Source: Chapter 5: Errors in Chemical Analyses

Similar documents
Chapter 5. Errors in Chemical Analysis 熊同銘.

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 03: EXPERIMENTAL ERROR

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 03: EXPERIMENTAL ERROR

Statistics: Error (Chpt. 5)

03.1 Experimental Error

Data Analysis I. CU- Boulder CHEM-4181 Instrumental Analysis Laboratory. Prof. Jose-Luis Jimenez Spring 2007

Measurements Chapter 3

ANALYTICAL CHEMISTRY 1 LECTURE NOTES

Why the fuss about measurements and precision?

Chem 321 Lecture 4 - Experimental Errors and Statistics 9/5/13

Ch 3. EXPERIMENTAL ERROR

NaOH (aq) + HCl (aq) NaCl (aq) + H 2 O (l)

Chapter 2. Theory of Errors and Basic Adjustment Principles

Topic 2 Measurement and Calculations in Chemistry

ADVANCED ANALYTICAL LAB TECH (Lecture) CHM

Experiment 2: Analysis of Commercial Bleach Solutions

Lecture 3. - all digits that are certain plus one which contains some uncertainty are said to be significant figures

Chapters 0, 1, 3. Read Chapter 0, pages 1 8. Know definitions of terms in bold, glossary in back.

2002 D Required 2001 D Required

Uncertainty, Error, and Precision in Quantitative Measurements an Introduction 4.4 cm Experimental error

Protocol for the design, conducts and interpretation of collaborative studies (Resolution Oeno 6/2000)

ents & Uncertainties Significant Figures 1.005, Round best to the experimental want to meters and use 300 m 2. significant figures because of

Introduction to Uncertainty and Treatment of Data

Chemistry Calibration of a Pipet and Acid Titration

Glossary of Common Laboratory Terms

11.1 Uncertainty and error in measurement (1 Hour) 11.2 Uncertainties in calculated results (0.5 Hour) 11.3 Graphical techniques (0.

Topic 11: Measurement and Data Processing and Analysis. Topic Uncertainties and Errors in Measurement and Results

Measurements, Sig Figs and Graphing

CHEM 334 Quantitative Analysis Laboratory

precision accuracy both neither

1 Measurement Uncertainties

PHYS 2211L - Principles of Physics Laboratory I Propagation of Errors Supplement

AP Chemistry Unit 2 Test (Chapters 3 and 4)

Experiment 1 - Mass, Volume and Graphing

+ H 2 O Equation 1. + NaOH CO 2 Na

experiment3 Introduction to Data Analysis

Chapter 3 Math Toolkit

METHOD 3665 SULFURIC ACID/PERMANGANATE CLEANUP

Accuracy and Precision of Laboratory Glassware: Determining the Density of Water

Experiment 7: Adsorption Spectroscopy I, Determination of Iron with 1,10 Phenanthroline

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater.

EXPERIMENT 22 SOLUBILITY OF A SLIGHTLY SOLUBLE ELECTROLYTE

Safety Note: Safety glasses and laboratory coats are required when performing this experiment

Solubility Product Constant (K sp ) and the Common-Ion Effect for Calcium Iodate, a Salt of Limited Solubility

INTRODUCTORY CHEMISTRY Concepts and Critical Thinking

Chapter 5-7 Errors, Random Errors, and Statistical Data in Chemical Analyses

Compulsory textbook. Recommended textbooks

Understanding and Interpreting Soil and Plant Tissue Lab Reports

1 Measurement Uncertainties

-However, this definition can be expanded to include: biology (biometrics), environmental science (environmetrics), economics (econometrics).

$ % K st. K D [ I 2 ] Aqueous. [ I 2 ] Hexane. % Aqueous

EXPERIMENT 30A1: MEASUREMENTS. Learning Outcomes. Introduction. Experimental Value - True Value. 100 True Value

Errors. Accuracy and precision

[Ca 2+ ] = s (3) [IO - 3 ] = 2s (4)

Precipitation Titrimetry

Spectrophotometric Determination of Ferrocyanide in Effluents

Part 01 - Notes: Identifying Significant Figures

Chemistry 11. Unit 2: Introduction to Chemistry. Measurement tools Graphing Scientific notation Unit conversions Density Significant figures

Introduction to Chemistry Techniques Prelab (Week 1) 2. Determine the number of significant figures in each of the following numbers.

