large dynamic range, with an input saturation power corresponding to 700 photons in the readout cavity. PACS numbers: 85.25.Am, 85.25.Dq, 84.30.Le, 84.40.Lj 1

Over the past decade, circuit quantum electrodynamics (cqed) has emerged as a powerful paradigm for scalable quantum information processing in the solid state [1 3]. Here a superconducting qubit plays the role of an artificial atom, and a thin-film coplanar waveguide or bulk cavity resonator is used to realize a bosonic mode with strong coupling to the atom [4 9]. In the limit where the qubit is far detuned from the cavity resonance, it is possible to perform a quantum nondemolition measurement of the qubit by monitoring the microwave transmission across the cavity at a frequency close to the cavity resonance [1]. In order to maximize measurement fidelity, it is necessary to reduce the added noise of the measurement system to the greatest extent possible [10]. For conventional HEMT-based readout at frequencies in the range from 6-7 GHz, one has an added system noise around twenty quanta, n a 20, and for typical parameters one finds single-shot qubit measurement fidelity of order 50% in 500 ns. For fast, high fidelity, single-shot readout in cqed, it is necessary to read out the cavity with an amplifier whose noise performance approaches the standard quantum limit n a = 1/2, the minimum noise achievable by a phase-insensitive linear amplifier [11]. There has been significant recent progress in the use of Josephson parametric amplifiers (JPAs) for qubit readout. Specific milestones include observation of quantum jumps in a transmon qubit [12], heralded state preparation to eliminate initialization errors [13, 14], and stabilization of qubit Rabi oscillations using quantum feedback [15]. While JPAs achieve noise performance that approaches the standard quantum limit (or even surpasses it in the case of operation in phase-sensitive mode), state-of-the-art amplifiers still suffer from small instantaneous bandwidth and low dynamic range, with input saturation power of order -120 dbm [16]. These features make it challenging to multiplex in a multi-qubit architecture, i.e., to read out multiple cavity tones simultaneously with a single JPA. Moreover, the JPA requires a separate strong microwave pump tone, from which the qubit must be protected by several stages of cryogenic isolation. In this Letter, we describe an alternative approach to qubit readout based on amplification with a Superconducting Low-inductance Undulatory Galvanometer (SLUG), a variant of the dc Superconducting QUantum Interference Device (dc SQUID) [17, 18]. SQUID based amplifiers have demonstrated noise performance within a factor of two of the standard quantum limit at 600 MHz [19] and large gain-bandwidth products at GHz frequencies [20]. Specific advantages of the SLUG geometry include a large flux-to-voltage transfer function, a 2

(a) (b) SLUG Flux Read Out Qubit Drive XMon Bias To HEMT SLUG I/V 15 µm 12 GHz CPF -40-20 CPF CPF (c) 20 Gain (db) 18 16 14 12 10 54 55 56 57 Flux Bias (μa) 58 10 9 8 7 6 5 SNR Improvement (db) Xmon Cryoperm & Iso. IR absorber Iso CR CR SLUG CR FIG. 1: (a) Micrograph of SLUG gain element. The 2 µm 2 junctions are separated by a 15 µm long SLUG body with trace width 1 µm. The input signal is coupled to the SLUG via a lumped element LC matching network (not shown). (b) Block diagram of the experiment. All components shown here are mounted at the mixing chamber plate of the DR. Here CPF stands for copper powder filter, Iso. stands for cryogenic isolator, and CR stands for cryogenic coaxial relay. (c) Gain (blue) and SNR improvement (red) versus flux bias of the SLUG amplifier close to the qubit readout frequency of 6.614 GHz. The device was biased at a current of 33 µa. relatively large real part of the input impedance of order a fraction of an ohm, and a compact device geometry that is free of parasitic stray reactances. While the noise of a SLUG amplifier will never equal that of an optimized JPA, added noise of order one quantum is achievable at frequencies approaching 10 GHz. Moreover, an optimized SLUG has the possibility of achieving an instantaneous bandwidth approaching 1 GHz with saturation powers of -90 dbm [17], opening the door to multiplexed single-shot readout in circuit QED. A micrograph of the SLUG element is shown in Fig. 1(a). The SLUG amplifier was realized in a six-layer process using optical projection lithography: three superconducting Nb layers with thickness 100 nm define the circuit groundplane and the two branches of the SLUG loop; two SiO 2 layers of the same thickness separate the superconducting traces; and a Pd layer with thickness 30 nm was used to realize the 8 Ω resistors shunting each junction. The Nb/Al-AlO x -Al/Nb Josephson junctions were formed in 2 µm 2 vias etched in the upper SiO 2 layer. The critical current per junction is I 0 = 20 µa, corresponding to a critical current density of 1 ka/cm 2. The mutual inductance between the input signal and the 3

