ARTICLE. II. Method 1. Detector Figure 1 shows a schematic view of the spectrometer. The spectrometer consists of two 2-inch-diameter BF 3

Similar documents
Benchmark Test of JENDL High Energy File with MCNP

Estimation of Radioactivity and Residual Gamma-ray Dose around a Collimator at 3-GeV Proton Synchrotron Ring of J-PARC Facility

Application and Validation of Event Generator in the PHITS Code for the Low-Energy Neutron-Induced Reactions

Recent activities in neutron standardization at NMIJ/AIST

Comparison with simulations to experimental data for photoneutron reactions using SPring-8 Injector

1.E Neutron Energy (MeV)

Progress in Nuclear Science and Technology, Volume 6,

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Status of the AGS Experiment for Mercury Spallation

Sequential Measurements of Cosmic-Ray Neutron Energy Spectrum and Ambient Dose Equivalent on the Ground

Response measurement of various neutron dose equivalent monitors in MeV neutron fields

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

Measurement of 40 MeV Deuteron Induced Reaction on Fe and Ta for Neutron Emission Spectrum and Activation Cross Section

Neutron and Gamma-ray Emission Double Dierential Cross Sections. *5 Energy Conversion Engineering, Kyushu University, Kasuga-koen, Kasuga-shi 816.

Measurements and Calculations of Neutron Energy Spectra Behind Polyethylene Shields Bombarded by 40- and 65-MeV Quasi-Monoenergetic Neutron Sources

Integral Benchmark Experiments of the Japanese Evaluated Nuclear Data Library (JENDL)-3.3 for the Fusion Reactor Design

Radiation damage calculation in PHITS

Neutronics Experiments for ITER at JAERI/FNS

Measurement of activation of helium gas by 238 U beam irradiation at about 11 A MeV

Estimate of Photonuclear Reaction in a Medical Linear Accelerator Using a Water-Equivalent Phantom

Development of displacement damage model in PHITS and comparison with other codes in a high-energy region

Characteristics of Filtered Neutron Beam Energy Spectra at Dalat Reactor

Radiation Shielding of Extraction Absorbers for a Fermilab Photoinjector

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

Altitude Variation of cosmic-ray neutron energy spectrum and ambient dose equivalent at Mt.Fuji in Japan

Fast-Neutron Production via Break-Up of Deuterons and Fast-Neutron Dosimetry

Benchmark Experiments of Accelerator Driven Systems (ADS) in Kyoto University Critical Assembly (KUCA)

External MC code : PHITS

Neutronic Design on a Small Accelerator based 7 Li (p, n) Neutron Source for Neutron Scattering Experiments

Neutron Metrology Activities at CIAE (2009~2010)

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency

An introduction to Neutron Resonance Densitometry (Short Summary)

Bonner Sphere Spectrometer. Cruzate, J.A.; Carelli, J.L. and Gregori, B.N.

Energy Response Characteristics of Several Neutron Measuring Devices Determined By Using the Scattered Neutron Calibration Fields of KAERI

The FLUKA study of the secondary particles fluence in the AD-Antiproton Decelerator target area.

Recent Developments of the PHITS code

ERINDA PAC 1/4 Testing the UAB Extended Range Bonner Sphere Spectrometer for high energy neutrons UU-TSL, Uppsala, Sweden UAB Barcelona

Code inter-comparison and benchmark for muon fluence and absorbed dose induced by an 18 GeV electron beam after massive iron shielding

Neutron Energy and Time-of-flight Spectra Behind the Lateral Shield of a High Energy Electron Accelerator Beam Dump, Part I: Measurements

1 cm. Cu electrode. Ge crystal. end cap. Dead layer. crystal cup

Analyses of shielding benchmark experiments using FENDL-3 cross-section data starter library for ITER and IFMIF applications

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

He-3 Neutron Detectors

Validation of the UFS Bonner Sphere Spectrometer and Monte Carlo Methods at the CERN-EU high energy Reference Field (CERF)

JRPR. Measurement of Neutron Production Doubledifferential Cross-sections on Carbon Bombarded with 430 MeV/Nucleon Carbon Ions.