Measurements and Errors

Identification Of The Common Laboratory Glassware, Pipettes And Equipment. BCH 312 [Practical]

Chapter 3 Experimental Error

MEASUREMENT AND STATISTICAL TREATMENT OF EMPERICAL DATA

PREPARATION FOR CHEMISTRY LAB: FLUORIDE IN WATER

Lab 1: Precision and accuracy in glassware, and the determination of density

Uncertainties in Measurement

CHAPTER 2: SCIENTIFIC MEASUREMENTS

PARADISE VALLEY COMMUNITY COLLEGE PHYSICS COLLEGE PHYSICS I LABORATORY

Propagation of Uncertainty

Determining the Rate Law for a Chemical Reaction

(a) A student carries out an investigation based on the redox systems shown in Table 5.1 below. redox system E o / V 1 Ni 2+ (aq) + 2e Ni(s) 0.

Introduction to Measurement

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

Measurements and Data Analysis

Determination of Orthophosphate Ion

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

Objectives. Concepts in Quality Control Data Management. At the conclusion, the participant should be able to:

Experiment 5: Determining the Stoichiometry and Products of a Redox Reaction

Chemistry Determination of Mixed Acids

RAPID KJELDAHL BENCHNOTES

Measurements and Calculations. Chapter 2

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

PURPOSE: To determine the Rate Law for the following chemical reaction:

INTERNATIONAL OLIVE COUNCIL

Source slideplayer.com/fundamentals of Analytical Chemistry, F.J. Holler, S.R.Crouch. Chapter 6: Random Errors in Chemical Analysis

University of Massachusetts Boston - Chemistry Department Physical Chemistry Laboratory Introduction to Maximum Probable Error

Write an overall equation for the first stage in the rusting of iron.

Synthesis and Analysis of a Coordination Compound

Titration of HCl with Sodium Hydroxide

CHEM 1305: Introductory Chemistry

GENERAL INSTRUCTIONS GENERAL PREPARATION

FACULTY OF SCIENCE DEPARTMENT OF CHEMICAL TECHNOLOGY NATIONAL DIPLOMA: ANALYTICAL CHEMISTRY (4 YEARS) ANALYTICAL CHEMISTRY 1AY1 (THEORY)

Lesson 5: Significant Digits. AKA Significant Figures

Clocking the Effect of Molarity on Speed of Reaction. reaction. While most people do assume that the temperature of the solution is often the most

Chemistry Lab: Introduction to Measurement

EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

Method Validation. Role of Validation. Two levels. Flow of method validation. Method selection

Chapter 8: Sampling, Standardization, and Calibration

The periodic table currently lists 116 different atoms. New atoms are being discovered.

Transcription:

Source: Chapter 5: Errors in Chemical Analyses

Measurements invariably involve errors and uncertainties. it is impossible to perform a chemical analysis that is totally free of errors or uncertainties We can only hope to minimize errors and estimate their size with acceptable accuracy Errors are caused by faulty calibrations or standardizations or by random variations and uncertainties in results. Frequent calibrations, standardizations, and analyses of known samples can sometimes be used to lessen all but the random errors and uncertainties. The term error has two slightly different meanings. 1) error refers to the difference between a measured value and the true or known value. 2) error often denotes the estimated uncertainty in a measurement or experiment. We can only hope to minimize errors and estimate their size with acceptable accuracy

Every measurement is influenced by many uncertainties, which combine to produce a scatter of results. Figure 5-1 Results from six replicate determinations of iron in aqueous samples of a standard solution containing 20.0 ppm iron(iii). Note that the results range from a low of 19.4 ppm to a high of 20.3 ppm of iron. The average, or mean value, x, of the data is 19.78 ppm, which rounds to 19.8 ppm Because measurement uncertainties can never be completely eliminated, measurement data can only give us an estimate of the true value. However, the probable magnitude of the error in a measurement can often be evaluated. It is then possible to define limits within which the true value of a measured quantity lies with a given level of probability. Before beginning an analysis ask, What maximum error can be tolerated in the result? The answer to this question often determines the method chosen and the time required to complete the analysis.

