Odor Detection and Analysis using GC/SAW znose

Similar documents
Real Time On-Site Odor and VOC Emission Measurements Using a znose

Edward J. Staples Page ONDCP INTERNATIONAL TECHNOLOTGY SYMPOSIUM March 8-10, 1999 Washington, DC

Application. Gas Chromatography February Introduction

MODELING, DESIGN AND EXPERIMENTAL CARACHTERIZATION OF MICRO-ELECTRO ELECTRO-MECHANICAL- SYSTEMS FOR GAS- CHROMATOGRAPHIC APPLICATIONS

Implementation of Electronic Nose Technique In Explosives Detection

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Rapid Catalyst Screening Reactors

A Micro-GC Based Chemical Analysis System

2B Technologies, Inc. An InDevR Company

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Experimental Determination of Pyrolysis Products from Carbon/Resin Ablative Materials

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

SELECTED ION FLOW TUBE MASS SPECTROMETRY. Interscience Expert Center: VIP Meeting 15 Sept. 2009

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Odours from Food Packagingan Analytical Challenge?

A New Way to Extract Off-Flavor Compounds in the Aquatic Environment. Stir Bar Sorptive Extraction (SBSE)

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Vapor Intrusion Sampling Options: Performance Data for Canisters, Badges, and Sorbent Tubes for VOCs

Chapter 3: Source Measurement Techniques

Introduction to GC/MS

Dynatherm Thermal Desorption Systems

Gas Chromatography. Chromatography Laboratory Course. Dr. Christian Jungnickel Chromatography Course GC September 2005

White Paper. Application of GC-MS/MS in the Analysis of Taints and Off Flavours. Alan Rose Technical Specialist. Donna Byrom Technical Specialist

Varian Galaxie Chromatography Data System for Preparative HPLC

Development of Portable GC/MS System with Benchtop Performance for Critical DoD Applications. Mitch Wells, Ph.D. Philip Tackett, Ph.D.

UV3000. Accurate, precise, and portable ambient gas point analyzer

Explosive Screening by Vapour Detection: Operational Aspects

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Emission measurements according to, M1 (3 appendices)

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

Analysis of Sulfur-Containing Flavor Compounds By GC/MS With A PFPD

U.S. EPA Method 8270 for multicomponent analyte determination

GAS CHROMATOGRAPHY (GC)

Characterization of Odor & Taste Components Using Olfactory Detection and Solid Phase Microextraction GC-MS

C146-E209. Headspace Samplers. HS-20 Series

M1 Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

Gas Chromatography. Introduction

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

2401 Gas (liquid) Chromatography

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Headspace Technology for GC and GC/MS: Features, benefits & applications

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

2681 Parleys Way Suite 201 Salt Lake City, UT AccuSense Value Proposition

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

Chemistry Gas Chromatography: Separation of Volatile Organics

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

3590/ Laboratory

Magnitudes of Back Diffusion During Long-Term Diffusive Sampling of Volatile Organic Compounds Using Carbotrap and Chromosorb 106

Determination of releasable 2,4,6-trichloroanisole in wine by cork stoppers (Resolution OIV-Oeno 296/2009)

Application Note S/SL

SIFT-MS. technology overview

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD)

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Application Note 032

A STUDY OF VOLATILE ORGANIC CARBON POLLUTION ON A UNIVERSITY CAMPUS DUE TO TRAFFIC

DEVELOPMENT OF A SENSITIVE THERMAL DESORPTION GC-MS METHOD USING SELECTIVE ION MONITORING FOR A WIDE RANGE OF VOCS

Determination of volatiles in Food sample preparation strategies and techniques Dr Kathy Ridgway

Development of on-line and Field Dual TD-GC-FID/MS for Automatic and Continuous Volatile Organic Compounds (VOCs) Ambient Air and Odour Monitoring

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

CHEM 429 / 529 Chemical Separation Techniques

Quantification of Rice Aroma, 2-Acetyl-1-Pyrroline (2-AP), Using TurboMatrix Headspace Trap Coupled with GC/NPD and GC/MS

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Test Report in accordance CDPH-IAQ

AUTONOMOUS, REAL TIME DETECTION OF 58 VOCS IN THE PANAMA CANAL

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Petrochemical. Transformer Oil Gas Analysis - TOGA