Measurements of Radiation Doses Induced by High Intensity Laser between and W/cm 2 onto Solid Targets at LCLS MEC Instrument

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

A new neutron monitor for pulsed fields at high-energy accelerators

Neutron Spectrometry in Mixed Fields: Characterisation of the RA-1 Reactor Workplace

Convertible source system of thermal neutron and X-ray at Hokkaido University electron linac facility

Introduction to neutron rem meters

Neutron cross section measurement of MA

Improving neutron detection efficiency by using passive converters

M.Cagnazzo Atominstitut, Vienna University of Technology Stadionallee 2, 1020 Wien, Austria

anti-compton BGO detector

The possibility to use energy plus transmutation set-up for neutron production and transport benchmark studies

Evaluation and Measurements of Radioactive Air Emission and Off-Site Doses at SLAC

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

New irradiation zones at the CERN-PS

In our recent paper [1], applicability of the self-activation of an NaI scintillator has been studied for the photo-neutron monitoring around

SLAC-PUB Submitted to Radiation Protection and Dosimetry. Work supported by Department of Energy contract DE-AC02-76SF00515

The residual radioactivity of a water-copper beam dump for the TESLA Test Facility

High Energy Neutron Scattering Benchmark of Monte Carlo Computations

Radiation Transport Tools for Space Applications: A Review

Dosimetric Quantities and Neutron Spectra Outside the Shielding of Electron Accelerators

COMPARISON OF COMPUTER CODES APPLICABILITY IN SHIELDING DESIGN FOR HADRON THERAPY FACILITIES *

Analysis of Environmental Gamma-Ray Intensity Increase Due to Precipitation Using EGS4 Monte Carlo Simulation Code

Status of J-PARC Transmutation Experimental Facility

Calculations of Photoneutrons from Varian Clinac Accelerators and Their Transmissions in Materials*

Techniques to Measure Absolute Neutron Spectrum and Intensity for Accelerator Based Neutron Source for BNCT )

A Trial of Neutrino Detection from Joyo Fast Research Reactor

arxiv: v1 [physics.ins-det] 9 Apr 2018

The Possibility to Use Energy plus Transmutation Setup for Neutron Production and Transport Benchmark Studies

ARTICLE. Progress in Nuclear Science and Technology Volume 4 (2014) pp Yoshiko Harima a*, Naohiro Kurosawa b and Yukio Sakamoto c

Nuclear Cross-Section Measurements at the Manuel Lujan Jr. Neutron Scattering Center

Shielding Design Considerations for Proton Therapy Facilities

Study on Radiation Shielding Performance of Reinforced Concrete Wall (2): Shielding Analysis

Measurements with the new PHE Neutron Survey Instrument

Neutron-Induced Soft Error Analysis in MOSFETs from a 65nm to a 25 nm Design Rule using Multi-Scale Monte Carlo Simulation Method

1.1 Machine-Detector Interface

Spectrometry behind concrete shielding for neutrons produced by 400 MeV/u 12 C ions impinging on a thick graphite target

Fission Fragment characterization with FALSTAFF at NFS

Chapter 11: Neutrons detectors

Measurements of liquid xenon s response to low-energy particle interactions

Measurements of Neutron Capture Cross Sections for 237, 238 Np

Nuclear cross-section measurements at the Manuel Lujan Jr. Neutron Scattering Center. Michal Mocko

Precision neutron flux measurement with a neutron beam monitor

Monte Carlo Simulation concerning Particle Therapy

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

Neutron Cross-Section Measurements at ORELA

Radiation Protection Dosimetry (2007), Vol. 126, No. 1 4, pp Advance Access publication 11 May 2007

Validation of the MCNP computational model for neutron flux distribution with the neutron activation analysis measurement

Fluence-to-Dose Conversion Coefficients for Muons and Pions Calculated Based on ICRP Publication 103 Using the PHITS Code

Background simulations and shielding calculations

Gas-filled Detectors

A Measuring System with Recombination Chamber for Photoneutron Dosimetry at Medical Linear Accelerators

Measurement of induced radioactivity in air and water for medical accelerators

Improvements and developments of physics models in PHITS for radiotherapy and space applications

Transcription:

Progress in NUCLEAR SCIENCE and TECHNOLOGY, Vol. 1, p.52-56 (2011) ARTICLE Shielding Experiments at High Energy Accelerators of Fermilab (III): Neutron Spectrum Measurements in Intense Pulsed Neutron Fields of The 120-GeV Proton Facility Using A Current Bonner Sphere Technique Masayuki HAGIWARA 1*, Toshiya SANAMI 1, Yosuke IWAMOTO 2, Hiroyuki ARAKAWA 3, Nobuhiro SHIGYO 3, Nikolai MOKHOV 4, Anthony LEVELING 4, David BOEHNLEIN 4, Vaziri KAMRAN 4, Takashi NAKAMURA 5,6, Koji OISHI 6, Hideo HIRAYAMA 1, Hiroshi NAKASHIMA 2, Yukio SAKAMOTO 2 and members of JASMIN corroboration 1 High Energy Accelerator Research Organization, 1-1, Oho, Tsukuba, Ibaraki 305-0801, Japan 2 Japan Atomic Energy Agency, Tokai, Naka, Ibaraki 319-1195, Japan 3 Kyushu University, 744, Motooka, Nishi-ku, Fukuoka 819-0395, Japan 4 Fermilab, Batavia, IL 60510-5011, USA 5 Tohoku University, Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8578, Japan 6 Shimizu Corporation, 4-17, Etchujima, 3-chome, Koto-ku, Tokyo 135-8530, Japan Neutron energy spectra behind iron and concrete shields have been measured at the anti-proton production target station in Fermi National Accelerator Laboratory to provide shielding benchmark data of neutrons produced from 120-GeV proton induced reaction. To measure neutron spectra in the radiation bursts accompanied by the injection of intense pulsed proton beam into the target, we have developed a current readout technique of a multi-moderator spectrometer. We employed a pair of BF 3 proportional counters filled with different 10 B isotope enrichment gases, nat BF 3 (18% enrichment) and 10 BF 3 (96% enrichment) and used them as current readout ionization chambers to avoid signal pile-up problem. The spectrometer is aimed to discriminate neutrons from other particles such as -rays and muons incoming in short bursts by subtracting results of the nat BF 3 counter from that of the 10 BF 3 counter. The neutron spectrum obtained with the present technique is generally consistent with results of neutron-induced activation measurements. KEYWORDS: neutron energy spectra, multi-moderator spectrometer, radiation bursts, shielding benchmark data I. Introduction 1 Estimation of neutron production and transmission through shielding are very important at high energy accelerator facilities because neutrons have high penetrability through shielding and large contribution to the external dose. A number of shielding design of high energy accelerator facilities are performed using particle interaction and transport codes such as MCNPX, FLUKA, MARS, PHITS and so on. 1 4) These codes should be assessed based on benchmark measurements to ensure the calculation results. However, benchmark data on neutron energy spectra behind shields induced by high energy protons above 1 GeV are few because of lack of suitable facilities with a simple shielding structure and difficulties of neutron spectrum measurements especially for radiation bursts accompanied by beam operation with short pulse. 5-9) We have performed series of shielding experiments at the anti-proton production target facility (pbar target station) in FNAL to measure the induced activities and neutron flux around high energy accelerators in the Japanese and American Study of Muon Interaction and Neutron detection (JASMIN) collaboration. 10-12) The pbar target station has developed to provide anti-protons to the proton - anti-proton collider (TEVATRON) using 120 GeV protons hitting the *Corresponding Author, E-mail:hagi@post.kek.jp Atomic Energy Society of Japan target. This facility has a simple structure above the target and beam dump and source term can be clearly defined. On the other hand, intense pulsed proton beam impacted on the target with power of about 65 kw and pulse width of several micro seconds produce radiation bursts even above thick shields, which make it difficult to apply active counters to measurements of the neutron spectrum. In this study, we have developed a current readout Bonner sphere technique to measure neutron spectra in radiation bursts at the pbar target station by using a multi-moderator spectrometer (Bonner spheres) using a pair of BF 3 proportional counters filled with different 10 B isotope enrichment gases, nat BF 3 (18% enrichment) and 10 BF 3 (96% enrichment). The combination of different 10 B-enriched BF 3 counters allow to discriminate the signals of neutrons from other particles such as -rays and muons by subtracting results of the nat BF 3 counter from those of the 10 BF 3 counter. The neutron energy spectra behind shields are deduced by a conventional unfolding technique. The measured neutron energy spectra were compared with the results of neutron-induced activation measurements by means of reaction rates of nuclides. 11) II. Method 1. Detector Figure 1 shows a schematic view of the spectrometer. The spectrometer consists of two 2-inch-diameter BF 3 52

