VELOCITY MEASUREMENTS IN CAPILLARIES

Similar documents
BIOSPECKLE SIZE AND CONTRAST MEASUREMENT APPLICATION IN PARTICLE SIZING AND CONCENTRATION ASSESSMENT

LIQUID FILM THICKNESS OF OSCILLATING FLOW IN A MICRO TUBE

Miniature Illuminator for Laser Doppler Velocimeter Assembled on Micromachined Silicon optical bench.

HYDROBETA: A NEW INSTRUMENT FOR MEASURING IN-SITU PROFILES OF THE VOLUME SCATTERING FUNCTION FROM 10 TO 170 DEGREES

Manual Laser Doppler Anemometry Manual remote experiment Project e-xperimenteren+

Measurement of the laser cut front geometry

Velocity Measurement of Blood Flow in a Microtube Using Micro PIV System

PIV Measurements of the Influence of Seeding Particles Concentration on the Velocity of an EHD Flow

Jones Matrix Imaging for Transparent and Anisotropic Sample

Measurements of rotational transform due to noninductive toroidal current using motional Stark effect spectroscopy in the Large Helical Device

Lichtausbreitung in streuenden Medien: Prinzip und Anwendungsbeispiele

Low Coherence Vibration Insensitive Fizeau Interferometer

RESAGK, Christian 1 ; DIETHOLD, Christian 2 ; FRÖHLICH, WERNER, Michael 3 ;

Measurement of Electrostatic Charge and Aerodynamic Diameter of Sub-Micron Particles by the ESPART Analyzer

FLOW VISUALIZATION OF FERROMAGNETIC NANO- PARTICLES ON MICROCHANNEL FLOW USING DARK FIELD MICROSCOPY

Simultaneous Velocity and Concentration Measurements of a Turbulent Jet Mixing Flow

Laser and pinching discharge plasmas spectral characteristics in water window region

Gratings in Electrooptic Polymer Devices

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

APPLICATION OF SHADOW DOPPLER VELOCIMETRY TO ARBITRARY-SHAPED DROPLET MEASUREMENT IN WATER SPRAY

First observations of the second solar spectrum with spatial resolution at the Lunette Jean Rösch

Analysis of the signal fall-off in spectral domain optical coherence tomography systems

Flow measurement without phase information in optical coherence tomography images

Comparative Measurement in Speckle Interferometry using Fourier Transform

Determination of the composition of multicomponent droplets by rainbow refractometry

by applying two pairs of confocal cylindrical lenses

Robust and Miniaturized Interferometric Distance Sensor for In-Situ Turning Process Monitoring

A PIV Algorithm for Estimating Time-Averaged Velocity Fields

Digital Holographic Measurement of Nanometric Optical Excitation on Soft Matter by Optical Pressure and Photothermal Interactions

SIMULTANEOUS VELOCITY AND CONCENTRATION MEASUREMENTS OF A TURBULENT JET MIXING FLOW

Velocity and temperature measurements in a large-scale Rayleigh-Bénard experiment using LDA and micro thermistors

Density Field Measurement by Digital Laser Speckle Photography

홀로그램저장재료. National Creative Research Center for Active Plasmonics Applications Systems

Characterization of atomization processes in suspension/emulsion sprays. Walter Schäfer 1*, Cameron Tropea 2

Single Photon Generation & Application in Quantum Cryptography

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters

LIBSlab ANALYZERS ANALYZERS

Shadow Doppler velocimetry with double fiber-array sensors

Characterization of MEMS Devices

Dual-beam incoherent cross-correlation spectroscopy

Wavefront metrology and beam characterization in the EUV/soft X-ray spectral range

EUV Reflectivity measurements on Acktar Sample Magic Black

Efficient sorting of orbital angular momentum states of light

Visualization of Convective Structures by Methods of the Hilbert Optics and Phase-Shift Interferometry

Fish embryo multimodal imaging by laser Doppler digital holography

LASER BASED DIAGNOSTIC SYSTEM FOR SPRAY MEASUREMENTS

Fractional wavelet transform

Turbulence control in a mixing tank with PIV

Plasma Spectroscopy in ISTTOK

Experiment and Simulation Study on A New Structure of Full Optical Fiber Current Sensor

Laser Doppler Anemometry. Introduction to principles and applications

A dual scintillator - dual silicon photodiode detector module for intraoperative gamma\beta probe and portable anti-compton spectrometer

Signal to Noise Comparison of IS-Instruments Ltd High Throughput OEM Spectrometer and a Czerny Turner Instrument. July 2013

6. Laser Doppler Anemometry. Introduction to principles and applications

Development of Target Injection and Tracking for IFE in Japan

Ms. Monika Srivastava Doctoral Scholar, AMR Group of Dr. Anurag Srivastava ABV-IIITM, Gwalior

Measurement of novel micro bulk defects in semiconductive materials based on Mie scatter

For more information, please contact

Mat. Res. Soc. Symp. Proc. 406, (1996).

Experimental study of CO 2 releases from a saturated liquid reservoir

SEMATECH 157nm Technical Review

Simulation study of the sensing field in electromagnetic tomography for two-phase flow measurement

Temperature ( o C)

Multimodal optical spectrometers for remote chemical detection.

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

Thermal Imaging at Multiple Time Instants for Study of Self-Heating and ESD Phenomena

FSA TM Multi-bit Digital Processors

10. OPTICAL COHERENCE TOMOGRAPHY

Improved diode laser spectrometer for ortho/para ratio measurements in water vapor

Time-resolved pump-probe system based on a nonlinear imaging technique with phase object

Low Temperature Physics Measurement Systems

Experimental Optics. Optical Tweezers. Contact: Dr. Robert Kammel, Last edition: Dr. Robert Kammel, February 2016

Resonantly Pumped Er:YAG and Er:YAP Lasers

Experimental and numerical investigation on particle-induced liquid metal flow using Lorentz force velocimetry

Optical diagnostic techniques for spray systems

SUPPLEMENTARY INFORMATION

Analytical Investigation of Fuel Cells by Using In-situ and Ex-situ Diagnostic Methods

LUMiSizer. Dispersion Analyser. The All-in-One. Dispersion Analyser. Stability Demixing Consolidation Particle Sizing

Final exam questions ED

iprom Optical Interferometry Prof. Dr. -Ing. Rainer Tutsch Institut für Produktionsmesstechnik IPROM Technische Universität Braunschweig

stabilized 10-fs lasers and their application to laser-based electron acceleration

Measurement of the velocities of dielectric particles in ER fluids with laser speckle

Dynamic Complex Wavefront Modulation with an Analogue Spatial Light Modulator

Electrically Induced Instabilities of Liquid Metal Free Surfaces

Introduction to laser-based combustion diagnostics

Birefringence dispersion in a quartz crystal retrieved from a channelled spectrum resolved by a fibre-optic spectrometer

Research of a novel fiber Bragg grating underwater acoustic sensor

Development of measurement technique to evaluate thermal conductivity of thermoelectric Bi 2 Te 3 submicron thin films by photothermal radiometry

Quantum Ghost Imaging by Measuring Reflected Photons

Qualitative Analysis of Human Semen Using Microwaves

Advanced techniques Local probes, SNOM

A Brief Introduction to Medical Imaging. Outline

Advanced Optical Coherence Tomography techniques: novel and fast imaging tools for non-destructive testing

CHARACTERISTIC DISTRIBUTION OF SUBMICRON AND NANO-PARTICLES LADEN FLOW AROUND CIRCULAR CYLINDER

LASER TRAPPING MICRO-PROBE FOR NANO-CMM

Chapter 10: Wave Properties of Particles

A Fabry-Perot Interferometer System for high-speed velocity measurement. Lun K. Cheng, A.J.A. Bruinsma, W.C. Prinse* and C.

Transient Electro-Optic Properties of Liquid Crystal Gels

Effect of Liquid Viscosity on Sloshing in A Rectangular Tank

5. 3P PIV Measurements

Transcription:

VELOCITY MEASUREMENTS IN CAPILLARIES S. Bergeler 1, I. Menn, K. Michel 1 1 Institut für Allgemeine Elektrotechnik, University of Rostock, D-18051 Rostock, Germany Klinik und Poliklinik für Innere Medizin, Abt. für Klinische Pathophysiologie, Faculty of Medicine, University of Rostock, D-18057 Rostock, Germany Abstract: A new velocimeter for measurements in microscopic regions is presented. A common charge coupled device (CCD) has been used as spatial filter for one-component velocity measurements. The characteristics of this sensor are investigated and first application results presented. Keywords: Charge coupled devices, optical velocity measurements, blood cell velocity 1 INTRODUCTION Spatial filtering velocimetry (SFV) is a well-known optical technique for determining the velocity of moving objects based on the scattering of light on optical inhomogeneities [1, ]. The most developed technology for SFV is based on the usage of a number of photodetectors. Schulz and Fiedler suggested to replace the separate receivers by a charge coupled device (CCD) [3]. Velocity sensors based on these solid-state imagers have been used for measurements on a variety of surfaces and inside a a circulating fluidized bed [4]. Several authors verified the usefulness of complicated spatial filtering systems based on transmission gratings or fiber arrays for the measurement of flow in glas tubes, capillaries and small vessels [5, 6]. In this paper the application range of CCD-sensors will also be extended to measurements in these microscopic applications. A new generation of highly miniaturized spatial filtering velocimeters particularly suited for the requirements in these applications will be presented. Furthermore, a novel CMOS sensor has been applied for measurements. focusing lens s(t) object lens detector y x transmission grating y 0 v x0 moving objects x 0 z 0 Figure 1. Principle of spatial filtering velocimetry FUNDAMENTALS The basic principle is shown in Figure 1. A photodetector observes moving objects throught a number of parallel slits. The output signal of the detector s(t) contains a frequency, which is proportional to the velocity of both particles or surfaces. f g v = β (1)

where β denotes the optical magnification (image scale) and g the interval of grating lines. Instead of transmission gratings or optical fiber arrays in our approach photodetector arrays (such as CCD lines) are acting both as detectors and as the spatial filter. These sensors ensure the required high precision of the grating, and misalignment problems are drastically reduced. Detailed investigations of all sensor design aspects have been carried out in order to ensure optimal filtering characteristics of the sensor []. The sensor employs a differential grating arrangement in order to remove the dc component in the output signal without additional filtering. A realization of a differential grating is shown schematically in Fig.. Furthermore, depending on the pattern size of the measuring object different weighting functions can be realized by using different clocking regimes. This flexibility has significant practical advantages. By arranging the detector readout in a way that two phase orthogonal gratings are formed, even the advantageous quadrature signal processing technique may be used for velocity estimation [7, 8]. 1 3 4... N-1 N s(t) Figure. Schematic of a differential grating spatial filter using a line sensor 3 SIGNAL PROCESSING Several signal processing techniques can be used in order to determine the central frequency of the spatial filter output signal. Commonly used are the fast Fourier transform [6], the counter principle [] and the quadrature demodulation technique [5]. A typical output signal recorded at a velocity of about 11,4 mm s -1 is shown in Fig. 3(a). The output signal has been processed in a PC using a LabView based software. The frequency f related to the velocity of the particles in the liquid is estimated using a fast Fourier transform algorithm. Fig. 3(b) shows the spectrum of the output signal. 4 EXPERIMENTAL RESULTS The new sensor already proved to be useful for measurements of the flow velocity in small cylindrical glas tubes. The flow velocity distribution in such a tube (80 µm diameter) has been measured in order to investigate the spatial and temporal resolution of the sensor. Fig. 4 shows the experimental setup. A beam splitter is included in order to observe the image while the object velocity is being measured. Both a CCD line sensor and a CMOS-Camera (51 x 51) with direct pixel access hve been used for the actual measurement. In the letter case however, in practice only a line of 56 pixels corresponding to 8 grating periods has been used. u power density 0.005 0.01 0.015 0.0 0.05 t [s] 500 1000 1500 000 500 f [Hz]

Figure 3. Output signal (a) and its power density spectrum (b) Many lenses can be adapted for online microscopy, for instance microscope objectives, enlarger lenses, camera lenses or custom lenses. Finally, a Tevidon 1,4/5 camera lens which works backward has been chosen. This inexpensive solution provides a total magnification in this optical path of about 1,8x, a working distance of 17 mm and a depth of field of 5 µm. The experiment was performed using a liquid with the optical properties of human blood (particle sizes of 5...10µm correspond to the size of the red blood cells. However, this liquid did not match the non-newtonian behaviour of human blood. With a viscosity of 697 mpa/s and a resulting Reynolds number of approximately 0,01 the flow is laminar. Therefore, the theoretical velocity profile could be calculated using r v(r) = vmax 1 () R with v max being determined from the flow rate known from the pump. Fig. 5 shows the velocity distributions and their standard deviations compared with the theoretical values. Currently, the sensor is used in order to perform in vivo measurements of the blood cell velocity in capillaries at the human nailfold. The fingernailfold is extensively used for analysing morphological changes of skin capillaries in different systemic diseases [9]. The sensor represents a cost-effective alternative to transmission gratings, frame-to-frame analysis and laser Doppler velocimeters [9] currently used for the investigation of human microcirculation. In this application the observation camera, a standard CCD-Matrix-Camera (768 x 576 pixels), is used in order to get an overview of all the nailfold capillaries at a total magnification of 5x (Fig. 6). In these capillaries velocities from almost zero up to only mm/s can be expected. In order to avoid the problems usually associated with velocity components near or equal to zero carrier modulation techniques may be used in order tor ealize a frequency shift of the output signal. The illumination is a crucial parameter in this application. This measuring system uses a ring illumination with green LED s in order to achieve a high contrast between the red blood cells and the surrounding tissue. Another problem is the detection of particular capillaries. The use of two cameras enables the selection of a particular capillary for the measurement. measuring camera observatio n camera

Figure 4. Experimental setup 0 v in mm/s 3.5 v in mm/s 15 10 5 1.5 1 0.5 50 100 150 00 50 300 s in µm 50 100 150 00 50 300 s in µm Figure 5. Velocity profile and theoretical values (thick lines) for a liquid with the optical properties of human blood, recorded with a CCD line sensor (left) and a CMOS camera (right) Figure 6. Typical image of normal fingernail-fold capillaries

5 CONCLUSIONS A novel velocimeter for measurements in microscopic applications incorporating either a CCD line or a CMOS sensor has been presented. The design of the instrument and first experiences have been discussed. The new sensor appears to be a valuable and cost-effective tool for the investigation of microcirculation. ACKNOWLEDGMENT This work was partially funded by the Bundesland Mecklenburg-Vorpommern. REFERENCES [1] Y. Aizu and T. Asakura, Principles and development of spatial filtering velocimetry, Appl. Phys. B 43(4) (1987) p. 09-4. [] K. Christofori and K. Michel, Velocimetry with spatial filters based on sensor arrays, Flow Meas. Instrum. 7 (1996), Nr. 3/4, p. 65-7. [3] O. Fiedler and K.-P. Schulz, Geschwindigkeitsmessung mit CCD-Zeilenkamera nach dem Ortsfilterprinzip, Proc. 1. Int. Fachtagung Automatische Bildverarbeitung (CAIP), Berlin, 1985. [4] J. Kumpart, K. Michel, O. Fiedler, K. Christofori, Usage of the spatial filtering method for applications in multiphase flows. Proc. Second Int. Symp. on Measuring Techniques for Multiphase Flows (Beijing, China), 1998, p. 83-88. [5] Y. Aizu, T. Ushizaka, T. Asakura, Measurements of flow velocity in a microscopic region using a transmission grating: a differential type, Appl. Opt. 4 (1985), Nr. 5, p. 67-635. [6] E. Okada, H. Ehara, C. Oshio, E. Sekizuka, H. Minamitani, A microscopic spatial filtering velocimeter for measurements of lymph flow in microcirculation. Proc. IECON 91, Vol. 3, 1991, p. 375-378 [7] K. Michel, O. Fiedler, A. Richter, K. Christofori and S. Bergeler, A novel spatial filtering velocimeter based on a photodetector array, IEEE Trans. on Instrumentation and Measurement. 47 (1998), Nr. 1, p. 99-303. [8] K. Michel, K. Christofori, S. Bergeler, A. Richter, J. Kumpart, H. Krambeer and O. Fiedler, Miniaturized spatial filtering velocimeter for industrial applications, Proc. IEEE Instrumentation and Measurement Technology Conf. (St. Paul/Minnesota), Vol., 1998, p. 893-897. [9] A. Bollinger, B. Fagrell, Clinical Capillaroscopy, Toronto, Lewiston, Bern, Göttingen, Stuttgart, Hogrefe & Huber Publishers, 1990, 166 p. [10] M. Stücker, V. Baier, T. Reuther, K. Hoffmann, K. Kellam, P. Altmayer, Capillary blood cell velocity in human skin capillaries located perpendicularly to the skin surface: measured by a new laser Doppler anemometer, Microvascular Res. 5 (1996), p. 188-19. AUTHORS: Dipl.-Ing. Swen Bergeler, Dipl.-Ing. Klaus Michel, University of Rostock, Institut für Allgemeine Elektrotechnik, A.-Einstein-Str., D-18051 Rostock, Germany, Phone Int. ++49 381 498 3474, Fax ++49-381 498 3480, E-mail: michel@warnow.e-technik1.uni-rostock.de Dipl.-Ing. Ingolf Menn, Klinik und Poliklinik für Innere Medizin, Abt. für Klinische Pathophysiologie, Faculty of Medicine, University of Rostock, D-18057 Rostock, Germany