5A Some important terms To improve the reliability and to obtain information about the variability of results, two to five portions (replicates) of a sample are usually carried through an entire analytical procedure. Replicates are samples of about the same size that are carried through an analysis in exactly the same way. Individual results from a set of measurements are seldom the same Usually, the best estimate is considered to be the central value for the set. The central value of a set should be more reliable than any of the individual results. Usually, the mean or the median is used as the central value for a set of replicate measurements. An analysis of the variation in the data allows us to estimate the uncertainty associated with the central value.

The Mean and the Median The mean, also called the arithmetic mean or the average, is obtained by dividing the sum of replicate measurements by the number of measurements in the set: x N i 1 N x i The symbol x i means to add all of the values x i for the replicates; x i represents the individual values of x making up the set of N replicate measurements. The median is the middle value in a set of data that has been arranged in numerical order. The median is used advantageously when a set of data contain an outlier. An outlier is a result that differs significantly from others in the set. An outlier can have a significant effect on the mean of the set but has no effect on the median.

Precision * Precision describes the agreement among several results obtained in the same way. Describes the reproducibility of measurements. * Precision is readily determined by simply repeating the measurement on replicate samples. * Precision of a set of replicate data may be expressed as standard deviation, variance, and coefficient of variation. * d i, deviation from mean, is how much x i, the individual result, deviates from the mean. d x x Accuracy i i Accuracy indicates the closeness of the measurement to the true or accepted value and is expressed by the error. Accuracy measures agreement between a result and the accepted value. Accuracy is often more difficult to determine because the true value is usually unknown. An accepted value must be used instead. Accuracy is expressed in terms of either absolute or relative error.

Figure 5-2 Note that we can have very precise results (upper right) with a mean that is not accurate and an accurate mean (lower left) with data points that are imprecise.

Absolute Error * The absolute error of a measurement is the difference between the measured value and the true value. If the measurement result is low, the sign is negative; if the measurement result is high, the sign is positive. E x i x t Relative Error The relative error of a measurement is the absolute error divided by the true value. Relative error may be expressed in percent, parts per thousand, or parts per million, depending on the magnitude of the result. E r x i x t x t 100%

Types of Errors in Experimental Data Results can be precise without being accurate and accurate without being precise. Each dot represents the error associated with a single determination. Each vertical line labeled (xi - xt) is the absolute average deviation of the set from the true value. Figure 5-3 Absolute error in the micro-kjeldahl determination of nitrogen.

Chemical analyses are affected by at least two types of errors: 1. Systematic (or determinate) error, causes the mean of a data set to differ from the accepted value. 2. Random (or indeterminate) error, causes data to be scattered more or less symmetrically around a mean value. A third type of error is gross error. These differ from indeterminate and determinate errors. They usually occur only occasionally, are often large, and may cause a result to be either high or low. They are often the product of human errors. Gross errors lead to outliers, results that appear to differ markedly from all other data in a set of replicate measurements.

5B Systematic errors Systematic errors have a definite value, an assignable cause, and are of the same magnitude for replicate measurements made in the same way. They lead to bias in measurement results. There are three types of systematic errors: Instrumental errors. Method errors Personal errors

Instrumental Errors are caused by nonideal instrument behavior, by faulty calibrations, or by use under inappropriate conditions Pipets, burets, and volumetric flasks may hold or deliver volumes slightly different from those indicated by their graduations. Calibration eliminates most systematic errors of this type. Electronic instruments can be influenced by noise, temperature, ph and are also subject to systematic errors. Errors of these types usually are detectable and correctable.

Method Errors The nonideal chemical or physical behavior of the reagents and reactions on which an analysis is based often introduce systematic method errors. Such sources of nonideality include the slowness of some reactions, the incompleteness of others, the instability of some species, the lack of specificity of most reagents, and the possible occurrence of side reactions that interfere with the measurement process. Errors inherent in a method are often difficult to detect and hence, these errors are usually the most difficult to identify and correct.