Shielding Experiments at High Energy Accelerators of Fermilab (III): Neutron Spectrum Measurements in Intense Pulsed Neutron Fields 53 spherical proportional counters (LND 2708) and four spherical polyethylene moderators with different diameters. One of these BF 3 counters is filled with 96% 10 B-enriched BF 3 gas ( 10 BF 3 ) and the other is 18% 10 B-enriched BF 3 gas ( nat BF 3 ). The gas pressure of these BF 3 counters is 760 Torr. The difference of outputs from 10 BF 3 counter and nat BF 3 counter is then considered to be only due to neutrons, since 10 B has a much higher capture cross-section to low-energy neutrons than that of the other stable isotope 11 B. The spherical moderators are made of polyethylene (density of 0.928 g/cm 3 ) and their diameters are 81, 110, 150, 230 mm. These moderators were originally designed by Uwamino et al. to use with a 5 atm 3 He proportional counter. 13) The 3 He counter was replaced with 10 BF 3 counter for this study to increase output charge produced in the neutron reaction owing to the higher Q-value of the 10 B(n, ) 7 Li reaction (2.79 MeV) than that of the 3 He(n,p) 3 H reaction (0.764MeV), which is important to use it as a current readout ionization chamber described in later. Fig. 1 The multi-moderator spectrometer used in this experiment. The spectrometer system has ten setups consist of two BF 3 counters ( 10 BF 3 and nat BF 3 ) and five moderator patterns (0, 81, 110, 150, 230 mm) Fig. 2 Electronics of the current readout mode for a BF 3 counter. High voltage is applied to the outer case of the BF 3 counter to operate it as a current readout ionization chamber 2. Signal readout Figure 2 shows a schematic diagram of electronics to operate the BF 3 counter as a current readout ionization chamber. In the current readout mode, high voltage was applied to the outer case of the BF 3 counter to read the current induced by 10 B(n, ) 7 Li reaction on the central wire. The applied voltage was determined to be 300 V, based on a measured saturation curve of the induced charge and leakage current. The current was fed to a current to frequency converter (I/F; Laboratory Equipment Co.), which converts input charge of 1 pc to 1 pulse, and recorded by a multi-channel scaler (MCS) to measure the signals synchronized with the beam injection and monitor the fluctuation. 3. Response functions Figure 3 shows the response functions for 10 BF 3 counters with polyethylene moderators of 0, 81, 110, 150, 230 mm diameters calculated using the MCNPX code (version 25f) 1) with the evaluated cross-section data libraries. The library used for neutron transport and reaction rate were LA150 (hydrogen, carbon and stainless steel) and ENDF/B-VI (boron and fluorine) 14). For the energy region that is not covered by these libraries, MCNPX default physics models were used. The calculation was performed with mono-energetic parallel neutron beam of different energies from 10-9 ev to 400 MeV for each moderator diameter. The response functions were measured with a conventional pulse readout system consists of a pre-amplifier and an amplifier and a multi-channel analyzer using 8.0 kev monoenergetic neutrons at the FRS facility in Japan Atomic Energy Agency. 15) The agreement between experimental and calculated values was rather good as shown in Fig. 3. The shape of response functions in the current readout mode should not be so different with that in the pulse readout mode, because the both output signals are based on the measurement of the charge ionized by the outgoing particles from the 10 B(n, ) 7 Li reaction. Iijima et al. report that the shape of the response function in a current readout mode agrees well with the calculation results of MCNPX as well as the response function in a pulse readout mode using a 3 He counter covered with polyethylene moderator. 16) Response [cm 2 ] 10 1 10 0 10-1 10-2 10-3 10-4 Calc. (Bare) Calc. (81mm) Calc. (110mm) Calc. (150mm) Calc. (230mm) 10-5 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 10 0 10 1 10 2 10 3 Neutron Energy [MeV] Fig. 3 Response functions of the 10 BF 3 counter with fivemoderators for neutron energies from 10-3 ev to 400 MeV 4. Calibration To obtain the conversion factor from the current output (pc) to corresponding number of the 10 B(n, ) 7 Li reaction in the BF 3 counters, we irradiate a pair of 10 BF 3 counters covered with the 230-mm-thick moderator using a neutron reference source of 3-Ci 241 Am-Be and measure the output counts per incident neutron in the pulse readout mode and the current readout mode. The 241 Am-Be neutron source was placed 74 cm and 17 cm away from the center of the spectrometer in the measurement of the pulse readout mode Vol. 1, FEBRUARY 2011

