Certificate of Analysis

Similar documents
Certificate. Standard Reference Material Near-Infrared Wavelength/Wavenumber Reflection Standard. ), 1.30 % samarium oxide (Sm 2

HPLC Column Classification

Stability of Silica-Based, Monofunctional C 18 Bonded- Phase Column Packing for HPLC at High ph

Certificate of Analysis

Certificate of analysis Certified reference material code: CRM-00-GTX1&4

Certificate of Analysis

Comparison Guide to C18 Reversed Phase HPLC Columns

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency


Hypersil BDS Columns TG 01-05

Certified Reference Material - Certificate of Analysis Methylone, Primary Standard

HPLC Reverse Phase Test Mix #1

Certificate of analysis Certified reference material code: CRM-00-NEO

Certificate of Analysis Standard Reference Material 2692c

penta-hilic UHPLC COLUMNS

Certified Reference Material - Certificate of Analysis

A C18 Silica Column With Exceptional Temperature and ph Stability

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Certificate of Analysis

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Metolachlor ESA Sodium Salt Standard

Certificate of Analysis

High Performance Liquid Chromatography

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

Certified BTEX in Unleaded Gas Composite

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Impact of Instrument Dispersion on Performance of HPLC Capillary Columns

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Certified Reference Material - Certificate of Analysis

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

penta-hilic UHPLC COLUMNS

Certificate of Analysis

C18 Column. Care & Use Sheet

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Certificate of Analysis

Basic Principles for Purification Using Supercritical Fluid Chromatography

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Revision Bulletin 27 Jan Feb 2017 Non-Botanical Dietary Supplements Compliance

MEDROXYPROGESTERONE INJECTION

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

LUMEFANTRINUM LUMEFANTRINE

Introduction. Chapter 1. Learning Objectives

Revision Bulletin 29 Dec Jan 2018 Non-Botanical Dietary Supplements Compliance

High Pressure/Performance Liquid Chromatography (HPLC)

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

Tri-n-propyltin Chloride Mixture

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Certificate of Analysis

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method

The Uncertainty of Reference Standards

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

8. Methods in Developing Mobile Phase Condition for C18 Column

Certificate of Analysis

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

USP Class 1 Residual Solvent Mixture

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

OBSERVATIONS ON THE WETTING OF REVERSED-PHASE HPLC PACKINGS

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Delta-9-THC Standard. Catalog # Lot # A082745

for Acclaim Mixed-Mode HILIC-1 Column

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

A Highly Stable Alkyl Amide Silica-Based Column Packing for Reversed-Phase HPLC of Polar and Ionizable Compounds

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Impact factor: 3.958/ICV: 4.10 ISSN:

Certificate of Analysis

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Introduction to Pharmaceutical Chemical Analysis

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

LC and LC/MS Column Selection Flow Chart

Comparison of different aqueous mobile phase HPLC techniques

ANALYSIS OF BASIC COMPOUNDS

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

Appendix II- Bioanalytical Method Development and Validation

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

PARTICLE SIZE ANALYSIS OF GOLD NANOPARTICLES

Minimizing Solvent Impact on Purification of Nitrogencontaining


Aldehydes/Ketones DNPH Standard

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number:

Chemistry Instrumental Analysis Lecture 28. Chem 4631

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

ASPIRIN (ACETYLSALICYLIC ACID) CERTIFIED REFERENCE MATERIAL

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Certificate of Analysis

Chapter content. Reference

Reversed Phase Solvents

Transcription:

National Institute of Standards & Technology Certificate of Analysis Standard Reference Material 870 Column Performance Test Mixture for Liquid Chromatography This Standard Reference Material (SRM) is a mixture of five organic compounds in methanol and is intended for use in characterizing general aspects of liquid chromatographic (LC) column performance, including efficiency, void volume, methylene selectivity, retentiveness, and activity toward chelators and organic bases. Other possible uses include (1) column classification to aid column selection during method development, (2) as a control material for monitoring LC column performance over time, and (3) in quality control for column manufacturing. SRM 870 consists of a mixture of the following five organic compounds in methanol:,,,, and (added as hydrochloride; see Figure 1 for structures). A unit of SRM 870 consists of five ampoules each containing approximately 1.1 ml of the mixture. Certified Mass Fraction Values: The measurand is the certified mass fraction values for,, ethyl benzene,, and hydrochloride are provided in Table 1. A NIST certified value is a value for which NIST has the highest confidence in its accuracy in that all known or suspected sources of bias have been investigated or taken into account [1]. Values were derived from the combination of results from liquid chromatography with ultraviolet absorbance detection (LC-UV) and from the gravimetric preparation of the solution. The associated uncertainties are expanded uncertainties at the 95 % level of confidence. The expanded uncertainty is calculated as U = kuc, where uc incorporates the observed difference between the results from the methods and their respective uncertainties, as well as uncertainty related to purity correction, consistent with the ISO/JCGM Guide and its Supplement 1, and k is a coverage factor corresponding to approximately 95 % confidence for each analyte [2 4]. Values are reported on an as-received basis in mass fraction units. Metrological traceability is to the derived SI unit for mass fraction (expressed as milligrams per kilogram). Information Values for Detection Response: Relative detection responses of the components are listed in Table 2. An information value is a value that may be of interest to the SRM user, but insufficient information is available to assess the uncertainty associated with the value or only a limited number of analyses were performed [1]. Information values cannot be used to establish metrological traceability. Expiration of Certification: The certification of SRM 870 is valid, within the measurement uncertainty specified, until 30 September 2025, provided the SRM is handled and stored in accordance with the instructions given in this certificate (see Instructions for Handling, Storage, and Use ). The certification is nullified if the SRM is damaged, contaminated, or otherwise modified. Maintenance of SRM Certification: NIST will monitor this SRM over the period of its certification. If substantive technical changes occur that affect the certification before the expiration of this certificate, NIST will notify the purchaser. Registration (see attached sheet or register online) will facilitate notification. Preparation and analytical determinations were carried out by L.C. Sander and B.A. Benner, Jr. of the NIST Chemical Sciences Division. Support aspects involved in the issuance of this SRM were coordinated through the NIST Office of Reference Materials. Gaithersburg, MD 20899 Certificate Issue Date: 07 July 2016 Certificate Revision History on Last Page Carlos A. Gonzalez, Chief Chemical Sciences Division Steven J. Choquette, Acting Director Office of Reference Materials SRM 870 Page 1 of 9

Analyses for certification were performed by the following: G. Boone, Varian, Inc. (Harbor City, CA); J. DeStefano, Hewlett-Packard Co. (Newport, DE); K. Harrison, The Separations Group, Inc. (Hesperia, CA); R. Henry, Keystone Scientific, Inc. (Bellefonte, PA); J. Higgins, Higgins Analytical (Mountain View, CA); B. Hornbake, Macherey-Nagel (Easton, PA); J. Lamb, Hypersil, Astmoor (Runcorn, England); U. Neue, Waters (Milford, MA); M. Przybyciel, ES Industries (Marlton, NJ); M. Woelk, MetaChem Technologies, Inc. (Torrance, CA); V. Yearick, Supelco, Inc. (Bellefonte, PA); C. Young, R. Weigand, Alltech Associates, Inc. (Deerfield, IL); and K. Zimmerma n, Mac-Mod Analytical, Inc. (Chadds Ford, PA). INSTRUCTIONS FOR HANDLING, STORAGE, AND USE Storage: Sealed ampoules, as received, should be stored in the dark at temperatures between 10 C to 30 C. Chromatographic Conditions: This test mixture is intended primarily for the characterization of C18 columns used in reversed-phase liquid chromatography. To compare columns on the same basis, the user should evaluate column performance by separating the five components of the mixture isocratically under the following conditions: mobile phase 80 % methanol and 20 % aqueous buffer (volume fractions), flow rate 1 ml/min, column temperature 23 C, injection volume 1 µl to 2 µl. The recommended buffer composition is 20 mmol/l potassium phosphate adjusted to ph 7.0 (final phosphate concentration in the mixed methanol/buffer mobile phase is 4 mmol/l). This buffer can be prepared by mixing 20 mmol/l monobasic potassium phosphate (KH2PO4) and 20 mmol/l dibasic potassium phosphate (K2HPO4) solutions to obtain the desired ph 7.0 solution, as indicated by a ph meter. Because changes in absolute retention, selectivity, and peak shape can occur with changes in temperature and composition, these conditions should be used for all column evaluations. Figure 1 shows the structures and properties evaluated for components in SRM 870. PREPARATION AND ANALYSIS (1) A methanol solution of,,,, and hydrochloride (see Table 2 for sources) was prepared gravimetrically from individual compounds. The solution was stirred for approximately 13 h and then aliquoted into 2-mL amber glass ampoules, which were purged with argon prior to addition of the solution. Levels of the constituents were determined by liquid chromatography with absorbance detection at 210 nm, using a 25 cm 4.6 mm ACE 5 C18 column (Mac-Mod Analytical Inc., Chadds Ford, PA) and with the conditions listed above (column temperature was maintained at 30 C to improve the resolution of and for purposes of quantitation). Table 1. Certified Mass Fraction Values for Constituents of SRM 870 Compound Mass Fraction Coverage Factor, k (mg/kg) Uracil 27.1 ± 1.3 2 Toluene 1430 ± 40 2 Ethyl Benzene 1730 ± 40 2 Quinizarin 90.8 ± 2.5 2 Amitriptyline HCl 2740 ± 150 2 (1) Certain commercial equipment, instruments or materials are identified in this certificate to adequately specify the experimental procedure. Such identification does not imply recommendation or endorsement by the National Institute of Standards and Technology, nor does it imply that the materials or equipment identified are necessarily the best available for the purpose. SRM 870 Page 2 of 9

Figure 1. Structures and Properties Evaluated for Components in SRM 870 SRM 870 Page 3 of 9

Information Values for Detection Response: The values listed in Table 2 are provided for information only and may be of use as an aid in peak identification. These values are not intended for use in quantitation. Table 2. Sources and Information Values for Detection Responses of Components in SRM 870 Component CAS Number (a) Source Lot Relative Area, 254 nm Relative Area, 210 nm Relative Area, 480 nm Methanol 67-56-1 J.T. Baker L30330 Uracil 66-22-8 Aldrich MS15011BS 0.02 0.00 Toluene 108-88-3 Burdick and AH700 0.02 0.18 Jackson Ethyl benzene 100-41-4 Aldrich PS10785MS 0.03 0.20 Quinizarin 81-64-1 Aldrich 03116HS 0.10 0.01 1.00 Amitriptyline HCl 549-18-8 Sigma 48H0468 0.83 0.61 (a) Chemical Abstracts Service INTERPRETATION OF RESULTS Separations of the test mixture are illustrated in Figures 2A through 2F for several different C18 columns. These chromatograms are examples of possible types of retention behavior. The most typical elution order is shown in Figure 2C. Uracil elutes near the void volume, followed by and. The elution order for and varies with column properties. Quinizarin may elute before, after, or coelute with. In most instances, peak identification can be made on the basis of elution order (,, ) and detector response (, ). Relative peak areas are dependent on the detection wavelength (see Table 2). Quinizarin has significant absorbance at 480 nm, and separations of SRM 870 carried out at this wavelength are selective for this single component. Conversely, exhibits reduced absorbance at 210 nm, permitting measurement of in the presence of. A comparison of separations carried out with detection at 210 nm, 254 nm, and 480 nm is provided in Figure 3. In the event of coelution of and, data for each component can often be obtained by selective detection at 210 nm and 480 nm (see Table 2). At 210 nm, the area of is approximately 2 % of the area of, making the interference to small. The retention behavior of reversed-phase LC columns often differs in a variety of ways. The components in this test mixture were selected as indicators of several types of chromatographic properties. The determination of peak width (efficiency, theoretical plates), peak asymmetry (As), absolute retention (k ), and selectivity factor (α, i.e., relative retention k 1/ k 2) for these components may provide useful measures of these properties [5]. Uracil: This component is commonly used as an indicator of the void volume (unretained volume) in an LC column. The measurement of void volume is somewhat controversial; however, provides an acceptable approximation of this property. Toluene/Ethyl benzene: The retention of these compounds can be considered to result primarily from solvophobic interactions. The selectivity factor αe/t is the k ratio of and, and this value has been used to characterize differences among C18 and C8 columns. Absolute retention of a nonpolar component such as ethyl benzene provides a measure of column retentiveness (column strength). Toluene and/or are also useful markers for calculation of column efficiency (theoretical plates, N). SRM 870 Page 4 of 9

A low silanol activity low metal activity embedded polar functionality 0 1 2 3 4 5 B C D low silanol activity low metal activity low silanol activity low metal activity moderate silanol activity high metal activity relative response 0 1 2 3 4 5 6 7 0 2 4 6 8 10 + + 0 5 10 15 20 E high silanol activity low metal activity F high silanol activity high metal activity 0 5 10 15 20 0 5 10 15 retention time (minutes) Figure 2. Examples of Separations of SRM 870 on Commercial C18 Columns Quinizarin: Quinizarin (1,4-dihydroxyanthraquinone) is a metal chelating reagent (see Figure 1). The retention behavior of this component is expected to be indicative of the presence or absence of metals in the chromatographic system. Columns demonstrate one of two types of retention behavior. Low activity toward chelating reagents is indicated by symmetric peak shape, and high activity toward chelating reagents is indicated by tailing, asymmetric peak shape. Quinizarin typically elutes after and before. It is interesting to note that for columns known to contain certain embedded polar functional groups, elutes last, with good peak symmetry. Peak asymmetry is not strongly correlated with retention for. SRM 870 Page 5 of 9

250 100 254 nm 0 0 2 4 6 8 10 12 detector response (mv) 1200 500 0 210 nm 0 2 4 6 8 10 12 retention time (minutes) Figure 3. Separations of SRM 870 with Detection at 254 nm, 210 nm, and 480 nm Amitriptyline: Amitriptyline is a basic (pka = 9.4) pharmaceutical drug (tricyclic antidepressant) commonly used by column manufacturers for column characterization. Elution of organic bases with severe peak tailing is often associated with high silanol activity; however, the elution of such compounds with symmetrical peak shape is considered indicative of column deactivation. Because peak tailing is the most objectionable property associated with silanol activity, As is an appropriate measure of this property. Peak asymmetry is not strongly correlated with retention for. DISCUSSION Selection of the components in SRM 870 was based on published testing protocols [6,7] and commercial column literature [8]. An effort was made to provide a simple, easy-to-evaluate test with a limited number of components. Component concentrations were adjusted to facilitate identification. This test is not intended for column classification as good or bad; however, columns that exhibit certain properties may be more suitable for a given application than others. Test Conditions: The influence of chromatographic conditions on test results was examined for several different parameters. Relative changes in retention have been evaluated in reference 4 for ph, temperature, buffer concentration, and mobile phase composition. Because retention, efficiency, and peak shape are influenced by testing conditions, column evaluation should be carried out under standardized conditions to facilitate column comparisons. The largest changes in retention behavior occur with changes in the mobile phase composition. As specified in the Instructions for Handling, Storage, and Use section of this certificate, the recommended composition of the mobile phase is 80 % methanol and 20 % buffer (volume fractions), where the buffer composition is 20 mmol/l potassium phosphate adjusted to ph 7.0 ± 0.1. The retention of and is strongly dependent on the ph of the potassium phosphate buffer solution (see Figure 4). The retention of is reduced at high ph, whereas the retention of is reduced at low ph. At ph 7.0, both solutes exhibit significant retention. The ionic strength of the buffer is less significant. Only slight changes in retention, efficiency, and peak asymmetry are SRM 870 Page 6 of 9

measurable with changes on the phosphate buffer concentration at ph 7.0. The presence of the buffer is essential, however. At levels below 1 mmol/l (buffer concentration before dilution with methanol), As and k increase dramatically for. The absolute retention of the polar and nonpolar components increase with the percentage of buffer in the mobile phase (at ph 7.0 and constant ionic strength in the mixed solution). A composition of 80 % methanol and 20 % buffer was selected to provide appropriate retention for a broad range of column types. 6 5 retention time 4 3 2 1 2 3 4 5 6 7 8 9 10 ph Figure 4. Plot of Retention vs. ph for Amitriptyline and Quinizarin Injection volume can also significantly influence test results (see Figure 5). Separation efficiency typically decreases with increased injection volume. Injection overload results in degraded peak shape and, in some instances, reduced retention. An injection volume of 1 µl to 2 µl is recommended for 4.6 mm i.d. columns. Proportionately smaller injection volumes may be required for smaller i.d. columns. Changes in column temperature influence the absolute retention of the components in SRM 870; however, relatively small effects are observed in the peak shape of or. It is recommended that column temperature be controlled to 23 C ± 1 C. Column Comparisons: Forty-one commercial C18 columns were utilized in the development of SRM 870. Columns were selected to represent a broad sampling of chromatographic retention properties, and included alkyl phases prepared with embedded polar functional groups. No two columns exhibit identical retention behavior; however, similarities do exist among several columns. Among columns utilized, values of k for ranged from 0.2 to 2.8. In contrast, only slight differences were observed for methylene selectivity (αe/t; range, 1.26 to 1.45). The retention of ranged from k = 1 to k = 23.6. In two instances, no elution of this compound was detected. Peak asymmetry values ranged from As = 1.1 to As = 5.7 (peaks were not defined well enough in two instances to permit determination of As). Finally, the retention of ranged from k = 1.4 to k = 72.9 (As = 1.0 to As = 11). Figure 2 illustrates typical elution patterns for SRM 870. Five of the columns utilized are known to contain embedded polar functional groups within the stationary phase to improve chromatographic performance toward bases. The separation of SRM 870 was similar for these columns. In each case, eluted last, and both and exhibited symmetrical peak shape (e.g., Figure 2A). Peak asymmetry data for and are plotted in Figure 6. The scatter in the data indicates independence of the two terms. Thus, it is possible for a column to exhibit high activity toward chelating agents and low activity toward bases, or other combinations (e.g., Figures 2C through 2F). SRM 870 Page 7 of 9

2.5 µl 10 µl relative response 20 µl 50 µl 100 µl 0 2 4 6 8 10 12 14 retention time (minutes) Figure 5. Separations of SRM 870 for Different Injection Volumes Peak Asymmetry (Amitriptyline) 10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 6 Peak Asymmetry (Quinizarin) Figure 6. Plot of Peak Asymmetry for Amitriptyline vs. Peak Asymmetry for Quinizarin for Various C18 Columns SRM 870 Page 8 of 9

REFERENCES [1] May, W.; Parris, R.; Beck, C.; Fassett, J.; Greenberg, R.; Guenther, F.; Kramer, G.; Wise, S.; Gills, T.; Colbert, J.; Gettings, R.; MacDonald, B.; Definitions of Terms and Modes Used at NIST for Value-Assignment of Reference Materials for Chemical Measurements; NIST Special Publication 260-136; U.S. Government Printing Office: Washington, DC (2000); available at http://www.nist.gov/srm/publications.cfm (accessed July 2016). [2] JCGM 100:2008; Evaluation of Measurement Data Guide to the Expression of Uncertainty in Measurement (GUM 1995 with Minor Corrections); Joint Committee for Guides in Metrology (JCGM) (2008); available at http://www.bipm.org/utils/common/documents/jcgm/jcgm_100_2008_e.pdf (accessed July 2016); see also Taylor, B.N.; Kuyatt, C.E.; Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results; NIST Technical Note 1297, U.S. Government Printing Office: Washington, DC (1994); available at http://www.nist.gov/pml/pubs/index.cfm (accessed July 2016). [3] JCGM 101:2008; Evaluation of Measurement Data Supplement 1 to the Guide to Expression of Uncertainty in Measurement Propagation of Distributions Using a Monte Carlo Method; JCGM (2008); available at http://www.bipm.org/utils/common/documents/jcgm/jcgm_101_2008_e.pdf (accessed July 2016). [4] Efron, B.; Tibshirani, R.J.; An Introduction to the Bootstrap; Chapman & Hall: London, UK (1993) [5] Snyder, L.R.; Kirkland, J.J.; Introduction to Modern Liquid Chromatography; 2nd edition; Wiley-Interscience: New York (1979). [6] Neue, U.D.; Serowik, E.; Iraneta, P.; Alden, B.A.; Walter, T.H.; Universal Procedure for the Assessment of the Reproducibility and the Classification of Silica-Based Reversed-Phase Packings I. Assessment of the Reproducibility of Reversed-Phase Packings; J. Chromatogr. A, Vol. 849, pp. 7 100 (2000). [7] Engelhardt, H.; Arangio, M.; Lobert, T.; A Chromatographic Test Procedure for Reversed-Phase HPLC Column Evaluation; LC GC, Vol. 15, pp. 856 866 (1997). [8] Nacalai Tesque, Inc.; Product Catalog; Kyoto, Japan (1998). Certificate Revision History: 07 July 2016 (Change of expiration date; editorial changes); 11 August 2011 (Addition of certified values for mass fractions of solution constituents; editorial changes; extension of certification period); 19 December 2002 (Updated specifications in the Chromatographic Conditions section to expand the utility of the test and removed data collected under previous test conditions); 30 October 2000 (Original certificate date). Users of this SRM should ensure that the Certificate of Analysis in their possession is current. This can be accomplished by contacting the SRM Program: telephone (301) 975-2200; fax (301) 948-3730, email srminfo@nist.gov; or via the Internet at http://www.nist.gov/srm. SRM 870 Page 9 of 9