KESTREL. April 26, Mr. Stephen Evans Maine Yankee 321 Old Ferry Road Wiscasset, Maine 04578

Similar documents
Maine DEP DRO. MY05TP220A(0-0.5) MY05TP222A(0-0.5) FD MY05TP223A(0-0.5) FD MY05TP220A (EB) EB-Equipment Rinsate Blank FD- Field Duplicate Samples

Method 8270C PAH. FD- Field Duplicate Samples

alscience nvironmental aboratories, Inc.

American Environmental Testing Laboratory Inc.

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

ANALYTICAL REPORT. Attn: Richard Boelter

APPENDIX II QUALITY CONTROL SUMMARY TABLES

CSO/SWO Data Validation Reports June 20, 2014

Qualification Code Reference Table Cont.

December 30, Laboratory Report This Page is to be Stamped Introduction: This report package contains total of 5 pages divided into 3 sections:

Review and Reporting of Chemical of Concern (COC) Concentration Data Under the TRRP Rule (30 TAC 350)

LOUISVILLE CHEMISTRY GUIDELINE (LCG)

TETRA TECH, INC. December 8, Lynn Nakashima Berkeley Regional Office 700 Heinz Avenue, Suite 200C Berkeley, California 94710

OBJECTIVE DATA PACKAGE DELIVERABLES

KSA Environmental Laboratory Inc.

LABORATORY REPORT #P (Air) SAMPLE DATE: AUGUST 7-9, 2017

INTRODUCTION. Scope and Applicability

KSA Environmental Laboratory Inc.

TCEQ Regulatory Guidance Remediation Division RG-366/TRRP-13 December 2002

APPENDIX B QUALITY ASSURANCE PROJECT PLAN

Enclosed is a copy of your laboratory report for test samples received by our laboratory on Thursday, February 25, 2010.

ACZ Laboratories, Inc Downhill Drive Steamboat Springs, CO (800)

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

~~LABORATORY DATA CONSULTANTS, INC.

Soil Sampling Results Former Truck Maintenance Garage

Chain of Custody and Supporting Documentation

Laboratory Analytical Data

Revisions to Text Based on Completion of Tier III Validation. Section 1. Section 4.2

DHL Analytical received 2 sample(s) on 6/18/2009 for the analyses presented in the following report.

Appendix B RFI Sampling Program Summary (appears on CD only)

ANALYTICAL REPORT. Job Number: Job Description: Transform Complete

ANALYTICAL REPORT. Attn: Thomas W Hensel

STANDARD OPERATING PROCEDURES

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

If you have any questions concerning this report, please feel free to contact me. REPORT OF LABORATORY ANALYSIS

ANALYTICAL REPORT. Job Number: Job Description: Old Douglas Harbor. For: PND Engineers, Inc West 36th Ave. Anchorage, AK 99503

Verification and Review of Data for Chlorinated Dioxins, Furans and PCB Congeners by Isotope Dilution HRGC/ HRMS

USEPA CONTRACT LABORATORY PROGRAM NATIONAL FUNCTIONAL GUIDELINES FOR ORGANIC DATA REVIEW

Some analyses have been subcontracted outside of the Pace Network. The subcontracted laboratory report has been attached.

PROJECT ID: W09341 LABORATORY REPORT NUMBER: L

If you have any questions concerning this report, please feel free to contact me. REPORT OF LABORATORY ANALYSIS

DRAFT QUALITY ASSURANCE PROJECT PLAN

CERTIFICATE OF ANALYSIS

ATTACHMENT A WEAVER BOTTOMS SEDIMENT BASIN MAINTENANCE PROJECT PROJECT REPORT SUMMARY (APRIL 7, 2014)

Measurement Uncertainty: A practical guide to understanding what your results really mean.

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

One Stop DIY Shop. PO Box 104 New Germany, MN Carbonyl Assay. Samples Received 09/09/2014. Analysis Report ( )

Forebay Confirmatory Sediment Sampling Results

LABORATORY DATA REVIEW CHECKLIST

Imagine the result Sediment Sampling Plan. 1½-Mile Reach of the Housatonic River. General Electric Company Pittsfield, Massachusetts

ANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident

APPENDIX D Laboratory Analytical Reports

January 19, Dear Mr. Nightingale:

GLM & Associates. February 9, 2018

Data Glossary. Acceptance criteria - specific limits placed on characteristics of an item, process, or service defined in requirements documents.

ANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident


QUALITY ASSURANCE PROJECT PLAN PHASE I EMORY RIVER DREDGING TENNESSEE VALLEY AUTHORITY KINGSTON FOSSIL PLANT ASH RECOVERY PROJECT

Table of Contents I. PURPOSE AND SCOPE:... 3 II. AUTHORITY:... 3 III. REFERENCE:... 3 IV. RESPONSIBILITY:... 3 V. POLICY:... 3 VI. PROCEDURE:...

PCB Soil Field Sampling Plan

Is the laboratory s pledge or declaration of the quality of the results produced. to produce data compliant with the Safe Drinking Water Act (SDWA)

Introduction. The following definitions may help you better understand the components of the data report.

Laboratory ID. Laboratory Name. Analyst(s) Auditor. Date(s) of Audit. Type of Audit Initial Biennial Special ELCP TNI/NELAP.

EDD FIELD DESCRIPTIONS

For Routine Level Volatile Organic Compounds (VOC), Gasoline Range Organics (GRO) and Total Petroleum Hydrocarbons (TPH) Data Validation (pg.

USEPA CONTRACT LABORATORY PROGRAM NATIONAL FUNCTIONAL GUIDELINES FOR LOW CONCENTRATION ORGANIC DATA REVIEW

Inside the Black Box of an Environmental Testing Laboratory Basic Analytical Procedures

ANALYTICAL REPORT. Results relate only to the items tested and the sample(s) as received by the laboratory. Page 1 of 5

QUALITY CONTROL CRITERIA FOR CHEMISTRY EXCEPT RADIOCHEMISTRY.

Laboratory 101: A Guide to Understanding your Testing Laboratory

LABORATORY DATA CONSULTANTS, INC Loker Ave. West, Suite 220, Carlsbad, CA Bus: Fax:

~ ALG ANALYTICAL LABORATORY GROUP

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

How Well Do You Know Lab Reports? Making Sense Out of Seemingly Simple Lab Reports

Certificate of Analysis FINAL REPORT

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

QA/QC in the Wastewater Laboratory. Steve Roberts Ohio EPA Division of Environmental Services 05/11/2016

~~LABORATORY DATA CONSULTANTS, INC.

ALPHA ANALYTICAL LABORATORIES. Eight Walkup Drive Westborough, Massachusetts (508)

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM

DATA ITEM DESCRIPTION

November 23, Mr. Shawn Liddle District Clerk Albion Central School District 324 East Avenue Albion, NY 14411

TNI V1M Standard Update Guidance on Detection and Quantitation

Quick Nic Juice. 122 Indian Springs Drive #5 Sandwich, IL Carbonyl Assay Samples Received 3/16/2015. Analysis Report ( )

The following report includes the data for the above referenced project for sample(s) received on 5/15/2017 at Air Toxics Ltd.

~WJulu LABORATORY DATA CONSULTANTS, INC.

Analytical Report

QAM-Q-101 Laboratory Quality Control

Results of the EPA Method 1631 Validation Study

STANDARD OPERATING PROCEDURES

PCB Congener Analysis of XAD-2 Resins and GFF Filters Using GC/ECD

ALLOWAY METHOD OUTLINE

RIGHT SOLUTIONS RIGHT PARTNER

Fundamentals of the Method for Analysis of Dioxins/Furans in Method 0010/0023A Train Samples

Radiochemistry Webinars Data Verification and Validation

ANALYTICAL RESULTS. Project: Mayflower, AR Pipeline Incident

Drake Petroleum Company, Inc. Accutest Job Number: JB Total number of pages in report:

Transcription:

KESTREL ENVIRONMENTAL TECHNOLOGIES, INC. Mr. Stephen Evans Maine Yankee 321 Old Ferry Road Wiscasset, Maine 04578 RE: Project No.: Maine Yankee Soil Samples Lab Name: Katahdin Analytical Services, Westbrook, Maine Site Name: Maine Yankee Nuclear Power Plant, Wiscasset Maine Samples Collected: 3/23/05 5 soil samples 1 aqueous equipment rinsate blank Data package: WV1271 Method 8082 Samples Collected: (Client IDs) MY05TP390(2.0-2.25) MY05TP392(3.0-3.25)FD MY05TP394(4.0-4.25) MY05TP390(EB) MY05TP391(3.0-3.25) MY05TP393(3.0-3.25)FD EB-Equipment Rinsate Blank FD- Field Duplicate Samples Dear Mr. Evans: A Tier II data validation was performed on the polychlorinated biphenyls (PCBs) analytical data for samples collected at the Maine Yankee Nuclear Power Plant, Wiscasset Maine. The laboratory, Katahdin Analytical Services, Westbrook Maine, prepared and analyzed the samples in accordance with US EPA SW-846 method 8082. Soil samples were extracted following US EPA SW-846 method 3550 (sonication). The QAPP approved extraction method for soil PCB samples is 3540 (Soxhlet). Aqueous samples were extracted following USEPA SW-846 method 3510 (separatory funnel). The data validation was conducted in accordance with Region I, EPA-New England Data Validation Functional Guidelines (12/96), the QAPP for Maine Yankee Decommissioning Project, (rev01), Laboratory Data Validation Functional Guidelines for Evaluating Pesticides/PCBs Analyses (05/85), and in conjunction with the individual methods and the laboratory established criteria. The following items were validated: Chain of Custody Documents * Sample Log-in Documents * Preservation and Technical Holding Times * Initial Calibrations * Continuing Calibrations * Laboratory and Field Blank Analyses *

Data Validation Report (continued) Page 2 Matrix Spike/Matrix Spike Duplicate Results * Laboratory/Field Duplicate Results * Laboratory Control Samples (Blank Spikes) System Monitoring Compounds (Surrogate Recoveries) * PE Samples/Accuracy Check (NA) Compound Quantitation and Reported Quantitation Limits (NA) * - All Criteria met The following information was used to generate the Data Validation Memorandum: Attachments: Table I Recommendation Summary Table- summarizes validation recommendations: 8082. Table II Overall Evaluation of Data- summarizes site DQOs and potential usability issues: 8082. Data summary tables to be provided in an electronic format. Overall Evaluation of Data and Potential Usability Issues Data Use- To determine the nature and extent of potential contamination, to identify any potential contaminant source areas requiring further evaluation, to support any remedial activities that may be necessary to minimize potential risk to human health and environment. Accuracy and precision acceptance criteria are specified in the QAPP for Maine Yankee Decommissioning Project, (rev01). The laboratory used method 3550 (sonication) for the extraction of the soil samples. Method 3540 (Soxhlet) is the QAPP approved extraction method for soil PCB samples. The laboratory reported all PCB results for the samples in this data package as non-detected (U). No data were qualified due to QC results reviewed for this data package. Note that the laboratory did not use QAPP acceptance criteria to flag the data. The validation was performed using QAPP acceptance criteria. Chain of Custody Documents The sampling chain of custody documents were properly signed and dated. Internal custody documents were not submitted. Review of internal custody documents is not part of a Tier II validation for this project. The field sampler hand-delivered the samples to the laboratory. Custody seals were not present.

Data Validation Report (continued) Page 3 Sample Log-in Documents Laboratory Sample Receipt Condition Reports (SRCR) indicate that all samples were received in good condition. The cooler temperature was 1.3 o C. There were no deviations indicated on the SRCRs. The validation memo is consistent with the laboratory data package sample IDs. Preservation and Technical Holding Times All samples were properly preserved. All reported samples were analyzed within holding times. Initial Calibration All initial calibration criteria were within the method calibration acceptance criteria. The laboratory analyzed a 6 point standard curve for all aroclors, except Aroclor-1221 and Aroclor- 1232. Results for the 6 point standard curves are reported from the 2 nd order regression. All correlation coefficients exceeded 0.995. The low standard for the curves is at the reported method PQL (Practical Quantitation Limit) and the project quantitation limit. The laboratory did include the origin in the calibration curve. US EPA SW846 calibration procedures (section 8000) state "do not include the origin (0,0) as a calibration point." No results are qualified based upon the initial calibration results. Continuing Calibration All continuing calibration criteria were met on at least one of the reported channels for all compounds. Note that continuing calibration compound % differences may be > 15% on one column and < 15% on the other column. No data were qualified due to continuing calibration results. Laboratory and Field Blank Analyses No positive PCB results were detected in the laboratory preparation blanks. There were no positive PCB results detected for equipment blank sample MY05TP390(EB). No data are qualified due to contamination in laboratory or field blank samples. Matrix Spike/Matrix Spike Duplicate Results MY05TP392(3.0-3.25) is the MS/MSD reported for this data package. The QAPP acceptance criteria for recovery are 76-137% for Aroclor-1016 and 75-132% for Aroclor-1260. The QAPP acceptance criteria for %RPD is <50%. All results meet QAPP acceptance criteria. No data are qualified due to the MS/MSD results. Field/Laboratory Duplicates

