Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Similar documents
Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Selection of a Capillary GC Column

Secrets of GC Column Dimensions

Column Dimensions. GC Columns and Consumables. Mark Sinnott Application Engineer. March 12, 2010

Introduction to Capillary GC

Selection of a Capillary

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

Rapid Analysis of Food and Fragrances Using High-Efficiency Capillary GC Columns. Application. Authors. Abstract. Introduction

Introduction to Capillary GC

Practical Fast Gas Chromatography for Contract Laboratory Program Pesticide Analyses *

Understanding the Capillary GC Column: How to Choose the Correct Type and Dimension

GC Resolution Do You See What I See?

Choosing the Correct GC Column Dimensions and Stationary Phase

Understanding Gas Chromatography

How To Select the Correct GC Column. Simon Jones Application Engineer

Author. Abstract. Introduction

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

A New Web-Based Application for Modeling Gas Chromatographic Separations

Introduction to Gas Chromatography

Introduction and Principles of Gas Chromatography

Hydrogen as a Carrier Gas in the Analysis of Polar/Non-Polar Compounds Using the Polyarc System. Application Note. Author. Introduction.

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Speakers. Moderator. John V Hinshaw GC Dept. Dean CHROMacademy. Tony Taylor Technical Director CHROMacademy. Dave Walsh Editor In Chief LCGC Magazine

Water Injections in GC - Does Water Cause Bleed?

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Theory and Instrumentation of GC. Chromatographic Parameters

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Study of Residual Solvents in Various Matrices by Static Headspace

Supelco Ionic Liquid GC Columns Introduction to the Technology

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Get Selective. By Jaap de Zeeuw

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Trajan SGE GC Columns

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

GAS CHROMATOGRAPHY (GC)

CHEM340 Tutorial 4: Chromatography

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

Activity in the FID Detection Port: A Big Problem if Underestimated

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

GC Analysis of Polybrominated Flame Retardants Application

ANNE JUREK. Abstract: soils and are found. in can also with GC/MS. poster. in series. option for. There are problems. analytes. in methanol.

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Volatile organic compounds (VOCs):

Chromatography. Gas Chromatography

The Focus Robotic Sample Processor as a Tool for the Multiple Analysis of Samples using Complementary Techniques

STANDARD OPERATING PROCEDURES

Accurate Analysis of Fuel Ethers and Oxygenates in a Single Injection without Calibration Standards using GC- Polyarc/FID. Application Note.

Chapter 31 Gas Chromatography. Carrier Gas System

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Analysis of BTEX in Natural Water with SPME

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

The Effects of Carrier Gas Viscosity and Diffusion on Column Efficiency in Capillary Gas Chromatography

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

USEPA Methods 8270 and 8260 on a Single GCMS Without Changing Columns

Headspace Technology for GC and GC/MS: Features, benefits & applications

CHAPTER 6 GAS CHROMATOGRAPHY

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Analysis of Geosmin and 2-Methylisoborneol Utilizing the Stratum PTC and Aquatek 70

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

GC-CI-MS analysis of TMS derivatives

Determination of Volatile Substances Proof of Food Adulteration

U.S. EPA Method 8270 for multicomponent analyte determination

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Highly Sensitive and Rugged GC/MS/MS Tool

TOTALLY INNOVATIVE MULTIMODE AUTOSAMPLER NEW KONIK ROBOKROM Laboratory Gas Generators An Overview +8 OPERATIONAL MODES MAIN FEATURES

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Exercise in gas chromatography

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Ultra-Inert chemistry for Trace Level Analysis

Evaluation of Capillary Columns for General Performance Parameters

Solid Phase Micro Extraction of Flavor Compounds in Beer

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

CHEM 429 / 529 Chemical Separation Techniques

Gas chromatography. Advantages of GC. Disadvantages of GC

The Suite for Environmental GC Analysis

Continuous Improvement in Petroleum/Petrochemical Analysis HP s Family of Innovative PLOT Columns

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

2] The plate height in chromatography is best described as 2

Application. Gas Chromatography February Introduction

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Transcription:

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software GC Columns and Consumables Mark Sinnott Application Engineer January 8 th, 2008 Page 1

Questions to Ask What information do you need from your analysis? Do you have more baseline than you need between your peaks? Do you need to resolve all of the components? Page 2

Variables for Shortening Run Times Stationary Phase Temperature Programming Carrier Gas: type and linear velocity Shorten Column Length Decrease Film Thickness Decrease Internal Diameter Page 3

Resolution N k α 1 R = s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 4

Resolution N k α 1 R = s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 5

Stationary Phase - Common Types Siloxane polymers Poly(ethylene) glycols Porous polymers Page 6

Selectivity Relative spacing of the chromatographic peaks The result of all non-polar, polarizable and polar interactions that cause a stationary phase to be more or less retentive to one analyte than another Page 7

Optimizing Selectivity Match analyte polarity to stationary phase polarity - like dissolves like(oil and water don t mix) Take advantage of unique interactions between analyte and stationary phase functional groups Page 8

Start with the Right Phase DB-1 15m x 0.32mm, 0.25µm Oven: 40 C for 2 min 40-120 C at 5 C/min 0 2 4 6 8 10 12 14 Time (min.) DB-Wax 15m, 0.32mm, 0.25µm Oven: 80-190 C at 20 C/min 0 1 2 3 4 5 Time (min.) Page 9

Resolution N k α 1 R = s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f,r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 10

Column Length and Efficiency (Theoretical Plates) Length (m) n 15 69,450 30 138,900 60 277,800 0.25 mm ID n/m = 4630 (for k = 5) Page 11

Column Length and Resolution R α n α L Length X 4 = Resolution X 2 t α L Page 12

Column Length VS Resolution and Retention: Isothermal R=0.84 2.29 min R=1.16 4.82 min R=1.68 8.73 min 15 m 30 m 60 m Double the plates, double the time but not double the the resolution Page 13

DECREASE THE LENGTH DB-5 30 m 0.53 mm I.D., 0.5 µm 1 2 3 4 5.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 DB-5 15 m 0.53 mm I.D., 0.5 µm 1. Benzene 2. Toluene 3. Ethylbenzene 4. m,p-xylene 5. o-xylene 1 2 3 4 5 1.0 2.0 3.0 4.0 5.0 6.0 BTEX Carrier: Helium, 36 cm/sec at 40 c Oven : 40 C for 3 min, 5 /min to 100 C Page 14

Column Length and Cost 15m 30m 60m $ $ $ $ $ $ $ Page 15

Length Summary If you Decrease Length: Efficiency Resolution Analysis Time Pressure Cost Decrease Decrease Decrease Decrease Decrease Page 16

Resolution N k α 1 R = s 4 k + 1 α Efficiency Retention Selectivity N = ƒ (gas, L, r c ) k = ƒ (T, d f, r c ) α = ƒ (T, phase) L = Length r c = column radius d f = film thickness T = temperature Page 17

Column Diameter - Theoretical Efficiency Total Plates I.D. (mm) n/m 5 m N ~ 112,000 0.05 23,160 10 m N ~ 112,000 0.10 11,580 0.18 6,660 20 m N ~ 112,000 0.20 5830 0.25 4630 30 m N ~ 112,000 0.32 3660 0.45 2840 k = 5 0.53 2060 Page 18

Different Column I. D. Equal Phase Ratios Column: DB-624 30 m, 0.53 mm, 3 m Carrier: Oven: Helium, 40(cm/sec) 65 C Injection: Split Detector: FID Column: DB-624 30 m, 0.32 mm, 1.8 m 0 5 10 15 20 Time (min) Page 19

PHASE RATIO (β) Film Thickness Column Dimensions Phase Ratio β 30 m x.53 mm x 3.0 μm 44 30 m x.32 mm x 1.8 μm 44 K C = k β β = r 2d f Page 20

Column Diameter and Capacity I.D. (mm) Capacity (ng) 0.05 1-2 0.10 6-13 0.18 25-55 Like Polarity Phase/Solute 0.25 µm film thickness 0.20 35-70 0.25 80-160 0.32 110-220 0.45 600-800 0.53 1000-2000 Page 21

Column Diameter - Inlet Head Pressures (Helium) I.D (mm) Pressure (psig) 0.05 275-400 0.10 90-130 0.18 30-45 0.20 25-40 0.25 15-25 30 meters Hydrogen pressures x 1/2 0.32 10-20 0.45 3-7 0.53 2-4 Page 22

Column Diameter and Carrier Gas Flow Lower flow rates: Smaller diameter columns Higher flow rates: Larger diameter columns Low flow rates : GC/MS High flow rates: Headspace, purge & trap Page 23

Diameter Summary If you decrease the inside diameter: Efficiency Resolution Pressure Capacity Flow rate Increase Increase Increase Decrease Decrease Page 24

Combining a Change in Length With a Change in Diameter Decrease Length Decrease Diameter Efficiency Analysis Time Page 25

Carrier Gas Considerations Best velocity? Optimal range of velocities Too low or high results in loss of resolution Balance resolution and analysis time BUT... there is no LAW against going FASTER Page 26

Carrier Gas Considerations Van Deemter Curve 1.00 Excessive Diffusion h 0.75 0.50 He Poor Mass Transfer 0.25 ū opt H 2 OPGV 10 20 30 40 50 60 u (cm/sec) Page 27

Carrier Gas Considerations Utilizing Computer Controlled Flow Ramping (EPC) Lonely Late Eluters? = P Decrease retention and overall run time by increasing pressure (speed up the gas!) Page 28

Easy Options with Method Translation Software Different Column Dimensions Switch He to H 2 Carrier Gas and Try Faster Velocities Same Column & Gas Type but Faster Velocities Combination of all of the above Page 29

CLP-Pesticides - Original Improved Method 0.32mm I.D., Helium Carrier Gas 1 2 3 4 5,6 7 8 10 9 11 12 13 14 Column: DB-XLB 30m x 0.32mm i.d., 0.25µm Carrier: He, constant flow, 38 cm/s at 120 C Injector: Pulsed Splittless, 220 C Pulse pressure & time: 35psi for 1.15min Oven: 15 16 17 18 2µL, 50ppb 120 C for 1.17min 120 C to 160 C at 25 /min 160 C to 260 C at 10 /min 260 C to 300 C (4min) at 15 /min Detector: µ-ecd, 320 C Ar/CH4 (P5) makeup gas at 60mL/min 21 19 <16 minutes 22 20 6.00 8.00 10.00 12.00 14.00 16.00 Page 30

Input Original Method Parameters Page 31

Same Column and Gas Type Fast Analysis (OPGV) Transfer same dimensions New Velocity New Temp. Program Page 32

Same Column and Gas Type Fast Analysis (OPGV) Before No Real Changes in Resolution! 6.00 8.00 10.00 12.00 14.00 16.00 Only Time! <14 minutes Page 33

Same Column and Gas type None mode, Try higher velocities New calculated temp. program Page 34

Same Column and Gas type None mode, Higher velocities Before Co-elution (poorer) 6.00 8.00 10.00 12.00 14.00 16.00 80 cm/sec Co-elution (poorer) <8 minutes 65 cm/sec <10 minutes Close elution (similar) 50 cm/sec Page 35

Same Column, Hydrogen Carrier Gas Translate Only Page 36

Same Column, H 2 Carrier Gas Translate Only Before No Real Changes in Resolution 6.00 8.00 10.00 12.00 14.00 16.00 33% faster! 11 minutes Page 37

Same Column, H2 Carrier Gas, Higher Velocities Page 38

Same Column, H2 Carrier Gas, Even Higher Velocities Co-elution Before 6.00 8.00 10.00 12.00 14.00 16.0 85 cm/sec Co-elution 7 minutes 80 cm/sec Co-elution <8 minutes 70 cm/sec Page 39

New Column Dimensions, H 2 Gas, Translate Only Input NEW dimensions Close enough (got lucky) New Velocity New Temp. Program Page 40

New Column Dimensions, H2 Gas, Translate Only Page 41

New Column Dimensions, H2 Gas, Translate Only 5 10 11 6 Page 42

New Column Dimensions, H2 Gas, Fast Analysis New Velocity New Temp. Program Page 43

New Column Dimensions, H2 Gas, Fast Analysis Better Resolution and Faster Analysis! 03.003.504.004.505.005.506.006.507.00 Page 44

New Column Dimensions, H2 Gas, Higher Velocities Page 45

New Column Dimensions, H2 Gas, Higher Velocities 105 cm/sec? 5.5 minutes! 95 cm/sec <6 minutes 85 cm/sec Page 46

Final Method Used at EPA 1 2 3 4 5 6 7 8 12 10 9 13 11 Column: DB-XLB 20m x 0.18mm i.d., 0.18µm Carrier: H2, constant flow, 77.3cm/s at 120 C Injector: Pulsed Splittless, 220 C Pulse pressure & time: 35psi for 0.5min Flow ramp at 6.25min of 99mL/min 2 to 3mL/min 2mm i.d. liner Oven: 14 15 16 17 0.5µL, 50ppb 120 C for 0.49min 120 C to 160 C at 59.4 /min 160 C to 260 C at 23.7 /min 260 C to 300 C (1.69min) at 35.6 /min Detector: µ-ecd, 320 C Ar/CH4 (P5) makeup gas at 60mL/min 21 18 19 20 22 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 Page 47

Final Method Used at EPA 2 5 3 7 12 10 1 8 9 13 11 6 14 4 DB-XLB 15 16 17 18 19 20 21 22 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 1 2 3 4 6 5 7 8 9 10 12 13 11 DB-17ms 14 16 15 1718 19 20 21 22 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 Page 48

Food/Fragrance Method translation Page 49

Food/Fragrance Method translation Page 50

Spearmint Oil 10.6 min Δ -16.8 min (0.18 mm, H 2 Carrier) 17.7 min Δ -9.7 min (0.18 mm, He Carrier) (0.25 mm, He Carrier) 27.4 min 3 8 13 18 23 28 Time (min) Page 51

Spearmint Oil Resolution Check Δ -16.8 min (0.18 mm, H 2 Carrier) 10.6 min Δ -9.7 min (0.18 mm, He carrier) 17.7 min (0.25 mm, He Carrier) 27.4 min Page 52

Resolution Maintained Compound s Compound Resolution 0.25 mm 0.18 mm 0.18 mm Helium Helium Hydrogen Sabinene 1.52 1.59 1.56 β-pinene α-terpinene 1.61 1.73 1.86 p-cymene Speed Gain N/A 35% 61% Page 53

CONCLUSIONS Stationary Phases Chosen for optimized selectivity Diameter Smaller allows shorter length but has less capacity Make Small Changes Again think capacity Carrier Gas Hydrogen, high velocity, but can still go fast with He Temperature Program Scale properly to preserve elution pattern Method Translation Software FREE, reliable Flow Ramp Increase at end of run for late eluters (if necessary) Page 54

Thank you! TECHNICAL SUPPORT Agilent 1-800-227-9770 #4, #1 E-mail: gc_column_support@agilent.com Page 55

Thank you for attending Agilent Technologies e-seminar today. For a full listing of our e-seminar offerings as well as our hands-on training classes, please go to our website at: www.agilent.com/chem/education Or register for Stay current with e-notes to receive regular updates Page 56 Slide 56

Upcoming e-seminars NEW! Carrier Gases in Capillary GC - Series 1 January 15, 2008-1:00 p.m. EST Introduction to Capillary GC - Series 2 February 20, 2008-1:00 p.m. EST Selection of a Capillary GC Column - Series 3 March 13, 2008-2:00 p.m. EST Page 57 Sli de

Looking for more information on Agilent s GC Systems and Software? Agilent offers a full range of GC training courses including hands-on courses with the latest 7890 GC equipment as well as 6890 and 5890 courses. Each course includes a course manual for future reference and a certificate of completion. All courses are taught by industry experts. Call 800 227 9770, Option 5 or visit www.agilent.com/chem/education to register today! Page 58

New On Demand Webinar: Utilizing Sub-Two Micron Particles to Optimize HPLC Methods A Four Part Workshop on Managing Chemistry and Pressure for Faster and More Efficient HPLC Separations www.separationsnow.com/agilentwebinar Be sure to register after today s s event. Our measure is your success. Page 59