SLUG loop is M = 6.7 ph, and the peak-to-peak voltage modulation of the device is around 130 µv. The input matching network is a single-pole lumped element LC section with a designed characteristic impedance of 2 Ω; the component values were chosen to maximize the gain-bandwidth product at an operating frequency of 6.6 GHz. The 2x2 mm 2 die was packaged in a brass box and clamped onto the cold stage of a dilution refrigerator (DR). The Xmon qubit has been described in detail elsewhere [21]. The device is capacitively coupled to a quarter-wave coplanar waveguide resonator with a measured coupling constant g/2π = 30 MHz, a resonance frequency ω 0 /2π near 6.6 GHz, and a cavity decay rate κ/2π = 1.14 MHz. The qubit frequency ω 10 /2π is close to 6 GHz, with an anharmonicity of 230 MHz and a ratio E J /E C 95 [22]. The qubit was mounted in a superconducting aluminum box inside a cryoperm shield. The use of nonmagnetic connectors and cabling in the vicinity of the sample ensured that the device was cooled in a low magnetic field environment, and multiple stages of infrared shielding suppressed quasiparticle generation from stray light [23]. We measured a qubit energy relaxation time T 1 = 10.4 µs both with and without the SLUG in the amplification chain. A block diagram of the experiment is shown in Fig. 1(b). Three cryogenic coaxial relays at the mixing chamber of the DR allowed separate characterization of the qubit and the SLUG amplifier and enabled in situ calibration of SLUG gain and signal-to-noise ratio (SNR) enhancement. The SLUG flux (current) bias was heavily filtered at both 4.2 K and 40 mk and combined with the microwave input (output) of the amplifier using a commercial bias-t. The output signal passed through a cryogenic isolator before being amplified by a low-noise HEMT at 4.2 K; a second isolator between the qubit and SLUG suppressed microwave emission from the SLUG input back toward the qubit. The measurement chain without the SLUG amplifier had a system noise of around twenty quanta, n a 20, at 6.6 GHz. In Fig. 1(c) we plot the measured gain and SNR improvement versus SLUG flux bias at a frequency slightly detuned from the qubit measurement frequency. At optimal bias, the SLUG achieved 19 db gain while improving the SNR of the amplification chain by 9 db. The instantaneous bandwidth of this SLUG device was around 50 MHz at the qubit measurement frequency and could be dynamically tuned from 6.45 to 6.65 GHz. The average photon occupation of the cavity was calibrated with a measurement of the ac Stark shift of the qubit frequency [3, 24]. Here the cavity was excited by the readout tone for a duration much longer than its characteristic time τ c = 2π/κ = 880 ns, ensuring 4

700 (a) (b) 2 I Quadrature 350 S S 1.5 1 0.5 0 0 0 400 800 0 400 800 Q Quadrature Q Quadrature 1.0 (c) (d) 300 S 0.8 Bin Counts 200 100 0 Integration Axis Integrated Signal 0.6 0.4 0.2 0 Integration Axis FIG. 2: Heterodyne signal distribution measured with the SLUG for qubit preparation in the 0 (a) and 1 (b) states. The measurement time was 600 ns and the readout power corresponds to a steady state photon occupation n = 108 in the readout resonator. The false color scale is the log of the bin counts. The optimal measurement axis is indicated by the black line, and S is the distance between the centers of the two distributions in quadrature space. Projected heterodyne histogram (c) and integrated signal (d) for qubit preparation in the 0 (blue) and 1 (red) state. The dashed lines in (c) are fits to a double Gaussian, while σ 0 and σ 1 are the standard deviations of the qubit state distributions. The integrated signals in (d) are normalized to the total number of qubit preparations, and the measurement fidelity (green) is the difference between the two integrated signals. that the dynamics of the cavity had reached their steady state before the qubit frequency was probed spectroscopically. As a result, the average photon occupation n reported in this Letter overestimates the actual occupation for measurement times on the order of τ c. To measure the qubit, we monitored the microwave transmission across the cavity at a frequency of 6.614 GHz, corresponding to the dressed cavity resonance observed when the qubit is in the 0 state. For each measurement shot, the heterodyne voltage was integrated over time and the in-phase (I) and quadrature (Q) components of the signal were recorded. In this measurement scheme, multiple preparations of the 0 or 1 states yield two different Gaussian distributions in IQ space. In Figs. 2(a-b) we plot the heterodyne signal distributions for nominal preparation of the 0 and 1 states, respectively. In each of these plots, we observe one main Gaussian component corresponding to the desired state, with a small 5

