GCMS in the Metabolic Laboratory

Similar documents
Chapter 27: Gas Chromatography

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Agilent G3212 GC-APCI Source

Chromatography. Gas Chromatography

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

2401 Gas (liquid) Chromatography

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Introduction to Capillary GC

Introduction to Capillary GC

Determination of Volatile Substances Proof of Food Adulteration

Selection of a Capillary GC Column

Introduction to GC/MS

Gas Chromatography (GC)

Benzoylecgonine in Urine by SAMHSA GC/MS

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Opiates in Urine by SAMHSA GC/MS

Agilent 5977A Series GC/MSD System

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Activity in the FID Detection Port: A Big Problem if Underestimated

Understanding Gas Chromatography

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Trajan SGE GC Columns

GAS CHROMATOGRAPHY (GC)

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Selection of a Capillary

Expectations for GC-MS Lab

Analyzing Semi-Volatiles by GC-MS

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

NORBUPRENORPHINE (Buprenorphine s Metabolite ) BUPRENORPHINE in urine by GC/MS Code GC Method of Confirmation by GC-MS

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

Spring 2010 updated March 24 Determination of Aromatics in Gasoline by Gas Chromatography- Mass Spectrometry: Comparison of Grades and Brands

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

TANDEM MASS SPECTROSCOPY

Analytical Instrumentation

TO-15 Checklist Determination of VOCs in Air by GC-MS

Training Courses. Chromatography training from the Crawford Scientific experts

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Gas Chromatography notes

ChromTech options for PAL systems

Complementary Role of GC/MS in Clinical Laboratory and Beyond

Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs)

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

A Rapid Differentiation of Pseudoephedrine and Ephedrine by Stereospecific Derivatization

Secrets of GC Column Dimensions

Principles of Gas- Chromatography (GC)

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

CH 2252 Instrumental Methods of Analysis Unit V Gas Chromatography. M. Subramanian

CHROMATOGRAPHY AND MASS SPECTROMETER

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

Gas chromatography/mass spectrometry (GC MS) Interpretation of EI spectra

GC/MS is not dead yet!!

Mass Spectrometry in MCAL

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

METHYLETHYLKETONE (M.E.K.) IN URINE BY GC/MS in head space Code GC10010

British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

The Theory of HPLC. Quantitative and Qualitative HPLC

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Disadvantage: Destructive Technique once analyzed by GC, the sample is lost

Introduction to Pharmaceutical Chemical Analysis

Chemistry Instrumental Analysis Lecture 31. Chem 4631

ACETONE IN URINE BY GC/MS Headspace Code GC10110

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Open Column Chromatography, GC, TLC, and HPLC

Agilent ESI and APCI sources: for polar to non-polar compounds

CHAPTER 6 GAS CHROMATOGRAPHY

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

VMA, HVA, 5-HIAA Urine LC-MS/MS Analysis Kit User Manual

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

brochure brief 5973Network Mass Selective Detector General Description and Configurations

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Spectroscopy and Chromatography

WADA Technical Document TD2003IDCR

METHADONE and EDDP in urine by GC-MS Code GC Method of Confirmation by GC-MS

INVESTIGATING GAS CHROMATOGRAPHY rev 8/12

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

CHEMISTRY Unit 3, Area of Study 1: Chemical Analysis

Introduction. Chapter 1. Learning Objectives

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

The Claviature of Gas Analysis

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

GC-CI-MS analysis of TMS derivatives

Chromatography and Functional Group Analysis

Chemistry Chapter 3. Stoichiometry. (three sections for this chapter)

Determination of Elemental Sulfur in Explosives and. Explosive Residues by Gas Chromatography-Mass Spectrometry. Kimberly S.

Using a mini-gas Chromatograph (GC): Identifying Unknown Compounds

Agilent G2350A Atomic Emission Detector (AED)

Gas Chromatography. Introduction

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Optimizing Conditions for Volatiles Analysis

Transcription:

GCMS in the Metabolic Laboratory Heather Wheatley University Hospital of Wales Cardiff MetBioNet BMS Training Group Workshop : Tackling all techniques April 2015

Fundamentals of chromatography Fundamentals: lab technique for the separation of a mixture of compounds Mixture of analytes dissolved in a fluid called the mobile phase travel through a structure holding a material called the stationary phase Separation is based on differential partitioning between the mobile and stationary phases various constituents travelling at different speeds- varying retention times

Topics for discussion Principles of GC-MS ( EI ) Maintenance/Troubleshooting Applications of GC-MS in Clinical Biochemistry Cases

Schematic of a GCMS

GC Insulated oven with programmable temperature control Autosampler Heater inlet for split/ splitless injection Column: fused silica capillary with chemically bonded phase eg HP5 Transfer line to detector: MS

MS A MS consists of: a source, an analyser and a detector A mass spectrometer produces charged particles ( ions) ; the MS then uses electric and magnetic fields to easure the ass eight of the harged parti les MS is used in environmental work, analysis of petroleum products, forensic medicine, toxicology and analysis of biological materials and now proteomics.

Schematic of a GCMS

Capillary columns

Schematic of a capillary column

Quadropole

What does the mass tell us? H20 2 x H ( 2 x 1 amu) 1 x O (1 x 16 amu) H2O = 18 u Water vapour is introduced into the ion source of the MS ( under vacuum). Shoot a beam of electrons through the water vapour, some of the electrons will hit water molecules and knock off an electron. Loss of a negatively charged electron, the water will be left with a net positive charge. H20 + 1 (fast) electron [H20}+ + 2electrons

Mass spectra For water, the only possible fragments will be [OH]+, O+ and H+ The mass spectrum will show peaks at the masses of 1,16,17 and 18.

Modes of operation Full scan considers all peaks in a sample and their individual spectrums Selective Ion Monitoring ( SIM) - only monitors selected ions associated with a specific substance

Software oft are that a o trol te perature gradie t progra ed ethods ith rete tio ti e lo ki g, olle t full s a large data files, store the, allo retrospe ti e a alysis Acquisition of MS data, processing of MS data. Full scan: across mass range 50-500. Scan speeds increasing over time Fragmentation patter ; stru ture a d fi gerpri t SIM Selective ion monitoring screening out background concentrating on a particular ion for quantification and a second conffirmatory ion Computer programs, such as those that search libraries of mass spectra for the best at h a e used to i terpret a ass spe tru Li rary ear h eg NI T, AMDI et Automatic labelling of peaks: deconvolution software. Shimadzu, Agilent ( Masshunter)

Modes of operation Full scan considers all peaks in a sample and their individual spectrums Selective Ion Monitoring ( SIM) - only monitors selected ions associated with a specific substance

Analysis of Physiological fluids Liquid/liquid extraction ( extraction proportional to creatinine) Addition of internal standards SPE Preparation of volatile derivatives for GC Metabolic profiling

Preparation of derivatives High polarity, low volatility, and thermal instability of most organic compounds makes it essential to convert them into stable volatile derivatives Nature of the derivative selected obviously affects the mol wt and mass spectra TMS (trimethylsilyl derivatives) - commercial preparations widely available eg BSTFA with 1% TMCS and with some pyridine Methyl esters ( esterification of fatty acids)

TMS derivatives TMS derivatives widely used in organic acid analysis Easy to prepare: low polarity/high volatility High reactivity to water: dry extracts required for preparation and stable storage In TMS spectra, the base peak is almost invariably m/z 73, in compounds with two or more TMS groups the ion m/z 147 Molecular ions invariably small, with an ion at M-15 ( loss of CH3). Indicator of molecular weight.

Maintenance A preventative maintenance contract covering the GC, MS & vacuum system should be in place in order to ensure optimal operation of the instrument. Most day-to-day maintenance is directed towards the injector & injection port. Need to ensure inertness & an air-tight seal. Maintenance schedule depends on workload & sample quality. Septum replacement after approximately 150 injections. Replace liner usually silanized to remove active sites in the glass. Clean the autosampler syringe with (DCM/acetone/methanol) regularly & change the on-board wash solvents regularly Observe the column manufacturers specifications column life will be shortened & performance compromised if the oven temperature is too high.

Maintenance Logbook Record of maintenance Eg inlet: septum, liner, gold seal replacement Instrument tuning : see tune reports Replacing columns Cleaning the ion source, replacing filaments Operators/ assay sequence lists/

Gastight system Do not over-tighten fittings. Only ½ turn past finger tight is required, otherwise the ferrule will fail & leak. Routine MS maintenance: Perform a leak check before each run. Look for the water (18 amu), nitrogen (28 amu), and oxygen (32 amu) peaks. If present, there probably is a leak around the column-to-source seal. Tune MS before each use. Maintain a supply of spare parts and keep a dedicated tool box to hand. Be proactive with instrument maintenance develop & follow a schedule. Record all maintenance, scheduled & unscheduled in a log book.

Maintenance A preventative maintenance contract covering the GC, MS & vacuum system should be in place in order to ensure optimal operation of the instrument. Most day-to-day maintenance is directed towards the injector & injection port. Need to ensure inertness & an air-tight seal. Maintenance schedule depends on workload & sample quality. Septum replacement after approximately 150 injections. Replace liner usually silanized to remove active sites in the glass. Clean the autosampler syringe with (DCM/acetone/methanol) regularly & change the on-board wash solvents regularly Observe the column manufacturers specifications column life will be shortened & performance compromised if the oven temperature is too high.

Applications of GCMS Urine organic acids Plasma/Urine MMA quantitation Very long chain fatty acids (peroxisomal disorders) Steroids and their metabolites

Cases: organic acid disorders Methylmalonic aciduria Isovaleric aciduria MCAD Beta ketothiolase deficiency MSUD

Isovaleric aciduria

Methylmalonic acidura

MSUD

Mass spectrum

Library matching

Cases: Very Long Chain Fatty Acids Peroxisomal disorders:eg Zellwegers ALD adrenaleukodystrophy C26 C22/24 C24/C26 Phytanate ( Refsums disease) Pristanic acid

VLCFA using SIM

Quantitation of MMA- stable isotope dilution B12 deficient patients Cobalamin disorders B12 responsive Methylmalonicacidaemia

Urine steroid profiles Viapath @ Kings (Dr. Norman Taylor) Cortisol and cortisone metabolites Androgens and androgen metabolites (age related reference ranges).

Tackling techniques Thank You. Questions?

Logical troubleshooting: Gain information from the GCMS system i. define the problem ii. check the front panels iii. refer to the log book, recent maintenance etc Isolate the pro le.

Tuning and troubleshooting: Standard spectra autotune be aware of common contaminant ions Status checks Vacuum status Diagnostics Customer care lines: Agilent Remote adviser: technical help over telephone. Engineer assistance

Troubleshooting : tips System considerations: Gases: regulators, pipeline maintenance Traps Column :score cleanly, break- inspect for jagged edges or burrs! Use the correct ferrules for the job! Do NOT overtighten! Injection port: septum,liner/o-ring/gold seal/washer Sample? contamination. Screen your sample first.sample clean up. Inject the smallest volume possible

Troubleshooting : tips continued Vacuum pump oil, pump fan MSD ion source : filaments Tool box, carry spares: liners, septa, seals, columns, ferrules etc Discuss with knowledgable colleagues.. learning curve