Centri. A breakthrough in sample automation and concentration for GC MS

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Author. Abstract. Introduction

Test Report in accordance CDPH-IAQ

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

CHEM Experiment Five Gas Chromatographic Analysis Of A Phenolic Extract. Objectives:

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Determination of Volatile Substances Proof of Food Adulteration

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

HPLC Praktikum Skript

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Introduction. Chapter 1. Learning Objectives

GC-FTIR Analysis of Lemon Extract: Gram-Schmidt Chromatogram. Solvent Peak(2.20) H 3 C CH Air Peak(2.08)

Tar analysis by Solid Phase Adsorption (SPA) associated with Thermal Desorption (TD) and Gas Chromatography (GC) analysis

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Maximizing Sample Throughput In Purge And Trap Analysis

Real laboratory, virtual laboratory or remote laboratory: What is the most efficient way?

UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

VOC TEST REPORT CDPH

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

10/27/10. Chapter 27. Injector typically 50 C hotter than oven

Chromatography. Gas Chromatography

High Accuracy High Speed in Your Process

Transcription:

Complimentary Copy Odor Detection and Analysis using GC/SAW znose Edward J. Staples Electronic Sensor Technology 1077 Business Center Circle Newbury Park, California 91320 Ph. 1-805-480-1994 FAX 1-805-480-1984 Email: staples@estcal.com Shekar Viswanathan School of Engineering and Technology, National University 11255 North Torrey Pines, La Jolla, California 92037 Ph. 1-858-442-1586 Email: sviswana@nu.edu An Electronic Version of this paper is available using the following Link: http://www.estcal.com/techpapers/environmental/awma-2005.pdf 1

Odor Detection and Analysis using GC/SAW znose Edward J. Staples Electronic Sensor Technology, 1077 Business Circle, Newbury Park, California, U.S.A and Shekar Viswanathan + School of Engineering and Technology National University, 11255 North Torrey Pines, La Jolla, California 92037, U.S.A. Abstract New analytical methods for detection and analysis of odors are needed for quick evaluation of odor problems. An important requirement for an odor profiling system is that it must recognize odors based upon their full chemical signature. Conventional electronic noses (enoses) produce a recognizable response pattern using an array of dissimilar but not specific chemical sensors. Electronic noses have interested developers of neural networks and artificial intelligence algorithms for some time, yet physical sensors have limited performance because of overlapping responses and physical instability. A new type of electronic nose, called the znose, is based upon ultra-fast gas chromatography, simulates an almost unlimited number of specific virtual chemical sensors, and produces olfactory images based upon aroma chemistry. A library of retention time indices for chemicals allows for the creation of hundreds of specific virtual chemical sensors. Virtual chemical sensors combined with odor profiling can be an effective method for recognizing the presence of odorous emissions. Chemical libraries and electronic odor profiles allows users to quickly distribute signatures of odorous vapors of any kind. The znose is able to perform analytical measurements of volatile organic vapors and odors in near real time with part-per-trillion sensitivity. Separation and quantification of the individual chemicals within an odor is performed in seconds. Using a patented solid-state mass-sensitive detector, picogram sensitivity, universal non-polar selectivity, and electronically variable sensitivity is achieved. An integrated vapor preconcentrator coupled with the electronically variable detector, allow the instrument to measure vapor concentrations spanning 6+ orders of magnitude. In this paper, the application of znose, as a useful environmental tool for quantifying volatile organics in ambient air is presented. + sviswana@nu.edu 2

Odor Assessment with an Electronic Nose Conventional odor assessment methods use subjective human panels to evaluate ambient air samples collected in tedlar bags and a summary report using human descriptors such as foul, sweet, pungent, etc. is produced. These reports are useful but difficult to interpret and are certainly not quantitative. A complimentary odor analysis method using an electronic nose called the znose is shown in Figure 1. This portable instrument is able to perform analytical measurements of volatile organic vapors and odors in near real time. Separation and quantification of the individual chemicals within an odor is performed in seconds. An integrated vapor preconcentrator coupled with the electronically variable sensitivity, allow the instrument to measure vapor concentrations spanning 6+ orders of magnitude. In internal pump samples ambient air at ½ milliliter per second and thus the volume of directly sampled air samples is only 5-10 milliliters. Even with such small volume air samples the instrument is able to achieve sensitivity in the low ppb and even ppt concentration ranges. A handheld air sampler consisting of a battery operated sample pump and a tenax filled probe enables organic compounds associated with odors to be remotely collected. Examples of odors being remotely collected are shown in Figure 2. Using a sample flow of 1 liter/minute allows much larger volumes of air to be tested than with by direct sampling. After sampling the tenax probe is removed from the handheld sampler and then inserted into the inlet of the electronic nose where the collected organic compounds are desorbed and measured. Figure 1- Portable znose odor analyzing system and battery operated air sampler. 3