1.0 (a) 0.8 Fidelity 0.6 0.4 0.2 11 (b) Heterodyne SNR (db) 10 9 8 7 6 0.3 0.5 0.7 0.9 1.1 1.3 1.5 Measurement Time (μs) 10 2 10 3 Cavity Photon Population FIG. 3: (a) Qubit measurement fidelity obtained with (blue) and without (red) SLUG preamplification. The cavity drive corresponds to a steady state photon occupation n = 108. The solid (dashed) lines are the raw measurement fidelities (separation fidelities); see main text. (b) Heterodyne SNR improvement with the SLUG versus cavity photon occupation for measurement times of 600 ns (blue) and 1.2 µs (red). satellite component corresponding to a spurious admixture of the other qubit state. The separation of the heterodyne distributions corresponding to the qubit basis states is determined by the amplitude and duration of the microwave drive and by the state-dependent cavity pull, while the widths of the distributions reflect the overall noise of the measurement chain. The line joining the centers of the 0 and 1 state distributions defines an optimal measurement axis for heterodyne detection. In Fig. 2(c) we plot the heterodyne histograms projected against this axis for qubit preparation in the 0 (blue) and 1 (red) states; here 0 state preparation was accomplished by waiting many qubit T 1 times prior to measurement, while the 1 state was prepared from the 0 state with a calibrated π pulse. In these experiments, the readout was driven with an amplitude corresponding to a steady-state n = 108 n crit, where the critical photon number n crit 2 /4g 2 roughly marks the breakdown of the dispersive approximation to the Jaynes-Cummings Hamiltonian [1, 25]. We evaluate measurement fidelity by integrating the two histograms along the optimal measurement axis and taking the difference, as shown in Fig. 2(d). Measurement fidelities for SLUG (blue) and HEMT (red) are plotted as solid traces in Fig. 3(a) for a range of measurement times τ m, where τ m is the duration of the cavity excitation pulse. The measurement fidelity plateaus at 0.7 for τ m = 700 ns when using the SLUG amplifier; this represents a significant improvement compared to the measurement fidelity of 0.3 with the 6

HEMT alone for the same measurement time. Several factors contribute to measurement infidelity: (1) state preparation errors, (2) relaxation errors, (3) measurement-induced transitions, and (4) measurement errors. Errors (1)-(3) are the result of a transfer of weight from one of the two heterodyne state distributions to the other, while measurement errors are the result of insufficient separation of the distributions in quadrature space due to excessive noise of the measurement system. For this reason, it is possible to separate out preparation/relaxation/induced transition errors from measurement errors by fitting two Gaussian components to the heterodyne data. For example, preparation errors lead to a large spurious second Gaussian component in the quadrature histograms. To focus on the effect of the measurement chain alone, one can ignore the spurious second component and rescale the desired component appropriately in order to evaluate a separation fidelity, a figure of merit that is independent of qubit preparation and relaxation errors. In our experiments, measurement errors are dominant at short times (under 400 ns), while for longer times we find that state preparation errors dominate. Indeed, we observe a large equilibrium 1 state population around 12% when we are nominally initializing in 0 ; we believe that this is due to insufficient filtering of IR radiation. This preparation error, which is present with and without the SLUG in the amplification chain, contributes twice to measurement infidelity, degrading fidelity of both the 0 state and the 1 state, which is prepared from the corrupted 0 state. Thus, our excess 1 state population of 12% immediately limits measurement fidelity to 76%. From the measured T 1 time of 10.4 µs we expect an infidelity of 2.5% in 500 ns. We display the separation fidelities of qubit measurements with and without the SLUG preamplifier as dashed traces in Fig. 3(a). We find a separation fidelity of 0.99 with the SLUG compared to 0.59 without the SLUG for a measurement time of 700 ns. This improvement is due entirely to the significant reduction in added noise of the measurement chain at the qubit measurement frequency. We remark that the measurement time is limited by the rate at which photons leak out of the readout cavity, which in the current experiment is relatively weakly coupled to the measurement apparatus. We anticipate that the incorporation of an appropriate Purcell filter at the output of the cavity will enable strong coupling at the cavity output without introducing additional dissipation at the qubit frequency [26], so that measurement fidelities of order 99% should be attainable in times of order 100 ns. One of the advantages of the SLUG amplifier compared to the JPA is the significantly 7

