Sample Analysis Design PART III

Similar documents
Sample Analysis Design PART II

Sample Analysis Design Polyatomic Interferences

Sample Analysis Design Internal Standard

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Radiometric Dating (tap anywhere)

Element Cube Project (x2)

Solutions and Ions. Pure Substances

PERIODIC TABLE OF THE ELEMENTS

Nucleus. Electron Cloud

7. Relax and do well.

(please print) (1) (18) H IIA IIIA IVA VA VIA VIIA He (2) (13) (14) (15) (16) (17)

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start. Page # Points possible Points awarded

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

The Periodic Table. Periodic Properties. Can you explain this graph? Valence Electrons. Valence Electrons. Paramagnetism

Ar Ar + e - INDUCTIVELY+COUPLED+ PLASMA+SPECTROMETRY+ What+is+Plasma?+ FuncDon+of+Plasma+

Chemistry Standard level Paper 1

Samples compliant with the WATER

Guide to the Extended Step-Pyramid Periodic Table

NAME: FIRST EXAMINATION

Faculty of Natural and Agricultural Sciences Chemistry Department. Semester Test 1. Analytical Chemistry CMY 283. Time: 120 min Marks: 100 Pages: 6

Partial Energy Level Diagrams

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

Last 4 Digits of USC ID:

INSTRUCTIONS: Exam III. November 10, 1999 Lab Section

The exam must be written in ink. No calculators of any sort allowed. You have 2 hours to complete the exam. Periodic table 7 0

TRU Chemistry Contest Chemistry 12 May 21, 2003 Time: 90 minutes

The Periodic Table of Elements

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

Part 2. Multiple choice (use answer card). 90 pts. total. 3 pts. each.

Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

(C) Pavel Sedach and Prep101 1

CHEM 10113, Quiz 5 October 26, 2011

7. Relax and do well.

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

M11/4/CHEMI/SPM/ENG/TZ2/XX CHEMISTRY STANDARD LEVEL PAPER 1. Monday 9 May 2011 (afternoon) 45 minutes INSTRUCTIONS TO CANDIDATES

CLASS TEST GRADE 11. PHYSICAL SCIENCES: CHEMISTRY Test 4: Matter and materials 1

Chemistry Standard level Paper 1

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

If anything confuses you or is not clear, raise your hand and ask!

CHEM 107 (Spring-2005) Exam 3 (100 pts)

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Instructions. 1. Do not open the exam until you are told to start.

Atoms and the Periodic Table

Faculty of Natural and Agricultural Sciences Chemistry Department. Semester Test 1 MEMO. Analytical Chemistry CMY 283

8. Relax and do well.

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Chem Exam 1. September 26, Dr. Susan E. Bates. Name 9:00 OR 10:00

7) Applications of Nuclear Radiation in Science and Technique (1) Analytical applications (Radiometric titration)

1 Genesis 1:1. Chapter 10 Matter. Lesson. Genesis 1:1 In the beginning God created the heavens and the earth. (NKJV)

CHEM 107 (Spring-2004) Exam 2 (100 pts)

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

JRP SIB09 Elements GOOD PRACTICE GUIDE ON DEALING WITH INTERFERENCES IN ICP-MS FOR INVESTIGATING HIGH PURITY MATERIALS. Deliverable 1.2.

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Chapter 12 The Atom & Periodic Table- part 2

Made the FIRST periodic table

CHEM 130 Exp. 8: Molecular Models

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

CHEM 171 EXAMINATION 1. October 9, Dr. Kimberly M. Broekemeier. NAME: Key

8. Relax and do well.

ICP/MS Multi-Element Standards

Sources of Errors in Trace Element and Speciation Analysis

CHEM Come to the PASS workshop with your mock exam complete. During the workshop you can work with other students to review your work.

Chemistry 431 Practice Final Exam Fall Hours

8. Relax and do well.

Chapter 3: Stoichiometry

8. Relax and do well.

9/20/2017. Elements are Pure Substances that cannot be broken down into simpler substances by chemical change (contain Only One Type of Atom)

M10/4/CHEMI/SPM/ENG/TZ2/XX+ CHEMISTRY. Wednesday 12 May 2010 (afternoon) 45 minutes INSTRUCTIONS TO CANDIDATES

7. Relax and do well.

Topic 3: Periodicity OBJECTIVES FOR TODAY: Fall in love with the Periodic Table, Interpret trends in atomic radii, ionic radii, ionization energies &

M09/4/CHEMI/SPM/ENG/TZ1/XX+ CHEMISTRY. Monday 18 May 2009 (afternoon) 45 minutes INSTRUCTIONS TO CANDIDATES

Instructions. 1. Do not open the exam until you are told to start.

