Monte Carlo Simulations of Synchrotron Radiation and Vacuum Performance of the MAX IV Light Sources

Similar documents
Vacuum System of Synchrotron radiation sources

A SIMULATION STUDY OF THE ELECTRON CLOUD IN THE EXPERIMENTAL REGIONS OF LHC

Experience from the LEP Vacuum System

Magnetic and Electric Field Effects on the Photoelectron Emission from Prototype LHC Beam Screen Material

Beam induced desorption

seminar: MAX IV laboratory vacuum systems

Results on a-c tubes subjected to synchrotron irradiation

Vacuum and mechanical design of ILC DR

Non-Evaporable Getters

1. SYNCHROTRON RADIATION-INDUCED DESORPTION

Study of Distributed Ion-Pumps in CESR 1

EXPERIMENTAL INVESTIGATIONS OF THE ELECTRON CLOUD KEY PARAMETERS

Accelerator Vacuum Technology Challenges for Next-Generation Synchrotron-Light Sources

Radiation Protection Considerations for the Cryogenic In-Vacuum Undulator of the EMIL Project at BESSY

Low Emittance Storage Ring for Light Source. Sukho Kongtawong PHY 554 Fall 2016

Fundamentals of Accelerators

Vacuum Science and Technology in Accelerators

Vacuum at the ESRF. current activities that benefit from simulation models

Beam-induced heat loads on the beam screens of the inner triplets for the HL-LHC

Vacuum Technology for Particle Accelerators

Simulations of synchrotron-radiation-induced electron production in the CESR vacuum chamber wall

1.1 Electron-Cloud Effects in the LHC

ANALYSIS OF SYNCHROTRON RADIATION USING SYNRAD3D AND PLANS TO CREATE A PHOTOEMISSION MODEL

Shielding Design for the Imaging and Medical Beamline at the Australian Synchrotron

UHV - Technology. Oswald Gröbner

NEXTorr HV 100 HIGHLIGHTS

Vacuum for Accelerators

Experimental Results of a LHC Type Cryogenic Vacuum System Subjected to an Electron Cloud

The Vacuum Case for KATRIN

Shielding calculations for the design of new Beamlines at ALBA Synchrotron

A PHOTON-STOP FOR THE VLHC-2 ENGINEERING DESIGN PART 1

Optimized Annular Triode Ion Pump for Experimental Areas in the LHC

THE LARGE HADRON COLLIDER VACUUM SYSTEM

arxiv: v1 [physics.acc-ph] 1 Apr 2015

Why are particle accelerators so inefficient?

Theory English (Official)

Abstract. 1. Introduction

Monte Carlo Simulations of Beam Losses in the Test Beam Line of CTF3

Occupational Radiation Protection at Accelerator Facilities: Challenges

Repetition: Physical Deposition Processes

Introduction to Synchrotron Light Sources

2.6 Electron transport lines

Vacuum I. G. Franchetti CAS - Bilbao. 30/5/2011 G. Franchetti 1

6.5 Optical-Coating-Deposition Technologies

Optimization of the SIS100 Lattice and a Dedicated Collimation System for Ionisation Losses

The CNGS neutrino beam

OVERVIEW OF THE LHEC DESIGN STUDY AT CERN

Beam induced heat loads on the beam-screens of the twin-bore magnets in the IRs of the HL-LHC

Simulation Studies for a Polarimeter at the International Linear Collider (ILC)

A Vacuum point of view

Radiation measurements around ESRF beamlines

λ = 5 10 p (i.e. 5 cm at 10 3 Torr, or ( )

First propositions of a lattice for the future upgrade of SOLEIL. A. Nadji On behalf of the Accelerators and Engineering Division

The LHC: the energy, cooling, and operation. Susmita Jyotishmati

Measurements and simulations of electron-cloudinduced tune shifts and emittance growth at CESRTA

Advanced Storage Photon Ring Source Upgrade Project:

Transverse dynamics Selected topics. Erik Adli, University of Oslo, August 2016, v2.21

( KS A ) (1) , vapour, vapor (USA) , saturation vapour pressure. , standard reference conditions for gases. , degree of saturation

Synchrotron Methods in Nanomaterials Research

Why do we accelerate particles?