Data Validation Report (continued) Page 4 Samples MY05TP392(3.0-3.25) and MY05TP393(3.0-3.25) are reported as the field duplicates for this data package. The laboratory reported all field sample results as non-detected (U). All acceptance criteria are met. No data are qualified due to field duplicate results. No laboratory duplicate sample was analyzed. Laboratory Control Sample Results The LCS recoveries were evaluated according to the QAPP criteria. One LCS was reported for the soil samples and one LCS/LCSD pair was reported for the aqueous sample. The QAPP criteria for recovery for soils are 76-137% for Aroclor-1016 and 75-132% for Aroclor-1260. The QAPP criteria for recovery for aqueous samples are 67-137% for Aroclor-1016 and 69-133% for Aroclor-1260. All LCS results met the recovery acceptance criteria. The %RPD acceptance criteria for aqueous samples are <30%. The LCS/LCSD results met the laboratory acceptance criteria for precision. Precision for soil samples was evaluated from MS/MSD results. No field sample results are qualified due to LCS or LCSD results. System Monitoring Compounds (Surrogate Recoveries) QAPP acceptance criteria for soils are 36-118% for TCMX and 34-127% for DCB. All surrogate recoveries for soil samples were within QAPP acceptance criteria. QAPP acceptance criteria for aqueous samples are 51-113% for TCMX and 51-118% for DCB. All surrogate recoveries for aqueous field samples were within QAPP acceptance criteria. No field sample results were qualified due to surrogate recoveries. It should be noted that the surrogate recoveries for TCMX for the aqueous laboratory blank was below acceptance criteria. PE/Accuracy Check Performance evaluation results were not submitted. The LCSs were from an independent, referenced source.

Data Validation Report (continued) Page 5 Compound Quantitation and Reported Quantitation Limits All positive PCB results are confirmed by GC analyses on a 2 nd column of different polarity. The acceptance criteria is < 40% difference. No positive PCB results were reported in this data package. Results were reported to the laboratory PQLs and adjusted for sample mass, dilution factor, and total solids. The low point of the calibration curve is at the laboratory s reporting limit. Note that the laboratory reports the higher of the two positive results. US EPA SW-846 GC methods recommend that the higher result be reported. Please contact Kestrel Environmental Technologies, Inc. with any questions regarding this information. Sincerely, Kestrel Environmental Technologies, Inc. Deborah Smith Validator Attachments: Table I: Validation Recommendation Summaries Table II: Overall Evaluation of Data for 8082

Data Validation Report (continued) Page 6 Maine Yankee Samples WV1271 Table I-Method 8082 PCBs Recommendation Summary Recommendation Summary Sample ID Matrix Qualifier MY05TP390(2.0-2.25) Soil A MY05TP391(3.0-3.25) Soil A MY05TP392(3.0-3.25)FD Soil A MY05TP393(3.0-3.25)FD Soil A MY05TP394(4.0-4.25) Soil A MY05TP390(EB) Aqueous A A - Accept all data.

Data Validation Report (continued) Page 7 TABLE II EPA NE-Data Validation Worksheet Overall Evaluation of Data WV1271 Katahdin Analytical Services DQOs 8082 Sampling/ Measurement Error Analytical Analytical Sampling Sampling Variability Potential Usability Issues To determine the nature and extent of potential contamination, to identify any potential contaminant source areas requiring further evaluation, to support any remedial activities that may be necessary to minimize potential risk to human health and environment. Soil samples extracted by 3550. Aqueous samples extracted by 3510. PCB 8082 A *not assessed Accept all data. Validator: Date: