Ion Mobility Mass Spectrometry of Complex Carbohydrates Collision Cross Sections of Sodiated N- linked Glycans. - Supporting Information -

Similar documents
Estimating Collision Cross Sections from Travelling Wave IM-MS Data: How it is done and what are the Problems?

- Supporting Information -

Estimating Collision Cross Sections of Negatively Charged N-Glycans using Traveling Wave Ion Mobility-Mass Spectrometry

Improved Ion Mobility Separation of Protein Conformations in the Gas Phase with SYNAPT G2 HDMS

Ion-mobility mass spectrometry of polyoxometalate Keplerate clusters and their supramolecular assemblies

APPLICATION SOLUTIONS FOR STRUCTURAL PROTEOMICS

Supporting Information

Fereshteh Zandkarimi, Samanthi Wickramasekara, Jeff Morre, Jan F. Stevens and Claudia S. Maier

INTRODUCTION OVERVIEW

David J. Harvey a, *, Ann P. Hunter a, Robert H. Bateman b, Jeff Brown b, Glen Critchley b

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

Effective temperature of ions in traveling wave ion mobility spectrometry

Numerous studies (for example [1 30]) on the

[ instrument specifications ]

Multi-stage Mass Spectrometry up to MS 4 on a QTof System

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

SUPPLEMENTARY INFORMATION

Mass Spectrometry Reveals the Direct Action of a Chemical Chaperone

The precursor (TBA) 3 [H 3 V 10 O 28 ] was synthesised according to the literature procedure. 1 (TBA = n tetrabutylammonium).

Mass Spectrometry. What is Mass Spectrometry?

Analysis of Multiply Charged Poly(ethylene oxide-co-propylene oxide) Using Electrospray Ionization Ion Mobility Spectrometry Mass Spectrometry

TANDEM MASS SPECTROSCOPY

Triwave. More Complete Characterization of Mixtures and Molecules

Incorporation of post-ionization, gas-phase separations

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

Hemoglobin (Hb) exists in the blood cells of

Lecture 8: Mass Spectrometry

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Electron Transfer Dissociation of N-linked Glycopeptides from a Recombinant mab Using SYNAPT G2-S HDMS

1. The range of frequencies that a measurement is sensitive to is called the frequency

MALDI-HDMS E : A Novel Data Independent Acquisition Method for the Enhanced Analysis of 2D-Gel Tryptic Peptide Digests

Electrospray ionization (ESI) has enabled the study

Lecture 8: Mass Spectrometry

Tendenze nell innovazione della strumentazione in spettrometria di massa:

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Ion mobility spectrometry (IM) has become an

SU photoresist and SU-8 Developer (1-methoxy-2-propanol acetate) were

Very recently Roussis and Proulx clearly demonstrated

Simple Setup for Gas-Phase H/D Exchange Mass Spectrometry Coupled to Electron

Gridless Overtone Mobility Spectrometry

Ion mobility mass spectrometry of two tetrameric membrane protein complexes reveals compact structures and differences in stability and packing

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

CEE 772 Lecture #27 12/10/2014. CEE 772: Instrumental Methods in Environmental Analysis

Zwitterionic i-motif structures are preserved in DNA negatively charged ions. produced by electrospray mass spectrometry

CEE 772: Instrumental Methods in Environmental Analysis

UPLC Intact MASS Analysis Application Kit

CONTRIBUTION OF ION MOBILITY FOR STRUCTURAL ANALYSIS AND ANALYTICAL CHEMISTRY: THE USE OF PROBE LIGANDS AND SELECTIVE IMS SHIFT REAGENTS

Supporting Information

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Factors Affecting Mass Measurement Accuracy in a TOF Mass Spectrometer. Curtis D. Cleven, James Little, Eastman Chemical Company, Kingsport, TN

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

Introduction to the Q Trap LC/MS/MS System

FOCUS: 31 st ASILOMAR CONFERENCE, NATIVE MS-BASED STRUCTURAL BIOLOGY: RESEARCH ARTICLE

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

Supplementary information

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Mass Spectrometry in MCAL

Supplementary information

Ion mobility spectrometry (IMS) [1] is a gas-phase

Electron capture dissociation of extremely supercharged protein. ions formed by electrospray ionisation

Chemistry Instrumental Analysis Lecture 35. Chem 4631

How Hot are Your Ions in TWAVE Ion Mobility Spectrometry?

«M. Warner: What does your work enable researchers to do they weren't able to do before?

Technical Note. Introduction

Mass spectrometry (MS) has the ability to provide both

Chapter 1. Introduction

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

Harris: Quantitative Chemical Analysis, Eight Edition

Combined utilization of ion mobility and ultra-highresolution mass spectrometry to identify multiply charged constituents in natural organic matter

Miniaturized Ultra High Field Asymmetric Waveform Ion Mobility Spectrometry Combined with Mass Spectrometry for Peptide Analysis

IDENTIFICATION OF ORGANOMETALLIC COMPOUNDS USING FIELD DESORPTION IONIZATION ON THE GCT

Figure S1. Interaction of PcTS with αsyn. (a) 1 H- 15 N HSQC NMR spectra of 100 µm αsyn in the absence (0:1, black) and increasing equivalent

Accurate Mass Analysis of Hydraulic Fracturing Waters

FUTURE CONFIRMATORY CRITERIA

Ion trap. 3D Quadrupole Trap. -Mass spectrometer -Ion trap (Quadrupol Ion Storage, Quistor) 18. April

Detection of surfactants-metal ion complexes by electrospray mass spectrometry

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Supporting information Gas-phase conformations of capistruin comparison of lasso, branched-cyclic and linear topologies

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Mass Selective Ejection by Axial Resonant Excitation from a Linear Ion Trap

Applications of ion mobility mass spectrometry for high throughput, high resolution glycan analysis

Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC)

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

Determination of viral protein assembly and function by mass spectrometry - Dr. Alison E. Ashcroft, University of Leeds, UK

Supporting Information for the paper: Structure-Reactivity Correlations in Metal Atom Substitutions of Monolayer- Protected Noble Metal Alloy Clusters

Optimization of the sample preparation and extraction methodology

pmod An Advanced Protein Deconvolution Algorithm with Automated Peak Modeling for Charge Deconvolution of Mass Spectrometry Data

Chirality and Packing in Small Proline Clusters

GRADUATE COURSE IN MASS SPECTROMETRY: LECTURE 2

Instrumentation development for coupling ion/ion reactions and ion mobility in biological mass spectrometry

International Journal of Mass Spectrometry

MasSPIKE (Mass SPectrum Interpretation and Kernel Extraction) for Biological Samples p.1

LC-MS Based Metabolomics

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Native mass spectrometry (native MS) is a method to

Reliable Tracking In-solution Protein Unfolding via Ultrafast Thermal Unfolding/Ion Mobility-Mass Spectrometry

Transcription:

Ion Mobility Mass Spectrometry of Complex Carbohydrates Collision Cross Sections of Sodiated N- linked Glycans Kevin Pagel, 1 *, David J. Harvey 2, 3 - Supporting Information - 1 Fritz Haber Institute of the Max Planck Society, Department of Molecular Physics, Faradayweg 4-6, 14195 Berlin, Germany, 2 Department of Biological Sciences, University of Warwick, Coventry, CV4 7AL, UK, 3 University of Oxford, Department of Biochemistry, South Parks Road, Oxford OX1 3QU UK S1

Experimental Details Glycan Release N-linked glycans were released with hydrazine 1,2 from the well-characterized glycoproteins ribonuclease B 3, porcine thyroglobulin, 4,5 chicken ovalbumin, 6,7 and bovine fetuin 8 obtained from Sigma Chemical Co. Ltd. (Poole, Dorset, UK) and re-acetylated. Alternatively to hydrazinolysis, which produces relatively large amounts of sample, glycans can also be released on a smaller scale with the enzyme protein N-glycosidase F (PNGase F) using well-established methods. 9,10 After cleavage, the samples were stored at -20 C until required. Sialic acids were removed from the thyroglobulin and fetuin samples by heating with 1% acetic acid for 1 hour at 70 C. For electrospray analysis, samples were dissolved in water:methanol (1:1, v:v) at about 1 mg/ml. CCS Measurements Measurement of absolute collision cross sections (CCS) were performed on a modified Synapt HDMS 11 (Waters, Manchester, UK) quadrupole-im-ms instrument with a linear (not travelling wave) drift tube which was described in detail previously. 12,13 Briefly, in this instrument, glycan ions and their fragments are generated in a nano electrospray (nano-esi) ion source using capillaries prepared in-house using an established protocol. 14 In order to ensure sufficient fragmentation, ions where subjected to in-source collisions using high cone and skimmer voltages. Subsequently, the ion beam was focussed via a stacked-ring ion guide and transferred into a quadrupole region where ions with m/z below 32,000 could be pre-selected. Afterwards, the ions enter an array of three stacked-ring assemblies of which the second one was modified to serve as linear, RF-confined drift tube with a length of 18cm. IMS separation was followed by mass analysis using an orthogonal ToF mass analyzer. Typical settings for the analyzed glycans were: capillary voltage, 1.0-1.5 kv; sample cone 150 V, extractor cone 10 V; cone gas, 40 L/h; trap collision voltage, 10 V; trap DC bias, 25 V; IMS drift voltage, 50-150 V; ion transfer stage pressure, 2-5 mbar; trap pressure, 8.5 10-2 mbar (He), 4.5 10-2 mbar (N 2 ); ion mobility gas, He / N 2 ; ion mobility cell pressure, 3.2 mbar (He), 1.7 mbar (N 2 ); time-of-flight analyzer pressure, 2-3 10-6 mbar. All mass spectra were calibrated externally using an aqueous solution of caesium iodide (100 mg/ml) and were processed with the MassLynx software (Version 4.1, Waters, Manchester, UK). Spectra are shown with minimal S2

smoothing and without background subtraction. CCS values were determined from the slopes of drift time versus reciprocal drift voltage plots as described previously. 12,15 CCSs were calculated as reported previously. At constant temperature and pressure, the velocity of the ions in the IMS cell (v) is directly proportional to their mobility (K) and the applied electric field (E) (see eq. 1). v = KE (1) The drift time t D that is needed to traverse a cell of length L is proportional to the inverse mobility (1/K) as well as the inverse field (1/E) (see eq. 2). Consequently, the mobility of a given ion is typically determined by plotting the drift time t D vs. the inverse drift voltage and subsequent linear regression. The intercept of the fit t 0 corresponds to the time required to transport the ions from the end of the drift region into the mass analyzer. t D = L KE + t 0 (2) In practice, each sample was measured at eight different drift voltages ranging from 50 to 150 V. Drift times where extracted from the raw data by fitting a Gaussian distribution to the ATD of a given ion. A representative plot of the reciprocal drift voltages versus the centroid drift time in helium is shown for the singly sodiated ribonuclease B carbohydrates in Figure S1. The correlation coefficients of the fit were typically above 0,9996. From the obtained mobilities, absolute CCSs where calculated using the Mason-Schamp equation: 16 CCS = 3e 16N 2π µk B T 1 K (3) where N is the drift gas number density, µ the reduced mass of the ion and drift gas, k B the Bolzmann constant and T the temperature. The reported CCSs represent averages of three (He) or two (N 2 ) replicates acquired in independent measurements. S3

TW IMS Measurements and CCS Estimation High-resolution TW IMS measurements were performed on an unmodified Synapt HDMS G2 S 8 kda quadrupole-im-ms instrument (Waters, Manchester, UK). Typically 5 µl of sample was electrosprayed from platinum-palladium-coated borosilicate capillaries prepared inhouse. 17 Typical instrument settings were: capillary voltage, 1.0-1.5 kv; sample cone 150 V; extractor cone 150 V; cone gas, 60 L/h; trap and transfer collision voltage, 2-5 V; wave velocity, 550, 600, 650, 700 and 750 m/s; wave height, 40 V; ion transfer stage pressure (stepwave), 8 mbar; trap pressure, 4.5 10-2 mbar; ion mobility gas, N 2 ; ion mobility cell pressure, 3 mbar; time-of-flight analyzer pressure, 1.2 10-6 mbar. All spectra were calibrated externally using a solution of caesium iodide (100 mg/ml) and were processed with MassLynx 4.1 software (Waters, Manchester, UK). CCS estimation was carried out as reported previously. 12,18 Briefly, the measured drift times were corrected for m/z dependent delay time in the instrument with c being an empirically determined constant (c = 0.001 x EDC delay coefficient). t ' D = t D c m / z (4) Absolute glycan CCSs (CCS DT ) were corrected for charge and reduced mass. DT CCS CCS'= z 1 + 1 (5) m Ion m Gas The slope of the plot of ln(t D ) versus ln(ccs ) yields an exponential factor A which is used to calculate final corrected drift times (t D ). Finally, estimated CCSs (CCS TW ) are determined by plotting absolute CCS (CCS DT ) as a function of t D. t D ''=(t D ') A z 1 m Ion + 1 m Gas (6) Absolute CCSs determined in He (CCS DT He ) served as calibrants to estimate He TW IMS CCSs (CCS* TW He ) from TW IMS measurements in N 2. The CCSs estimated from the calibration were surprisingly insensitive to the applied wave velocity (550, 600, 650, 700 and 750 m/s) and where, therefore, averaged. S4

Data Analysis During the measurements, ion mobility as well as mass spectrometric information is acquired simultaneously. The raw data containing drift time t D and m/z information were analyzed using an in-house developed Python code and an extraction tool provided by Waters. Briefly, the software extracts arrival time distributions (ATDs) for a given mass window. Often the obtained ATDs contained more than one, but well separated features, which is predominantly caused by overlapping clusters with identical m/z but different charge state. In these cases, the two most intense peaks where fitted by Gaussian distributions and the extracted drift times where used to calculate/estimate the corresponding CCSs. Figure S1. Reciprocal drift voltage versus drift time t D plots of singly sodiated ribonuclease B glycans and their CID fragments. Drift times where extracted from raw data by fitting a single Gaussian to the arrival time distribution of the particular ion. The slope of the linear fit is directly proportional to the reciprocal mobility K. Correlation coefficients where typically higher than 0.9996. S5

Figure S2. ATDs of A) Man 6 GlcNAc 2 measured on the G1 instrument and B) Man 6 GlcNAc 2 measured on a G2S instrument as native glycan (bottom), fragment of Man 7 GlcNAc 2 (middle), and fragment of Man 9 GlcNAc 2 (top). The broad and not fully resolved peak in B indicates that at least two structurally different fragments with m/z 1419.5 are formed via CID of larger highmannose glycans. S6

REFERENCES (1) Patel, T.; Bruce, J.; Merry, A.; Bigge, C.; Wormald, M.; Parekh, R.; Jaques, A. Biochemistry 1993, 32, 679. (2) Wing, D. R.; Rademacher, T. W.; Field, M. C.; Dwek, R. A.; Schmitz, B.; Thor, G.; Schachner, M. Glycoconj. J. 1992, 9, 293. (3) Fu, D.; Chen, L.; O'Neill, R. A. Carbohydr. Res. 1994, 261, 173. (4) de Waard, P.; Koorevaar, A.; Kamerling, J. P.; Vliegenthart, J. F. J. Biol. Chem. 1991, 266, 4237. (5) Kamerling, J. P.; Rijkse, I.; Maas, A. A. M.; van Kuik, J. A.; Vliegenthart, J. F. G. FEBS Lett. 1988, 241, 246. (6) Da Silva, M. L. C.; Stubbs, H. J.; Tamura, T.; Rice, K. G. Arch. Biochem. Biophys. 1995, 318, 465. (7) Harvey, D. J.; Wing, D. R.; Küster, B.; Wilson, I. B. H. J. Am. Soc. Mass Spectrom. 2000, 11, 564. (8) Green, E. D.; Adelt, G.; Baenziger, J. U.; Wilson, S.; Van Halbeek, H. J. Biol. Chem. 1988, 263, 18253. (9) Morelle, W.; Faid, V.; Chirat, F.; Michalski, J.-C. In Glycomics; Packer, N., Karlsson, N., Eds.; Humana Press: 2009; Vol. 534, p 3. (10) Morelle, W.; Michalski, J.-C. Nat. Protocols 2007, 2, 1585. (11) Pringle, S. D.; Giles, K.; Wildgoose, J. L.; Williams, J. P.; Slade, S. E.; Thalassinos, K.; Bateman, R. H.; Bowers, M. T.; Scrivens, J. H. Int. J. Mass Spectrom. 2007, 261, 1. (12) Bush, M. F.; Hall, Z.; Giles, K.; Hoyes, J.; Robinson, C. V.; Ruotolo, B. T. Anal. Chem. 2010, 82, 9557. (13) Pagel, K.; Natan, E.; Hall, Z.; Fersht, A. R.; Robinson, C. V. Angew. Chem. Int. Ed. 2013, 52, 361. (14) Hernandez, H.; Robinson, C. V. Nat. Protocols 2007, 2, 715. (15) Kemper, P. R.; Dupuis, N. F.; Bowers, M. T. Int. J. Mass Spectrom. 2009, 287, 46. (16) Revercomb, H. E.; Mason, E. A. Anal. Chem. 1975, 47, 970. (17) Hernández, H.; Robinson, C. V. Nat. Protocols 2007, 2, 715. (18) Ruotolo, B. T.; Benesch, J. L. P.; Sandercock, A. M.; Hyung, S.-J.; Robinson, C. V. Nat. Protocols 2008, 3, 1139. S7

S8