Electron Cloud Studies at the Cornell Electron Storage Ring. Matt Lawson

arxiv: v1 [physics.ins-det] 9 Apr 2018

Introduction to Accelerator Physics Part 1

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

The Very Large Hadron Collider Beam Collimation System

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. II - Synchrotron Radiation - Malcolm J. Cooper

ThomX Machine Advisory Committee. (LAL Orsay, March ) Ring Beam Dynamics

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

CapaciTorr HV Pumps. making innovation happen,together

RF systems for the MAX IV rings

The photoneutron yield predictions by PICA and comparison with the measurements

Comparison of FLUKA and STAC8 for shielding calculations of the hard X-ray line of the LCLS

Upstream Polarimetry with 4-Magnet Chicane

Simulation of the ILC Collimation System using BDSIM, MARS15 and STRUCT

Introduction to Accelerator Physics Part 1

ION Pumps for UHV Systems, Synchrotrons & Particle Accelerators. Mauro Audi, Academic, Government & Research Marketing Manager

Case study: Energy deposition in superconducting magnets in IR7

Research with Synchrotron Radiation. Part I

Tutorial on Gas Flow, Conductance, Pressure Profiles R. Kersevan, TE/VSC-VSM CERN, Geneva

Secondary Ion Mass Spectrometry (SIMS)

ACCELERATOR MASS SPECTROMETRY AT THE LUND PELLETRON ACCELERATOR

BALKAN PHYSICS LETTERS Bogazici University Press 15 November 2016 BPL, 24, , pp , (2016)

(4) vacuum pressure & gas desorption in the IRs ( A.

How Does It All Work? A Summary of the IDEAS Beamline at the Canadian Light Source

Physics 736. Experimental Methods in Nuclear-, Particle-, and Astrophysics. - Accelerator Techniques: Introduction and History -

Appendix A2. Particle Accelerators and Detectors The Large Hadron Collider (LHC) in Geneva, Switzerland on the Border of France.

Higgs Factory Magnet Protection and Machine-Detector Interface

MODELING OF AN ECR SOURCE FOR MATERIALS PROCESSING USING A TWO DIMENSIONAL HYBRID PLASMA EQUIPMENT MODEL. Ron L. Kinder and Mark J.

ACCELERATOR VACUUM TECHNOLOGY CHALLENGES FOR NEXT- GENERATION SYNCHROTRON-LIGHT SOURCES

Physics 610. Adv Particle Physics. April 7, 2014

Beam Scattering Effects - Simulation Tools Developed at The APS. A. Xiao and M. Borland Mini-workshop on Dynamic Aperture Issues of USR Nov.

DESIREE A Double Electrostatic Storage Ring for Merged-Beam Experiments

Accelerator Design and Construction Progress of TPS Project

Vacuum Science and Technology in Accelerators

Very Large Hadron Collider - phase 2 Optimization of the beam screen cooling & Impact of the photon stop on the cryogenic system

The TESLA Dogbone Damping Ring

Introduction to Accelerator Physics

Vacuum. Residual pressure can thwart the best cryogenic design. Each gas molecule collision carries ~kt from the hot exterior to the cold interior.

ASPECTS OF MACHINE INDUCED BACKGROUND IN THE LHC EXPERIMENTS

PARTICLE BEAMS, TOOLS FOR MODERN SCIENCE AND MEDICINE Hans-H. Braun, CERN

Transcription:

CERN-ACC-2014-0259 marton.ady@cern.ch Monte Carlo Simulations of Synchrotron Radiation and Vacuum Performance of the MAX IV Light Sources M. Ady, R. Kersevan CERN, Geneva, Switzerland M. Grabski MAX IV, Lund, Sweden Keywords: Monte Carlo, MAX IV, NEG CERN-ACC-2014-0259 07/11/2014 Abstract In the 3 GeV ring of MAX IV light source in Lund, Sweden, the intense synchrotron radiation (SR) distributed along the ring generates important thermal and vacuum effects. By means of a Monte Carlo simulation package, which is currently developed at CERN, both thermal and vacuum effects are quantitatively analysed, in particular near the crotch absorbers and the surrounding NEG-coated vacuum chambers. Using SynRad+, the beam trajectory of the upstream bending magnet is calculated; SR photons are generated and traced through the geometry until their absorption. This allows an analysis of the incident power density on the absorber, and to calculate the photon induced outgassing. The results are imported to Molflow+, a Monte Carlo vacuum simulator that works in the molecular flow regime, and the pressure in the vacuum system and the saturation length of the NEG coating are determined using iterations. Presented at: IPAC14, 15-20 June, Dresden, Germany Geneva, Switzerland October, 2014