higher saturation power. In Figure 3(b), we plot the heterodyne SNR improvement as a function of number of photons in the resonator for measurement times of 600 ns and 1.2 µs; here, we define heterodyne SNR as the ratio S/(σ 0 + σ 1 ) of the separation S of the centers of the 0 and 1 histograms to the sum of their standard deviations. Here we extrapolated n from low power by assuming a linear relationship between the power applied to the chip and the cavity occupation. The 1 db compression point occurs at n between 700 and 1000 photons in the cavity, an average cavity photon occupation number that exceeds the saturation power of a typical JPA by almost an order of magnitude [27]. In conclusion, we have described high fidelity single-shot measurements of an Xmon qubit using an ultralow-noise SLUG microwave amplifier. The SLUG improves the SNR of the measurement chain by around 9 db, yielding an improvement in single-shot separation fidelity from 0.59 to 0.99 in 700 ns. The measurement time is limited by the rate at which photons leak out of the readout cavity; with the addition of an appropriate Purcell filter, we anticipate that similar fidelities could be reached in measurement times of order 100 ns. With the potential for large instantaneous bandwidth and a saturation power that is more than an order of magnitude greater than that of an optimized JPA, the SLUG is well suited to frequency-multiplexed dispersive readout of multiple superconducting qubits, for example in a scalable surface code circuit [28]. This research was funded by the Office of the Director of National Intelligence (ODNI), Intelligence Advanced Research Projects Activity (IARPA), through the Army Research Office Grants W911NF-10-1-0334 and W911NF-11-1-0029. All statements of fact, opinion, or conclusions contained herein are those of the authors and should not be construed as representing the official views or policies of IARPA, the ODNI, or the U.S. Government. [1] A. Blais, R. S. Huang, A. Wallraff, S. M. Girvin, and R. J. Schoelkopf, Phys. Rev. A 69, 062320 (2004). [2] A. Wallraff, D.I. Schuster, A. Blais, L. Frunzio, R.S. Huang, J. Majer, S. Kumar, S.M. Girvin and R.J. Schoelkopf, Nature 431, 162 (2004). [3] D.I. Schuster and A. Wallraff and A. Blais and L. Frunzio and R.S. Huang and J. Majer and S.M. Girvin, and R.J. Schoelkopf, Phys. Rev. Lett. 94, 123602 (2005). 8