Figure 2- Battery operated remote sampler can be used to collect vapors from many different types of odors. How the znose Quantifies the Chemistry of Odors A simplified diagram of the znose system shown in Figure 2 consists of two parts. One section uses helium gas, a capillary tube (GC column) and a solid-state detector. The other section consists of a heated inlet and pump, which samples ambient air. Linking the two sections is a loop trap, which acts as a preconcentrator when placed in the air section (sample position) and as an injector when placed in the helium section (inject position). Operation is a two-step process. Ambient air (aroma) is first sampled and organic vapors collected (preconcentrated) on the trap. After sampling the trap is switched into the helium section where the collected organic compounds are injected into the helium gas. The organic compounds pass through a capillary column with different velocities and thus individual chemicals exit the column at characteristic times. As they exit the column they are detected and quantified by a solid-state detector. An internal high-speed gate array microprocessor controls the taking of sensor data, which is transferred to a user interface or computer using an RS-232 or USB connection. Calibration is accomplished using a single n-alkane vapor standard. A library of retention times of known chemicals indexed to the n-alkane response (Kovats indices) allows for machine independent measurement and compound identification. The time derivative of the sensor spectrum yields the spectrum of column flux, commonly referred to as a chromatogram. The chromatogram response (Figure 4) of n-alkane vapors (C6 to C14) provides an accurate measure of retention times. 4

Figure 3- Simplified diagram of the znose showing an air section on the right and a helium section on the left. A loop trap preconcentrates organics from ambient air in the sample position and injects them into the helium section when in the inject position. Kovat s Indices (n-alkanes) Machine-independent retention times (Kovat s indices) for known odoriferous compounds are determined by retention time comparisons with vapors from an n-alkane vapors as shown in Figure 4. As an example phenol has an index of 988, slightly less than decane (C10), which has an index of 1000. The indices for trichloroanisole (TCA) and trichlorophenol (TCP) are 1330 and 1377 respectively because their corresponding response peaks lie between those of C13 and C14. Instrument software automatically displays Kovats indices for all compound peaks detected in an odor. Figure 4- Kovats retention time indices are made relative to n-alkanes (in red). 5

Compound Identification: Chemical Odor Library Instrument software contains a library of over 700 chemical compounds and their human odor descriptors based upon Kovat s indices. Clicking on an unknown peak displays the nearest library compound entry. Human odor perceptions for each compound can help in identification of the compound. The library is user-expandable and a typical entry for TCA, which has a moldy odor, is shown in Figure 5. Figure 5- A chemical library based upon Kovat s indices and human odor perception is useful for identification of unknown compounds. Virtual Chemical Sensors with Alarms A technique of creating virtual chemical sensors simplifies the measurement of specific malodorous compounds. Virtual sensors (e.g. phenol, TCA, and TCP) are user defined by placing bands or zones (shown as red hatching) over the target compounds as shown in Figure 6. With alarm levels specified, the chromatogram display is converted into an array of virtual chemical sensors shown on the right. Figure 6- Virtual chemical sensors with user selectable alarm levels simplify measurements. 6

Quantification of Odor Measurements The concentration of different compounds in odors can be measured by calibrating the instrument with chemical vapor standards or by direct injection of target compounds. Sampling air from a tedlar bag with a known vapor concentration of target compounds is shown in Figure 7-A. After a known amount of standard vapor has been preconcentrated the collection probe is transferred to the inlet of the instrument (B) and a temperature controlled heater (C) used to release the trapped compounds so then can be transferred to the internal preconcentrator and injected into the GC for analysis.. Figure 7- Standard vapors from a tedlar bag are collected by sample probe (A) which is then inserted into the inlet of the instrument (B) and heated to release the absorbed compounds (C) for analysis. Adding a high flow preconcentrator greatly increases the sensitivity of odor measurements compared to direct sampling. This is demonstrated in Figure 8 where the response in counts from direct and indirect sampling using nearly equal sample times is compared. Using the high flow sampler a sensitivity gain of 30X is achieved. Figure 8- Sensitivity comparison of a 10 second direct sampling measurement with a 15 second high flow sampling measurement using the remote vapor collector. 7