MONTE CARLO SIMULATIONS OF SYNCHROTON RADIATION AND VACUUM PERFORMANCE OF THE MAX IV LIGHT SOURCE M. Ady, R. Kersevan (CERN, Geneva, Switzerland), M. Grabski (MAX IV, Lund, Sweden) Abstract In the 3 GeV ring of MAX IV light source in Lund, Sweden, the intense synchrotron radiation (SR) distributed along the ring generates important thermal and vacuum effects. By means of a Monte Carlo simulation package, which is currently developed at CERN, both thermal and vacuum effects are quantitatively analysed, in particular near the crotch absorbers and the surrounding NEG-coated vacuum chambers. Using SynRad+, the beam trajectory of the upstream bending magnet is calculated; SR photons are generated and traced through the geometry until their absorption. This allows an analysis of the incident power density on the absorber, and to calculate the photon induced outgassing. The results are imported to Molflow+, a Monte Carlo vacuum simulator that works in the molecular flow regime, and the pressure in the vacuum system and the saturation length of the NEG coating are determined using iterations. INTRODUCTION MAX IV is a new synchrotron light source facility being constructed in Lund, Sweden. The facility comprises of a 3.4 GeV linac, 1.5 GeV and 3 GeV storage rings and a short pulse facility. The 3 GeV ring (528 m in circumference) will be an ultra-low emittance ring (bare lattice emittance of 0.33 nm rad) based on multi-bend achromat (MBA) magnet concept. Due to the compact magnet design and small magnet aperture of 25 mm, the majority of the vacuum chambers are designed as circular tubes of 22 mm inside diameter and 1 mm wall thickness. Their specific conductance is only 1.3 l m/s for N 2 at room temperature. To reduce pressure, all the conductance limited chambers are planned to be coated with non-evaporable getter (NEG) film of TiZrV. The coating is deposited by magnetron sputtering method that was developed at CERN and is used in other synchrotron light facilities around the world. Each of the 20 vacuum achromats of the 3 GeV ring is equipped with three sputter ion pumps and one crotch absorber in the place where the electron and photon beams split. The synchrotron radiation fan between the two beams impinges on the crotch absorber. To cope with large outgassing at that position, one of the ion pumps is located directly below the absorber. The upstream keyhole profiled structure and the downstream beam chamber are NEGcoated starting from 6 cm from the ion pump chamber. The wall of that pump chamber is also coated. In order to estimate the thermal load and to create detailed photodesorption maps on the vacuum chamber walls a recently improved Monte Carlo software package was used: Synrad+[1] simulates synchrotron radiation distribution from the upstream bending magnet and Molflow+[2] performs the pressure profile simulations inside the vacuum chamber. Figure 1: Top view of the vacuum chamber with the absorber One of the new features of the two programs is that the generated synchrotron radiation map in Synrad+ can be imported to Molflow+ and automatically converted to an outgassing map. This article describes the whole process which concludes in determining the pressure profile around the absorber. SYNCHROTRON RADIATION SIMULATION The first calculation step is determining the absorbed SR power and flux on the chamber wall, which serves as base to calculate the thermal load and the dynamic outgassing. To achieve this, a CAD model describing the region around the absorber is imported to SynRad+. It consists of 8595 facets, the majority of them describing the pumping ports next to the absorber. The dipole magnet (DIPm) 451 mm upstream of the modeled section has a 0.5 T average strength and 1.5 bending angle. In SynRad+, it is described as a magnetic region where the trajectory is calculated automatically from the beam energy, starting direction and the magnetic field. Upon launching the simulation, virtual test photons are generated with uniformly distributed starting locations along the calculated beam path. Once their energy and starting direction is assigned, they are launched towards the system, each representing a given physical photon flux and power. The ray-tracing algorithm finds collisions with the chamber wall, where depending on the incident angle and photon energy, a reflection probability is interpolated from material data [3]. It is used to decide if the virtual photon is absorbed or reflected. When reflection occurs, the reflection direction is perturbed by a simulated surface roughness. Photons are traced until absorption, when the algorithm reiterates by creating a new virtual photon.