[4] J. Majer, J.M. Chow, J.M. Gambetta, J. Koch, B.R. Johnson, J.A. Schreier, L. Frunzio, D.I. Schuster, A.A. Houck, A. Wallraff, A. Blais, M.H. Devoret, S.M. Girvin, and R.J. Schoelkopf, Nature 449, 443 (2007). [5] M. Hofheinz, E. M. Weig, M. Ansmann, R. C. Bialczak, E. Lucero, M. Neeley, A. D. O Connell, H. Wang, J. M. Martinis, and A. N. Cleland, Nature 454, 310 (2008). [6] M. Hofheinz, H. Wang, M. Ansmann, R.C. Bialczak, E. Lucero, M. Neeley, A.D. O Connell, D. Sank, J. Wenner, J.M. Martinis, and A.N. Cleland, Nature 459, 546 (2009). [7] L. DiCarlo, J.M. Chow, J.M. Gambetta, L.S. Bishop, B.R. Johnson, D.I. Schuster, J. Majer, A. Blais, L. Frunzio, S.M. Girvin, and R.J. Schoelkopf, Naure 460, 240 (2009). [8] L. DiCarlo, M.D. Reed, L. Sun, B.R. Johnson, J.M. Chow, J.M. Gambetta, L. Frunzio, S.M. Girvin, M.H. Devoret, and R.J. Schoelkopf, Nature 467, 574 (2010). [9] J.M. Chow, J.M. Gambetta, A.D. Córcoles, S.T. Merkel, J.A. Smolin, C. Rigetti, S. Poletto, G. A. Keefe, M.B. Rothwell, J.R. Rozen, M.B. Ketchen, and M. Steffen, Phys. Rev. Lett. 109, 060501 (2012). [10] J.M. Gambetta, A. Blais, M. Boissonneault, A.A. Houck, D.I. Schuster, and S.M. Girvin, Phys. Rev. A 77, 012112 (2008). [11] C.M. Caves, Phys. Rev. D 26, 1817 (1982). [12] R. Vijay, D. H. Slichter, and I. Siddiqi, Phys. Rev. Lett. 106, 110502 (2011). [13] J. E. Johnson, C. Macklin, D. H. Slichter, R. Vijay, E. B. Weingarten, J. Clarke, and I. Siddiqi, Phys. Rev. Lett. 109, 050506 (2012). [14] D. Ristè, J. G. van Leeuwen, H.-S. Ku, K. W. Lehnert, and L. DiCarlo, Phys. Rev. Lett. 109, 050507 (2012). [15] R. Vijay, C. Macklin, D. H. Slichter, S. J. Weber, K. W. Murch, R. Naik, A. N. Korotkov, and I. Siddiqi, Nature 490, 7780 (2012). [16] J. Y. Mutus, T. C. White, E. Jeffrey, D. Sank, R. Barends, J. Bochmann, Yu Chen, Z. Chen, B. Chiaro, A. Dunsworth, J. Kelly, A. Megrant, C. Neill, P. J. J. OMalley, P. Roushan, A. Vainsencher, J. Wenner, I. Siddiqi, R. Vijay, A. N. Cleland, and J. M. Martinis, Appl. Phys. Lett. 103, 122602 (2013). [17] G. J. Ribeill, D. Hover, Y. F. Chen, S. Zhu, and R. McDermott, J. Appl. Phys. 110, 103901 (2011). [18] D. Hover, Y. F. Chen, G. J. Ribeill, S. Zhu, S. Sendelbach, and R. McDermott, Appl. Phys. 9

Lett. 100, 063503 (2012). [19] M. Mück, J. B. Kycia, and J. Clarke, Appl. Phys. Lett. 78, 967 (2001). [20] L. Spietz, K. Irwin, and J. Aumentado, Appl. Phys. Lett. 95, 092505 (2009). [21] R. Barends, J. Kelly, A. Megrant, D. Sank, E. Jeffrey, Y. Chen, Y. Yin, B. Chiaro, J. Mutus, C. Neill, P. O Malley, P. Roushan, J. Wenner, T. C. White, A. N. Cleland, and J. M. Martinis, Phys. Rev. Lett. 111, 080502 (2013). [22] J. Koch, T. M. Yu, J. Gambetta, A. A. Houck, D. I. Schuster, J. Majer,1 A. Blais, M. H. Devoret, S. M. Girvin, and R. J. Schoelkopf, Phys. Rev. A 76, 042319 (2007). [23] R. Barends, J. Wenner, M. Lenander, Y. Chen, R. C. Bialczak, J. Kelly, E. Lucero, P. OMalley, M. Mariantoni, D. Sank, H. Wang, T. C. White, Y. Yin, J. Zhao, A. N. Cleland, J. M. Martinis, and J. J. A. Baselmans, Appl. Phys. Lett. 99, 113507 (2011). [24] M. Boissonneault, J. M. Gambetta, and Alexandre Blais,Phys. Rev. Lett. 105, 100504 (2010). [25] J. Gambetta, W. A. Braff, A. Wallraff, S. M. Girvin, and R. J. Schoelkopf, Phys. Rev. A 76, 012325 (2007). [26] M. D. Reed, B. R. Johnson, A. A. Houck, L. DiCarlo, J. M. Chow, D. I. Schuster, L. Frunzio, and R. J. Schoelkopf, Appl. Phys. Lett. 96, 203110 (2010). [27] Z. R. Lin, K. Inomata, W. D. Oliver, K. Koshino, Y. Nakamura, J. S. Tsai, and T. Yamamoto, Appl. Phys. Lett. 103, 132602 (2013). [28] A. G. Fowler, M. Mariantoni, J. M. Martinis, and A. N. Cleland, Phys. Rev. A 86, 032324 (2012). 10