The Periodic Table of the Elements

BROOKLYN COLLEGE Department of Chemistry. Chemistry 1 Second Lecture Exam Nov. 27, Name Page 1 of 5

HANDOUT SET GENERAL CHEMISTRY II

CHEM 10123/10125, Exam 2

Why all the repeating Why all the repeating Why all the repeating Why all the repeating

7. Relax and do well.

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

8. Relax and do well.

INSTRUCTIONS: CHEM Exam I. September 13, 1994 Lab Section

Chemistry 185 Exam #2 - A November 5, Lab Day and Time: Instructions. 1. Do not open the exam until you are told to start.

Opening the analytical black box: Insights into interferences, corrections, and data quality

Using the Periodic Table

Our country, our future 525/1 S6 CHEMISTRY PAPER 1 DURATION: 2 HOUR 45 MINUTES


5 questions, 3 points each, 15 points total possible. 26 Fe Cu Ni Co Pd Ag Ru 101.

4.1 Atomic structure and the periodic table. GCSE Chemistry

UNIVERSITY OF CALGARY FACULTY OF SCIENCE MIDTERM EXAMINATION CHEMISTRY 353 READ ALL THE INSTRUCTIONS CAREFULLY

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

[ ]:543.4(075.8) 35.20: ,..,..,.., : /... ;. 2-. ISBN , - [ ]:543.4(075.8) 35.20:34.

Chemistry 126 Final Examination, Prof. Hanson, May, Section B or D (circle one) Seat Coordinate Name

CHEM 251 (Fall-2003) Final Exam (100 pts)

CHEM 167 FINAL EXAM MONDAY, MAY 2 9:45 11:45 A.M GILMAN HALL

02/05/09 Last 4 Digits of USC ID: Dr. Jessica Parr

Transcription:

Sample Analysis Design PART III

Sample Analysis Design Generating high quality, validated results is the primary goal of elemental abundance determinations It is absolutely critical to plan an ICP-MS analysis carefully from sample gathering to final analysis on the ICPMS Always create and follow an analysis design that shall permit you to follow the procedure for future samples, AND know what you did when looking at old data

Sample Analysis Design Goal: high quality, validated, quantitative determination of elemental concentrations/isotope ratios This goal can be achieved by: Specificity - only detecting isotope(s) of interest, not interferences, OR making sure that matrix effects do not play a role Sensitivity - can we differentiate the isotope of interest from the background signal? Accuracy - does the analysis represent the real value? Precision - how repeatable is the value?

Sample Analysis Design Sensitivity and Precision: generally defined by how well the instrument is tuned (assuming dilution factor is appropriate) Specificity and Accuracy: generally governed by how well you prepare your sample and set up your analysis method/parameters

Sample Analysis Design Spectroscopic interferences Matrix effects

Sample Analysis Design Interference analytical artifact which causes the ion signal in a sample to vary from an idealized (true) signal Interferences cause inaccurate analyses Two main types: 1. Spectroscopic 2. Nonspectroscopic

Sample Analysis Design Spectroscopic Interferences in ICP-MS 1. Isobaric overlap 2. Polyatomic ions 3. Refractory oxides 4. Doubly charged ions

Sample Analysis Design Isobaric Overlap Two different elements having the same nominal mass E.g., 40 Ca (96.9%) and 40 Ar (99.6%) Monoisotopic elements: B, Na, Al, Sc, Mn, As, Nb, Y, Rh, I, Cs, Pr, Tb, Ho, Tm, Au, Th None have isobaric interferences

Sample Analysis Design Isobaric Overlap A few multi-isotope elements have no interference free isotopes: E.g., In - 113 In 113 Cd, and 115 In 115 Sn Usually possible to choose an interference free isotope or one that is unlikely to be interfered upon strongly (either due to very low natural abundance of interfering element (isotope) or the interfering element (isotope) is not present in sample)

Sample Analysis Design Isobaric Overlap IF an isobaric interference is unavoidable, you can correct for it by measuring the counts on a non-interfering isotope of the interfering element CPS analyte = CPS total -CPS interferent *(X a /X b ) X a = abundance of interfering isotope X b = abundance of non-interfering isotope

Sample Analysis Design Polyatomic Interferences More serious than isobaric interferences Result from possible, short-lived combination of atomic species in the plasma or during ion transfer Common recombinants are Ar, H, and O Dominant elements in reagents also form polyatomic interferences - N, S, and Cl

Sample Analysis Design Polyatomic Interferences Analyzing deionized water with ICP-MS instrument we have solely H and O present (within the matrix ) Thus, peaks would be visible at masses: 41 ( 40 Ar + 1 H) 41 K 56 ( 40 Ar + 16 O) 56 Fe 80 ( 40 Ar + 40 Ar) 80 Se As well as other minor peaks from the minor isotopes of Ar and O

Sample Analysis Design Polyatomic Interferences If you acidify the deionized water with HNO 3 or H 2 O 2, these behave in the same manner as deionized water these acids are considered ideal matrices as they don t add unnecessary polyatomic interferences Acidification with HCl or H 2 SO 4 changes the situation since Cl and S can be used to form polyatomic ions

HCl matrix: Sample Analysis Design Polyatomic Interferences 35 Cl + 16 O = 51 V 37 Cl + 16 O = 53 Cr 40 Ar + 35 Cl = 75 As 40 Ar + 37 Cl = 77 Se

Sample Analysis Design Polyatomic Interferences H 2 SO 4 matrix: 32 S + 16 O = 48 Ti 32 S + 16 O + 16 O, or 32 S + 32 S = 64 Zn, 64 Ni 34 S + 16 O = 50 Ti, 50 V, 50 Cr 33 S + 16 O + 16 O = 65 Cu

Sample Analysis Design These interferences will be present just from the gas and solvent Therefore, if possible, solutions should be prepared with a weak (1-5% v/v) HNO 3 acid matrix Why not deionized water? acid helps keep elements from sticking to sides of test tubes and tubing during transport ionization efficiency is significantly lower relative to HNO 3

Sample Analysis Design Polyatomic Interferences The most serious polyatomic interferences are formed from the most abundant isotopes of H, C, N, O, Cl, and Ar So, if polyatomic interferences are present in plain deionized water with no other ions present, what happens in natural (complex) samples/matrices?

Sample Analysis Design Polyatomic Interferences Need to know the most abundant elements present in sample Is (are) there any one (or more) elements present that are in very high abundances? If so - then it s likely interferences could be formed from such abundant element(s) E.g., rock samples - high Si

Sample Analysis Design Polyatomic Interferences Typically, most polyatomic interferences are only present below mass 82 - since Ar, H, and O are by far the most abundant isotopes in the plasma, they form most interferences Counteractive measures: Proper machine settings (especially nebulizer flow rate and RF power) can minimize formation

Sample Analysis Design Polyatomic Interferences If a polyatomic interference is unavoidable, then a correction equation like the one for isobaric interferences can be used (assuming you are certain of the species of the interference)

Sample Analysis Design Refractory Oxides Refractory Oxides Occur because of incomplete sample dissociation or from recombination Always occur as an interference as an integral value of 16 mass units above the interfering element MO, MO 2, or MO 3 where M is the interfering element

Sample Analysis Design Refractory Oxides Elements with high oxide bond strength are most likely to form refractory oxide interferences Severity is expressed as MO/M as a percentage MO/M should be as low as possible, typically <5% MO/M minimized by adjusting nebulizer flow rate, z-axis position, and RF power

Sample Analysis Design Refractory Oxides Si, Ce, Zr, Ti, Sm, Mo, and P all form strong oxide bonds and may have severe oxide interferences Usually monitor the CeO/Ce ratio to make sure it s below 5%

Examples: Sample Analysis Design Refractory Oxides LREE on the HREE BaOon Eu MoOon Cd

Sample Analysis Design Refractory Oxides Again, correction equations can be applied but these lead to increased error, especially if the interference is large Oxide formation tends to not be stable and the corrections accumulate error quickly If there is a severe oxide interference, it s usually better to try to separate the interference from the analyte

Typically, Sample Analysis Design Refractory Oxides MO > MO 2 > MO 3 > MO 4

Sample Analysis Design Doubly Charged Ions Form when the 2nd ionization potential is less than the first ionization potential of Ar Typical of alkaline earths, a few transition metals, and some REE Low nebulizer flow rates increase doubly charged ion formation Interference signal is always M/2 where M is the element becoming doubly charged

How to avoid spectral MS interferences? Attempt to dry solutions prior to introduction to plasma - remove O and H gets rid of many polyatomic species (i.e. use a desolvating introduction system e.g. DSN 100) Optimize instruments settings so that formation is minimized and corrections are not severe Use simple matrices whenever possible Process samples prior to analysis to isolate elements of interest or remove potential interfering elements; e.g. ion exchange chromatography

How to avoid spectral MS interferences? Alternatively - use higher mass resolutions, MR medium resolution or HR high resolution Most overlaps are not exact using medium and high resolution modes Can completely separate the isotope of interest from interfering species However, consequence is loss of sensitivity