This has been measured previously for several materials. In this paper measurements [4] for an oxygen free high conductivity copper chamber are used as it corresponds to the absorber s material. The desorption yield depends on the absorbed photon dose (it decreases as the surface is conditioned by SR). However, the measurement data cannot be used directly as the photon dose is published using linear flux density (photons/m), whereas SynRad+ calculates surface density (photons/cm 2 ). The difference can be explained by the fact that Groebner et al. have measured the photodesorption by SR impinging on a 3.6 m long vacuum chamber wall with 11 mrad grazing angle. In our case, however, SR is absorbed by a short, complex crotch absorber geometry where the surface flux density is more meaningful. Figure 2: the dipole magnet and SR radiation schematics To determine the power and flux distribution, 5 million test photons were generated, representing the real flux of 4.2 10 18 photons/sec and power of 700.7 W generated by the magnet at the nominal current of 500 ma. Figure 3: power density on the lower jaw of the absorber The absorber jaws receive 407 W of the SR power, with the highest power density of 6.1 W/mm 2, a value which is below the thermal limit for copper. A further 33 W is deposited on the outer wall of the downstream beam pipe, distributed on a meter-long distance thus causing negligible heating. The remaining power leaves the modeled region through the light and beam ports. As for the photon flux, 50% is absorbed by the crotch absorber, approximately 40% leaves the region through the beam and SR extraction ports, and the rest is absorbed at various locations, typically after multiple reflections. The highest SR flux density, corresponding to 6.8 10 17 photons/sec/cm 2 is also observed on the absorber s jaws. CONVERSION TO DYNAMIC OUTGASSING Once the absorbed photon flux is determined, to convert it to dynamic outgassing, the photodesorption yield, i.e. the number of gas molecules that are released per incoming photon must be known. Figure 4: the original experiment schematics from Fig.1. of [4] and its simulation in SynRad+ To be able to convert between the two dose types, the original experiment was recreated in Synrad+. The 10 15 photons/sec flux of the original experiment was divided by the 3.6 m incidence length to obtain the linear density. In SynRad+, the simulated flux density has an average of 4 10 12 photons/sec/cm 2 on the approx. 1 cm high, 3.6m long slice of the tube where the majority of the SR is absorbed. Comparing the two quantities, it was deduced that 70 photons/m linear dose of the published data [4] corresponds to 1 photon/cm 2 surface dose simulated by Synrad+ on the irradiated parts. Using this conversion factor, the desorption yield plots of the original article were digitized for the four most desorbed gases (CH 4, H 2, CO, CO 2) and exported in a format that can be used by Molflow+. VACUUM SIMULATIONS Since file formats of Synrad+ and Molflow+ are compatible, the previously saved SR simulation can be opened directly for vacuum simulations. All SR data (magnetic regions, flux, material roughness) is removed so the vacuum chamber s pure geometry remains, therefore before starting the simulation the gas desorption and the pumping have to be added. Four different vacuum simulations are performed one for each gas. Taking advantage of the linear behavior of ultra-high vacuum systems, the partial pressures are summed at the conclusion. To set up desorption, the flux data from the saved SR simulation is used (stored as textures, ie. absorbed flux densities assigned to locations on the chamber wall), along with the four molecule yield conversion files for each gas.

To calculate the absorbed dose, the conditioning time is required for which the approximate value of 200 hours (100 Ah dose) was chosen. Using these parameters, Molflow+ calculates the accumulated photon dose for every surface point, then interpolates the corresponding photon yield in the conversion files, then using the facet temperature and the ideal gas equation, converts the resulting outgassing flux from molecules/second to mbar l/s, the default desorption unit. Performing the conversion, we obtain that the total outgassing from the four gases is 5 10-7 mbar l/s. As for the pumping, the planned sputter ion pump under the absorber has a nominal pumping speed of 75 l/s for H 2 in the 10-9 mbar regime. However, for heavier gases it has to be adjusted as it is significantly lower. A sticking factor of 0.1 is assigned to the three ports of the vacuum chamber (one upstream and two downstream). This represents that at those locations the gas is in equilibrium with the rest of the machine, except for an approximate 10% of the particles that leave the modeled region and are pumped elsewhere. The pumping properties of the NEG-coated sections are different for each gas, as described below. Methane NEG does not pump methane [5], therefore its sticking is disabled in the simulation. However, on parts of the wall where SR is absorbed a local photo-induced conversion to other hydrocarbons [6-8] takes place, therefore it will be pumped by a linear speed of 10 l/s/m [9], which is set at those parts of the chamber wall and the absorber where SR flux is absorbed. Hydrogen Hydrogen is pumped with a sticking factor of about 0.008 [5], and NEG saturation is not significant. CO and CO2 Estimating pressure profile is more complex for these two gases. According to [5], initially they are pumped by NEG with a sticking factor of approx. 0.7, until they saturate the coating at an approximate molecule dose of 10 15 /cm 2, at which point the sticking is reduced to 0.002. Figure 5: NEG saturation and its effect on pumping speed and pressure profile Therefore the simulation was performed in an iterative way: first the NEG was assumed unsaturated. The conditioning process was modelled in increasing time steps corresponding to an elapsed time of 10, 100 100.000, 720.000 seconds. At each time step, the simulation was stopped, then the number of molecules pumped by every NEG element up to that moment was determined. If saturation occurred, based on interpolation from [5] a new, lower sticking factor was assigned locally for the next time slice, and the simulation resumed. In a total of 6 steps the 200 h conditioning time was reached, by which approximately 12 cm of the NEG film closest to the absorber reached saturation condition. On Fig. 5 it can be seen that at the border of the saturated region, the first (unsaturated) NEG section pumps the most intensively, therefore reducing pressure in a steep drop. Figure 6: partial gas pressures around the absorber The final pressure profile is shown in Fig.6. It can be seen that since the dynamic outgassing originates almost exclusively from the absorber surface, it introduces a locally elevated pressure in the 10-9 mbar region, which corresponds to a beam-gas scattering lifetime that is acceptable for the operation of MAX-IV. REFERENCES [1] R. Kersevan, SYNRAD, a Monte Carlo synchrotron radiation ray-tracing program, Proceedings of the 1993 Particle Accelerator Conference, vol.5., p 3848-3850 [2] R.Kersevan, J-L Pons, Introduction to Molflow+, JVST A27 (2009), p1017-1023 [3] B.L.Henke, E.M.Gullikson and J.C.Davis, X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E=50-30.000eV, Z=1-92, Center for X-Ray optics, lawrence Berkeley Laboratory, California 94720 [4] O. Groebner, A.G. Mathewson, P.C. Marin; Gas desorption from an oxygen free high conductivity copper vacuum chamber by synchrotron radiation photons, J. Vac. Sci. Technol. A 12, 846 (1994) [5] P. Chiggiato, P. C. Pinto - Ti-Zr-V non-evaporable getter films: from development to large scale production for the Large Hadron Collider, Thin Solid Films 515, 2 (2006) [6] V.V Anashin, I.R Collins, R.V Dostovalov, N.V Fedorov, A.A Krasnov, O.B Malyshev, V.L Ruzinov, Comparative study of photodesorption from TiZrV coated and uncoated

stainless steel vacuum chambers, Vacuum, Volume 75, Issue 2, 12 July 2004, p. 155-159 [7] V.V. Anashin, O.B. Malyshev, I.R. Collins, O. Gröbner, Photon-stimulated desorption and the effect of cracking of condensed molecules in a cryogenic vacuum system, Vacuum, Volume 60, Issues 1 2, January 2001, p. 15-24 [8] M. A. Gondal, Z. H. Yamani, A. Dastgeer, M. A. Ali, A. Arfaj, Photo-Conversion of Methane into Higher Hydrocarbons Using 355 NM Laser Radiation, Spectroscopy Letters Vol. 36, No. 4 [9] R. Kersevan, CERN, unpublished measurement data at ESRF