Personal Errors result from the carelessness, inattention, or personal limitations of the experimenter. Many measurements require personal judgments. Examples include estimating the position of a pointer between two scale divisions, the color of a solution at the end point in a titration, or the level of a liquid with respect to a graduation in a pipet or buret. Judgments of this type are often subject to systematic, unidirectional errors. A universal source of personal error is prejudice, or bias. Number bias is another source of personal error that varies considerably from person to person. The most frequent number bias encountered in estimating the position of a needle on a scale involves a preference for the digits 0 and 5. Also common is a prejudice favoring small digits over large and even numbers over odd. Digital and computer displays on ph meters, laboratory balances, and other electronic instruments eliminate number bias because no judgment is involved in taking a reading.

5B-2 The Effect of Systematic Errors on Analytical Results Systematic errors may be either constant or proportional. Constant Errors The magnitude of a constant error stays essentially the same as the size of the quantity measured is varied. With constant errors, the absolute error is constant with sample size, but the relative error varies when the sample size is changed One way of reducing the effect of constant error is to increase the sample size until the error is acceptable. The excess of reagent needed to bring about a color change during a titration is another example of constant error. This volume, usually small, remains the same regardless of the total volume of reagent required for the titration. Again, the relative error from this source becomes more serious as the total volume decreases. One way of reducing the effect of constant error is to increase the sample size

Proportional Errors Proportional errors decrease or increase in proportion to the size of the sample. A common cause of proportional errors is the presence of interfering contaminants in the sample. For example, a widely used method for the determination of copper is based on the reaction of copper(ii) ion with potassium iodide to give iodine. The quantity of iodine is then measured and is proportional to the amount of copper. Iron(III), if present, also liberates iodine from potassium iodide. Unless steps are taken to prevent this interference, high results are observed for the percentage of copper because the iodine produced will be a measure of the copper(ii) and iron(iii) in the sample. The size of this error is fixed by the fraction of iron contamination, which is independent of the size of sample taken. If the sample size is doubled, for example, the amount of iodine liberated by both the copper and the iron contaminant is also doubled. Thus, the magnitude of the reported percentage of copper is independent of sample size. slideplayer.com/fundamentals of Analytical Chemistry, F.J. Holler, S.R.Crouch

5B-3 Detection and Elimination of Systematic (Instrumental and Personal) Errors 1. Periodic calibration of equipment is always desirable because the response of most instruments changes with time as a result of component aging, corrosion, or mistreatment. 2. Most personal errors can be minimized by careful, disciplined laboratory work. 3. It is a good habit to check instrument readings, notebook entries, and calculations systematically. 4. Errors due to limitations of the experimenter can usually be avoided by carefully choosing the analytical method or using an automated procedure. 5B-4 Detection of Systematic (Method) Errors Bias in an analytical method is particularly difficult to detect. The best way to estimate the bias of an analytical method is by analyzing Standard reference materials (SRMs).

Analysis of Standard Samples The overall composition of a synthetic standard material must closely approximate the composition of the samples to be analyzed. Great care must be taken to ensure that the concentration of analyte is known exactly. A synthetic standard may not reveal unexpected interferences so that the accuracy of determinations may not be known.

Independent Analysis - If standard samples are not available, a second independent and reliable analytical method can be used in parallel. - The independent method should differ as much as possible from the one under study. - This practice minimizes the possibility that some common factor in the sample has the same effect on both methods. - Again, a statistical test must be used to determine whether any difference is a result of random errors in the two methods or due to bias in the method under study.

Blank Determinations A blank contains the reagents and solvents used in a determination, but no analyte. Often, many of the sample constituents are added to simulate the analyte environment, which is called the sample matrix. In a blank determination, all steps of the analysis are performed on the blank material. The results are then applied as a correction to the sample measurements. Blank determinations reveal errors due to interfering contaminants from the reagents and vessels employed in the analysis. Blanks are also used to correct titration data for the volume of reagent needed to cause an indicator to change color. Variation in Sample Size As the size of a measurement increases, the effect of a constant error decreases. Thus, constant errors can often be detected by varying the sample size.

Suggested Problems 5.1, 5.3, 5.11, 5.12(a-d-f), 5.13(a-b-c)