54 Masayuki HAGIWARAet al. and the current readout mode, respectively. The events induced by neutrons and -rays are clearly distinguished from their pulse height distribution. The integrated charge of -rays is estimated to be less than 0.1 % of that of neutrons owing to the high Q-value of the 10 B(n, ) 7 Li reaction. Although the contamination of -rays to the neutron measurement in the current readout mode is small, the source were covered with a 2-mm-thick lead cap in the measurement of conversion factor to suppress the -ray contamination. The conversion factors which were obtained from ratio of count rates between pulse mode and current mode is 56.6 and 61.8 pulse/pc for the 10 BF 3 counter and the nat BF 3 counter, respectively. III. Experiment Figure 4 shows geometry of the pbar target station shielding structure. The station consists of anti-proton production target made of multiple layers of Inconel and copper disks and graphite dump with iron and concrete shielding. The simple structure and material of the station is suitable to provide benchmark data of neutron penetration. The anti-proton production target is irradiated with 120 GeV proton beam provided from the Main Injector ring. The toroidal coil (TR105B) is placed just before the antiproton production target to monitor the beam intensity during this experiment. The typical time structure of the proton beam is 1.6 s pulse width, with a cycle time of 3.0 s. The power of the beam reached as high as 65 kw during our experiment. Downstream of the target, a graphite/aluminum dump is placed to absorb the remaining protons and secondary particles after the some extraction devices of produced anti-protons into the pbar extraction channel. These components are surrounded by 183-cm-thick iron and 122-cm-thick concrete shields. The area above these components is a restricted area during beam operation. The spectrometers of the 10 B counter and the nat B counter were placed at two points that is 50 cm aside from the beam axis above the target shown in Fig.4. Activation samples of In, Al, Cu, Bi were placed at the point on the beam axis above the target for the other measurement of neutron-induced activities after 10 days irradiation. 11) IV. Results Figure 5 shows a result of the MCS output of the 10 BF 3 counter with the 110-mm-diameter moderator located above the target. The measured time profile of the current induced in the counter was clearly synthesized with each injection of pulsed beam obtained from TR105B. The mean current was obtained by integrating the pulse data which are subtracted with the background current which is ~5 pa due to detector leakage current. The neutron spectra were deduced using an unfolding code, SANDII 17), with the response function and an initial guess spectrum calculated by the MARS15 code. 12) The mean count rates of the 10 B(n, ) 7 Li reaction in the counter were obtained by subtracting results of the nat BF 3 counter from that of the 10 BF 3 counter. Figures 6 show the neutron energy spectra obtained together with the spectrum calculated by the MARS15 used A-A' cross section B-B' cross section Backfill 120 GeV proton beam Point of activation measurements Points of counter measurements (B-10, B-nat) Above target Concrete Iron Target Dump Fig. 4 Geometry of pbar target station for the initial guess spectrum in the unfolding analysis. The Output charge (pc) 150 100 50 Current Bonner (pc) Toroidal beam monitor (*1x10 12 protons) 0 0 50 100 150 Time (s) 10 13 10 12 10 11 Fig. 5 MCS output obtained from 10 BF 3 counter covered with 110-mm-thick moderator located above the target. The beam data of TR105B are also plotted. measured spectrum has errors of the TR105R beam monitor (10%) and the I/F convertor (10%), and the statistical errors (9.3%). The total error of the neutron flux was estimated to be 17.1 % without ambiguity of the unfolding method. The calculation generally agrees with the experimental results, but underestimates thermal neutron flux and slightly overestimates fast neutron flux above 1 MeV. The difference of thermal neutron flux which is drastically affected by surroundings and gaps in shielding would be due to ambiguities on the geometry description in the MARS calculation. The difference of fast neutron flux would be due to ambiguities of densities and compositions of materials described in the MARS calculation. Figure 7 shows the comparison of reaction rates of nuclide between two experiments. Present results were deduced from the measured neutron spectra multiplying the corresponding Number of Incident protons PROGRESS IN NUCLEAR SCIENCE AND TECHNOLOGY