Even higher sensitivity is possible using increased sample times. Sensitivity and response factors using a 1-minute sample of a low concentration vapor standard with the same six analytes is shown in Figure 9. The minimum detection level of benzene based upon signal to noise is near 1 ppb while that of o-xylene is even lower at 50 ppt. Lower detection levels can be achieved by increasing sample time. Figure 9-1 min sample of a low concentration 6-compound standard odor mixture from tedlar bag. Laboratory Ambient Air Measurements Measurement of laboratory air near a fume hood using a 1-minute sample (750 milliliters) is demonstrated in Figure 10. The concentration of the target compounds is 8.6 ppb benzene, 83.8 ppt of TCE, 1.6 ppb toluene, 1.52 ppb PCE, 1.52 ppb ethyl benzene, and 694 ppt of o-xylene in ambient air near the hood. Figure 10- Measurement of laboratory odors with the remote vapor sampler. 8

Destructive Odors Many offensive odors contain chemicals, which can taint and effectively destroy aromatic products such as food and beverages. The anisoles are a major source of economic loss in the wine industry and tainting from shipping containers, packaging materials, and storage areas is a major concern. These compounds originate when wood preservatives (such as pentachlorophenol and tribromophenol) are sprayed onto cut building lumber, creating a great potential source of stinky TCA (2,4,6-trichloroanisole), TBA (2,4,6- tribromoanisole), and other related compounds listed in Table I Table I- Destructive odoriferous chemicals MW VP Kovats 2,4,6-Trichloroanisole 211.48 0.0228 1369 2,4,6-Trichlorophenol 197.45 0.008 1405 2,4,6-Tribromoanisole 344.83 0.000644 1668 2,4,6-Tribromophenol 330.8 0.000303 1727 2,3,4,5-Tetrachloroanisole 245.92 0.00319 1655 2,3,4,5-Tetrachlorophenol 231.89 0.000339 1723 Pentachloroanisole 280.37 0.000592 1774 Pentachlorophenol 266.34 0.00011 1858 To illustrate by example, odors from within a cargo container were sampled by concentrating a 2.25 liter volume of ambient air as shown in Figure 11. The sample probe was inserted into the analyzer and tested for traces of TCA, TCP, TBA, TBP, and PCP. The results, shown in Figure 12, showed 5.3 ng of TCA and 9.9 ng of TCP were present in the air sample. This amount of TCA (272 ppt) could be very destructive to any aromatic products were they to be shipped in this container. Figure 11- Odors in a cargo container. Figure 12- TCA and TCP detected in air sample. 9

Summary A new analytical method for detection and analysis of odors using an ultra-high speed gas chromatograph and a battery powered remote sampler can be used to quantify odors of all kinds in remote locations in near real time. An integrated vapor preconcentrator and electronically variable solid-state sensor allow odors to be measured over a wide range of compound concentrations. Real time analytical measurements are complimentary to conventional odor assessment methods and do not replace the need for human sensory panels. The use of a battery operated high-flow air sampler enables vapor samples to first be concentrated on Tenax filled probes which are then transferred to a portable ultra-fast vapor analyzer where the collected organic compounds are desorbed and measured. Using the remote sampler, the sensitivity of odor measurements is greatly increased. Because the measurement is based upon gas chromatography, independent laboratory validation can also be carried out and results compared. Using ultra-high speed chromatography, an almost unlimited number of specific virtual chemical sensors can be created along with chemical profiles (olfactory images), and even human odor descriptors based upon a library of odor causing chemicals using retention time indices. Chemical odor profiling combined with human odor panels can be an effective method for recognizing and eliminating sources of odorous emissions. The odor measurement method presented in this paper can be used in a wide variety of applications. Indoor and outdoor air pollution, factories and offices for worker safety and comfort, early detection of food spoilage, food storage facilities and warehouses, sanitation and waste treatment facilities, animal farms, and even medical diagnosis based upon human and animal body odors, are just a few applications for this technology. 10