Shielding Experiments at High Energy Accelerators of Fermilab (III): Neutron Spectrum Measurements in Intense Pulsed Neutron Fields 55 activation cross-sections shown in ref.11. The reaction thresholds of 115 In(n,n ), 27 Al(n, ), 209 Bi(n,4n), 209 Bi(n,5n), 209 Bi(n,6n) are 0.6, 3.3, 22.6, 29.6, 38, 45.3 MeV, respectively. Preset results show in good agreement with the activation results within 30 % in the energy range. V. Conclusion Neutron flux [(n cm -2 lethargy -1 proton -1 ] 10-10 10-11 10-12 Present results Initial guess (MARS15) 10-1 10 0 10 1 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9 Neutron energy (ev) Fig. 6 Neutron energy spectra above the target unfolded with the initial spectrum calculated by the MARS code Fig. 7 Comparison of reaction rates of nuclides between present results and activation results We have developed a current readout Bonner sphere technique to measure neutron spectra in radiation bursts at the pbar target station by a multi-moderator spectrometer (Bonner spheres) using a pair of BF 3 proportional counters filled with different 10 B isotope enrichment gases, nat BF 3 (18% enrichment) and 10 BF 3 (96% enrichment) and measured the neutron energy spectra behind 183-cm-thick iron and 122-cm-thick concrete shields from 120 GeV proton induced reactions. Present result was consistent with the other experimental results by the activation method which shows reliability of both data. The initial guess spectrum calculated by MARS15 show slightly overestimation in MeV region and underestimation in the thermal energy region, which would be due to ambiguities on the geometry description in the MARS calculation should be investigated further. The current readout Bonner sphere technique would be helpful to measure shielding benchmark data in high energy proton accelerators under the intense burst field that is impossible to use active counter in pulse mode. Although the lack of sensitivity for over 10 MeV neutrons should be improved in further experiment, the spectrum results would be helpful to investigate particle interaction and transport codes for high energy region. Acknowledgment This work is supported by grand-aid of ministry of education (KAKENHI 19360432) in Japan. Fermilab is a U.S. Department of Energy Laboratory operated under Contract DE-AC02-07CH11359 by the Fermi Research Alliance, LLC. This work was partially performed under the Common-Use Facility Program of JAEA. References 1) J. S. Hendricks, et al., "MCNPX 2.6.0 Extensions," LA-UR-08-2216, Los Alamos National Laboratory (LANL), (2008). 2) A. Ferrari, P. R. Sala, Intermediate and high energy models in FLUKA: improvements, benchmarks and applications, Proc. Int. Conf. on Nucl. Data for Science and Technology, Ed. G. Reffo, A. Ventura and C. Grandi (Bologna: Italian Phys. Soc.), NDST-97, 59[I], 247 (1997). 3) N. V. Mokhov, "The Mars Code System User s Guide," Fermilab-FN-628, Fermi National Accelerator laboratory (FNAL), (1995), N. V. Mokhov, S. I. Striganov, "MARS15 Overview," Fermilab-Conf-07-008-AD, Fermi National Accelerator laboratory (FNAL), (2007). 4) H. Iwase, K. Niita and T. Nakamura, "Development of general-purpose particle and heavy ion transport Monte Carlo code," J. Nucl. Sci. Technol., 39[11], 1142 (2002). 5) N.Nakao et al., Nucl. Instrm. Meth. B 266, 93 (2008). 6) G. R. Stevenson et al., Health Phys., 43, 13 (1982). 7) S. Ban et al., Nucl. Instum. Methods, 174, 271 (1980). 8) M.Awschalom, et al., Nucl.Instrum.Meth. 136, 521 (1976). 9) H.Nakashima, et al., Proc. of the Shielding Aspects on Accelerator, Target and Irradiation Facilities SATIF6, SLAC, Apr. 10-12, 2002, p. 27 (2002). 10) H. Nakashima, et.al, Nucl. Technol., 168, 482(2009) 11) H. Yashima et al., Proc. of fifth International Symposium on Radiation Safety and Detection Technology (ISORD-5), Kitakyushu, Japan, June. 15-17, 2009 to be published. 12) T. Sanami et al, Applicability of a Bonner sphere technique for neutron spectrum measurements in a pulsed neutron field of the 120-GeV proton facility, Proc. of 22nd workshop on Radiation Detectors and Their Uses, Tsukuba, Japan, Feb. 5-7, 2008, p.148(2008). 13) Y.Uwamino et al., Nucl. Instrm. Meth. A 239, 299 (1985). 14) M. B. Chadwick et al., Cross-section evaluations to 150MeV for accelerator-driven systems and implementation in MCNPX, Nucl. Sci. Eng., 131, 293 (1999). 15) Y. Tanimura et al., "Construction of Monoenergetic Neutron Calibration Fields Using 45 Sc(p,n) 45 Ti Reaction at JAEA", Vol. 1, FEBRUARY 2011

56 Masayuki HAGIWARAet al. Radiat. Prot. Dosim., 126, 8 (2007). 16) K. Iijima et al, Proc. of fifth International Symposium on Radiation Safety and Detection Technology (ISORD-5), Kitakyushu, Japan, June. 15-17, 2009 to be published. 17) W. McElroy, S. Berg, T. Crocket, G. Hawkins, A computer automated iterative method for neutron flux spectra determination for foil activation, AFWL-TR-67-41 (1967). PROGRESS IN NUCLEAR SCIENCE AND TECHNOLOGY